首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Objective

The objective was to determine imaging features that distinguish small (≤3cm) solid pancreatic adenocarcinoma, neuroendocrine tumor (NET) and solid pseudopapillary tumor (SPT) on gadoxetic-acid-enhanced magnetic resonance imaging (MRI) and diffusion-weighed imaging (DWI).

Materials and methods

Twenty-four adenocarcinomas, 10 NETs and 8 SPTs were retrospectively included. Two radiologists analyzed morphologic features, signal intensity of the tumors on MR images including DWI (b=800) and dynamic enhancement pattern with consensus. Tumor-to-parenchyma ratio and tumor apparent diffusion coefficients (ADCs) were quantitatively assessed.

Results

All adenocarcinomas had an ill-defined margin and irregular shape, and more frequently had pancreatic duct dilatation compared with other tumors (P<.05). All SPTs and all but one of the adenocarcinomas (95.8%) had no arterial enhancement with progressively increased enhancement, whereas seven NETs (70%) had arterial enhancement with progressively decreased enhancement (P<.01). The mean value of tumor-to-parenchyma ratio on arterial and portal phases was significantly higher for NETs, and the mean value of tumor ADCs was significantly lower for SPTs than for other tumors (P<.05).

Conclusions

Gadoxetic-acid-enhanced MRI may aid in differentiation between small adenocarcinomas, NETs and SPTs based on morphologic features with dynamic enhancement pattern in adenocarcinomas, dynamic enhancement pattern with tumor-to-parenchyma ration on arterial and portal phases in NETs, and dynamic enhancement pattern with lower ADC value in SPTs.  相似文献   

2.

Purpose

The purposes of this study were to describe dynamic gadolinium-enhanced magnetic resonance imaging (MRI) findings of intrapancreatic accessory spleen(s) (IPAS) in five patients and to show how superparamagnetic iron oxide (SPIO) enhancement can be used for definite characterization in two cases.

Materials and Methods

An MRI database was searched for patients who had pancreatic tail lesions with imaging features compatible with IPAS between June 2005 and July 2007. Five (four male, one female) patients (age: mean±S.D., 58±9.8 years; range, 50–75 years) were identified. All patients were examined with standard gadolinium-enhanced MRI protocol. Additionally, two patients were examined with SPIO-enhanced MRI protocol. All MRI examinations were retrospectively and blindly evaluated by two radiologists for the predetermined findings, and their final diagnoses were noted.

Results

One pancreatic tail lesion was detected in each patient. All of these lesions were single, focal, well-marginated and located within 3 cm of the distal tail of the pancreas. The mean size (mean±S.D.) of the lesions was (2.02±0.64)×(1.72±0.42) cm2, and all lesions had a rounded morphology. The signal intensity of all lesions was similar to that of the spleen on all sequences, including precontrast, postgadolinium and post-SPIO sequences. The reviewers confidently diagnosed IPAS in two patients who had SPIO-enhanced MRI. In the remaining three patients, the reviewers favored the diagnosis of IPAS based on the findings of standard gadolinium-enhanced MRI; however, they could not definitively exclude the other differential diagnoses.

Conclusion

The discovery of a well-marginated, rounded mass in the distal aspect of the tail of the pancreas with signal intensity features of the spleen on all precontrast and postgadolinium sequences suggests the diagnosis of IPAS. However, SPIO-enhanced MRI can be used to characterize the lesion and to establish the definite diagnosis of IPAS in case of clinical doubt.  相似文献   

3.

Purpose

To evaluate whether semi-quantitative analysis of high temporal resolution dynamic contrast-enhanced MRI (DCE-MRI) acquired early in treatment can predict the response of locally advanced breast cancer (LABC) to neoadjuvant chemotherapy (NAC).

Materials and Methods

As part of an IRB-approved prospective study, 21 patients with LABC provided informed consent and underwent high temporal resolution 3 T DCE-MRI before and after 1 cycle of NAC. Using measurements performed by two radiologists, the following parameters were extracted for lesions at both examinations: lesion size (short and long axes, in both early and late phases of enhancement), radiologist's subjective assessment of lesion enhancement, and percentages of voxels within the lesion demonstrating progressive, plateau, or washout kinetics. The latter data were calculated using two filters, one selecting for voxels enhancing ≥ 50% over baseline and one for voxels enhancing ≥ 100% over baseline. Pretreatment imaging parameters and parameter changes following cycle 1 of NAC were evaluated for their ability to discriminate patients with an eventual pathological complete response (pCR).

