首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A convenient, selective and sensitive liquid chromatographic-electrospary ionization mass spectrometry (LC–ESI–MS) method was developed and validated to determine lovastatin in human plasma. The analyte was extracted from human plasma samples by typical liquid–liquid extraction, separated on a C18 column by using the mobile phase consisting of water–methanol (13:87, v/v). Simvastatin was used as the internal standard (IS). The method was linear within the range of 0.1–20 ng mL−1. The lower limit of quantification (LLOQ) was 0.1 ng mL−1. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 10.2%. The accuracy as determined from QC samples was in the range of 99.3–102.9% for the analyte. The mean recoveries for lovastatin and IS were 84.8 and 88.0%, respectively. The method was successfully applied for evaluation of the pharmacokinetic of lovastatin in healthy volunteers.  相似文献   

2.
Metabolism of four tobacco-specific N-nitrosamines (TSNAs), N′-nitrosonornicotine (NNN), N′-nitrosoanatabine (NAT), N′-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) has been studied by solid-phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS–MS). 4-(Methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL) was used as internal standard. SPE and LC–MS–MS was found to be a rapid, simple, sensitive, and selective method for analysis of TSNAs in rabbit serum. The relative standard deviation (R.S.D., n = 6) for analysis of 5 ng mL−1 and 0.5 ng mL−1 standards and of serum sample spiked with 5 ng mL−1 standards of five TSNAs was 2.1–11% and recovery of 5 ng mL−1 standards from serum was 100.2–112.9%. A good linear relationship was obtained between peak area ratio and concentration in the range of 0.2–100 ng mL−1 for NNAL and 0.5–100 ng mL−1 for other four TSNAs, with correlation coefficients (R 2) >0.99 (both linear and log–log regression). Detection limits for standards in solvent were between 0.04 and 0.10 ng mL−1. Doses of TSNAs administered to rabbits via the auricular vein were 4.67 μg kg−1 and 11.67 μg kg−1, in accordance with the different levels in cigarettes. Metabolic curves were obtained for the four TSNAs and for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a metabolite of NNK; on the basis of these curves we modeled metabolic kinetic equations for these TSNAs by nonlinear curve fitting.  相似文献   

3.
A rapid, sensitive, and specific method for quantification of olmesartan, the prodrug of olmesartan medoxomil, in human plasma, using zidovudine as internal standard, is described. Sample preparation involved a simple solid-phase extraction procedure. The extract was analyzed by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry (LC–MS–MS). Chromatography was performed isocratically on a 5 μm C18 analytical column (50 mm × 4.6 mm i.d.) with water–acetonitrile–formic acid 20:80:0.1 (v/v) as mobile phase. The response to olmesartan was a linear function of concentration over the range 4.82–1,928 ng mL−1. The lower limit of quantification in plasma was 4.82 ng mL−1. The method was successfully applied in a bioequivalence study of an olmesartan formulation after administration as a single oral dose.  相似文献   

4.
The purpose of this investigation was to develop a method for measuring the concentration of octylonium in human plasma. Hydrochloric acid was added to the plasma samples before pretreatment to improve the stability of the octylonium. After liquid–liquid extraction with ethylacetate and isopropanol (10:1), the analytes were separated by chromatography on a reversed-phase C18 column and detected by LC–MS–MS with electrospray ionization–ionization. The coefficient of variation for the precision of the assay was less than 10.1%, and the accuracy ranged from 98.0 to 106.5%. The limit of quantification or sensitivity was 0.2 ng mL−1. This method was validated by measuring octylonium in the plasma of healthy human subjects after administration of a single 120-mg oral dose of octylonium bromide. Thus, a highly sensitive and accurate analytical method was developed to determine the concentration of octylonium in human plasma.  相似文献   

5.
Two alternatives for the rapid simultaneous quantification of six sulfonylurea herbicides and five of their main degradation products in natural water are proposed. For concentration, the compounds were extracted on a polystyrene–divinylbenzene solid phase under pH and elution conditions that suppressed any hydrolysis. The eluates were analysed by liquid chromatography coupled to electrospray tandem mass spectrometry within 20 min. The whole method was validated and shown to give no hydrolysis artefacts. The application of off-line and on-line SPE of sulfonylureas enabled the 0.1 μg L−1 and 1 ng L−1 LOQ levels to be reached, respectively. The on-line SPE–LC–MS–MS method allowed the accurate quantitation of all sulfonylureas and three degradation products at 0.1 μg L−1 or below in natural water, with an average repeatability of 8%.  相似文献   

6.
In this study, the development and validation of an analytical method for triptolide in whole blood using high-performance liquid chromatography coupled with atmospheric-pressure chemical ionization ion trap tandem mass spectrometry (LC–APCI-IT-MS-MS) is reported. This is the first report of the systematic development and validation of an LC–MS-MS method for the quantitation of triptolide in human whole blood using prednisolone as an internal standard (IS). Prior to LC–MS-MS analysis, liquid–liquid extraction with ethyl acetate was used to isolate them from the biological matrix. Validation parameters such as specificity/selectivity, limit of quantitation (LOQ), linearity, precision, accuracy and stability are evaluated for this method. The calibration curve was linear (r 2 = 0.9973) in the concentration range of 0.5–100.0 ng mL−1 in human whole blood with a lower limit of quantitation of 0.5 ng mL−1. Intra- and inter-day relative standard deviations (RSDs) were less than 8.6 and 11.7%, respectively. Extraction recoveries of triptolide ranged from 81.5 to 88.1%. This assay can be used to determine trace triptolide in human whole blood.  相似文献   

