首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
The complete pharmacokinetic disposition of the chiral flavonoid (±) pinostrobin remains unknown without the development of an analytical method of detection and quantitation of its individual enantiomers. Resolution of the enantiomers of pinostrobin was achieved using as simple high‐performance liquid chromatographic method. A Chiralpak® AD‐RH column was employed to perform baseline separation with UV detection at 287 nm. The standard curves were linear ranging from 0.5 to 100 µg/mL for each enantiomer. The limit of quantification was 0.5 µg/mL. Precision and accuracy of the assay was < 15% (RSD) and was with a bias <15% for all points on the calibration curve. The assay was applied successfully to stereoselective serum disposition of pinostrobin enantiomers in rats. Both enantiomers had a serum half‐life of ~7 h. They also shared similar values of volume of distribution (Vd S‐pinostrobin, 8.2 L/kg; Vd R‐pinostrobin, 8.9 L/kg), total clearance (S‐pinostrobin CLtotal, 0.959 L//h/kg; R‐pinostrobin CLtotal, 1.055 L//h/kg), and area under the curve (S‐pinostrobin AUCinf, 23.16 µg h/mL; R‐pinostrobin AUCinf, 21.296 µg h/mL). The large volume of distribution suggests extensive distribution of pinostrobin into tissues. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
An analytical method enabling the detection and quantification of the individual enantiomers of racemic (±) pinocembrin is required to fully characterize its pharmacokinetic disposition. Direct resolution of the enantiomers of pinocembrin was achieved using a novel and simple reversed‐phase high‐performance liquid chromatography method with electrospray ionization and detection by mass spectrometry in rat serum. A Chiralcel® AD‐RH column was employed to perform baseline separation with electrospray positive‐mode ionization with selected ion monitoring detection. The standard curves were linear from 0.5 to 100 µg/mL for each enantiomer. The limit of quantification was 0.5 µg/mL. The assay was applied successfully to stereoselective serum disposition of pinocembrin enantiomers in rats. Pinocembrin enantiomers were detected in serum. Both enantiomers had a serum half‐life of ~15 min in rats. Similar values of volume of distribution between the enantiomers were also observed: 1.76 L/kg for S‐pinocembrin and 1.79 L/kg for R‐pinocembrin. Total clearance was 5.527 L//h/kg for S‐pinocembrin and 5.535 L/h/kg for R‐pinocembrin, and the area under the curve was 1.821 µg h/mL for S‐pinocembrin and 1.876 µg h/mL for R‐pinocembrin. The large volume of distribution coupled with the short serum half‐life suggests extensive distribution of pinocembrin into the tissues. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
A high‐performance liquid chromatographic method was developed for the analysis of 3'‐hydroxypterostilbene. This method involves the use of a Luna® C18 column with ultraviolet detection at 325 nm. The mobile phase consisted of acetonitrile, water and formic acid (50:50:0.01, v/v/v) with a flow rate of 0.8 mL/min. The calibration curves were linear over the range 0.5–100.0 µg/mL. The mean extraction efficiency was between 97.40 and 111.16%. The precision of the assay was 0.196–14.39% (RSD%), and within 15% at the limit of quantitation (0.5 µg/mL). The bias of the assay was <16% and within 15% at the limit of quantitation. This assay was successfully applied to pre‐clinical pharmacokinetic samples from rat urine and serum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Pharmacometric characterization studies of liquiritigenin have historically overlooked its chiral nature. To achieve complete characterization, an analytical method enabling the detection and quantification of the individual enantiomers of racemic (±) liquiritigenin is necessary. Resolution of the enantiomers of liquiritigenin was achieved using a simple high‐performance liquid chromatographic method. A Chiralpak® ADRH column was employed to perform baseline separation with UV detection at 210 nm.The standard curves were linear ranging from 0.5 to 100 µg/mL for each enantiomer. Limit of quantification was 0.5 µg/mL. The assay was applied successfully to stereoselective serum disposition of liquiritigenin enantiomers in rats. Liquiritigenin enantiomers were detected in serum as both aglycones and glucuronidated conjugates. Both unconjugated enantiomers had a serum half‐life of ~15 min in rats. The volume of distribution (Vd) for S‐ and R‐liquiritigenin was 1.49 and 2.21 L/kg, respectively. Total clearance (Cltotal) was 5.12 L/h/kg for S‐liquiritigenin and 4.79 L/h/kg for R‐liquiritigenin, and area under the curve (AUC0‐inf) was 3.95 µg h/mL for S‐liquiritigenin and 4.23 µg h/mL for R‐liquiritigenin. The large volume of distribution coupled with the short serum half‐life suggests extensive distribution of liquiritigenin into tissues. