首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Compact Dry CF is a ready-to-use test method for the enumeration of coliform bacteria in food. The plates are presterilized and contain culture medium and a cold water-soluble gelling agent. The medium should be rehydrated with 1 mL diluted sample inoculated into the center of the self-diffusible medium, allowing the solution to diffuse by capillary action. The plate can be incubated at 35 degrees C for 20-24 h and the colonies counted without any further working steps. The Compact Dry CF medium plates were validated with 5 different raw meats. The performance tests were conducted at 35 degrees C. In all studies performed, no apparent differences were observed between the Compact Dry CF method and the AOAC Official Method 966.24 results. For the accuracy claim (n = 75), a correlation factor of r2 = 0.91 (coliform) could be assigned, as stated in the application for Performance-Tested Method. No significant variations in coliform bacterial counts were observed with different production lots or plates of diverse storage age by the quality consistency and storage robustness studies.  相似文献   

2.
Compact Dry E. coli/Coliform Count (EC) is a ready-to-use test method for the enumeration of Escherichia coli and coliform bacteria in food. The plates are presterilized and contain culture medium and a cold water-soluble gelling agent. The medium should be rehydrated with 1 mL diluted sample inoculated onto the center of the self-diffusible medium, allowing the solution to diffuse by capillary action. The plate can be incubated at 35 degrees C for 20-24 h and the colonies counted without any further working steps. The Compact Dry EC medium plates were validated as an analysis tool for determining colony-forming units (CFU) of E. coli and coliform bacteria from a variety of raw meats using 5 different types of raw meats. The performance tests were conducted at 35 degrees C. In all studies performed, no apparent differences were observed between the Compact Dry EC method and the AOAC Official Method 966.24 results. For the accuracy claim (n = 75), a correlation factor of r2 = 0.93 (E. coli) and r2 = 0.93 (coliform bacteria) could be assigned, as stated in the application for "Performance-Tested Method."  相似文献   

3.
Compact Dry YM is a ready-to-use test method for the enumeration of yeasts and molds in fruit-based products. The plates are presterilized and contain nonwoven incorporated nutrients supplemented with antibiotics and a chromogenic enzyme substrate, 5-bromo-4-chloro-3-indoxyl phosphate, p-toluidine salt (X-phos), to facilitate counting dyes, and a cold water-soluble gelling agent. The medium should be rehydrated with 1 mL of diluted sample inoculated onto the center of the self-diffusible medium, allowing the solution to diffuse immediately by capillary action. The plate can be incubated at 25 degrees C for 7 days. The Compact Dry YM medium plates were validated as an analysis tool determining colony forming units of yeasts and molds from a variety of fruit-based products using 5 different fruit products. The performance tests were conducted at 25 degrees C. In all studies performed, no apparent differences were observed between the Compact Dry YM method and the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA BAM) method results (P > 0.05). For the accuracy claim (n = 75), a correlation factor of r2 = 0.99 could be assigned, as stated in the application for Performance-Tested Method.  相似文献   

4.
The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.  相似文献   

5.
A simple HPLC technique for determining mitragynine levels in serum was developed. The separation system consisted of a C18 column heated to 35 degrees C, a methanol-water (80:20, v/v) mobile phase, a flow rate of 0.8 mL/min and detection in the ultraviolet at 225 nm. Mitragynine, with a retention time of 10.09 min, was well resolved from any interferences in human serum and the internal standard peak. The calibration curve was linear from 0.1 to 10 microg/mL (r = 0.9995). Extraction of mitragy-nine from alkalinized serum using diethyl ether gave a high recovery (>or=85%). The intra- and inter-day precisions of the method were 4.29-5.88%RSD and 7.06-8.45%RSD, respectively. The accuracy ranged from -9.54 to +0.67%DEV. The limit of detection was 0.03 microg/mL and the lower limit of quantification was 0.1 microg/mL. Mitragynine in the stock solution was stable during 30 days of storage at 4 degrees C. This method was successfully applied to determine the pharmacokinetic characteristics of mitragynine levels in the serum of rats after it was administered orally.  相似文献   

