共查询到20条相似文献,搜索用时 4 毫秒
1.
《Journal of separation science》2018,41(15):3121-3128
Sarcosine is a potential prostate cancer marker. In this study, we developed a method of three‐phase solvent bar liquid‐phase microextraction combined with high‐performance liquid chromatography to determine sarcosine after derivatization with 4‐dimethylarminoazobenzene‐4‐sulfonyl chloride from human urine. The effects of different extraction conditions on extraction efficiency were investigated and optimized. Under optimum experimental conditions, a calibration graph exhibited linearity over the range of 0.05–25 μmol/L with a correlation coefficient (r2) of 0.9990. The enrichment factor was 168, and the detection limit was 0.02 μmol/L. The method was successfully used to analyze sarcosine in human urine and non‐invasive detection, and good spiked recoveries ranging from 90.5 to 93.6% were obtained. The proposed method exhibited high sensitivity, high enrichment factor, good precision, and a simple setup. It may contribute to the early accurate diagnosis and the progression monitoring of prostatic carcinoma. 相似文献
2.
Mass spectrometric characterisation of a condensation product between porphobilinogen and indolyl‐3‐acryloylglycine in urine of patients with acute intermittent porphyria 下载免费PDF全文
Josep Marcos Maria Ibañez Rosa Ventura Jordi Segura Jordi To‐Figueras Oscar J. Pozo 《Journal of mass spectrometry : JMS》2015,50(7):929-937
We document the presence of a previously unknown species in the urine of patients with acute intermittent porphyria (AIP). The compound was fully characterised by liquid chromatography tandem mass spectrometry. Interpretation of both full spectrum acquisition and product ion spectra acquired in positive and negative ionisation modes by quadrupole time of flight MS allowed for the identification of a condensation product arising from porphobilinogen (PBG, increased in the urine of AIP patients) and indolyl‐3‐acryloylglycine (IAG, derived from indolylacrylic acid and present in human urine). The structure was unequivocally confirmed through comparison between the selected reaction monitoring chromatograms obtained from the urinary species and the condensation product qualitatively synthesised in the laboratory. Owing to the large amounts of both PBG and IAG in urine of AIP patients, the possible ex vivo formation of PBG‐IAG in urine samples was evaluated. The product was spontaneously formed at room temperature, at 4 °C and even during storage at ?20 °C when spiking a control sample with PBG. A positive correlation was found between PBG and PBG‐IAG in samples collected from AIP patients. However, no correlation was found between PBG‐IAG and IAG. Purified PBG‐IAG did not form the characteristic chromogen after application of p‐dimethylaminobenzaldehyde in HCl, thus suggesting that the current techniques used to measure PBG in urine of AIP patients based on Ehlrich's reaction do not detect this newly characterised PBG‐IAG fraction. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
3.
《Journal of separation science》2017,40(21):4234-4245
An easy‐to‐handle magnetic dispersive solid‐phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe3O4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high‐performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid‐phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09–1.10 ng/mL. The proposed magnetic dispersive solid‐phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine. 相似文献
4.
《Journal of separation science》2017,40(10):2117-2122
A simple and reliable method was established for simultaneous determination of 4‐hydroxyphenyl acetic acid, 4‐hydroxyphenyl lactic acid, and 3,4‐hydroxyphenyl propionic acid in human urine by high‐performance liquid chromatography with fluorescence detection. Solid‐phase extraction was used to eliminate the interferences in urine. The separation of three analytes was achieved using a C18 column and a mobile phase formed by a 95:5 v/v mixture of 50 mmol/L ammonium acetate buffer at pH 6.8 that contained 5 mmol/L tetrabutyl ammonium bromide and acetonitrile. Under the optimized conditions, the detection limits of 4‐hydroxyphenyl acetic acid, 4‐hydroxyphenyl lactic acid, and 3,4‐hydroxyphenyl propionic acid were 4.8 × 10−3, 8.80 × 10−3, and 9.00 × 10−3 mg/L, respectively, and the recoveries were in the range of 85.0–120.0% with relative standard deviations of 1.5–3.1%. This method was used to analyze urine samples from breast cancer patients, healthy people and post‐surgery breast cancer patients. Significant differences in urinary levels of 4‐hydroxyphenyl acetic acid and 4‐hydroxyphenyl lactic acid could be found between the breast cancer patients group and other two groups. No effect of age and sex was observed on the urinary levels of 4‐hydroxyphenyl acetic acid and 4‐hydroxyphenyl lactic acid. This method might be helpful for cancer biomarkers discovery in urine. 相似文献
5.