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
A method for analysis of lacosamide [(R)‐2‐acetamido‐N‐benzyl‐3‐methoxypropionamide] is needed for both human and veterinary pharmacokinetic investigations. While lacosamide is currently used to manage partial‐onset seizures in humans suffering from epilepsy, it is also presently being investigated for use in the treatment of canine epilepsy in veterinary medicine. Currently, no dosing regimen for the drug exists in dogs. A novel and simple high‐performance liquid chromatography method was developed for determination of lacosamide in dog serum. Serum proteins (0.1 mL) were precipitated with ?20.0°C acetonitrile after addition of the internal standard, daidzein. Separation was achieved with a Phenomenex® Luna® C18 (2) (5 µm, 250 × 4.60 mm) column with ultraviolet detection at 210 nm. The calibration curves were linear ranging from 0.5 to 25 µg/mL. Precision of the assay was <13% (RSD) and was within 12% for all points in the calibration curve. The limit of quantitation for this method was 0.5 µg/mL. The assay was applied successfully to a pre‐clinical study of lacosamide pharmacokinetics in dogs. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
A simple chiral high‐performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for measuring Cloquintocet‐mexyl (ClM) enantiomers and clodinafop‐propargyl (CP) using cellulose tris‐(3,5‐dimethylphenylcarbamate) (CDMPC) as chiral stationary phase (CSP). The effects of mobile phase composition and column temperature on the ClM enantiomer separation were investigated. Good separation was achieved by using a mixture of n‐hexane and n‐propanol as mobile phase. Based on the chiral HPLC method, enantioselective quantitative determination analysis methods for this herbicide combined with CP in diluted plasma were developed and validated. The assay method was linear over a range of concentrations (0.5–100 µg/mL) in diluted plasma and the mean recovery was greater than 80% for both enantiomers and CP. The limits of quantification and detection for both ClM enantiomers and CP were 0.5 and 0.2 µg/mL, respectively. Intra‐ and interday relative standard deviations did not exceed 10% for three tested concentrations. The result suggested that the degradation of ClM enantiomers was stereoselective in rabbit plasma, and both rac‐ClM and CP degraded quickly in plasma, showing that the main existing forms with biological effect in animals are their metabolites. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
A high‐performance liquid chromatography (HPLC) method for assay of d ‐Lys6–GnRH contained in a microemulsion‐type formulation is described. The peptide is extracted from the microemulsion matrix and quantified using a two‐step gradient method. Separation from microemulsion compounds and potential peptide oxidation products was achieved on a Jupiter C18 column at 40°C, using a gradient of 10–35% CH3CN for peptide elution. The correlation of peak intensity measured at 220 nm and peptide concentration was linear over the range 2.5–60 µg/mL with a correlation coefficient of 0.9997 and a y‐intercept not significantly different from zero (p > 0.05). Intraday and interday variability of the assay was less than 5% for multiple injections of samples containing 7.5, 30 and 60 µg/mL. The lower limit of quantitation was calculated to be 0.38 µg/mL, and the lower limit of detection was 0.13 µg/mL. The assay was applied to samples that were stressed under physiological conditions (37°C, pH 7.4) over 4 days. Three degradation peaks were well resolved from the parent peptide, demonstrating the selectivity of the assay. Off‐line MALDI TOF mass spectrometry was applied to identify these degradation species as oxidation products of the peptide. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