6.
A stability-indicating HPLC method with diode array detection for the determination of paricalcitol, a synthetic vitamin D2 analog, was developed. Analytical parameters were studied according to International Conference on Harmonization guidelines. A C18 column (250 x 4.6 mm, 5 microm particle size) maintained at 25 degrees C was used as the stationary phase, and acetonitrile-water (70 + 30, v/v) as the mobile phase. Chromatograms were recorded at 250 nm. In forced degradation studies, the effects of acid, base, oxidation, temperature, and UV light were investigated and showed no interference with the drug peak. The method was found to be linear (r = 0.9989) at concentrations ranging from 0.6 to 10.0 mg/L paricalcitol, precise (repeatability and intermediate precision estimated as RSD less than 3.5%), accurate (recoveries higher than 95%), specific, and robust. The LOD and LOQ were 0.6 and 0.2 mg/L, respectively. The validated method was used for paricalcitol determination in a formal stability study of its pharmaceutical dosage form in preloaded syringes. The stability of a diluted solution of its pharmaceutical form in Viaflo bags was also tested. The results showed that paricalcitol was stable in preloaded syringes during a period of 30 days from preparation in the different storage conditions tested (room temperature without protection from daylight and 4.4 degrees C with protection from daylight). On the contrary, paricalcitol was quickly lost when stored in Viaflo bags by adsorption onto the walls of the container.  相似文献   

7.
The chemical stability of haloperidol lactate injection was studied under different storage conditions by high performance thin-layer chromatography (HPTLC). The study was performed at 25 +/- 2 degrees C and at refrigeration temperature (8 +/- 1 degrees C) in original glass ampoules over 15 days after being opened. The samples tested at 25 +/- 2 degrees C were stored with exposure to and protection from light. Chromatographic separation was achieved on precoated silica gel F 254 HPTLC plates using a mixture of acetone/chloroform/n-butanol/glacial acetic acid/water (5:10:10:2.5:2.5, v/v/v/v/v) as a mobile phase. Quantitative analyses were carried out at a wavelength of 254 nm. The method exhibited adequate linearity (r = 0.999), selectivity, precision (RSD = 1.92%), and accuracy (recoveries from 98.59 to 101.90%). The concentrations of all samples remained greater than or 90% of the original concentration. Haloperidol lactate injection was chemically stable under all conditions studied over 15 days.  相似文献   

8.
The Sanita-kun Coliforms consists of a transparent cover film, an adhesive sheet, a layer of nonwoven fabric, and a water-soluble compound film, including a culture medium formula for the detection of coliforms. The medium sheet was validated with 26 food types belonging to 9 food categories (meat, poultry, fish and seafood, fruits and vegetable, dairy, chocolate or bakery, animal feeds, pasta, and miscellaneous) using violet red bile (VRB) agar method in the U.S. Food and Drug Administration's Bacteriological Analytical Manual as a reference according to the AOAC guideline. The medium sheet showed 100% inclusivity and exclusivity. Ruggedness study suggested allowances in the incubation temperature and time as 33-35 degrees C and 24 +/- 4 h, respectively. The performance of 3 different lots of the medium sheets was equivalent and suggested no change of the performance at least for 3 years. In the comparative recovery study, many samples (84.6%), which were inoculated with a coliform strain, showed no significant difference between the 2 methods. The linear correlation coefficient (r2) to the VRB agar was calculated as 0.94. In the repeatability study, the average relative standard deviation of total foods was 0.10 in the medium sheet. In the independent study, the medium sheet detected significantly more colonies than VRB plates in the frozen raw milk sample, while there was no significant difference between the 2 methods in raw ground beef sample. Comparative recovery study on foods, inoculated and then frozen, showed the medium sheet detected injured cells with better recovery than VRB agar. The analysts in the independent study wrote that the medium sheet was easy to use and read overall. The Sanita-kun sheet provides an alternative method to coliform count agar.  相似文献   

9.
A micellar electrokinetic chromatography (MEKC) method was validated for the analysis of ezetimibe. The method was carried out on a fused-silica capillary (50 microm i.d.; effective length, 40 cm). The background electrolyte consisted of a 25 mM borate buffer and 25 mM anionic detergent SDS (pH 9.75)/methanol (90:10, v/v). The capillary temperature was maintained at 35 degrees C, the applied voltage was 30 kV; the injection was performed using a pressure mode at 50 mbar for 5 s, with detection at 232 nm. The method was linear in the range of 2-150 microg/mL (R2=0.9999). The specificity and the stability-indicating capability were proven through degradation studies, which also showed that there was no interference of the excipients. The limits of quantitation and detection were 2 and 0.41 microg/mL, respectively. The method was applied for the analysis of ezetimibe pharmaceutical formulations, and the results were compared to those of the liquid-chromatography method.  相似文献   

