共查询到20条相似文献,搜索用时 0 毫秒
1.
Enhanced extraction capacity and chemical noise reduction in solid-phase microextraction 总被引:1,自引:0,他引:1
Solid-phase microextraction fibres with different lengths, coatings (polydimethylsiloxane, polyacrylate, Carbowax/divinylbenzene), film thicknesses, and mounting techniques were examined in combination with GC-MS with regard to their enhanced extraction capacities and fibre 'bleeding'. A series of phenols and halogenated aromatics with diverse physicochemical properties were investigated to characterize the effects of the enhanced extraction capacities of solid-phase microextraction fibres. Fibre extension was found to be effective for the microextraction of compounds with high log Kow values, whereas increasing both coating thickness and fibre length is most effective for the microextraction of more polar compounds such as phenols. Almost no bisphenol A was released when custom-made polydimethylsiloxane fibres were used, finally eliminating a drawback of endocrine disrupter analysis by solid-phase microextraction. 相似文献
2.
3.
Russian Chemical Bulletin - 相似文献
4.
The possibility of identifying industry-related traces of oil contamination in biogenic sediments is investigated on an example of model oil-contaminated peat samples. It is shown that oil pollution of <1 wt % in biogenic samples cannot be identified using a conventional IR spectrometric procedure. An additional study of organic extracts, isolated in sample preparation, by solid-phase extraction and thin layer chromatography can detect specific oil aromatic hydrocarbons in contaminated samples uncharacteristic for background samples of the same type. 相似文献
5.
Carabias-Martínez R García-Hermida C Rodríguez-Gonzalo E Ruano-Miguel L 《Journal of separation science》2005,28(16):2130-2138
This work reports a study of the chromatographic behaviour of seven carbamate pesticides (aldicarb, carbetamide, propoxur, carbofuran, carbaryl, methiocarb, and pirimicarb) by gas chromatography-mass spectrometry (GC-MS). Variables such as injector temperature, solvent, injection mode, and the degree of ageing of the chromatographic column were studied. One of the aims of this work was to achieve a controlled decomposition of carbamates by a solid-phase microextraction (SPME) preconcentration step with a polyacrylate fibre in order to obtain reproducible chromatographic signals of the degradation products. Optimisation of the SPME process was accomplished by means of experimental design. Several methods using ultrapure water were developed with different preconcentration configurations: SPME-GC-MS, SPE followed by SPME-GC-MS, and SPE plus GC-MS. For all the pesticides studied, method detection limit (MDL) values below 0.1 microg L-1 were reached in at least one of the proposed configurations. 相似文献
6.
This paper deals with comparison of efficiency of extraction techniques (solid-phase extraction, SPE and solid-phase microextraction, SPME) used for extraction of nitrate esters (ethyleneglycoldinitrate, EGDN and nitroglycerin, NG), representing the first step of the method of quantitative determination of trace concentrations of nitrate esters in water samples. EGDN and NG are subsequently determined by means of high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Optimization of SPE and SPME conditions was carried out using model water samples. Seven SPE cartridges were tested and the conditions were optimized (type of sorbent, type and volume of solvent to be used as eluent). For both nitrate esters the limit of detection (LOD) and the limit of quantification (LOQ) obtained using SPE/HPLC-UV were 0.23 microg mL(-1) and 0.70 microg mL(-1), respectively. Optimization of SPME conditions: type of SPME fibre (four fibres were tested), type and time of sorption/desorption, temperature of sorption. PDMS/DVB (polydimethylsiloxane/divinylbenzene) fibre coating proved to be suitable for extraction of EGDN and NG. For this fibre the LOD and the LOQ for both nitrate esters were 0.16 microg mL(-1) and 0.50 microg mL(-1), respectively. Optimized methods SPE/HPLC-UV and SPME/HPLC-UV were then used for quantitative determination of nitrate esters content in real water samples from the production of EGDN and NG. 相似文献
7.
López-Blanco MC Blanco-Cid S Cancho-Grande B Simal-Gándara J 《Journal of chromatography. A》2003,984(2):245-252
Water contamination due to the wide variety of pesticides used in agriculture practices is a global environmental pollution problem. The 98/83 European Directive requires the measurement of pesticides residues at a target concentration of 1.0 microg/l in surface water and 0.1 microg/l in drinking water. In order to reach the level of detection required, efficient extraction techniques are necessary. The application of a new extraction technique: single-drop microextraction (SDME), followed by gas chromatography with electron-capture detection, was assessed for determining alpha-endosulfan and beta-endosulfan in water samples. Experimental parameters which control the performance of SDME, such as selection of microextraction solvent and internal standard, optimization of organic drop volume, effects of sample stirring, temperature and salt addition, and sorption time profiles were studied. Once SDME was optimized, analytical parameters such as linearity, precision, detection and quantitation limits, plus matrix effects were evaluated. The SDME method was compared with solid-phase microextraction and solid-phase extraction with the aim of selecting the most appropriate method for a certain application. 相似文献
8.
