首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A highly selective, sensitive and accurate HPLC method has been developed and validated for the estimation of four proton‐pump inhibitors (PPI), lansoprazole (LPZ), omeprazole (OPZ), pantoprazole (PPZ) and rabeprazole (RPZ), with 500 µL human plasma using zonisamide as an internal standard (IS). The sample preparation involved simple liquid–liquid extraction of LPZ, OPZ, PPZ and RPZ and IS from human plasma with ethyl acetate. The baseline separation of all the peaks was achieved with 0.1% triethylamine (pH 6.0):acetonitrile (72:28, v/v) at a flow rate of 1 mL/min on a Zorbax C8 column. The total chromatographic run time was 11.0 min and the simultaneous elution of IS, OPZ, RPZ, PPZ and LPZ occurred at approximately 2.42, 4.45, 5.02 and 9.37 min, respectively. The method was proved to be accurate and precise at linearity range of 20.61–1999.79 ng/mL with a correlation coefficient (r) of ≥0.999. The limit of quantitation for each of the PPI studied was 20.61 ng/mL. The intra‐ and inter‐day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
A sensitive, specific and efficient high‐performance liquid chromatography/tandem mass spectrometry assay for the simultaneous determination of vinorelbine and its metabolite 4‐O‐deacetylvinorelbine in human and mouse plasma is presented. Heated electrospray ionization was applied followed by tandem mass spectrometry. A 50 µL plasma aliquot was protein precipitated with acetonitrile–methanol (1:1, v/v) containing the internal standard vinorelbine‐d3 and 20 µL volumes were injected onto the HPLC system. Separation was achieved on a 50 × 2.1 mm i.d. Xbridge C18 column using isocratic elution with 1 mm ammonium acetate–ammonia buffer pH 10.5–acetonitrile–methanol (28:12:60, v/v/v) at a flow rate of 0.4 mL/min. The HPLC run time was 5 min. The assay quantifies both vinorelbine and 4‐O‐deacetylvinorelbine from 0.1 to 100 ng/mL using sample volumes of only 50 µL. Mouse plasma samples can be quantified using calibration curves prepared in human plasma. Validation results demonstrate that vinorelbine and 4‐O‐deacetylvinorelbine can be accurately and precisely quantified in human and mouse plasma with the presented method. The assay is now in use to support (pre‐)clinical pharmacologic studies with vinorelbine in humans and mice. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A selective and sensitive high‐performance liquid chromatography method with fluorescence detection for simultaneous determination of irbesartan, losartan and valsartan on dried blood spots (DBS) has been developed and validated. It involves solvent extraction of a punch of DBS followed by reversed‐phase liquid chromatography on a Lichrospher® 100 RP‐18e column. Fluorescence detection was performed at 259 and 385 nm as excitation and emission wavelengths, respectively. The detection limits of irbesartan, losartan and valsartan were 1.8, 3.6 and 1.8 ng/mL respectively. The mean recoveries of irbesartan, losartan and valsartan were 98.68, 98.42 and 97.81%, respectively. The mean inter‐day and intra‐day precisions of irbesartan, losartan and valsartan were 2.07 and 1.34%, 1.42 and 1.48%, and 3.20 and 2.15% respectively. The proposed method was simple and rapid. Design of experiments was used to evaluate the robustness of the method. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
Ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) is a preeminent analytical tool for rapid biomedical analysis with the objective of reducing analysis time and maintaining good efficiency. In this study a simple, rapid, sensitive and specific ultra-performance liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan and hydrochlorthiazide in human plasma. After a simple protein precipitation using methanol and acetonitrile, irbesartan, hydrochlorthiazide and internal standard (IS) telmisartan were separated on Acquity UPLC BEH? C18 column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA) using a mobile phase consisting of acetonitrile:10 mM ammonium acetate:formic acid (85:15:0.1 % v/v/v) pumped at a flow rate of 0.3 mL/min and detected by tandem mass spectrometry with negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2 → 193.08 for irbesartan, m/z 295.93 → 268.90 for hydrochlorthiazide and m/z 513.2 → 287.14 for IS. The assay exhibited a linear dynamic range of 30–500 ng/mL for irbesartan and 1–500 ng/mL in human plasma with good correlation coefficient of (0.996) and (0.997) and with a limit of quantitation of 30  and 1 ng/mL for irbesartan and hydrochlorthiazide, respectively. The intra- and inter-assay precisions were satisfactory; the relative standard deviations did not exceed 10.13 % for irbesartan and 11.14 % for hydrochlorthiazide. The proposed UPLC–MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.  相似文献   

5.