Dongqin Tan Jing Jin Longxing Wang Xiaolin He Cuicui Guo Dhanjai Xianbo Lu Jiping Chen 《Journal of separation science》2019,42(5):991-998
Due to regulation of the use of bisphenol A, several analogs serving as bisphenol A replacements have drawn substantial attention for their adverse health effects. To investigate their occurrence in humans and identify possible pollution sources, it is necessary to develop a sensitive method for total bisphenols detection. Thus, a method based on enzymolysis and liquid‐liquid extraction followed by molecularly imprinted polymer solid‐phase extraction and pre‐column derivatization with high‐performance liquid chromatography and tandem mass spectrometry was proposed. The developed method exhibited superior selectivity and sensitivity. The matrix effect can be eliminated to a great extent. The method detection limits for eight bisphenols were 0.05~0.19 ng/mL. Satisfactory recoveries (71~119%) were obtained by spiking bovine serum at three levels (0.8, 8 and, 20 ng/mL). The method was successfully applied to determine total bisphenols in the serum samples of children. Bisphenol A, bisphenol F, bisphenol S, bisphenol B and bisphenol F were detected with concentrations from below the method detection limit to 1.65, 0.45, 0.79, 2.04 and 0.17 ng/mL, respectively. These results indicate that bisphenol A remains the major pollutant among the studied bisphenols in children, whereas threats from bisphenol A analogs should also be monitored. 相似文献
6.
建立了基于聚合物整体柱的固相萃取-高效液相色谱测定尿液中4种羟基多环芳烃(OH-PAHs)的分析方法。在注射器管中合成聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)整体柱(poly (BMA-co-EDMA)),并将其用于尿液中4种羟基多环芳烃的前处理,同时考察了上样浓度、淋洗液、洗脱液和洗脱体积对萃取效率的影响。结合高效液相色谱-荧光分析,4种羟基多环芳烃在各自的范围内线性关系良好(r≥0.9991);方法的检出限和定量限分别为0.06~0.09 ng/mL和0.20~0.30 ng/mL;日内(n=5)和日间(n=3)精密度分别为1.4%~5.3%和2.6%~7.3%。对焦炉工人尿液样品进行加标(3 ng/mL)回收试验,回收率为78.2%~117.0%。该固相萃取柱能够有效萃取和净化尿液中4种羟基多环芳烃,并且可以重复使用。该法简单、准确,可应用于尿液中羟基多环芳烃的分析。 相似文献
7.
Magnetic solid‐phase extraction for determination of sulpiride in human urine and blood using high‐performance liquid chromatography 下载免费PDF全文
A novel and efficient sample preconcentration technique based on the Fe3O4 magnetic nanoparticles (Fe3O4 MNPs) coated with silica (SiO2) has been developed for extraction and determination of sulpiride. The functionalized MNPs showed excellent dispersibility in aqueous solution and were applied to magnetic solid‐phase extraction of sulpiride from human urine and blood prior to high‐performance liquid chromatography analysis. The separation, preconcentration and desorption procedure was completed in 10 min. Optimal experimental conditions, including sample pH, the amount of the MNPs, eluent type and volume, and the ultrasonication time were studied and established. The method showed good linearity for the determination of sulpiride in the concentration range of 10–1000 ng/mL in urine and blood. The recovery of the method was in the range between 91.2 and 97.5%, and the limit of detection was 2 ng/mL for sulpiride in human blood and urine. The results indicated that the present procedure is a suitable pretreatment method for biological samples. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
8.
