首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, sensitive, and reliable method based on a multi-walled carbon nanotubes (MWNTs) modified carbon ionic liquid electrode (CILE) has been successfully developed for determination of dopamine (DA) in the presence of ascorbic acid (AA). The acid-treated MWNTs with carboxylic acid functional groups could promote the electron-transfer reaction of DA and inhibit the voltammetric response of AA. Due to the good performance of the ionic liquid, the electrochemical response of DA on the MWNTs/CILE was better than that of other MWNTs modified electrodes. Under the optimum conditions a linear calibration plot was obtained in the range 5.0×10(-8) to 2.0×10(-4) mol L(-1) and the detection limit was 1.0×10(-8) mol L(-1).  相似文献   

2.
A chemically modified electrode is constructed based on the multi-walled carbon nanotubes (MWNTs)/4-aminobenzeresulfonic acid (4-ABSA) film-coated glassy carbon electrode. The electrocatalytic oxidation of tyrosine (Tyr) is investigated on the surface of the MWNTs/4-ABSA-modified electrode using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The prepared modified electrode shows voltammetric responses with high sensitivity and selectivity for Tyr in optimal conditions, which makes it very suitable for sub-micromolar detection of Tyr. A sensitive oxidation peak at +0.64 V is employed to determine Tyr. Good linear relationship between the oxidation peak current and the Tyr concentration in the range of 1 × 10−7 to 5 × 10−5 mol/L is obtained in phosphate buffer solution with pH 7.0. By use of modified electrode, the voltammetric detection limit for Tyr in DPV measurements is 8 × 10−8 mol/L (S/N = 3). Good sensitivity, selectivity and stability of the low-cost modified electrode make it very suitable for the determination of trace amounts of Tyr in pharmaceutical and clinical preparations.  相似文献   

3.
Yang P  Wei W  Tao C 《Analytica chimica acta》2007,585(2):331-336
Novel nano-silver coated multi-walled carbon nanotube composites were prepared and used to fabricate a modified electrode. The application of the nano-silver coated multi-walled carbon nanotube composites modified electrode for determination of trace thiocyanate is demonstrated for the first time. The influence of substrate, pH and interference of coexisting substances was investigated for response properties of the electrode. There was a linear relationship at the range 2.5 × 10−9 to 5 × 10−8 mol L−1 and 5 × 10−8 to 1 × 10−6 mol L−1 of thiocyanate with the decrement of anodic DPV peak currents. The limit of detection was 1 × 10−9 mol L−1(S/N = 3). The constructed electrode showed excellent reproducibility and stability. Actual urine and saliva samples of smoker and non-smoker were analyzed and satisfactory results were obtained. This method provides a new way to construct any electrode for biological and environmental analysis.  相似文献   

4.
Salimi A  Hallaj R 《Talanta》2005,66(4):967-975
The performance of preheated glassy carbon electrode modified with carbon nanotubes is described. First glassy carbon electrode is heated for 5 min at 50 °C, then abrasive immobilization of multiwall carbon nanotubes on a preheated glassy carbon electrode was achieved by gentle rubbing of electrode surface on a filter paper supporting carbon nanotubes. Carbon nanotubes (CNTs)-modified glassy carbon electrodes exhibit strong and stable electrocatalytic response toward thiols oxidation in wide pH range. These properties permit an important decrease in over voltage for the oxidation of thiocytosine, glutathione and l-cysteine, as well as a dramatic increase in the peak currents in comparison with bare glassy carbon electrode. Furthermore, the thiols amperometric response of the coated electrodes is extremely stable, with more than 95% of the initial activity after 30 min stirring of 0.1 mM thiols. The electrocatalytic behavior is further exploited as a sensitive detection scheme for thiols detection by hydrodynamic amperometry. The substantial decrease in the overvoltage of the thiols oxidation associated with a stable amperometric response and antifouling properties of nanotubes films allow the development of highly sensitive thiols sensor without using any redox mediator. Such ability of carbon nanotubes to promote the thiols electron transfer reaction, short response time (5 s) and long-term stability, low detection limit, extended linear concentration range, high sensitivity suggest great promise for thiols amperometric sensors and detector for chromatographic analysis of thiol derivatives.  相似文献   

5.
利用电化学方法在多壁碳纳米管修饰的玻碳电极表面聚合一层普鲁士蓝,制备普鲁士蓝/多壁碳纳米管修饰玻碳电极,运用循环伏安法研究了维生素C(vc)在该修饰电极上的电化学行为.该修饰电极对Vc显示出快速的电化学响应和较好的电催化活性,在pH为4.0的磷酸盐溶液中,Ve浓度与其氧化峰电流在8.0×10-4~1.0×10-2 mol/L范围内呈现良好的线性关系,相关系数为0.9993,检测限为6.4×10-5mol/L.该电极具有较好的稳定性和重现性.  相似文献   