Results

All 21 patients completed NAC followed by surgery, with 9 patients achieving a pCR. No pretreatment imaging parameters were predictive of pCR. However, change after cycle 1 of NAC in percentage of voxels demonstrating washout kinetics with a 100% enhancement filter discriminated patients with an eventual pCR with an area under the receiver operating characteristic curve (AUC) of 0.77. Changes in other parameters, including lesion size, did not predict pCR.

Conclusion

Semi-quantitative analysis of high temporal resolution DCE-MRI in patients with LABC can discriminate patients with an eventual pCR after one cycle of NAC.  相似文献   

4.

Purpose

To evaluate the diagnostic performance of an apparent diffusion coefficient (ADC) and quantitative kinetic parameters in patients with newly diagnosed breast cancer.

Materials and Methods

We enrolled 169 lesions in 89 patients with breast cancer who underwent dynamic contrast-enhanced MRI (DCE-MRI) and diffusion-weighted imaging (DWI). Comparisons between benign and malignant lesions were performed for lesion type (mass or nonmass-like enhancement), size (≥ 1 cm or < 1 cm), ADC, kinetic parameters and the presence of a US correlate.

Results

There were 63 benign and 106 malignant lesions. The mean size and initial peak enhancement of the benign lesions were significantly lower than those of malignant lesions (P < 0.001 for both). The ADC of the benign lesions was significantly higher than that of malignant lesions (1.42 × 10− 3 mm2/sec vs. 1.04 × 10− 3 mm2/sec; P < 0.001). The area under the receiver operating characteristic curve (AUC) for predicting malignancy was 0.87 for the combined parameters of size, ADC, and initial peak enhancement, which was higher than those of each parameter.

Conclusions

Combination of quantitative kinetic parameters and ADC showed higher diagnostic performance for predicting malignancy than each parameter alone for the evaluation of patients with breast cancer.  相似文献   

5.

Purpose

To investigate progression of cryoinjury in pigs using contrast-enhanced magnetic resonance imaging (MRI) as well as optical spectroscopy and imaging.

Methods

Cryoinjury was produced in 16 pigs in vivo and investigated using Gd-and Mn-enhanced MRI, optical imaging/spectroscopy and histology in acute and chronic setting up to 4 weeks after the injury.

Results

(1) Acute cryoinjury resulted in formation of a lesion with a severely reduced rate of sub-epicardial indocyanine green (intravascular optical flow tracer) passage. In vivo late Gd-enhanced MRI showed a ∼10 mm deep hypointense area that was surrounded by a hyperintense rim while ex vivo Mn-enhanced MRI (MEMRI) detected a homogenous hypointense zone. Histological and spectroscopic examination revealed embolic erythrocytes blockages within the cryolesion with a thin necrotic rim neighboring the normal myocardium. (2) Chronic 4-week cryoinjury was characterized by uniform Gd-enhancement, whereas MEMRI revealed reduced Mn2+enhancement. Histological examination showed replacement of the cryoinjured myocardium by scar tissue.

Conclusions

Acute cryoinjury resulted in formation of a no-reflow core embolized by erythrocytes and surrounded by a rim of necrotic tissue. Upon injury progression, the no-reflow zone shrunk and was completely replaced with scar tissue by 4 weeks after injury.  相似文献   

6.

Background

Acute symptomatic inflammation is a main feature of multiple sclerosis but pathophysiological processes underlying total or partial recovery are poorly understood.

Objective

To characterize in vivo these processes at molecular, structural and functional levels using multimodal MR methods.

Methods

A neuroimaging 3-year follow-up (Weeks 0, 3, 11, 29, 59 and 169) was conducted on a 41-year-old woman presenting at baseline with a large acute demyelinating lesion of multiple sclerosis. Conventional magnetic resonance imaging (MRI), magnetization transfer imaging, diffusion-weighted imaging, functional MRI and magnetic resonance spectroscopy were conducted at 1.5 T.