Jos Luís Dores‐Sousa Alejandro Fernndez‐Pumarega Jelle De Vos Michael Lmmerhofer Gert Desmet Sebastiaan Eeltink 《Journal of separation science》2019,42(2):522-533
The ability to control the external porosity and to tune the dimensions of the macropore size on multiple length scales provides the possibility of tailoring the monolithic support structure towards separation performance. This paper discusses the properties of conventional polymer–monolithic stationary phases and its limitations regarding the effects of morphology on kinetic performance. Furthermore, guidelines to improve the macropore structure are discussed. The optimal monolithic macropore structure is characterized by high external porosity (while maintaining ultra‐high‐pressure stability), high structure homogeneity, polymer globule clusters in the submicron range, and macropores with a diameter tuned toward speed (small diameter in the 100–500 nm range using short beds) or efficiency (larger macropores in the range of 500 nm–1 μm allowing the use of longer column formats). Finally, promising approaches to control the morphology are discussed. 相似文献
9.
Yibin Zheng Delei Cai Baifen Huang Jianlong Han Qing Chen Jingshun Zhang Jie Zhang Xiaofeng Wang Haitao Shen 《Journal of separation science》2019,42(3):760-768
We established a method for the separation and detection of nine hydroxylated polychlorinated biphenyls in whole blood and urine samples using ultra high performance liquid chromatography coupled with electrospray negative ionization tandem mass spectrometry. Clean‐up procedures involved a filtration step, and optimization involved a pretreatment step consisting of a simple liquid–liquid extraction using hydrated silica‐gel chromatography (5%). Nine hydroxylated polychlorinated biphenyls were separated on an ultra high performance liquid chromatography HSS T3 column using a gradient elution program of 2 mmol ammonium formate aqueous solution (A) and methanol (B). Recovery ranged from 84.0 to 105.4% for the nine different hydroxylated polychlorinated biphenyls in urine with three spiked levels of 0.1, 1, and 2 ng and from 73.5 to 98.6% for the blood with spiked levels of 0.2, 1, and 2 ng. The relative standard deviations were <8.7% (n = 6), and the limits of detection in urine and whole blood for the nine hydroxylated polychlorinated biphenyls were in the range of 1.5–4 and 20–100 pg/g, respectively. This analytical method may enable the simultaneous detection of various hydroxylated polychlorinated biphenyls from complex tissue matrices. 相似文献
10.
《Journal of separation science》2017,40(5):1024-1031
A novel periodic imidazolium‐bridged hybrid monolithic column was developed. With diene imidazolium ionic liquid 1‐allyl‐3‐vinylimidazolium bromide as both cross‐linker and organic functionalized reagent, a new periodic imidazolium‐bridged hybrid monolithic column was facilely prepared in capillary with homogeneously distributed cationic imidazolium by a one‐step free‐radical polymerization with polyhedral oligomeric silsesquioxane methacryl substituted. The successful preparation of the new column was verified by Fourier transform infrared spectroscopy, scanning electron microscopy, elemental analysis, and surface area analysis. Most interestingly, the bonded amount of 1‐allyl‐3‐vinylimidazolium bromide of the new column is three times higher than that of the conventional imidazolium‐embedded hybrid monolithic column and the specific surface area of the column reached 478 m2/g. The new column exhibited high stability, excellent separation efficiency, and enhanced separation selectivity. The column efficiency reached 151 000 plates/m for alkylbenzenes. Furthermore, the new column was successfully used for separation of highly polar nucleosides and nucleic acid bases with pure water as mobile phase and even bovine serum albumin tryptic digest. All these results demonstrate the periodic imidazolium‐bridged hybrid monolithic column is a good separation media and can be used for chromatographic separation of small molecules and complex biological samples with high efficiency. 相似文献
11.
Miroslav Jan
o David Sýkora Frantisek Svec Jean M. J. Frchet Johannes Schweer Reimer Holm 《Journal of polymer science. Part A, Polymer chemistry》2000,38(15):2767-2778
Rapid high‐performance liquid chromatography (HPLC) of polystyrenes, poly(methyl methacrylates), poly(vinyl acetates), and polybutadienes using a monolithic 50 × 4.6 mm i.d. poly(styrene‐co‐divinylbenzene) column have been carried out. The separation process involves precipitation of the macromolecules on the macroporous monolithic column followed by progressive elution utilizing a gradient of the mobile phase. Depending on the character of the separated polymer, solvent gradients were composed of a poor solvent such as water, methanol, or hexane and increasing amounts of a good solvent such as THF or dichloromethane. Monolithic columns are ideally suited for this technique because convection through the large pores of the monolith enhances the mass transport of large polymer molecules and accelerates the separation process. Separation conditions including the selection of a specific pair of solvent and precipitant, flow rate, and gradient steepness were optimized for the rapid HPLC separations of various polymers that differed broadly in their molecular weights. Excellent separations were obtained demonstrating that the precipitation‐redissolution technique is a suitable alternative to size‐exclusion chromatography (SEC). The molecular weight parameters calculated from the HPLC data match well those obtained by SEC. However, compared to SEC, the determination of molecular parameters using gradient elution could be achieved at comparable flow rates in a much shorter period of time, typically in about 1 min. © 2000 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 38: 2767–2778, 2000 相似文献
12.