An effective, accurate and reliable HPLC with UV detection method was developed and validated for quantitation of six components: baicalin, berberine hydrochloride, quercetin, kaempferol, isorhamnetin and baicalein in intestinal perfusate using rotundin as an internal standard. The chromatographic separation was performed on a Welchrom‐C18 column (250 × 4.6 mm i.d. with 5.0 µm particle size) with a mobile phase consisting of acetonitrile, water, phosphoric acid and triethylamine (30:70:0.2:0.1,v/v) at a flow rate of 1.0 mL/min and a UV detection at 270 nm. The method had a chromatographic run time of 30 min and excellent linear behavior over the investigated concentration ranges observed with the values of r higher than 0.99 for all the analytes. The lower limit of quantification of the analytical method was 0.09 µg/mL for berberine hydrochloride, quercetin, kaempferol and baicalein and 0.18 µg/mL for baicalin and isorhamnetin. The intra‐ and inter‐day precisions measured at three concentration levels were all less than 10% for all analytes. The bias ranged from ?6.91 to 4.33%. The validated method has been successfully applied to investigate the rat intestine absorption profiles of baicalin, berberine hydrochloride, quercetin, kaempferol, isorhamnetin and baicalein. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
An efficient, simple, validated, analytical and semi‐preparative HPLC method has been developed for direct enantioresolution of (RS)‐Ketorolac (Ket) using monochloro‐methylated derivatives of cellulose and amylose, i.e. cellulose (tris‐3‐chloro‐4‐methylphenylcarbamate) and amylose (tris‐5‐chloro‐2‐methylphenylcarbamate) as chiral stationary phases (CSPs) with photo diode array detection at 320 nm. Enantioresolution was carried out in samples of human plasma spiked with (RS)‐Ket under normal and reversed‐phase elution modes with suitable mobile phase compositions. The effect of nature of alcohols (MeOH, EtOH, PrOH and n‐BuOH) and other solvents (MeCN and MeOH) as organic modifiers in the mobile phase was investigated on the separation performance of two CSPs in terms of retention and separation of enantiomers. The best resolution was observed on cellulose‐based CSP using EtOH, while using 2‐PrOH (15%) and amylose‐based CSP obtained the highest retention. Under reversed‐phase elution mode the best enantioseparation was observed using 30% MeCN with ammonium formate buffer. The elution order of enantiomers was ascertained by determining specific rotations. The limit of detection and quantitation values were 5 and 15.5 ng/mL for each enantiomer of (RS)‐Ket, respectively. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
A new pre‐column derivative high‐performance liquid chromatography (HPLC) method for determination of d ‐glucose with 3‐O‐methyl‐d ‐glucose (3‐OMG) as the internal standard was developed and validated in order to study the gluconeogenesis in HepG2 cells. Samples were derivatized with 1‐phenyl‐3‐methy‐5‐pyrazolone at 70°C for 50 min. Glucose and 3‐OMG were extracted by liquid–liquid extraction and separated on a YMC‐Triart C18 column, with a gradient mobile phase composed of acetonitrile and 20 mm ammonium acetate solution containing 0.09% tri‐ethylamine at a flow rate of 1.0 mL/min. The eluate were detected using a UV detector at 250 nm. The assay was linear over the range 0.39–25 μm (R2 = 0.9997, n = 5) and the lower limit of quantitation was 0.39 μm (0.070 mg/mL). Intra‐ and inter‐day precision and accuracy were <15% and within ±3%, respectively. After validation, the HPLC method was applied to investigate the gluconeogenesis in Dulbecco's modified Eagle medium (DMEM) cultured HepG2 cells. Glucose concentration was determined to be about 1–2.5 μm in this gluconeogenesis assay. In conclusion, this method has been shown to determine small amounts of glucose in DMEM successfully, with lower limit of quantitation and better sensitivity when compared with common commercial glucose assay kits. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