Results

Patient presenting with subacute left hemiplegia recovered progressively (expended disability status scale 7 to 5.5). The MR exploration demonstrated structural functional and metabolic impairments at baseline. Despite restoration of the blood brain barrier integrity, high lactate levels persisted for several weeks concomitant with glial activation. Slow and progressive structural and metabolic restorations occurred from baseline to W169 (lesion volume −64%; apparent diffusion coefficient −14.7%, magnetization transfer ratio +14%, choline −51%, lipids −78%, N-acetylaspartate +77%) while functionality of the motor system recovered.

Conclusions

Multimodal MRI/MRS evidenced long-term dynamics recovery processes involving tissue repair, glial activation, recovery of neuronal function and functional systems. This may impact on customized rehabilitation strategies generally focused on the first months following the onset of symptoms.  相似文献   

7.

Objectives

Diffusion imaging represents a new imaging tool for the diagnosis of breast cancer. This study aims to investigate the role of diffusion-weighted MRI with background body signal suppression (DWIBS) for evaluating breast lesions.

Methods

90 patients were prospectively evaluated by MRI with STIR, TSE-T2, contrast enhanced THRIVE-T1 and DWIBS sequences. DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤ 1.44 × 10- 3 mm2/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated.

Results

In 53/90 (59%) patients, DWIBS indicated the presence of breast lesions, 16 (30%) with ADC values of  > 1.44 and 37 (70%) with ADC ≤ 1.44. The comparison with histology showed 25 malignant and 28 benign lesions. DWIBS sequences obtained sensitivity, specificity, DA, PPV and NPV values of 100, 82, 87, 68 and 100%, respectively.

Conclusion

DWIBS can be proposed in the MRI breast protocol representing an accurate diagnostic complement.  相似文献   

8.

Purpose

To verify whether in patients with partial epilepsy and routine electroenecephalogram (EEG) showing focal interictal slow-wave discharges without spikes combined EEG–functional magnetic resonance imaging (fMRI) would localize the corresponding epileptogenic focus, thus providing reliable information on the epileptic source.

Methods

Eight patients with partial epileptic seizures whose routine scalp EEG recordings on presentation showed focal interictal slow-wave activity underwent EEG–fMRI. EEG data were continuously recorded for 24 min (four concatenated sessions) from 18 scalp electrodes, while fMRI scans were simultaneously acquired with a 1.5-Tesla magnetic resonance imaging (MRI) scanner. After recording sessions and MRI artefact removal, EEG data were analyzed offline. We compared blood oxygen level-dependent (BOLD) signal changes on fMRI with EEG recordings obtained at rest and during activation (with and without focal interictal slow-wave discharges).

Results

In all patients, when the EEG tracing showed the onset of focal slow-wave discharges on a few lateralized electrodes, BOLD-fMRI activation in the corresponding brain area significantly increased. We detected significant concordance between focal EEG interictal slow-wave discharges and focal BOLD activation on fMRI. In patients with lesional epilepsy, the epileptogenic area corresponded to the sites of increased focal BOLD signal.

Conclusions

Even in patients with partial epilepsy whose standard EEGs show focal interictal slow-wave discharges without spikes, EEG–fMRI can visualize related focal BOLD activation thus providing useful information for pre-surgical planning.  相似文献   

9.

Purpose

The purpose of the study was to determine significant imaging features to differentiate between infiltrative hepatocellular carcinoma (HCC) and confluent fibrosis (CF) in liver cirrhosis using Gd-EOB-DTPA-enhanced 3-T magnetic resonance imaging.

Material and methods

Nineteen infiltrative HCCs and eight CFs were included. We evaluated the difference in imaging findings and apparent diffusion coefficient (ADC) between the two entities. We compared T2-weighted image (WI) and hepatobiliary phase (HBP) in terms of the clarity of the lesion outer margin.

Results

Seventeen infiltrative HCCs showed lobulated margin, while focal CFs showed either straight (n = 3) or irregular margins (n = 5) (P = .001). All infiltrative HCCs had intact or bulging contours, and all focal CFs showed capsular retraction (P = .001). Fourteen infiltrative HCCs and two focal CFs showed arterial enhancement (P = .035). The ADC of infiltrative HCCs was significantly lower than that of CFs (P = .001). Satellite nodules were noted in 10 infiltrative HCCs. In terms of outer margin clarity, infiltrative HCCs showed a more distinct margin on HBP than on T2-WI (P = .005), while these two sequences were not significantly different in focal CFs (P = 1.000).