A simple, rapid, and sensitive HPLC method based on 9H‐fluoren‐9‐ylmethyl chloroformate derivatization for the quantification of sertraline in rat plasma has been developed, requiring a plasma sample of only 0.1 mL, which was deproteinized and derivatized for 5 min in two single steps. The obtained derivative was stable at room temperature and was determined by HPLC using a fluorescence detector. The analytical column was a C(18) column and the mobile phase was acetonitrile and water (80:20, v/v). Calibration curves were linear in the range of 10–500 ng/mL. The limit of detection was approximately 3 ng/mL, and the lower limit of quantification was established at 10 ng/mL. The bias of the method was lower than 10%, and the within day as well as between day, relative standard deviations were lower than 12%. This analytical method was successfully applied to characterize sertraline pharmacokinetics in rats following intravenous (t1/2 = 213 ± 48 min, Cl = 43.1 ± 8.7 mL/min, Vd = 11560 ± 1861 mL) and oral (Cmax = 156 ± 76 ng/mL, tmax = 63.8 ± 16.3 min) administration of 2 and 5 mg, respectively.  相似文献   

6.
This paper describes a sensitive, specific and rapid high‐performance liquid chromatography (HPLC) method for the determination of curcumin in rat plasma. After a simple step of protein precipitation in 96‐well format using acetonitrile containing the internal standard (IS), emodin, plasma samples were analyzed by reverse‐phase HPLC. Curcumin and the IS emodin were separated on a Diamonsil C18 analytical column (4.6 × 100 mm, 5 µm) using acetonitrile–5% acetic acid (75:25, v/v) as mobile phase at a flow rate of 1.0 mL/min. The method was sensitive with a lower limit of quantitation of 1 ng/mL, with good linearity (r2 ≥ 0.999) over the linear range 1–500 ng/mL. All the validation data, such as accuracy and precision, were within the required limits. A run time of 3.0 min for each sample made high‐throughput bioanalysis possible. The assay method was successfully applied to the study of the pharmacokinetics of curcumin liposome in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
A hydrophilic interaction chromatography‐tandem mass spectrometric method (HILIC/MS/MS) for the determination of irbesartan in human plasma was developed. Irbesartan and losartan (internal standard) were extracted from human plasma with ethyl acetate at acidic pH. The analytes were analyzed on a Luna HILIC column with the mobile phase of ACN–ammonium formate (50 mM, pH 6.5) (96:4, v/v) and detected by ESI MS/MS in the selected reaction monitoring mode. The standard curve was linear (r2 = 0.9981) over the concentration range of 10–2500 ng/mL and the lower LOQ was 10 ng/mL using 100 μL of plasma sample. The CV and relative error for intra‐ and interassay at four QC levels were 2.9 to 8.1% and –2.7 to 2.3%, respectively. There were less absolute and relative matrix effects for irbesartan and losartan. The present method was successfully applied to the pharmacokinetic study of irbesartan after oral dose of irbesartan (150 mg tablet) to male healthy volunteers.  相似文献   

8.