10.
A standard method for the detection of Enterobacteriaceae was modified for the presumptive detection of Enterobacter sakazakii, and the modified method was validated in an interlaboratory trial with 16 laboratories from 8 European countries. The modification included a differential-elective medium for the isolation of E. sakazakii, consisting of nutrient agar (NA) supplemented with 4-methyl-umbelliferyl alpha-D-glucoside (alpha-MUG). A 25 g sample was added to 225 mL buffered peptone water. After incubation at 35 degrees or 37 degrees C for 16 or 20 h, 10 mL nonselective enrichment was transferred into 90 mL selective enrichment. The selective enrichment was streaked on violet-red bile glucose agar (VRBGA) and incubated at 37 degrees C for 24 h. It was streaked in parallel on NA plates supplemented with alpha-MUG at 50 mg/L and incubated at 25 degrees C for 16 h, and afterwards for an additional 24 h at room temperature in the dark. E. sakazakii appeared as vivid yellow colonies under normal light and showed blue/violet fluorescence under UV light on NA + alpha-MUG plates. Validation samples represented powdered infant formula without E. sakazakii (blanks) and with low (1-10 colony-forming units [CFU]/25 g) and medium (1-10 CFU/g) contamination levels. All samples contained Pseudomonas aeruginosa and Lactobacillus spp. as background flora. The specificity for blank samples was 100%. The sensitivity of the low contamination level was similar for VRBGA and NA + alpha-MUG, i.e., 66.7% (66.7% accordance, 53.9% concordance). For the medium level the sensitivities were 96.7% (93.3% accordance, 93.5% concordance) for VRBGA and 98.3% (96.9% accordance, 96.9% concordance) for NA + alpha-MUG.  相似文献   

11.
A CZE method was developed and validated for the analysis of etoricoxib in pharmaceutical dosage forms, using prilocaine as an internal standard. The CZE method was carried out on a fused-silica capillary (50 microm id, effective length 40 cm). The BGE consisted of 25 mM tris-phosphate solution at pH 2.5. The capillary temperature was maintained at 35 degrees C, the applied voltage was 25 kV, the injection was performed using the pressure mode at 50 mbar for 5 s, with detection at 234 nm using a photodiode array detector. The method was linear in the range of 2-150 microg/mL (r(2) = 0.9999). The specificity and stability-indicating capability were proven through the degradation studies and showing also that there was no interference of the excipients of the formulation. The accuracy was 99.49% with RSD of 0.66%. The limits of quantitation and detection were 2 and 0.58 microg/mL, respectively. Moreover, method validation demonstrated acceptable results for the precision, sensitivity, and robustness. The proposed method was successfully applied for the quantitative analysis of etoricoxib pharmaceutical formulations, and the results compared to the HPLC and LC-MS/MS methods, showing nonsignificant difference (p >0.05).  相似文献   

12.
A simple, accurate, and effective capillary electrophoresis method with ultraviolet absorbance detection was developed and validated for the quantitation of the antihistamine fexofenadine in capsules. The separation was performed with an uncoated fused-silica capillary (47 cm x 75 microm id) and was operated at 20 kV potential. Temperature was maintained at 25 degrees C. The run buffer was prepared with 20mM Na2B4O7 x 10 H2O. Software was used for system control, data acquisition, and analysis. Method validation was performed by evaluation of the analytical parameters linearity, precision, accuracy, limits of detection and quantitation, and specificity. The method was linear (r = 0.9999) at concentrations ranging from 20 to 100 microg/mL, precise (relative standard deviation intra-assay = 1.2, 1.6, and 1.8% and interassay = 1.5%); accurate (recovery = 98.1%); and specific. The limits of detection and quantitation were 0.69 and 2.09 microg/mL, respectively. The method was compared to the liquid chromatography method developed previously by the authors for the same drug, and no significant difference was found between the 2 methods in fexofenadine hydrochloride quantitation.  相似文献   