Conclusion

HBP improved the imaging characteristics of infiltrative HCC, allowing it to be distinguished from focal CF. Infiltrative HCC showed lower ADC values than focal CF. Lobular configuration, contour bulging, enhancement pattern, associated satellite nodules and portal vein thrombosis were still found to be highly suggestive MR findings for infiltrative HCC.  相似文献   

10.

Purpose

To develop an approach for computer-aided detection (CAD) of small brain metastases in post-Gd T1-weighted magnetic resonance imaging (MRI).

Method

A set of unevenly spaced 3D spherical shell templates was optimized to localize brain metastatic lesions by cross-correlation analysis with MRI. Theoretical and simulation analyses of effects of lesion size and shape heterogeneity were performed to optimize the number and size of the templates and the cross-correlation thresholds. Also, effects of image factors of noise and intensity variation on the performance of the CAD system were investigated. A nodule enhancement strategy to improve sensitivity of the system and a set of criteria based upon the size, shape and brightness of lesions were used to reduce false positives. An optimal set of parameters from the FROC curves was selected from a training dataset, and then the system was evaluated on a testing dataset including 186 lesions from 2753 MRI slices. Reading results from two radiologists are also included.

Results

Overall, a 93.5% sensitivity with 0.024 of intra-cranial false positive rate (IC-FPR) was achieved in the testing dataset. Our investigation indicated that nodule enhancement was very effective in improving both sensitivity and specificity. The size and shape criteria reduced the IC-FPR from 0.075 to 0.021, and the brightness criterion decreases the extra-cranial FPR from 0.477 to 0.083 in the training dataset. Readings from the two radiologists had sensitivities of 60% and 67% in the training dataset and 70% and 80% in the testing dataset for the metastatic lesions <5 mm in diameter.

Conclusion

Our proposed CAD system has high sensitivity and fairly low FPR for detection of the small brain metastatic lesions in MRI compared to the previous work and readings of neuroradiologists. The potential of this method for assisting clinical decision- making warrants further evaluation and improvements.  相似文献   

11.

Purpose

The purpose of this study was to describe magnetic resonance (MR) findings of focal eosinophilic liver disease using gadoxetic acid (Gd-EOB-DTPA).

Materials and Methods

Nineteen patients (M:F=14:5; age range, 26–66 years; mean age, 50 years) with 35 focal eosinophilic liver lesions were included after reviewing the medical records of 482 patients who underwent Gd-EOB-DTPA-enhanced MR imaging (MRI) on a 3.0-T unit between April 2008 and June 2009. The diagnosis of focal eosinophilic liver disease was established by means of percutaneous liver biopsy or surgery and consistent clinical findings. Two radiologists retrospectively reviewed MR images with consensus. Margin, shape and distribution of the lesions were analyzed. We also evaluated signal intensity of focal hepatic lesions on T1- and T2-weighted images and patterns of enhancement in dynamic contrast study.

Results

The mean diameter of the lesions was 1.7 cm (range, 0.7–6.1 cm). Most of the focal eosinophilic liver lesions [n=31/35 (88.6%)] had poorly defined margins. They were usually isointense or slightly hypointense [n=34/35 (97.2%)] on T1-weighted images and hyperintense [n=32/35 (91.4%)] on T2-weighted images. Dynamic study showed enhancement (rim or homogeneous) on the arterial phase [n=21/35 (60%)] and hypointensity on the late venous phase [n=31/35 (88.6%)]. All the lesions were hypointense on the hepatobiliary phase images.

Conclusion

Focal eosinophilic liver lesions tend to be hyperintense on the arterial phase and hypointense on the late venous phase during dynamic study of Gd-EOB-DTPA-enhanced MRI. Although these findings mimic other focal hepatic lesions, poorly defined margins of the lesions and peripheral eosinophilia might help distinguish focal eosinophilic liver disease from other hepatic lesions.  相似文献   

12.

Background

The goal of the study was to assess a T2*-weighted MRI sequence for the ability to identify hepatocellular carcinoma (HCC).