A simple, rapid, selective, accurate and precise method is described for the determination of risperidone and its active metabolite, 9‐hydroxyrisperidone, in plasma using a chemical derivative of risperidone (methyl‐risperidone) as the internal standard. The sample workup involved a single‐step extraction of 1 mL plasma, buffered to pH 10, with heptane–isoamyl alcohol (98:2 v/v), then evaporation of the heptane phase and reconstitution of the residue in mobile phase. HPLC separation was carried out at on C18 column using a mobile phase of 0.05 m dipotassium hydrogen orthophosphate (containing 0.3% v/v triethylamine) adjusted to pH 3.7 with orthophosphoric acid (700 mL), and acetonitrile (300 mL). Flow rate was 0.6 mL/min and the detection wavelength was 280 nm. Retention times were 2.6, 3.7 and 5.8 min for 9‐hydroxy risperidone, risperidone and the internal standard, respectively. Linearity in spiked plasma was demonstrated from 2 to 100 ng/mL for both risperidone and 9‐hydroxyrisperidone (r ≥ 0.999). Total imprecision was less than 13% (determined as co‐efficient of variation) and the inaccuracy was less than 12% at spiked concentrations of 5 and 80 ng/mL. The limit of detection, determined as three times the baseline noise, was 1.5 ng/mL. Clinical application of the assay was demonstrated for analysis of post‐dose (0.55–4.0 mg/day) samples from 28 paediatric patients (aged 6.9–17.9 years) who were taking risperidone orally for behavioural and emotional disorders. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection for the quantification of vancomycin in human plasma was developed and validated. The method includes an extraction of vancomycin by deproteinization with acetonitrile. The analyses were carried out at 258 nm as the emission wavelength while exciting at 225 nm on a reversed-phase column (30 cm × 4 mm i.d. × 10 μm Waters Associates μBondapak C18) using a mobile phase composed of methanol and phosphate buffer at pH 6.3. Vancomycin was quantitatively recovered from human plasma samples (>96%) with high values of precision. The separation was completed within 27 min. The calibration curve was linear over the range from 5 to 1,000 ng/mL with the detection and quantification limits of 2 ng/mL and 5 ng/mL, respectively. This method is suitable for the routine assay of plasma samples. Figure The effect of the deproteinization solvent on the signal of the interference peak at retention time of 15.0 min. The peak which interferes with the peaks of Erythromycin and Vancomycin has been disappeared by using 2 mL acetonitrile as the deproteinization solvent.  相似文献   

10.
A simple, specific, sensitive, validated method was developed using liquid chromatography with tandem mass spectrometry with electrospray ionization of human plasma for the simultaneous estimation of drugs (simvastatin, ramipril, atenolol, hydrochlorothiazide, and aspirin) of PolycapTM capsule used in cardiovascular therapy. The interaction of these actives including internal standards between the stationary and mobile phase were investigated using Hansen solubility parameters. Chromatographic separation was performed on Phenomenex Synergi Polar‐RP (30 × 2 mm, 4 μm) column with a gradient mobile phase composition of acetonitrile and 5 mM ammonium formate for positive mode and 0.1% formic acid in both water and acetonitrile for negative mode. The flow rate and runtime were 1.0 mL/min and 3.5 min, respectively. Sample extraction was done by protein precipitation using acetonitrile, enabling a fast analysis. The calibration ranges from 0.1 to 100, 0.1 to 100, and 1 to 1000 ng/mL for simvastatin, ramipril, and atenolol using internal standard carbamazepine in positive mode, respectively, whereas it was 0.3–300 and 2–2000 ng/mL for hydrochlorothiazide and aspirin using internal standard 7‐hydroxy coumarin in negative mode, respectively. Hansen solubility parameters can be used as a high‐throughput optimizing tool for column and mobile phase selection in bioanalysis. This validated bioanalytical method has the potential for future fixed dose combination based preclinical and clinical studies that can save analysis time.  相似文献   

11.
A highly sensitive, rapid assay method has been developed and validated for the estimation of montelukast (MTK) in human plasma with liquid chromatography coupled to tandem mass spectrometry with electro spray ionization in the positive‐ion mode. Liquid–liquid extraction was used to extract MTK and amlodipine (internal standard, IS) from human plasma. Chromatographic separation was achieved with 10 mm ammonium acetate (pH 6.4): acetonitrile (15:85, v/v) at a flow rate of 0.50 mL/min on a Discovery HS C18 column with a total run time of 3.5 min. The MS/MS ion transitions monitored were 586.10 → 422.10 for MTK and 409.20 → 238.30 for IS. Method validation and clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.25 ng/mL and linearity was observed from 0.25 to 800 ng/mL. The intra‐day and inter‐day precisions were 5.97–8.33 and 7.09–10.13%, respectively. This novel method has been applied to a pharmacokinetic study of MTK in humans. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A simple, specific and sensitive HPLC method has been developed for the determination of metoprolol in human plasma and urine. Separation of metoprolol and atenolol (internal standard) was achieved on an Ace C18 column (5 μm, 250 mm×4.6 mm id) using fluorescence detection with λex=276 nm and λem=296 nm. The mobile phase consists of methanol–water (50:50, v/v) containing 0.1% TFA. The analysis was performed in less than 10 min with a flow rate of 1 mL/min. The assay was linear over the concentration range of 3 – 200 and 5 – 300 ng/mL for plasma and urine, respectively. The LOD were 1.0 and 1.5 ng/mL for plasma and urine, respectively. The LOQ were 3.0 and 5.0 ng/mL for plasma and urine, respectively. The extraction recoveries were found to be 95.6 ± 1.53 and 96.4 ± 1.75% for plasma and urine, respectively. Also, the method was successfully applied to three patients with hypertension who had been given an oral tablet of 100 mg metoprolol.  相似文献   

13.
