首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
With systematic studies of pre-column thermalhydrolysis, a method is described for the determination of fivephenoxyl-type N-methylcarbamates (NMCs) (viz., propoxur, carbofuran, 3-hydroxy-carbofuran, carbaryl, and bendiocarb) in vegetables by capillary zone electrophoresis with amperometric detection. Effects of hydrolysis parameters such as alkali medium, temperature, and hydrolysis time, as well as separation conditions, are investigated. Under the optimum conditions, baseline separation of five hydrolysates is achieved within 16 min. Good calibration curves of propoxur, carbofuran, 3-hydroxy-carbofuran, carbaryl, and bendiocarb are obtained from 1.20x10(-7) to 5.00x10(-5) mol/L, and their detection limits (S/N=3) are 1.80x10(-8), 1.50x10(-8), 1.80x10(-8), 2.50x10(-8), and 1.80x10(-8) mol/L, respectively, which is approximately 20 approximately 50-fold more sensitive than those previously reported with a UV method. In the application of vegetable samples, the five NMCs are well determined. Average recoveries of 75 approximately 89% and 86 approximately 100% at fortified levels of 0.05 and 0.80 mg/kg are achieved with relative standard deviations of 2 approximately 6%, respectively. The method is sensitive, reproducible, and provides an alternative means for the analysis of phenoxyl-type NMC pesticide residues.  相似文献   

2.
A multiresidue method based on matrix solid-phase dispersion (MSPD) microextraction was studied to determine the carbamate, benfuracarb, and urea insecticides, diflubenzuron, flufenoxuron hexaflumuron and hexythiazox, used in control of citrus pests. Optimisation of different parameters, such as the type of solid support for matrix dispersion, elution solvents and the clean-up step were carried out. The method used 0.5 g of orange sample, C8 bonded silica as MSPD sorbent and dichloromethane as eluting solvent. Recoveries, at spiked concentrations below the maximum residue levels established by Spanish Government, were between 74 and 84% with relative standard deviations ranging from 2 to 4%. The limits of quantification were from 0.15 to 0.25 microgram/g using high-performance liquid chromatography with UV detection at 200 nm. The method may be useful as a screening protocol for the determination of these newly developed pesticides in citrus samples.  相似文献   

3.
液相色谱法检测水果蔬菜中的烟碱类农药残留   总被引:6,自引:0,他引:6  
建立了果蔬样品中5种烟碱类农药(噻虫嗪、吡虫啉、啶虫脒、噻虫啉、噻虫胺)残留的液相色谱快速检测方法。样品采用乙腈提取,浓缩,水转溶后经ENVI-18固相萃取柱净化,0.02 mol/L NaOH预淋洗除去柱上中等极性干扰物,100%乙腈1 mL洗脱5种烟碱类残留,反相高效液相色谱-二极管阵列检测器检测。在黄瓜空白基质中0.1~1.0 mg/kg的加标浓度范围内,5种农药的回收率为50.8%~108.9%,相对标准偏差(RSD)小于15%;而苹果、梨、香蕉、西红柿和韭菜空白基质在0.1~1.0 mg/kg添加水平下,5种农药的回收率均大于80%,RSD小于11%。所测试的6种果蔬样品中噻虫嗪、噻虫胺、吡虫啉的检出限(LOD)为0.01~0.02 mg/kg,啶虫咪和噻虫啉的LOD为0.03~0.05 mg/kg,方法可满足水果蔬菜中烟碱类农药多残留分析的要求。  相似文献   

4.
A method is described for the determination of chlortetracycline residues in tissue samples. The samples were extracted into a hydrochloric acid - glycine solution and the extracts concentrated and purified on cyclohexyl-bonded reversed-phase cartridges. Any chlortetracycline present was converted to iso-chlortetracycline at pH 12, which was then separated from interfering compounds on a reversed-phase polymeric column using high-performance liquid chromatography with fluorescence detection. The detection and determination limits of the assay were 20 and 50 ng g-1, respectively, making it suitable for statutory residue testing purposes.  相似文献   