6.
We used a carbon paste electrode modified with multi-walled carbon nanotubes as a working electrode and studied the electrochemical behavior of zirconium-alizarin red S complex on it. It was found that the modified electrode exhibited a significant catalytic effect toward the reduction of free alizarin red S and the complex. The second derivative linear scan voltammograms of the complex were recorded by a polarographic analyser from 0 to −1000 mV (vs. SCE), and it was found that the complex can be adsorbed on the surface of the modified electrode, yielding a peak at about −470 mV, corresponding to the reduction of alizarin red S in the complex. The linear range was found to be 2.0 × 10−11–8.0 × 10−7 mol L−1, and the detection limit was 1.0 × 10−11 mol L−1 (S/N = 3) for 3 min accumulation. The procedure was successfully applied to the determination of trace amounts of zirconium in the ore samples. Correspondence: Pei-Hong Deng, Department of Chemistry and Material Science, Hengyang Normal University, Hengyang Hunan 421008, P.R. China  相似文献   

7.
多壁碳纳米管修饰碳黑微电极同时测定多巴胺和抗坏血酸   总被引:1,自引:0,他引:1  
制备了多壁碳纳米管修饰碳黑微电极,研究了多巴胺(DA)和抗坏血酸(AA)在该修饰电极上的电化学行为.实验表明,在pH 7.0的PBS缓冲溶液中,该修饰电极对DA和从均具有显著的催化氧化作用,AA与DA的氧化电位分别为30 mV和280 mV(vs.SCE).利用二次导数线性扫描伏安法测定,DA与AA的线性范围分别为6.0×10-9~2.0×10-4 mol/L和2.0×10-7~1.0×10-3mol/L,检出限为2.0×10-9mol/L 和1.0×10-7mol/L.方法已用于人工合成样品的分析.  相似文献   

8.
Rajesh N. Hegde 《Talanta》2009,79(2):361-368
A simple and rapid electrochemical method was developed for the determination of trace-level trazodone, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs). The MWCNT-modified glassy carbon electrode was constructed and the electrochemical behavior of trazodone was investigated in detail. The cyclic voltammetric results indicate that MWCNT-modified glassy carbon electrode can remarkably enhance electrocatalytic activity towards the oxidation of trazodone in neutral solutions. It leads to a considerable improvement of the anodic peak current for trazodone, and allows the development of a highly sensitive voltammetric sensor for the determination of trazodone. Trazodone could effectively accumulate at this electrode and produce two anodic peaks at about 0.73 V and 1.00 V. The electrocatalytic behavior was further exploited as a sensitive detection scheme for the trazodone determination by differential-pulse voltammetry. Under optimized conditions, the concentration range and detection limit are 0.2-10 μM and 24 nM, respectively for trazodone. The proposed method was successfully applied to trazodone determination in pharmaceutical samples. The analytical performance of this sensor has been evaluated for detection of analyte in urine as a real sample.  相似文献   

9.
Electrochemical behavior of cerium hexacyanoferrate (CeHCF) incorporated on multi-walled carbon nanotubes (MWNTs) modified GC electrode is investigated by scanning electron microscopy (SEM) and electrochemical techniques. The CeHCF/MWNT/GC electrode showed potent electrocatalytic activity toward the electrochemical oxidation of tryptophan in phosphate buffer solution (pH 7.0) with a diminution of the overpotential of 240 mV. The anodic peak currents increased linearly with the concentration of tryptophan in the range of 2.0 × 10−7 to 1.0 × 10−4 M with a detection limit of 2.0 × 10−8 M (at a S/N = 3). And the determination of tryptophan in pharmaceutical samples was satisfactory.  相似文献   

10.
A carbon paste electrode(CPE) chemically modified with multiwall carbon nanotubes and ferrocene(FC) was used as a selective electrochemical sensor for the simultaneous determination of trace amounts of cysteamine(CA) and folic acid(FA).This modified electrode showed very efficient electrocatalytic activity for the anodic oxidation of CA.The peak current of differential pulse voltammograms of CA and FA increased linearly with their concentration in the ranges of 0.7-200μmol/L CA and 5.0- 700μmol/L FA.The detection limits for CA and FA were 0.3μmol/L and 2.0μmoI/L,respectively.The diffusion coefficient(D) and transfer coefficient(α) of CA were also determined.These conditions are sufficient to allow determination of CA and FA both individually and simultaneously.  相似文献   