A high‐throughput, simple, highly sensitive and specific LC‐MS/MS method has been developed for simultaneous estimation of simvastatin acid (SA), amlodipine (AD) and valsartan (VS) with 500 µL of human plasma using deuterated simvastatin acid as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode (MRM) using electrospray ionization. The assay procedure involved precipitation of SA, AD, VS and IS from plasma with acetonitrile. The total run time was 2.8 min and the elution of SA, AD, VS and IS occurred at 1.81, 1.12, 1.14 and 1.81 min, respectively; this was achieved with a mobile phase consisting of 0.02 m ammonium formate (pH 4.5):acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on an X‐Terra C18 column. A linear response function was established for the range of concentrations 0.5–50 ng/mL (> 0.994) for VS and 0.2–50 ng/mL (> 0.996) for SA and AD. The method validation parameters for all three analytes met the acceptance as per FDA guidelines. This novel method has been applied to human pharmacokinetic study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
A specific, sensitive and accurate analytical LC‐MS/MS assay was developed for the simultaneous determination of two steroidal glycosides, tenacissoside H and tenacissoside I, in rat plasma. An Agilent ZORBAX SB‐C18 column was used with an isocratic mobile phase system composed of methanol–water–formic acid (70:30:0.1, v/v/v) at a flow rate of 0.3 mL/min. The analysis was performed on a positive ionization electrospray mass spectrometer via selected reaction monitoring mode scan. One‐step protein precipitation with acetonitrile was chosen to extract the analytes from plasma. The lower limits of quantification were 0.9 ng/mL for tenacissoside H and tenacissoside I. The intra‐ and inter‐day precisions were 2.03–11.56 and 3.76–11.62%, respectively, and the accuracies were <110.28% at all quality control levels. The validated method was applied to a pharmacokinetic study in rats after oral gavage of Marsdenia tenacissima extract. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
In this study, a sensitive HPLC‐UV assay was developed and validated for the determination of LASSBio‐1736 in rat plasma with sodium diclofenac as internal standard (IS). Liquid–liquid extraction using acetonitrile was employed to extract LASSBio‐1736 and IS from 100 μL of plasma previously basified with NaOH 0.1 M. Chromatographic separation was carried on Waters Spherisorb®S5 ODS2 C18 column (150 × 4.6 mm, 5 μm) using an isocratic mobile phase composed by water with triethylamine 0.3% (pH 4), methanol and acetonitrile grade (45:15:40, v/v/v) at a flow rate of 1 mL/min. Both LASSBio‐1736 and IS were eluted at 4.2 and 5 min, respectively, with a total run time of 8 min only. The lower limit of quantification was 0.2 μg/mL and linearity between 0.2 and 4 μg/mL was obtained, with an R2 > 0.99. The accuracy of the method was >90.5%. The relative standard deviations intra and interday were <6.19 and <7.83%, respectively. The method showed the sensitivity, linearity, precision, accuracy and selectivity required to quantify LASSBio‐1736 in preclinical pharmacokinetic studies according to the criteria established by the US Food and Drug Administration and European Medicines Agency. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
Theophylline, tolbutamide, mephenytoin, debrisoquin, and dapsone are marker substrates for CYP1A2, CYP2C9, CYP2C19, CYP2D6, and CYP3A4, respectively. A silica‐based monolithic column (Chromolith SpeedROD RP‐18e, 50×4.6 mm) was used to separate these five marker substrates of cytochrome P450 within only 84 s. Linear gradient elution was from acetonitrile‐water‐formic acid (10 : 90 : 1, v/v/v) to acetonitrile‐water‐formic acid (90 : 10 : 1, v/v/v) in 1.4 min. The flow rate was 2.5 mL/min. The retention time was 0.52 min for theophylline, 0.67 min for debrisoquin, 0.78 min for dapsone, 0.96 min for mephenytoin, and 1.13 min for tolbutamide. Detection was by tandem mass spectrometry using a PE Sciex API 3000 mass spectrometer with a Turbo‐Ionspray source in positive mode. A simple protein precipitation method was used. This method was validated over the concentration range of 5–2000 ng/mL based on the sample volume of 0.1 mL.  相似文献   

17.