5.
A new multi-residue method for determination of pesticide residues in a wide variety of fruit and vegetables, using the National Food Administration (NFA) ethyl acetate extraction and determination by means of LC-MS/MS, is presented. The method includes pesticides normally detected by LC-UV or LC-fluorescence such as benzimidazoles, carbamates, N-methylcarbamates and organophosphorus compounds with an oxidisable sulphide group as well. After extraction with ethyl acetate, the extract is concentrated and an aliquot of the extract is evaporated to dryness and redissolved in methanol before injection on LC-MS/MS. The method has been validated for 57 different pesticides and metabolites. Representative species from different commodity groups were chosen as matrices in order to study the influence from different matrices on recoveries. The fortification levels studied were 0.01-0.5 mg kg(-1). Matrix effects were tested for all matrices by means of standard addition to blank extracts. The matrix effect, expressed as signal in solvent compared to signal in matrix, was in general found to be small. The obtained recoveries are, with a few exceptions, in the range 70-100%. The proposed method is quick and straightforward and no additional clean-up steps are needed. The method can be used for the analysis of all 57 pesticides in one single determination step at 0.01 mg kg(-1).  相似文献   

6.
A multiresidue method based on extraction with ethyl acetate has been used at the Swedish National Food Administration since 1989 to monitor pesticide residues in fruit and vegetables. The method has been continuously adjusted, resulting in simple and quick analyses of pesticide residues. To recover basic pesticides, the addition of an alkali is necessary. The addition of sodium hydrogen carbonate has been shown to recover all pesticides effectively without any degradation. The liquid chromatography (LC) with tandem mass spectrometry (MS/MS) technique has made it possible to analyse more polar pesticides and to replace many single methods. The latest development in the multiresidue method, comprising the use of gas chromatography (GC) with MS/MS, has further improved the analysis by replacing the conventional GC detectors. The need for cleanup has been reduced or eliminated entirely. Consequently, the method has been simplified in a way that makes it possible to recover all included analytes in many different matrices in one single extraction and to detect them either with GC-MS/MS or with LC-MS/MS.  相似文献   

7.
Nano-LC and conventional HPLC techniques were applied for the analysis of anthocyanins present in commercial fruit juices using a capillary column of 100 μm id and a 2.1 mm id narrow-bore C(18) column. Analytes were detected by UV-Vis at 518 nm and ESI-ion trap MS with HPLC and nano-LC, respectively. Commercial blueberry juice (14 anthocyanins detected) was used to optimize chromatographic separation of analytes and other analysis parameters. Qualitative identification of anthocyanins was performed by comparing the recorded mass spectral data with those of published papers. The use of the same mobile phase composition in both techniques revealed that the miniaturized method exhibited shorter analysis time and higher sensitivity than narrow-bore chromatography. Good intra-day and day-to-day precision of retention time was obtained in both methods with values of RSD less than 3.4 and 0.8% for nano-LC and HPLC, respectively. Quantitative analysis was performed by external standard curve calibration of cyanidin-3-O-glucoside standard. Calibration curves were linear in the concentration ranges studied, 0.1-50 and 6-50 μg/mL for HPLC-UV/Vis and nano-LC-MS, respectively. LOD and LOQ values were good for both methods. In addition to commercial blueberry juice, qualitative and quantitative analysis of other juices (e.g. raspberry, sweet cherry and pomegranate) was performed. The optimized nano-LC-MS method allowed an easy and selective identification and quantification of anthocyanins in commercial fruit juices; it offered good results, shorter analysis time and reduced mobile phase volume with respect to narrow-bore HPLC.  相似文献   

8.
李岩  郑锋  王明林  庞国芳 《色谱》2009,27(2):127-137
建立了浓缩果蔬汁中156种农药多残留的液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)测定方法。样品用1%醋酸乙腈溶液萃取,经Waters Sep-Pak Vac固相萃取柱净化,乙腈-甲苯(体积比为3∶1)洗脱,旋转蒸发浓缩,用乙腈-水(体积比为3∶2)溶解,以Agilent ZORBAX SB-C18色谱柱分离,以电喷雾电离串联质谱在正离子多反应监测(MRM)模式下进行测定。对156种农药在5种浓缩果蔬汁(橙汁、苹果汁、葡萄汁、白菜汁、胡萝卜汁)中两个添加水平下的回收率进行了测定,回收率范围为57.2%~122.7%,相对标准偏差范围为0.9%~19.8%。方法的检出限(S/N=3)和定量限(S/N=10)范围分别为0.10~56.77 μg/kg和0.33~189.23 μg/kg。该方法样品前处理简单、快速、分析时间短,灵敏度、准确度和精密度均符合农药多残留检测技术的要求,适用于苹果汁、橙汁、葡萄汁、白菜汁、胡萝卜汁等浓缩果蔬汁中156种农药多残留的快速筛查测定。  相似文献   