Molecularly imprinted polymers (MIPs) are synthetic polymers having a predetermined selectivity for a given analyte, or group of structurally related compounds, that make them ideal materials to be used in separation processes. In this sense, during past years a huge amount of papers have been published dealing with the use of MIPs as sorbents in solid-phase extraction, namely molecularly imprinted solid-phase extraction (MISPE). Although the majority of these papers were restricted to describe the use of different templates for different applications, several attempts proposing new alternatives to minimize the inherent drawbacks of the preparation and use of MIPs (i.e. template bleeding, tedious synthesis procedure, etc.) have been reported. Thus, this paper does not pretend to be a collection of MISPE-related papers but to give an overview on the significant attempts carried out during recent years to improve the performance of MIPs in solid-phase extraction. In addition, the use of MIPs packed in high performance liquid chromatography (HPLC) columns for the direct injection of crude sample extracts and the preparation of imprinted fibres for solid-phase microextraction will be also discussed. 相似文献
9.
Shirey RE 《Journal of chromatographic science》2000,38(3):109-116
A group of volatile analytes under a molecular weight of 90 and representing 11 organic classes are extracted using identical conditions with 6 different solid-phase microextraction fiber coatings. The amount of each of the analytes extracted by the various fibers is shown. The effects of sample modifiers, such as pH and ionic strength, on the recovery of the analytes are presented. A comparison of headspace and immersion extraction techniques is shown. 相似文献
10.
A sol-gel method for the preparation of solid-phase microextraction (SPME) fiber was described and evaluated. The extraction phase of poly(dimethysiloxane) (PDMS) containing 3% vinyl group was physically incorporated into the sol-gel network without chemical bonding. The extraction phase itself is then partly crosslinked at 320 degrees C, forming an independent polymer network and can withstand desorption temperature of 290 degrees C. The headspace extraction of BTX by the fiber SPME was evaluated and the detection limit of o-xylene was down to 0.26 ng/l. Extraction and determination of organophosphorus pesticides (OPPs) in water, orange juice and red wine by the SPME-GC thermionic specified detector (TSD) was validated. Limits of detection of the method for OPPs were below 10 ng/l except methidathion. Relative standard deviations (RSDs) were in the range of 1-20% for pesticides being tested. 相似文献
11.
In this study a direct solid-phase microextraction (SPME) procedure has been developed for the determination of carbofuran in water. Experimental parameters such as selection of SPME coating, effect of temperature, effect of salt addition and solvent desorption were studied and optimized. Analytical parameters such as linearity, precision, detection and quantitation limits, and matrix effects for solid-phase extraction (SPE) and SPME methods were evaluated for comparison purposes with the aim of selecting the most appropriate depending on the detection capabilities required. SPE and SPME were followed by high-performance liquid chromatography with diode-array detection, using a 50 x 4.6 mm I.D. guard column and a 150 x 4.6 mm I.D. analytical column, both packed with C18 silica. Both methods can be applied to real samples and give the same results, but SPE allows the detection of lower carbofuran concentrations (0.06 microg/L) as compared to 相似文献
12.
The decrement of equilibrium extraction time without losing extraction efficiency in solid-phase microextraction (SPME) was achieved using nano-structured coating. Polyaniline (PANI) was used as an extraction phase for the comparison of extraction capacity and equilibrium extraction time of nano- and micro-structured coatings. Polychlorinated biphenyls (PCBs) were used as model compounds to examine the extraction properties of nano- and micro-structured coatings. The results revealed that nano-structured PANI coating showed higher extraction rate and shorter desorption time than micro-structured coating, because of the larger surface area. In order to evaluate the extraction capability of prepared nano-structured PANI coating, headspace-SPME method was used for the determination of PCBs in sediment samples by GC-electron capture detector. The proposed method was validated using the certified reference material. 相似文献
13.