We developed and validated a simple, sensitive, selective and reliable LC–ESI‐MS/MS method for direct quantitation of dropropizine enantiomers namely levodropropizine (LDP) and dextrodropropizine (DDP) in rat plasma without the need for derivatization as per regulatory guidelines. Dropropizine enantiomers and carbamazepine (internal standard) were extracted from 50 μL rat plasma using ethyl acetate. LDP and DDP resolved with good baseline separation (Rs = 4.45) on a Chiralpak IG‐3 column. The mobile phase consisted of methanol with 0.05% diethylamine pumped at a flow rate of 0.5 mL/min. Detection and quantitation were done in multiple reaction monitoring mode following the transitions m/z 237 → 160 and 237 → 194 for dropropizine enantiomers and the internal standard, respectively, in the positive ionization mode. The proposed method provided accurate and reproducible results over the linearity range of 3.23–2022 ng/mL for each enantiomer. The intra‐ and inter‐day precisions were in the ranges of 3.38–13.6 and 5.11–13.8 for LDP and 4.19–11.8 and 8.89–10.1 for DDP. Both LDP and DDP were found to be stable under different stability conditions. The method was successfully used in a stereoselective pharmacokinetic study of dropropizine enantiomers in rats following oral administration of racemate dropropizine at 100 mg/kg. The pharmacokinetic results indicate that the disposition of dropropizine enantiomers is not stereoselective and chiral inversion does not occur in rats.  相似文献   

12.
Selenomethionine (SeMet) is a widely used nutritional supplement that has potential benefit for people living in selenium‐deficient areas. Previous research has shown that selenium administered as SeMet undergoes significant enterohepatic recycling which may involve the gut microflora. In order to investigate this we have developed a simple method for the quantitation of l ‐SeMet in rat gut content suspensions prepared from jejunum, ileum, caecum and colon. After incubation of l ‐SeMet with gut content suspensions, samples were deproteinized with sulfosalicylic acid and derivatized with o‐phthaldialdehyde (OPA) and N‐acetyl‐l ‐cysteine (NAC). Mass spectrometry confirmed the formation of a 1:1:1 derivative of l ‐SeMet with OPA and NAC. Samples were analysed by reversed‐phase high‐performance liquid chromatography with fluorescence detection. The assay was linear in the concentration range 0.5–100 µg/mL (r2 = 0.9992) with a limit of detection of 0.025 µg/mL (signal‐to‐noise ratio of 5). Intra‐day and inter‐day accuracies were 91.1–92.8 and 91.7–95.5%, respectively with corresponding precisions as relative standard deviation of <5%. Incubation of l ‐SeMet with gut content suspensions from different parts of the rat intestine showed that l ‐SeMet metabolism occurs mainly in the caecum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, sensitive and stability‐indicating high‐performance liquid chromatographic (HPLC) assay method was developed and validated for a bioactive peptide, lysine–proline–valine (KPV) in aqueous solutions and skin homogenates. Chromatographic separation was achieved on a reversed phase Phenomenex C18 column (4.6 × 250 mm, packed with 5 µm silica particles) with a gradient mobile phase consisting of 0.1% trifluoroacetic acid (TFA) in water (A) and 0.1% TFA in acetonitrile (B). The proposed HPLC method was validated with respect to accuracy, precision, linearity, repeatability, limit of detection (LOD) and limit of quantitation (LOQ). The calibration curve was linear with a correlation coefficient (r) of 0.9999. Relative standard deviation values of accuracy and precision experiments were <2. The LOD and LOQ of KPV were 0.01 and 0.25 µg/mL, respectively. Under stress conditions (acid, alkali and hydrogen peroxide) KPV yielded lys–pro–diketopiperazine as major degradation product, which was identified by flow injection MS analysis. The developed HPLC method was found to be efficient in separating the active peptide from its degradation products generated under various stress conditions. Also, the validated method was able to separate KPV from other peaks arising from endogenous components of the skin homogenate. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