13.
A stability-indicating MEKC was developed and validated for the analysis of rupatadine in tablet dosage forms, using nimesulide as internal standard. The MEKC method was performed on a fused-silica capillary (50 microm id; effective length, 40 cm). The BGE consisted of 15 mM borate buffer and 25 mM anionic detergent SDS solution at pH 10. The capillary temperature was maintained at 35 degrees C and the applied voltage was 25 kV. The injection was performed using the hydrodynamic mode at 50 mbar for 5 s, with detection by photodiode array detector set at 205 nm. The method was linear in the range of 0.5-150 microg/mL (r2=0.9996). The specificity and stability-indicating capability of the method were proven through degradation studies inclusive by MS, and showing also that there was no interference of the excipients and no increase of the cytotoxicity. The accuracy was 99.98% with bias lower than 1.06%. The LOD and LOQ were 0.1 and 0.5 microg/mL, respectively. The proposed method was successfully applied for the quantitative analysis of rupatadine in pharmaceutical formulations, and the results were compared to a validated RP-LC method, showing non-significant difference (p>0.05).  相似文献   

14.
Zhang B  Pan X  Venne L  Dunnum S  McMurry ST  Cobb GP  Anderson TA 《Talanta》2008,75(4):1055-1060
A reliable, sensitive, and reproducible method was developed for quantitative determination of nine new generation pesticides currently used in cotton agriculture. Injector temperature significantly affected analyte response as indicated by electron capture detector (ECD) chromatograms. A majority of the analytes had an enhanced response at injector temperatures between 240 and 260 degrees C, especially analytes such as acephate that overall had a poor response on the ECD. The method detection limits (MDLs) were 0.13, 0.05, 0.29, 0.35, 0.08, 0.10, 0.32, 0.05, and 0.59 ng/mL for acephate, trifuralin, malathion, thiamethozam, pendimethalin, DEF6, acetamiprid, brifenthrin, and lambda-cyhalothrin. This study provides a precision (0.17-13.1%), accuracy (recoveries=88-107%) and good reproducible method for the analytes of interest. At relatively high concentrations, only lambda-cyhalothrin was unstable at room temperature (20-25 degrees C) and 4 degrees C over 10 days. At relatively low concentrations, acephate and acetamiprid were also unstable regardless of temperature. After 10 days storage at room temperature, 30-40% degradation of lambda-cyhalothrin was observed. It is recommended that acephate, acetamiprid, and lambda-cyhalothrin be stored at -20 degrees C or analyzed immediately after extraction.  相似文献   

15.
The Sanita-kun Aerobic Count consists of a transparent cover film, an adhesive sheet, a layer of nonwoven fabric, and a water-soluble compound film, including a culture medium formula for detection of aerobic microorganisms. The Sanita-kun sheet was validated for 14 food categories in an internal study and an independent study was conducted on ground beef and hot dogs. Both studies showed no significant difference in performance between 5 or 8 replicates of the Sanita-kun sheets and AOAC Method 966.23, excluding some lots of foods. The correlation coefficient to plate count agar in the internal accuracy study was 0.99. The average relative standard deviation for repeatability of total foods was 0.26 and 0.19, respectively, excluding < 10 average counts. The ruggedness study, which examined the influence of incubation temperature and period, recommended incubation of the Sanita-kun sheet at 32.5 +/- 2.5 degrees C for 46 +/- 2 h. Comparison of 3 lots of Sanita-kun sheets showed no decrease of performance in the older lot. The shelf-life of the sheet is at least 14 months. The Sanita-kun Aerobic Counts has been granted AOAC Performance Tested Method status.  相似文献   

16.
大气有机物预浓缩用吸附剂富集特性的气相色谱法研究   总被引:3,自引:0,他引:3  
何大森  赵雷  洪许峰  李似姣  沈振陆 《色谱》1997,15(4):274-277
用气相色谱方法研究了吸附剂对大气有机物的富集特性,提出用吸附参数泄漏体积BTV(最大采样体积)以及脱附参数最低脱附温度或最小吹扫体积作为富集指标的新思想,并用冲洗色谱法测定了一些有机物在GDX-301上的特性参数。不同温度的特性参数由1og(BTV)与1/Tc的线性关系外推得到。实验表明,所研究的20种有机物(除了甲醇外)在装有2gGDX-301的采样管和0.14gGDX-301的聚焦管上的最大采样体积分别不小于0.8L(35℃)和0.3L(0℃)。  相似文献   