《Journal of separation science》2018,41(6):1298-1306
For the enantioselective and simultaneous analysis of lactate and 3‐hydroxybutyrate, a validated online two‐dimensional high‐performance liquid chromatography system using 4‐nitro‐7‐piperazino‐2,1,3‐benzoxadiazole as a fluorescent derivatization reagent has been developed. For the reversed‐phase separation in the first dimension, a Capcell Pak C18 ACR column (1.5 × 250 mm, particle size 3 μm) was used, and the target fractions were isolated by their hydrophobicity. In the second dimension, a polysaccharide‐coated enantioselective column, Chiralpak AD‐H (2.0 × 250 mm, 5 μm), was used. The system was validated by the calibration curve, intraday precision, interday precision, and accuracy using standards and real human samples, and satisfactory results were obtained. The present method was applied to human plasma and urine, and in the plasma, trace amounts of d‐ lactate (8.4 μM) and l‐ 3‐hydroxybutyrate (1.0 μM), besides high levels of l‐ lactate (860.9 μM) and d‐ 3‐hydroxybutyrate (59.4 μM), were successfully determined. In urine, trace levels of d‐ lactate (3.7 μM), d‐ 3‐hydroxybutyrate (2.3 μM), and l‐ 3‐hydroxybutyrate (3.3 μM) in addition to a relatively large amount of l‐ lactate (15.4 μM) were observed. The present online two‐dimensional high‐performance liquid chromatography system is useful for the simultaneous determination of all the lactate and 3‐hydroxybutyrate enantiomers in human physiological fluids, and further clinical applications are ongoing. 相似文献
13.
Analysis of normal and modified nucleosides in urine samples by high‐performance liquid chromatography with different stationary phases 下载免费PDF全文
The main aim of the present work was to study the retention behavior and quantification of nine nucleosides with the use of octadecyl, alkylamide, cholesterol and alkyl‐phosphate stationary phases. The influence of organic solvent and buffer concentration on the separation of these compounds was under investigation. The retention factor had the highest values for the octadecyl and cholesterol packing materials. Complete separation of all the studied nucleosides was achieved in case of cholesterol stationary phase. The optimized separation method was applied for the quantification of nucleosides in the urine samples. Calibration plots showed good linearity (R2 > 0.999) and the limits of detection were in a range of 0.3–0.5 µg/mL, while the limits of quantitation were >0.9 µg/mL. Accuracy was in the range of 5–11%. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
14.
Vitria L. Louros Diana L.D. Lima Jorge H. Leito Valdemar I. Esteves Helena G. Nadais 《Journal of separation science》2019,42(8):1585-1592
Estrone, 17β‐estradiol and 17α‐ethinylestradiol are increasingly recognised as important micropollutants to be monitored in wastewater treatment plants. These estrogens are retained onto sludge due to their high adsorption and since they are largely used in land applications, the monitoring of these chemicals in sludge samples is of great importance. This study describes a method for the determination of estrone and 17α‐ethinylestradiol in fresh sludge samples. After spiking fresh digested sludge with estrone and 17α‐ethinylestradiol and maintaining in contact during 5, 30 and 60 min, the freeze‐dried samples were subjected to ultrasonic liquid extraction, with methanol and acetone, and analysed by high‐performance liquid chromatography with fluorescence detection. The average recoveries obtained for estrone and 17α‐ethinylestradiol using the different contact times were 103 ± 3 and 97 ± 4%, respectively. Fresh sludge samples from one waste water treatment plant located in Portugal were analysed and estrone was detected in primary fresh sludge, anaerobic digested sludge and dehydrated sludge at a concentration in the range of 1–4.8 μg/g. The method here developed does not require any sample clean‐up, being fast and simple, reliable and inexpensive, making possible its application for monitoring the contamination of sludge with these estrogens. 相似文献
15.