11.
Huang W  Hu W  Song J 《Talanta》2003,61(3):411-416
A single-wall carbon nanotubes (SWNT)-Nafion film coated glassy carbon electrode (GCE) was described for the determination of 4-aminophenol. In pH 3.0 sodium citrate-HCl buffer, the oxidation peak current of 4-aminophenol increases greatly at the SWNT-Nafion film coated GCE in contrast to that at both bare GCE and Nafion-film coated GCE. Moreover, the oxidation peak potential shifts to more negative potential. All the experimental parameters were optimized for the determination of 4-aminophenol. The oxidation peak current is proportional to the concentration of 4-aminophenol over the range from 5×10−9 to 2×10−6 mol l−1. The detection limit is 8×10−10 mol l−1 at 4 min of accumulation. Using the proposed method, 4-aminophenol in water samples was determined.  相似文献   

12.
Quercetin can effectively accumulate at multi-walled carbon nanotubes-paraffin oil paste electrodes (CNTPE) and cause a sensitive anodic peak at around 0.32 V (vs. SCE) in a 0.10 M phosphate buffer solution (pH = 4.0). Under optimized conditions, the anodic peak current is linear to quercetin concentration in the ranges of 2.0 × 10− 9−1.0 × 10− 7 M and 1.0 × 10− 7−2.0 × 10− 5 M, and the regression equations are ip (μA) = 0.0017 + 0.928c (μM, r = 0.999) and ip (μA) = 0.183 + 0.0731c (μM, r = 0.995), respectively. This paste electrode can be regenerated by repetitively cycling in a blank solution for about 2 min. A 1.0 × 10− 6 M quercetin solution is measured for 10 times using the same electrode regenerated after every determination, and the relative standard deviation of the peak current is 1.7%. The method has been applied to the determination of quercetin in hydrolysate product of rutin and the recovery is 99.2–102.6%. In comparison with graphite paste electrode, carbon nanotubes-nujol paste electrode and carbon nanotubes casting film modified glassy carbon electrode, the CNTPE gives higher ratio of signal to background current and better defined voltammetric peak.  相似文献   

13.
An electrochemical method for the determination of trace levels of mercury based on a multi-walled carbon nanotubes (MWNT) film coated glassy carbon electrode (GCE) is described. In 0.1 mol L–1 HCl solution containing 0.02 mol L–1 KI, Hg2+ was firstly preconcentrated at the MWNT film and then reduced at –0.60 V. During the anodic potential sweep, reduced mercury was oxidized, and then a sensitive and well-defined stripping peak at about –0.20 V appeared. Under identical conditions, a MWNT film coated GCE greatly enhances the stripping peak current of mercury in contrast to a bare GCE. Low concentrations of I remarkably improve the determining sensitivity, since this increases the accumulation efficiency of Hg2+ at the MWNT film coated GCE. The stripping peak current is proportional to the concentration of Hg2+ over the range 8×10–10–5×10–7 mol L–1. The lowest detectable concentration of Hg2+ is 2×10–10 mol L–1 at 5 min accumulation. The relative standard deviation (RSD) at 1×10–8 mol L–1 Hg2+ was about 6% (n=10). By using this proposed method, Hg2+ in some water samples was determined, and the results were compared with those obtained by atomic absorption spectrometry (AAS). The two results are similar, suggesting that the MWNT-film coated GCE has great potential in practical analysis.  相似文献   

14.
A sensitive and accurate method for determining five sulfonamides based on HPLC with amperometric detection and using a glassy carbon electrode modified with multiwalled carbon nanotubes is proposed. Optimal conditions for the quantitative separation of selected sulfonamides were studied, and glassy carbon electrodes with and without modification with carbon nanotubes were systematically investigated as electrodic materials. Statistical analysis of the obtained results demonstrated that these modified electrodes achieved considerably better stability and sensitivity than the conventional unmodified ones. Detection limits were in the 1.2–6.0 ng/mL range. The usefulness of the method was demonstrated by the analysis of milk samples, taking into account the European legislation on residues in food products, following both a screening method to classify the samples and a confirmation method to provide more detailed information in the case of positive samples.  相似文献   