Methods

Hepatic iron deposition, which is common in chronic liver disease (CLD), may increase the conspicuity of HCC on GRE imaging due to increased T2* signal decay in liver parenchyma. In this study, a breath-hold T2*-weighted MRI sequence was evaluated by a blinded observer for HCC and the results compared to a reference standard of gadolinium-enhanced MRI in these same patients. Forty-one patients (mean age 56.2 years; 17 females) were included in this approved, retrospective study.

Results

By the reference standard, 14 of 41 patients had a total of 25 HCCs. The sensitivity of the T2*-weighted MR sequence for identifying HCC, per lesion, was 60%, while the specificity was 100%. There was a significantly lower T2* value of liver parenchyma in patients with HCC identified by the T2*-weighted sequence than in those with HCCs which were not identified by the T2*-weighted sequence (27.8±2.2 vs. 21.9±2.1 ms; P=.02).

Conclusions

A T2*-weighted MRI sequence can identify HCC in patients with CLD. This technique may be beneficial for imaging of patients contraindicated for gadolinium.  相似文献   

13.

Purpose

To present diffusion and perfusion magnetic resonance imaging (MRI) characteristics of focal nodular hyperplasia (FNH) of the liver.

Materials and Methods

Thirty-five patients with 52 FNHs (21 were pathologically-confirmed) underwent MRI at 1.5-T device. MR diffusion [diffusion-weighted imaging (DWI)] was performed using a free-breathing single-shot, spin-echo, echo-planar sequence with b gradient factor value of 500 s/mm². MR perfusion [perfusion-weighted imaging (PWI)] consisted of a 3D free-breathing LAVA sequence repeated up to 5 minutes after injection of 7 mL Gd-BOPTA (MultiHance, Bracco, Italy) and 20 mL saline flush at a flow rate of 4 mL/s. Apparent diffusion coefficient (ADC) and time-signal intensity curve (TSIC) were obtained for both normal liver and each FNH by two reviewers in conference; maximum enhancement (ME) percentage, time to peak enhancement (TTP), and maximal slope (MS) were also calculated.

Results

On DWI mean ADC value was 1.624×10− 3 mm2/s for normal liver and 1.629×10− 3 mm2/s for FNH. ADC value for each FNH and the normal liver was not statistically different (P= .936). On PWI, TSIC-Type 1 (quick and marked enhancement and quick decay followed by slowly decaying) was observed in all 52 FNHs, and TSIC-Type 2 (fast enhancement followed by slowly decaying plateau) in all normal livers. The mean ME, TTP and MS values were significantly different for FNH and normal liver (P= .005).

Conclusion

FNHs of the liver showed typical diffusion and perfusion MRI characteristics in all cases. On the ADC map, we could get similar value between the FNHs and the background parenchyma. On the perfusion imaging, FNHs showed a different pattern distinguished from the background liver.  相似文献   

14.

Objectives

A patient with a breast tissue expander may require a diagnostic assessment using magnetic resonance imaging (MRI). To ensure patient safety, this type of implant must undergo in vitro MRI testing using proper techniques. Therefore, this investigation evaluated MRI issues (i.e., magnetic field interactions, heating, and artifacts) at 3-Tesla for a breast tissue expander with a remote port.

Methods

A breast tissue expander with a remote port (Integra Breast Tissue Expander, Model 3612-06 with Standard Remote Port, PMT Corporation, Chanhassen, MN) underwent evaluation for magnetic field interactions (translational attraction and torque), MRI-related heating, and artifacts using standardized techniques. Heating was evaluated by placing the implant in a gelled-saline-filled phantom and MRI was performed using a transmit/receive RF body coil at an MR system reported, whole body averaged specific absorption rate of 2.9-W/kg. Artifacts were characterized using T1-weighted and GRE pulse sequences.

Results

Magnetic field interactions were not substantial and, thus, will not pose a hazard to a patient in a 3-Tesla or less MRI environment. The highest temperature rise was 1.7 °C, which is physiologically inconsequential. Artifacts were large in relation to the remote port and metal connector of the implant but will only present problems if the MR imaging area of interest is where these components are located.

Conclusions

A patient with this breast tissue expander with a remote port may safely undergo MRI at 3-Tesla or less under the conditions used for this investigation. These findings are the first reported at 3-Tesla for a tissue expander.  相似文献   

15.