Three‐phase hollow‐fiber microextraction combined with ion‐pair high‐performance liquid chromatography for the simultaneous determination of five components of compound α‐ketoacid tablets in human urine 下载免费PDF全文
Zaifa Pan Xiaoya Huang Yuan Zhong Lili Wang Danhua Zhu Lanjuan Li 《Journal of separation science》2015,38(9):1499-1506
The determination of α‐ketoacid concentration is demanded to evaluate the absorption and metabolic behavior of compound α‐ketoacid tablets taken by chronic kidney disease patients. To eliminate the interference of endogenous substance of urine and enrich the analytes, a three‐phase hollow‐fiber liquid‐phase microextraction combined with ion‐pair high‐performance liquid chromatography method was established for the determination of d ,l ‐α‐hydroxymethionine calcium, d ,l ‐α‐ketoisoleucine calcium, α‐ketovaline calcium, α‐ketoleucine calcium, and α‐ketophenylalanine calcium of compound α‐ketoacid tablets in human urine samples. The extraction parameters, such as organic solvent, pH of donor phase and acceptor phase, stirring rate, and extraction time were optimized. Under the optimal conditions, the obtained enrichment factors were up to 11‐, 110‐, 198‐, 202‐, and 50‐fold, respectively. The calibration curves for these analytes were linear over the range of 0.1–10 mg/L for α‐ketovaline calcium, d ,l ‐α‐ketoisoleucine calcium, and α‐ketoleucine calcium, 0.5–10 mg/L for d ,l ‐α‐hydroxymethionine calcium, and α‐ketophenylalanine calcium with r > 0.99. The relative standard deviations (n = 5) were less than 6.27% and the LODs were 100.7, 10.0, 5.8, 7.8, and 8.6 μg/L (based on S/N = 3), respectively. Good recoveries from spiked urine samples (92–118%) were obtained. The proposed method demonstrated excellent sample clean‐up and analytes enrichment to determine the five components in human urine. 相似文献
16.
《Journal of separation science》2018,41(7):1524-1531
Nanoliter high‐performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high‐performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high‐pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high‐performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high‐performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9–1.8 μg/L were obtained with precisions variable in the range of 1.6–4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87–102%). 相似文献
17.
混合模式毛细管整体色谱柱由于保留机理多样,具有很好的应用前景。本文以[2-(甲基丙烯酰基氧基)乙基]二甲基-(3-磺酸丙基)氢氧化铵(SPE)为单体,乙二醇二甲基丙烯酸酯(EDMA)为交联剂,偶氮二异丁腈(AIBN)为引发剂,正丙醇/1,4-丁二醇/水三元体系为致孔剂,制备了聚合物基质SPE-co-EDMA毛细管液相色谱整体柱。通过系统优化致孔剂和反应物种类和配比、引发剂的用量、反应时间和反应温度等因素,提高了整体柱的柱效、机械强度、渗透性和重复性。结果表明该毛细管整体柱在10 MPa内具有良好的机械强度,渗透性为2.17×10-14 m2,而且批次内和批次间峰面积的重现性(RSD)分别为1.0%和4.6%。以极性和非极性的多种化合物评价了该毛细管整体柱的色谱性能,结果表明该柱在高有机相中具有亲水相互作用机理,在低有机相中具有反相作用机理,显示出混合模式分离特性。 相似文献
18.