15.
研究了苦参碱(Matrine, MT) 在多壁碳纳米管修饰玻碳电极(MWCNT/GCE)上的电化学行为. 与GCE相比, MT在MWCNT/GCE上峰电位负移120 mV, 峰电流增大约2.5倍, 表明MWCNT/GCE对MT的电化学氧化具有良好的催化作用. 同时测定并计算了MT在MWCNT/GCE上的电极过程动力学参数: 电子转移系数α、电极反应速率常数ks、扩散系数D. 运用差分脉冲伏安法对苦参碱样品含量进行测定, 相对标准偏差为0.12%~2.9%, 加标回收率为98.4%~99.0%. 该方法可用于MT的电化学定量测定.  相似文献   

16.
The paper describes a controllable layer-by-layer (LBL) self-assembly modification technique of multi-walled carbon nanotubes (MWNTs) and poly(diallyldimethylammonium chloride) (PDDA) towards glassy carbon electrode (GCE), Acetylcholinesterase (ACHE) was immobilized directly to the modified GCE by LBL self-assembly method, the activity value of AChE was detected by using i-t technique based on the modified Ellman method. Then the composition of carbaryl were detected by the enzyme electrode with 0.01U activity value and the detection limit of carbaryl is 10^- 12 g L ^-1 so the enzyme biosensor showed good properties for pesticides residue detection.  相似文献   

17.
研究了苯甲酰肼(BH)在MWCNT/GCE上的电化学行为。实验结果表明,BH在GCE上的直接电化学氧化十分迟缓,无氧化峰出现,但在MWCNT/GCE上BH在0.20 V处出现了一个不可逆氧化峰,且峰电流大幅度增大,表明MWCNT/GCE对BH电化学氧化具有良好的催化作用。同时用计时库仑法(Chro-nocoulometry,CC)和计时电流法(Chronoamperometry,CA)测定了电极过程动力学参数:扩散系数D=8.73×10-5cm2.s-1,电子转移系数α=0.85,电极反应速率常数kf=1.45×10-3s-1。稳态电流-时间实验结果表明,电流响应信号随其浓度成比例增长,响应时间小于6 s,最低响应浓度为1×10-6mol/L。该方法可用于BH电化学定量测定。  相似文献   

18.
《Comptes Rendus Chimie》2016,19(3):371-380
Manganese porphyrin has been supported onto multi-walled carbon nanotubes (Mn(TCPP)OAc@MWCNT) and characterized by powder X-ray diffraction, FT-IR, atomic absorption and UV–vis spectroscopy, field emission scanning electron microscopy (FE-SEM) and also thermogravimetric analysis (TGA). The TGA curve shows that the nanocatalyst was thermally stable up to almost 350 °C. This catalyst was found to be able to oxidize different synthetic textile dyes in aqueous media over a wide pH range at ambient temperature with tert-butyl hydroperoxide (TBHP) as the oxygen source. The influence of some important parameters such as the initial pH of the dye solution, temperature and concentration of the catalyst, the oxidant and the co-catalyst were investigated. Also, the ability of this heterogeneous catalyst to oxidize 2,6-dimethylphenol (with excellent selectivity for quinone (86%)) with TBHP in acetonitrile was evaluated. The separation and recycling of the catalyst is simple and the catalyst can be used several successive cycles without significant decrease in catalytic activity.  相似文献   

19.
Polyaniline (PANI) nanotubes were prepared by the oxidation of aniline in solutions of acetic or succinic acid, and subsequently carbonized in a nitrogen atmosphere during thermogravimetric analysis running up to 830 °C. The nanotubular morphology of PANI was preserved after carbonization. The molecular structure of the original PANI and of the carbonized products has been analyzed by FTIR and Raman spectroscopies. Carbonized PANI nanotubes contained about 8 wt.% of nitrogen. The molecular structure, thermal stability, and morphology of carbonized PANI nanotubes were compared with the properties of commercial multi-walled carbon nanotubes.  相似文献   

20.
Lu S  Wu K  Dang X  Hu S 《Talanta》2004,63(3):653-657
Simple and sensitive electrochemical method for the determination of metronidazole, based on a nanostructured film coated glassy carbon electrode (GCE), is described. Multi-walled carbon nanotubes (MWNT) was dispersed into water in the presence of a hydrophobic surfactant to give very stable and homogeneous MWNT suspension, and a MWNT-film coated GCE was achieved via evaporating solvent. Metronidazole yields a well-defined reduction peak whose potential is −0.71 V at the MWNT-film coated GCE in pH 9.0 Britton-Robinson buffer. Compared with bare GCE, the MWNT-film modified GCE significantly enhances the reduction peak current of metronidazole. All the experimental parameters were optimized for the determination of metronidazole. The detection limit is 6×10−9 mol/l at 2 min accumulation. This method has been successfully used to determine metronidazole in the drugs. Furthermore, results obtained by the proposed method have been compared with spectrophotometric method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号