9.
In this work an analytical method for the determination of abamectin residues in avocados is developed using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A pre-column derivatization with trifluoroacetic anhydride (TFAA) and N-methylimidazole (NMIM) was carried out. The mobile phase consisted of water, methanol and acetonitrile (5:47.5:47.5 v/v/v) and was pumped at a rate of 1 mL/min (isocratic elution). The fluorescence detector was set at an excitation wavelength of 365 nm and an emission wavelength of 470 nm. Homogenized avocado samples were extracted twice with acetonitrile:water 8:2 (v/v) and cleaned using C(18) solid-phase extraction (SPE) cartridges. Recovery values were in the range 87-98% with RSD values lower than 13%. The limits of detection (LODs) and quantification (LOQs) of the whole method were 0.001 and 0.003 mg/kg, respectively. These values are lower than the maximum residue limit (MRL) established by the European Union (EU) and the Spanish legislation in avocado samples.  相似文献   

10.
A new analysis method to detect carbamates and phenylurea pesticide residues in fruit juices was developed using solid-phase microextraction (SPME) coupled with liquid chromatography-single quadrupole mass spectrometry (LC/MS) and liquid chromatography-quadrupole ion trap mass spectrometry (LC/QIT-MS). The pesticide residues present in watery matrices as fruit juices were extracted using three types of fibers: 50-microm Carbowax/templated resin (CW/TPR), 60-mum poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) and 85-microm polyacrylate. The different extraction conditions were evaluated choosing as the best parameters 90 min (time), 20 degrees C (temperature) and 1 ml (volume). After extraction, the desorption (in a static mode) was performed in the specific interface chamber SPME/HPLC, previously filled with 70% methanol and 30% water. The best recoveries, evaluated at two fortification levels (0.2 and 0.5 mg kg(-1)) in fruit juices, were obtained using PDMS/DVB and CW/TPR fibers, and ranged from 25 to 82% (monolinuron, diuron and diethofencarb), with relative standard deviations (RSDs) from 1 to 17%. All the limits of quantification (LOQs) were in the range of 0.005-0.05 microg ml(-1) and, in any case, equal to, or lower than, maximum residue limits (MRLs) established by Italian and Spanish legislations. The mass spectrometry analyses were carried out using an electrospray ionization (ESI) source operating in the positive mode both for single quadrupole and for QIT mass analysers, operating in selected ion monitoring (SIM) and in multiple reaction monitoring (MRM) modes, respectively. The proposed new method can be applied to the determination of selected pesticides in real samples of fruit juices.  相似文献   

11.
A new approach has been developed for the extraction and determination of aldehydes such as veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde by using solid-phase microextraction (SPME) and high-performance liquid chromatography with UV detection (HPLC/UV). The method involves adsorption of the aldehydes on polydimethylsiloxane/divinylbenzene-coated fiber, followed by desorption in the desorption chamber of the SPME-HPLC interface, using acetonitrile-water (70 + 30) as the mobile phase; UV detection was at 254 nm. A good separation of 5 aldehydes was obtained on a C18 column. The detection limits of veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde are 25, 41, 13, 12, and 11 pg/mL, respectively, which are about 100 times better than the detection limits for other SPME methods using gas chromatography. The proposed method was validated by determining benzaldehyde in bitter almonds and cinnamaldehyde in cinnamon bark. The recoveries of the 5 analytes were determined by analysis of spiked drinking water.  相似文献   

12.
A multi-residue method for the determination of tranquiliser residues in animal tissue is described. The procedure may be used to determine residues of the tranquilisers acepromazine, azaperone, chlorpromazine, haloperidol, propionylpromazine, xylazine, the metabolite of azaperone, azaperol, and the beta-adrenoreceptor blocking agent carazolol. Existing methods of analysis for tranquilisers are based on ultraviolet and fluorescence detection and have been used for pig kidney analysis. Determination in this method was by high-performance liquid chromatography with electrochemical detection in the screen mode. The enhanced selectivity offered by the electrochemical detector allowed determination in liver extracts, which often give rise to more interferences on chromatographic traces when using conventional methods of detection. The method offers up to a ten-fold improvement in limits of determination over methods using ultraviolet and fluorescence detection. Recoveries and coefficients of variation have been determined in the range 2-25 micrograms/kg in pig kidney and liver. This electrochemical detection method has been used to measure residues in routine surveillance programmes.  相似文献   