A method of analysis for 3‐methoxypterostilbene [trans‐3,3′5‐trimethoxy‐4′hydroxystilbene] in biological fluids is necessary to study pharmacokinetics. A novel and simple high‐performance liquid chromatographic method was developed for the determination of 3‐methoxypterostilbene in rat serum and urine. The internal standard, pinosylvin, was added to 0.1 mL serum or urine (serum proteins were precipitated with cold acetonitrile at ?20°C). Separation was achieved with a Phenomenex® C18 (2) (5 µm, 250 × 4.60 mm) column with ultraviolet detection at 327 nm. The calibration curves in both matrices were linear ranging from 0.05 to 100 µg/mL, and the mean extraction efficiency was >99%. Precision of the assay for both matrices was <12% (RSD) and was within 13% for all points on the calibration curve. The limit of quantification for this method was 0.05 µg/mL. The assay was successfully applied to a preliminary study of 3‐methoxypterostilbene pharmacokinetics in a rat. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
A highly sensitive, rapid assay method has been developed and validated for the estimation of S‐citalopram (S‐CPM) in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of S‐CPM and phenacetin (internal standard, IS) from rat plasma with t‐butyl methyl ether. Chromatographic separation was operated with 0.2% formic acid:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a Symmetry Shield RP18 column with a total run time of 3.0 min. The MS/MS ion transitions monitored were 325.26 → 109.10 for S‐CPM and 180.10 → 110.10 for IS. Method validation and pre‐clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.5 ng/mL and the linearity was observed from 0.5 to 5000 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.14–5.56 and 0.25–12.3%, respectively. This novel method has been applied to a pharmacokinetic study and to estimate brain‐to‐plasma ratio of S‐CPM in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
Three methods were developed and validated for determination of nemonoxacin in human feces and its major metabolite, nemonoxacin acyl‐β‐ d ‐glucuronide, in human urine and feces. Nemonoxacin was extracted by liquid–liquid extraction in feces homogenate samples and nemonoxacin acyl‐β‐ d ‐glucuronide by a solid‐phase extraction procedure for pretreatment of both urine and feces homogenate sample. Separation was performed on a C18 reversed‐phase column under isocratic elution with the mobile phase consisting of acetonitrile and 0.1% formic acid. Both analytes were determined by liquid chromatography–tandem mass spectrometry with positive electrospray ionization in selected reaction monitoring mode and gatifloxacin as the internal standard. The lower limit of quantitation (LLOQ) of nemonoxacin in feces was 0.12 µg/g and the calibration curve was linear in the concentration range of 0.12–48.00 µg/g. The LLOQ of the metabolite was 0.0010 µg/mL and 0.03 µg/g in urine and feces matrices, while the linear range was 0.0010–0.2000 µg/mL and 0.03–3.00 µg/g, respectively. Validation included selectivity, accuracy, precision, linearity, recovery, matrix effect, carryover, dilution integrity and stability, indicating that the methods can quantify the corresponding analytes with excellent reliability. The validated methods were successfully applied to an absolute bioavailability clinical study of nemonoxacin malate capsule. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
A novel online column‐switching chiral high‐performance liquid chromatography method was developed and validated for the simultaneous determination of naftopidil (NAF) and its O‐desmethyl metabolites (DMN) enantiomers in rat feces. Direct and multiple injections of supernatant from rat feces homogenate were allowed through the column‐switching system. Analyte extraction was performed on the Capcell Pak mixed‐functional column by acetonitrile–phosphate buffer (pH 7.4; 10 mm ; 8:92, v/v) flowing at 1 mL/min. Separation of NAF and DMN enantiomers was achieved on the Chiralpak IA column by methanol–acetonitrile–acetate buffer (pH 5.3; 5 mm ; 45:33:22, v/v/v) flowing at 0.5 mL/min. The analytes were measured with a fluorescence detector at 290 nm (λex) and 340 nm (λem). The validated method showed a good linearity [22.5–15,000 ng/mL for (+)‐/(?)‐NAF; 35–25,000 ng/mL for (+)‐/(?)