Purpose

The purpose was to describe magnetic resonance imaging (MRI) findings of breast cancer liver metastasis using gadoxetic acid (Gd-EOB-DTPA) with an emphasis on the added value of the hepatobiliary phase (HBP).

Material and methods

Nine patients with 13 liver metastases were included in the study after the medical records of 29 breast cancer patients who underwent Gd-EOB-DTPA-enhanced MRI between February 2008 and June 2010 were reviewed. The diagnoses of liver metastasis were established by percutaneous liver biopsy or surgery and on the basis of image findings. Two radiologists retrospectively evaluated signal intensity (SI) and sizes of metastases and patterns of enhancement in an HBP. The SI ratio was calculated as the SI of the central hyperintense portion in “target” lesions divided by the SI of nearby normal liver parenchyma on the HBP. We also measured apparent diffusion coefficient (ADC) values from Diffusion Weighted Image (DWI).

Results

Liver metastases were all hypointense [n=13/13 (100%)] on T1-weighted imaging (WI), and many lesions had a “target” appearance with a central high SI and a peripheral low SI rim (47%) on T2WI. Dynamic study showed rim enhancement on the arterial phase (85%) and a “target” appearance, consisting of a central enhancing portion with peripheral washout or hypointense rim, on the HBP (62%). The mean SI ratio was 0.7. The mean ADC value of “target” appearing metastases was 1.25 (×10−3 mm2/s; range 1.3–1.6) compared with a mean value of 0.8 (×10−3 mm2/s; range 0.8–1.4) in homogeneous defect on the HBP. There was statistically significant difference (P<.05).

Conclusion

Breast cancer liver metastases commonly demonstrated as a peripheral ring enhancement on arterial dominant phase and a target sign with a central round enhancing portion and a peripheral hypointense rim on the HBP.  相似文献   

16.

Objective

To evaluate the image findings of focal fat deposition (FFD) in the liver on gadobenate dimeglumine (Gd-BOPTA)- and gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI, particularly during the hepatobiliary phase (HBP), and the relationship between relative enhancement (RE) and fat signal fraction (FSF) of FFD.

Subjects and Methods

Twenty-one patients with 27 FFDs (mean diameter, 21.9 mm), which showed low signal intensity on opposed-phase compared with in-phase MRI, were retrospectively evaluated. RE of the liver (REliver) and FFD (REFFD) and liver-to-lesion contrast-to-noise ratio (CNR) of FFD were measured on dynamic phases and HBP images with fat-saturated in-phase gradient-echo sequence. The FSF of each FFD was measured on in- and opposed-phase dual gradient-echo images. We qualitatively analyzed imaging findings of FFDs, including signal intensity, shape, margin, and homogeneity on HBP images, and enhancement pattern during dynamic phases. The correlations between REFFD and FSF and between CNR and FSF on HBP images were evaluated using Pearson’s correlation tests and a simple linear regression model.

Results

There were no significant differences between REFFD and REliver in dynamic phases and HBP, regardless of contrast agents (p ≥ 0.075). On HBP images, CNR (p = 0.008) but not REFFD (p = 0.122) was significantly correlated with FSF of FFDs (mean FSF, 19%). On HBP images, 21 of the 27 (77.8%) FFDs were hypointense, and 17 (63%) were homogeneous. Of the 21 hypointense FFDs, 12 (57.1%) had an ovoid shape and 11 (52.4%) were well margined. Although the 27 FFDs showed various enhancement patterns, 17 (63%) showed no enhancement.

Conclusion

Most FFDs appeared as hypointense lesions on Gd-BOPTA- and Gd-EOB-DTPA-enhanced MRI during HBP, with various enhancement patterns during dynamic contrast-enhanced phases. REFFD on HBP images was not significantly correlated with FSF of low grade FFDs.  相似文献   

17.

Objective

Development of a fast 3D high-resolution magnetic resonance imaging (MRI) protocol for improved carotid artery plaque imaging.

Methods

Two patients with carotid atherosclerosis disease underwent 3D high-resolution MRI which included time-of-flight and T1-weighted variable flip angle, fast-spin-echo (FSE) imaging, pre- and post-intravenous gadolinium-based contrast agent administration.

Results

Good quality images with intrinsic blood suppression were obtained pre- and post-contrast administration using a 3D FSE sequence. The plaque burden, lipid core volume, hemorrhage volume and fibrous cap thickness were well determined.