Study of tamoxifen urinary metabolites in rat by ultra‐high‐performance liquid chromatography time‐of‐flight mass spectrometry 下载免费PDF全文
Juan C. Domínguez‐Romero Juan F. García‐Reyes Miriam Beneito‐Cambra Rubén Martínez‐Romero Esther Martinez‐Lara María L. Del Moral‐Leal Antonio Molina‐Díaz 《Biomedical chromatography : BMC》2015,29(8):1220-1228
Tamoxifen (TMX) is a nonsteroidal estrogen antagonist drug used for the treatment of breast cancer. It is also included in the list of banned substances of the World Anti Doping Agency (WADA) prohibited in and out of competition. In this work, the excretion of urinary metabolites of TMX after a single therapeutic dose administration in rats has been studied using ultra‐high‐performance liquid chromatography electrospray time‐of‐flight mass spectrometry (UHPLC‐TOFMS). A systematic strategy based on the search of typical biotransformations that a xenobiotic can undergo in living organisms, based on their corresponding molecular formula modification and accurate mass shifts, was applied for the identification of TMX metabolites. Prior to UHPLC‐TOFMS analyses, a solid‐phase extraction step with polymeric cartridges was applied to urine samples. Up to 38 TMX metabolites were detected. Additional collision induced dissociation (CID) MS/MS fragmentation was performed using UHPLC‐QTOFMS. Compared with recent previous studies in human urine and plasma, new metabolites have been reported for the first time in urine. Metabolites identified in rat urine include the oxygen addition, owing to different possibilities for the hydroxylation of the rings in different positions (m/z 388.2271), the incorporation of two oxygen atoms (m/z 404.2220) (including dihydroxylated derivatives or alternatives such as epoxidation plus hydroxylation or N‐oxidation and hydroxylation), epoxide formation or hydroxylation and dehydrogenation [m/z 386.2114 (+O –H2)], hydroxylation of the ring accompanied by N‐desmethylation (m/z 374.2115), combined hydroxylation and methoxylation (m/z 418.2377), desaturated TMX derivate (m/z 370.2165) and its N‐desmethylated derivate (m/z 356.2009), the two latter modifications not previously being reported in urine. These findings confirm the usefulness of the proposed approach based on UHPLC‐TOFMS. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
19.
Fang Tian Xiao‐Fang He Jie Sun Xin‐Dan Liu Ying Zhang Hui Cao Meng‐Hua Wu Zhi‐Guo Ma 《Journal of separation science》2020,43(4):736-747
In this study, we aim to determine the chemical constituents of six Chinese medicinal materials from the Citrus genus using high‐performance liquid chromatography and high‐resolution mass spectrometry. Eight flavonoids and one coumarin were identified and further quantified as marker substances by high‐performance liquid chromatography method. The separation was performed on an Agilent TC‐C18 column with 0.1% formic acid and acetonitrile as the mobile phase under gradient elution. The analytical method was fully validated in terms of linearity, sensitivity, intra‐ and inter‐day precision and repeatability, limit of detection, limit of quantitation, and recovery. It was subsequently applied to evaluate the quality of 103 batches of the Chinese medicinal materials from the Citrus genus. In addition, the principal constituent analysis was used to compare the samples of different species from the Citrus genus leading to successful classification of the samples in accordance with their origins. It was found that the contents of nine constituents varied greatly in different ripening stages and varieties of the samples from the Citrus genus. In addition, neoeriocitrin and 5,7‐dimethoxycoumarin were determined as two unique constituents of ‘Zhiqiao’ and ‘Foshou’, respectively. In conclusion, this study provides a chemical basis for quality control of Chinese medicinal materials from the Citrus genus. 相似文献
20.
Xu Deng Jinju Xu Chaoying Tong Fangying Shi Shuyun Shi 《Journal of separation science》2020,43(8):1406-1414
Roots of Ophiopogon japonicus have been used as a functional food ingredient and traditional Chinese medicine for a long time in China. Homoisoflavonoids are one of the major kinds of bioactive compounds in O. japonicus; however, literature data about its homoisoflavonoids profile are scarce because of the complex ingredients with low abundance. Here, homoisoflavonoid fraction was prepared by petroleum ether extraction. Then, a high‐speed countercurrent chromatography off‐line coupling with high‐performance liquid chromatography–diode array detector?quadrupole time‐of‐flight tandem mass spectrometry was developed for systematic identification of homoisoflavonoids. After that, 39 homoisoflavonoids, including 29 homoisoflavanone and 10 homoisoflavone, were unambiguously or tentatively identified, while 12 of them were reported in O. japonicus for the first time. Finally, eight available homoisoflavonoids were sensitively, precisely, and accurately determined by standard calibration curves, with limit of detection and limit of quantification in the range of 0.05–0.30 μg/mL and 0.12–0.66 μg/mL, relative standard deviation less than 7.3% for intra‐ and interday variations, and recovery at 94.5–105.2%. Collectively, our developed method is efficient, reliable, and valuable to profile chemical components of complex natural products. 相似文献