Determination of the fungicides vinclozolin and dicloran in soils using ultrasonic extraction coupled with solid-phase microextraction 总被引:1,自引:0,他引:1
Solid-phase microextraction (SPME) coupled to ultrasonic extraction was evaluated for extracting trace amounts of two agrochemical fungicides, vinclozolin and dicloran, in soil samples. Extraction was performed following two experimental approaches prior to the submission of the aqueous extracts to SPME-GC analysis. In the first approach, extraction involved sample homogenization with a water solution containing 5% (v/v) acetone and centrifugation prior to fiber extraction. In the second approach, the extraction of the fungicides from the soil samples was conducted using acetone as organic solvent which was then diluted with water to give a 5% (v/v) content. The pesticides were isolated with fused silica fiber coating with 85 μm polyacrylate. Parameters that affect both the extraction of the fungicides by the soil samples and the trapping of the analytes by the fiber were investigated and their impact on the SPME-GC-MS was studied. The procedures with respect to repeatability and limits of detection were evaluated by soil spiked with both analytes. Repeatability was between 5.6 and 14.2% and the limits of detection were 2-13 ng g−1. The efficiency of acetone/SPME was generally better than that for water/SPME procedure showing good linearity (R2>0.99) with coefficient variations below 9%, recoveries higher than 91% and limits of detection between 2 and 3 ng g−1. Finally, the recoveries obtained with acetone/SPME procedure were compared with the conventional liquid-liquid extraction using real soil samples. The acetone/SPME method was shown to be an inexpensive, fast and simple preparation method for the determination of target analytes at low nanogram per gram levels in soils. 相似文献
14.
The extraction performance of solid-phase microextraction fibers, based on methacrylic acid-trimethylolpropanetrimethacrylate (MAA/TRIM) copolymers, was investigated in aqueous solutions using triazines as target analytes and 2-bromobiphenyl as a reference compound. The results revealed that the combination of electrostatic forces and hydrophobicity was the primary interaction between the MAA/TRIM coating and the triazines. To improve the selectivity of the MAA/TRIM-coated fiber for the triazines, several experimental parameters including pH of the sample solution, washing step, organic modifier, and salt concentration were optimized so as to amplify electrostatic interaction and suppress the hydrophobic effect. To evaluate the practicability of the proposed method, samples with complex matrixes, including corn extract and sewage sludge, were extracted with a MAA/TRIM-coated fiber under the optimized conditions chosen. The results showed that the extraction efficiency for target analytes was not enhanced, but the matrix effect of the interfering compounds in the samples was effectively restrained and thus the selectivity was obviously improved. 相似文献
15.
《Analytica chimica acta》2004,506(1):71-80
We describe an estimation of measurement uncertainty calculated by the “bottom-up” approach for the determination of the oestrogenic compound nonylphenol in treated water samples by solid-phase extraction (SPE) and solid-phase microextraction (SPME) procedures and GC/MS detection. The results were compared and the different contributions to the uncertainty were evaluated. A study of the linear range was established and validation was performed for both methods using statistical analysis of several indicative parameters. In terms of validation data, precision (R.S.D. values <20%) and trueness (relative error <11%) were obtained for both methods under day-to-day conditions. The results of the estimation of measurement uncertainty obtained for both methods for concentrations higher than 1 μg/l have demonstrated that the time-consuming SPE method has a lower relative uncertainty (32%) than the SPME method (42.8%). The chromatographic uncertainty value was the main factor in the SPME method whereas the recovery factor (used to calculate the concentration) was the main contribution to uncertainty in the SPE method. 相似文献
16.
B K Lavine D M Brzozowski J Ritter A J Moores H T Mayfield 《Journal of chromatographic science》2001,39(12):501-507
The water-soluble fraction of aviation jet fuels is examined using solid-phase extraction and solid-phase microextraction. Gas chromatographic profiles of solid-phase extracts and solid-phase microextracts of the water-soluble fraction of kerosene- and nonkerosene-based jet fuels reveal that each jet fuel possesses a unique profile. Pattern recognition analysis reveals fingerprint patterns within the data characteristic of fuel type. By using a novel genetic algorithm (GA) that emulates human pattern recognition through machine learning, it is possible to identify features characteristic of the chromatographic profile of each fuel class. The pattern recognition GA identifies a set of features that optimize the separation of the fuel classes in a plot of the two largest principal components of the data. Because principal components maximize variance, the bulk of the information encoded by the selected features is primarily about the differences between the fuel classes. 相似文献
17.
Tri-, tetra- and pentachlorophenol (TCP, TeCP and PCP) can be considered the precursors in the formation of corresponding chloroanisoles, known to be powerful odorants in corks and wine. Determining the presence of these chlorophenolic compounds in cork soaking solutions (ethanol/water mixtures, 12% (v/v) ethanol used for cork quality control testing), or in wine can be achieved by acetylation/gas chromatography electron-capture detection. In order to reach the required sensitivity, a previous preconcentration step is necessary. Solid-phase extraction (SPE) and headspace solid-phase microextraction (HS-SPME) have given good results for the preconcentration of TCP, TeCP and PCP in such matrices. The use of Oasis HLB cartridges gives acceptable recoveries for the three compounds when different volumes (50-250 mL) of cork macerate with concentrations ranging from 20 to 150 ng/L are processed. Preconcentration based on HS-SPME has also been optimised with a 100 microm polydimethylsiloxane fibre and in situ derivatization. The HS-SPME method allows chlorophenols in a cork soaking solution and in wine to be determined with a limit of detection of 1 ng/L for each compound (in cork macerate) and a repeatability of around 0.5%-5% (n=8) for a concentration level of 30 ng/L. 相似文献
18.