Conclusions

3D high-resolution MR imaging of carotid plaque using TOF and 3D FSE can achieve high isotropic resolution, large coverage, and excellent image quality within a short acquisition time.  相似文献   

18.

Purpose

To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease.

Materials and methods

We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, and 34 benign lesions (≤ 2.0 cm), and 22 patients with cirrhosis but no focal liver lesion who underwent 3.0 T liver MRI. Noncontrast MRI set (T1- and T2-weighted images and DWI) and standard MRI set (gadoxetic acid-enhanced and noncontrast MRI) were analyzed independently by three observers to detect liver malignancies using receiver operating characteristic analysis.

Results

The Az value of the noncontrast MRI (mean, 0.906) was not inferior to that of the combined MRI (mean, 0.924) for detecting malignancies by all observers (P > 0.05). For each observer, no significant difference was found in the sensitivity and specificity between the two MRI sets for detecting liver malignancies and distinguishing them from benign lesions (P > 0.05), whereas negative predictive value was higher with the combined MRI than with the noncontrast MRI (P = 0.0001). When using pooled data, the sensitivity of the combined MRI (mean 94.8%) was higher than that of the noncontrast MRI (mean, 91.7%) (P = 0.001), whereas specificity was equivalent (78.6% vs 77.5%).

Conclusion

Noncontrast MRI including DWI showed reasonable performance compared to the combined gadoxetic acid-enhanced and noncontrast MRI set for detecting HCC and cholangiocarcinoma and differentiating them from benign lesions in patients with chronic liver disease.  相似文献   

19.

Objectives

We conducted a pilot study to identify whether MRI parameters are sensitive to hormone-induced changes in the breast during the natural menstrual cycle and whether changes could also be observed during an oral contraceptive (OC) cycle.

Materials and Methods

The New York University Langone Medical Center Institutional Review Board approved this HIPAA-compliant prospective study. All participants provided written informed consent. Participants were aged 24-31 years.We measured several non-contrast breast MRI parameters during each week of a single menstrual cycle (among 9 women) and OC cycle (among 8 women). Hormones were measured to confirm ovulation and classify menstrual cycle phase among naturally cycling women and to monitor OC compliance among OC users. We investigated how the non-contrast MRI parameters of breast fibroglandular tissue (FGT), apparent diffusion coefficient (ADC), magnetization transfer ratio (MTR), and transverse relaxation time (T2) varied over the natural and the OC cycles.

Results

We observed significant increases in MRI FGT% and ADC in FGT, and longer T2 in FGT in the luteal vs. follicular phase of the menstrual cycle. We did not observe any consistent pattern of change for any of the MRI parameters among women using OCs.

Conclusions

MRI is sensitive to hormone-induced breast tissue changes during the menstrual cycle. Larger studies are needed to assess whether MRI is also sensitive to the effects of exogenous hormones, such as various OC formulations, on the breast tissue of young premenopausal women.  相似文献   

20.

Purpose

Here we describe our first experience with contrast-enhanced (CE) MRI of breast cancer at 7 tesla (T), compared to 3 T and histopathology.

Materials and Methods

A 52 year old female patient with a mammographically suspicious breast mass (BI-RADS V) underwent 7 T CE-MRI. Results were described according to the BI-RADS-MRI criteria and compared to 3 T and histopathology.

Results

After contrast administration, a homogeneously enhancing, irregular spiculated mass was depicted at both 3 T and 7 T; sizes were identical. The most malignant kinetic curve was characterized by a rapid initial rise followed by a wash-out pattern in the delayed phase, i.e. a type 3 curve, at both field strengths. Even though T1-effects of contrast agents are suggested to be reduced at higher fields, quantification of contrast enhancement-to-noise ratio showed a ratio of 4.6 at 7 T and 2.8 at 3 T when comparing contrast-to-noise of the mass before and after contrast administration. Both examinations, using a single dose of gadolinium-based contrast agent, achieved good image quality. Final histopathological evaluation showed an invasive ductulolobular carcinoma with an intraductal component.

Conclusion

This initial experience suggests that clinical contrast-enhanced 7 T MRI of the breast is technically feasible and may allow BI-RADS-conform analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号