‐DMN] and the lowest limits of quantification for NAF and DMN enantiomers were 22.5 and 35 ng/mL, respectively. Both intra‐ and inter‐day variations were <10%. The assay was successfully applied to the fecal excretion of NAF and DMN enantiomers in rat after single oral administration of (±)‐NAF. Nonstereoselective excretion of (+)‐ and (?)‐NAF was found in feces, while stereoselective excretion of (+)‐ and (?)‐DMN was observed with higher excretion levels of (+)‐DMN, indicating that there may exist stereoselective metabolism for NAF enantiomers. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A simple, sensitive and specific high‐performance liquid chromatography mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of β‐hydroxy‐β‐methyl butyrate (HMB) in small volumes of rat plasma using warfarin as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. A simple liquid–liquid extraction process was used to extract HMB and IS from rat plasma. The total run time was 3 min and the elution of HMB and IS occurred at 1.48 and 1.75 min respectively; this was achieved with a mobile phase consisting of 0.1% formic acid in a water–acetonitrile mixture (15:85, v/v) at a flow rate of 1.0 mL/min on a Agilent Eclipse XDB C8 (150 × 4.6, 5 µm) column. The developed method was validated in rat plasma with a lower limit of quantitation of 30.0 ng/mL for HMB. A linear response function was established for the range of concentrations 30–4600 ng/mL (r > 0.998) for HMB. The intra‐ and inter‐day precision values for HMB were acceptable as per Food and Drug Administration guidelines. HMB was stable in the battery of stability studies, viz. bench‐top, autosampler freeze–thaw cycles and long‐term stability for 30 days in plasma. The developed assay method was applied to a bioavailability study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A simple and efficient liquid chromatography‐mass spectrometry (LC‐MS) method was developed and validated for simultaneous quantitation of catalpol and harpagide in normal and diabetic rat plasma. Protein precipitation extraction with acetonitrile was carried out using salidroside as the internal standard (IS). The LC separation was performed on an Elite C18 column (150 × 4.6 mm, 5 µm) with the mobile phase consisting of acetonitrile and water within a runtime of 12.0 min. The analytes were detected without endogenous interference in the selected ion monitoring mode with positive electrospray ionization. Calibration curves offered satisfactory linearity (r > 0.99) at linear range of 0.05–50.0 µg/mL for catalpol and 0.025–5.0 µg/mL for harpagide with the lower limits of quantitation of 0.05 and 0.025 µg/mL, respectively. Intra‐ and inter‐day precisions (RSD) were <9.4%, and accuracy (RE) was in the ?6.6 to 4.9% range. The extraction efficiencies of catalpol, harpagide and IS were all >76.5% and the matrix effects of the analytes ranged from 86.5 to 106.0%. The method was successfully applied to the pharmacokinetic study of catalpol and harpagide after oral administration of Zeng‐Ye‐Decoction to normal and diabetic rats, respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
A LC‐MS/MS method for the determination of a hydrophilic paclitaxel derivative 7‐xylosyl‐10‐deacetylpaclitaxel in rat plasma was developed to evaluate the pharmacokinetics of 7‐xylosyl‐10‐deacetylpaclitaxel in the rats. 7‐Xylosyl‐10‐deacetylpaclitaxel and docetaxel (IS for 7‐xylosyl‐10‐deacetylpaclitaxel) were extracted from rat plasma with acetic ether and analyzed on a Hypersil C18 column (4.6 × 150 mm i.d., particle size 5 µm) with the mobile phase of ACN/0.05% formic acid (50:50, v/v). The analytes were detected using an ESI MS/MS in the multiple reaction monitoring mode. The standard curves for 7‐xylosyl‐10‐deacetylpaclitaxel in plasma were linear (>0.999) over the concentration range of 2.0–1000 ng/mL with a weighting of 1/concentration2. The method showed a satisfactory sensitivity (2.0 ng/mL using 50 µL plasma), precision (CV ≤ 10.1%), accuracy (relative error ?12.4 to 12.0%), and selectivity. This method was successfully applied to the pharmacokinetic study of 7‐xylosyl‐10‐deacetylpaclitaxel in rat plasma after intravenous administration of 7‐xylosyl‐10‐deacetylpaclitaxel to female Wistar rats. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号