A headspace analysis for groundwater contaminated with BTEX (benzene, toluene, ethylbenzene, and xylenes) was employed to investigate the feasibility and limitations of Carboxen-PDMS (polydimethylsiloxane) fiber during SPME (solid-phase microextraction). Although the response of the Carboxen-PDMS fiber was much higher than that of conventional PDMS fiber, a reduction of the extracted amount was also observed under multi-component conditions due to competitive replacement. The general affinity of analytes to the fiber was high in the order xylene>ethylbenzene>toluene> benzene. The behavior of the Carboxen-PDMS fiber was examined more precisely at constant compositional ratio, because the analysis of contaminants using Carboxen-PDMS fiber was reported to be possible at known composition. The relative affinity of each component was shown to differ according to the total amount of analytes. Furthermore, the extracted amounts of benzene and toluene did not show a consistent tendency as the concentration of each component increased. These results indicate that caution should be exercised if Carboxen-PDMS fibers are used for the analysis of BTEX in groundwater samples. 相似文献
19.
The separation of three selective serotonin reuptake inhibitors (SSRIs) by capillary electrophoresis (CE) with fully integrated solid-phase extraction (SPE) is described. Polymeric monolithic SPE modules were prepared in situ within a fused silica capillary from either butyl methacrylate-co-ethylene dimethacrylate or 3-sulfopropyl methacrylate-co-butyl methacrylate-co-ethylene dimethacrylate. Using a 1 cm SPE module placed at the inlet of the capillary, a mixture of sertraline, fluoxetine and fluvoxamine was extracted from aqueous solution by applying a simple pressure rinse. Under pressure-driven conditions, efficient elution was possible from both SPE materials investigated using 50 mM phosphate buffer, pH 3.5 in acetonitrile (20/80, v/v). Two different strategies were investigated for the efficient elution and subsequent CE separation. Injection of an aqueous sample plug directly into the non-aqueous elution/separation buffer was found to be unsuitable with poor elution profiles observed in the electrodriven mode. Alternatively, a sample plug equivalent to several capillary volumes could be injected by pressure followed by filling the capillary with the non-aqueous elution/separation buffer from the outlet end using a combination of pressure and electrodriven flow. Using a neutral monolith, efficient elution/separation was not possible due to an unstable electroosmotic flow (EOF), however, by adding the ionisable monomer, 3-sulfopropyl methacrylate to the SPE module to increase and stabilise the EOF, it was possible to achieve efficient elution from the SPE module, followed by baseline separation by CE using a 200 mM acetate buffer, pH 3.5 in acetonitrile (10/90, v/v). With enrichment factors of over 500 achieved for each of the analytes this demonstrates the potential of in-line SPE-CE for the sensitive analysis of these drugs. 相似文献
20.
Evaluation of graphene as an advantageous adsorbent for solid-phase extraction with chlorophenols as model analytes 总被引:1,自引:0,他引:1
Graphene, a novel class of carbon nanostructures, possesses an ultrahigh specific surface area, and thus has great potentials for the use as sorbent materials. We herein demonstrate the use of graphene as a novel adsorbent for solid-phase extraction (SPE). Eight chlorophenols (CPs) as model analytes were extracted on a graphene-packed SPE cartridge, and then eluted with alkaline methanol. The concentrations in the eluate were determined by HPLC with multi-wavelength UV detection. Under the optimized conditions, high sensitivity (detection limits 0.1-0.4 ng/mL) and good reproducibility of CPs (RSDs 2.2-7.7% for run-to-run assays) were achieved. Comparative studies showed that graphene was superior to other adsorbents including C18 silica, graphitic carbon, single- and multi-walled carbon nanotubes for the extraction of CPs. Some other advantages of graphene as SPE adsorbent, such as good compatibility with various organic solvents, good reusability and no impact of sorbent drying, have also been demonstrated. The proposed method was successfully applied to the analysis of tap and river water samples with recoveries ranging from 77.2 to 116.6%. This work not only proposes a useful method for environmental water sample pretreatment, but also reveals great potentials of graphene as an excellent sorbent material in analytical processes. 相似文献