13.
A fully automated high-performance liquid chromatography-gas chromatography (HPLC-GC) network is described. A ten-port valve set up as a loop type LC-GC interface allowed the transfer of large LC effluent fractions into the gas chromatograph by concurrent solvent evaporation. The system performed highly efficient sample enrichment and clean up by LC and on-line GC separation with sensitive electron-capture detection. The efficiency of the system was demonstrated by application to the trace analysis of N-(3-chloro-2,6-dimethylphenyl)-N-(2-oxotetrahydrofuranyl)-2-me thoxyacetamide (CGA 80000) in various crops and soil samples. The residue level determined was 0.02 mg/kg for crop samples and 0.01 mg/kg for soil samples. The relative standard deviations of the calibration graphs were in the range 2-5%; the mean recovery was greater than 85%.  相似文献   

14.
A novel method is developed for separating and enriching pyrethroid pesticides from vegetables by solvent sublation, and determination of the pyrethroids is performed by high-performance liquid chromatography (HPLC). The effects of organic solvent, pH of the solution, nitrogen flow rate, and sublation time on the sublation efficiency of pyrethroids are investigated in detail, and the optimal conditions of the solvent sublation are selected. The floated product of vegetables in the optimal conditions is determined by HPLC. The limit of detection values range from 1.4 microg/kg (for bifenthrin) to 4.2 microg/kg (for fenpropathin). The recoveries of spiked vegetable samples are from 85.7% to 110.4%, and relative standard deviation values are from 1.70% to 6.19%. The results are satisfactory.  相似文献   

15.
A sensitive and efficient solid‐phase microextraction method, based on liquid chromatography and UV–Vis detection, was developed and validated as an alternative method for sample screening prior to LC‐MS analysis. It enables the simultaneous determination of ten pesticides in mango fruits. The fiber used was polydimethylsiloxane while optimum SPME conditions employed have been developed and optimized in a previous work. The desorption process was performed in static mode, using acetonitrile as a solvent. The results indicate that the DI‐SPME/HPLC/UV–Vis procedure resulted in good linear range, accuracy, precision and sensibility and is adequate for analyzing pesticide residues in mango fruits. The limits of detection (0.6–3.3 μg/kg) and quantification (2.0–10.0 μg/kg) were achieved with values lower than the maximum residue levels (MRLs) established by Brazilian legislation for all pesticides in this study. The average recovery rates obtained for each pesticide ranged from 71.6 to 104.3% at three fortification levels, with the relative standard deviation ranging from 4.3 to 18.6%. The proposed method was applied for the determination of the aforementioned compounds in commercial mango samples and residues of azoxystrobin, fenthion, permethrin, abamectin and bifenthrin were detected in the mango samples, although below the MRLs established by Brazilian legislation.  相似文献   

16.
Two simple methods were developed to determine 11 pesticides in coconut water, a natural isotonic drink rich in salts, sugars and vitamins consumed by the people and athletes. The first procedure involves solid-phase extraction using Sep-Pak Vac C18 disposable cartridges with methanol for elution. Isocratic analysis was carried out by means of high-performance liquid chromatography with ultraviolet detection at 254 nm to analyse captan, chlorothalonil, carbendazim, lufenuron and diafenthiuron. The other procedure is based on liquid-liquid extraction with hexane-dichloromethane (1:1, v/v), followed by gas chromatographic analysis with effluent splitting to electron-capture detection for determination of endosulfan, captan, tetradifon and trichlorfon and thermionic specific detection for determination of malathion, parathion-methyl and monocrotophos. The methods were validated with fortified samples at different concentration levels (0.01-12.0 mg/kg). Average recoveries ranged from 75 to 104% with relative standard deviations between 1.4 and 11.5%. Each recovery analysis was repeated at least five times. Limits of detection ranged from 0.002 to 2.0 mg/kg. The analytical procedures were applied to 15 samples and no detectable amounts of the pesticides were found in any samples under the conditions described.  相似文献   

17.
A rapid, sensitive procedure has been developed for determination of N-acetyltransferase activity against octopamine, dopamine and 5-hydroxytryptamine. The assay, which is performed in a volume of 10 microliters, is based upon the separation and detection of monoamine substrates and their N-acetylated derivatives using high-performance liquid chromatography with electrochemical detection. The method has been used to measure N-acetyltransferase activity against octopamine, dopamine and 5-hydroxytryptamine in the cerebral ganglion of the American cockroach, Periplaneta americana and to study bi-substrate kinetics of the enzyme.  相似文献   

18.
Indirect detection is a technically simple method to follow and quantify compounds without inherent detector response in high-performance liquid chromatography. The underlying principle can be expressed in simple equations. These equations indicate clearly how the detection sensitivity can be optimized and how disturbance effects can be avoided when the mobile phase gives detector response.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号