A simple, rapid and sensitive fluorescence high performance liquid chromatographic method was developed to determine propranolol concentration in the small volume of rat plasma without the solvent extraction step using pronethanol as the internal standard. The analysis was accomplished using a 5 microm CAPCELL PAK analytical cyano column at room temperature and a mobile phase consisted of 1% aqueous acetic acid containing 0.2% triethylamine and acetonitrile (65:35, v/v; pH 3.8). The flow-rate was kept at 0.5 mL/min and column effluent was monitored with a fluorescence detector at an excitation wavelength of 230 nm and an emission wavelength of 340 nm. Retention times for pronethalol and propranolol were 8.5 min and 10.5 min, respectively. Linear regressions for the standard curves were linear in the range 2-800 ng/mL, giving correlation coefficients above 0.998. The detection limit was 1.34 ng/mL. No analytical interference was observed from endogenous components in rat plasma. This simple and sensitive assay method was feasibly applied to the pharmacokinetic study of propranolol after intravenous administration of 2 mg/kg of propranolol to normal and carbon tetrachloride-induced liver cirrhotic rats.  相似文献   

18.
A highly sensitive and rapid bioanalytical method has been developed and validated for the estimation of indomethacin in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of indomethacin and phenacetin (internal standard, IS) from rat plasma with acetonitrile. Chromatographic separation was achieved with 0.2% formic acid–acetonitrile (25:75, v/v) at a flow rate of 0.60 mL/min on an Atlantis dC18 column with a total run time 3.0 min. The MS/MS ion transitions monitored were 357.7 → 139.1 for indomethacin and 180.20 → 110.10 for IS. Method validation and pharmacokinetic study plasma analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.51 ng/mL and the linearity was observed from 0.51 to 25.5 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.00–10.2 and 5.88–9.80%, respectively. This novel method has been applied to an oral pharmacokinetic study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
Ferruginol, a diterpene phenol, has recently received attention for its extensive pharmacological properties, including anti‐tumor, antibacterial, cardio‐protective and gastroprotective effects. In the present study, a high‐performance liquid chromatographic (HPLC) method was developed for determination of ferruginol in rat plasma and applied for the pharmacokinetics study. The HPLC assay was performed with a VP ODS‐C18 column. The mobile phaseconsisted of methanol and 1% acetic acid solution (90:10, v/v). The flow rate was 1.0 mL/min, and the wavelength was set at 270 nm. This method was linear over the studied range of 0.1–10.0 µg/mL for ferruginol. The correlation coefficient was 0.9998. The intra‐day and inter‐day precisions were better than 4 and 5%, respectively. The extraction recovery and accuracy were greater than 97 and 96%, respectively. The detection limit was 30 ng/mL. The mean maximum concentration of ferruginol in rat plasma was 3.14 µg/mL at 40 min after oral administration at a dose of 20 mg/kg. Ferruginol was absorbed quickly p.o. with t1/2ka = 14.86 min and had a high rate of elimination with t1/2 = 41.73 min. The pharmacokinetic process of ferruginol in rat was well described with a one‐compartment model. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
 A simple, selective, sensitive, precise, simultaneous high performance liquid chromatographic analysis of serum samples and commercial tablet formulation containing hydrochlorothiazide, olmesartan medoxomil and irbesartan are reported. Good chromatographic separation was achieved using a μ-Bondapak, C18 column (15 cm×4.6 mm, 5 μm), and a mobile phase consisting of acetonitrile-0.2% acetic acid aqueous solution (50∶50, v/v) at a flow rate of 1.0 mL/min. The ultraviolet detector was set at a wavelength of 260 nm. Hydrochlorothiazide, olmesartan medoxomil, and irbesartan were eluted at 1.2, 3.8, and 4.4 min, respectively. No extraneous materials were found to interfere. The method uses protein precipitation with acetonitrile for the preparation of serum sample. The linear ranges for hydrochlorothiazide, olmesartan medoxomil, and irbesartan were 6.25-18.75, 20-60, and 75-225 ng/mL, respectively. The recoveries of hydrochlorothiazide, olmesartan medoxomil, and irbesartan in spiked samples were all greater than 98%, and their relative standard deviations were less than 2.0%. The limits of detection were 1, 2, and 2 ng/mL for hydrochlorothiazide, olmesartan medoxomil, and irbesartan, respectively, and the limits of quantification were 3 ng/mL, which allow their determination at the expected serum concentration levels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