17.
A new liquid chromatography-mass spectrometry (LC-MS) method is developed and validated for the identification and determination of novel 4,5-diazafluoren-9-one compound. The method employs a Waters XTerra RP-18 column (150 mmx4.6 mm, i.d. 5 microm) with a mobile phase comprised of a (50:50, v/v) mixture of deionized water containing 0.2% acetic acid (solvent A) and methanol (solvent B) at a flow rate of 1 mL/min, at 35 degrees C. The detection is performed with photodiode-array (PDA) set at 210-400 nm and single quadropole mass spectrometer with electrospray ionization (ESI) positive ion mode. The chromatographic separation is achieved in less than 3 min. The linearity is established over the concentration range of 0.1-0.5 mg/mL (r2=1.000). The mean RSD values for intra- and inter-day precision studies are <2%. The recovery of 4,5-diazafluoren-9-one ranged between 99.84 and 99.97%. The limits of detection and quantitation are determined to be 0.58 and 0.1 mg/mL, respectively.  相似文献   

18.
郭晓玲  钱蔚  杨昌金  朱小明 《色谱》1998,16(2):164-166
 用5%Ph-Me-Silicone毛细管色谱柱,FID,二阶程序升温,以正十六烷作为内标物测定速效伤风胶囊中对乙酰氨基酚、咖啡因、马来酸氯苯那敏的含量。浓度线性范围:对乙酰氨基酚4~20g/L,咖啡因0.084~0.42g/L,马来酸氯苯那敏0.15~0.75g/L。平均回收率(n=5):对乙酰氨基酚99.62%(RSD=0.44%)咖啡因96.46%(RSD=1.32%),马来酸氯苯那敏98.55%(RSD=0.65%)。  相似文献   

19.
The formation constants of UO2SO4 (aq), UO2(SO4)2(2-), and UO2(SO4)3(4-) were measured in aqueous solutions from 10 to 75 degrees C by time-resolved laser-induced fluorescence spectroscopy (TRLFS). A constant enthalpy of reaction approach was satisfactorily used to fit the thermodynamic parameters of stepwise complex formation reactions in a 0.1 M Na(+) ionic medium: log 10 K 1(25 degrees C) = 2.45 +/- 0.05, Delta r H1 = 29.1 +/- 4.0 kJ x mol(-1), log10 K2(25 degrees C) = 1.03 +/- 0.04, and Delta r H2 = 16.6 +/- 4.5 kJ x mol(-1). While the enthalpy of the UO2(SO4)2(2-) formation reaction is in good agreement with calorimetric data, that for UO2SO4 (aq) is higher than other values by a few kilojoules per mole. Incomplete knowledge of the speciation may have led to an underestimation of Delta r H1 in previous calorimetric studies. In fact, one of the published calorimetric determinations of Delta r H1 is here supported by the TRLFS results only when reinterpreted with a more correct equilibrium constant value, which shifts the fitted Delta r H1 value up by 9 kJ x mol(-1). UO2(SO 4) 3 (4-) was evidenced in a 3 M Na (+) ionic medium: log10 K3(25 degrees C) = 0.76 +/- 0.20 and Delta r H3 = 11 +/- 8 kJ x mol(-1) were obtained. The fluorescence features of the sulfate complexes were observed to depend on the ionic conditions. Changes in the coordination mode (mono- and bidentate) of the sulfate ligands may explain these observations, in line with recent structural data.  相似文献   

20.
The shell dissolution of various empty hard capsules   总被引:1,自引:0,他引:1  
The shell dissolution properties of gelatine, gelatine/polyethylene glycol (PEG) and hydroxypropyl methylcellulose (HPMC) capsules were studied as a function of temperature, dissolution medium, and after different storage conditions. In any dissolution medium with a pH below or equal to 5.8, HPMC capsule shells dissolved rapidly, and there was no difference in the time in which dissolution occurred in the tested temperature interval of 10 to 55 degrees C. Gelatine and gelatine/PEG capsule shells, generally, did not dissolve at temperatures below 30 degrees C. The shell dissolution time of all capsules tested was prolonged and more variable in mixed phosphate buffer pH = 6.8. The addition of enzymes (pepsin, pancreatin) to any dissolution medium was found not to enhance the differences between the different types of capsules investigated. In practical terms, the results indicated that capsule formulations should not be taken with drinks from the carbonated Cola-type. Gelatine containing capsules should preferably be administered with a warm drink, whereas HPMC capsules could be given with cold or warm drinks. The latter type of capsules should also be preferred for preparations to be taken in the fasted state. A short storage of gelatine containing capsules under hot humid tropical conditions appeared not to alter the dissolution properties of the shells, and changes in disintegration times and dissolution times of formulations filled in such capsules might be a reflection of changes of the powders incorporated rather than of the capsule shells. However, a short storage of HPMC capsules under such conditions appeared to influence the capsule shell matrix.  相似文献   