7.
A new method is described for simultaneous determination of 3-methylindole (3MI) and indole in porcine adipose tissue. Sample preparation included liquid–liquid extraction with n-hexane and 75% aqueous acetonitrile. The acetonitrile extracts were analysed by liquid chromatography–mass spectrometry (LC–MS) using atmospheric pressure chemical ionization (APCI) with selective ion monitoring of protonated ions [M + H]+. This method showed excellent linearity over the concentration range tested (from 2 to 500 ng mL−1 for 3MI and from 1 to 500 ng mL−1 for indole) and good accuracy (recovery of 92 ± 10% for 3MI and 91 ± 10% for indole). This new LC–MS method was compared with traditional colorimetric method for 3MI equivalent. Additionally, the correlation between 3MI concentrations in adipose tissue and plasma was studied. The described LC–MS method can be used to quantify 3MI and indole in porcine adipose tissue in various endocrinological or meat science studies.  相似文献   

8.
A rapid, sensitive, and simple HPLC–MS–MS method, with electro-spray ionization and cetirizine as internal standard (IS), has been developed and validated for simultaneous quantification of fexofenadine and pseudoephedrine in human plasma. The analytes were isolated from plasma by solid-phase extraction (SPE) on Oasis HLB cartridges. The compounds were chromatographed on an RP 18 column with a mixture of ammonium acetate (10 mm, pH 6.4) and methanol as mobile phase. Quantification of the analytes was based on multiple reaction monitoring (MRM) of precursor-to-product ion pairs m/z 502 → 466 for fexofenadine, m/z 166 → 148 for pseudoephedrine, and m/z 389 → 201 for cetirizine. The linear calibration range for both analytes was 2–1,700 ng mL−1 (r = 0.995), based on analysis of 0.1 mL plasma. Extraction recovery was 91.5 and 80.88% for fexofenadine and pseudoephedrine, respectively. The method was suitable for analysis of human plasma samples obtained 72 h after administration of a drug containing both fexofenadine and pseudoephedrine.  相似文献   

9.
A survey of contamination of surface and drinking waters around Lake Maggiore in Northern Italy with polar anthropogenic environmental pollutants has been conducted. The target analytes were polar herbicides, pharmaceuticals (including antibiotics), steroid estrogens, perfluorooctanesulfonate (PFOS), perfluoroalkyl carboxylates (including perfluorooctanoate PFOA), nonylphenol and its carboxylates and ethoxylates (NPEO surfactants), and triclosan, a bactericide used in personal-care products. Analysis of water samples was performed by solid-phase extraction (SPE) then liquid chromatography–triple-quadrupole (tandem) mass spectrometry (LC–MS–MS). By extraction of 1-L water samples and concentration of the extract to 100 μL, method detection limits (MDLs) as low as 0.05–0.1 ng L−1 were achieved for most compounds. Lake-water samples from seven different locations in the Southern part of Lake Maggiore and eleven samples from different tributary rivers and creeks were investigated. Rain water was also analyzed to investigate atmospheric input of the contaminants. Compounds regularly detected at very low concentrations in the lake water included: caffeine (max. concentration 124 ng L−1), the herbicides terbutylazine (7 ng L−1), atrazine (5 ng L−1), simazine (16 ng L−1), diuron (11 ng L−1), and atrazine-desethyl (11 ng L−1), the pharmaceuticals carbamazepine (9 ng L−1), sulfamethoxazole (10 ng L−1), gemfibrozil (1.7 ng L−1), and benzafibrate (1.2 ng L−1), the surfactant metabolite nonylphenol (15 ng L−1), its carboxylates (NPE1C 120 ng L−1, NPE2C 7 ng L−1, NPE3C 15 ng L−1) and ethoxylates (NPE n Os, n = 3-17; 300 ng L−1), perfluorinated surfactants (PFOS 9 ng L−1, PFOA 3 ng L−1), and estrone (0.4 ng L−1). Levels of these compounds in drinking water produced from Lake Maggiore were almost identical with those found in the lake itself, revealing the poor performance of sand filtration and chlorination applied by the local waterworks.  相似文献   

10.
To evaluate the pharmacokinetics of a novel analogue of ginkgolide B, 10-O-dimethylaminoethylginkgolide B (XQ-1) in rat plasma in pre-clinical studies, a sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry detection (LC–ESI–MS) was developed and validated. After a simple extraction with ethyl acetate, XQ-1 was analyzed on a Shim-pack C18 column with a mobile phase of a mixture of 1 μmol L−1 ammonium acetate containing 0.02% formic acid and methanol (55:45, v/v) at a flowrate of 0.3 mL min−1. Detection was performed in selected ion monitoring (SIM) mode using target ions at [M + H]+ m/z 496.05 for XQ-1 and m/z 432.10 for the internal standard (lafutidine). Linearity was established for the concentration range from 2 to 1,000 ng mL−1 . The extraction recoveries ranged from 86.0 to 89.9% in plasma at concentrations of 5, 50, and 500 ng mL−1. The lower limit of quantification was 2 ng mL−1 with 100 μL plasma. The validated method was successfully applied to a pharmacokinetic study after intragastic administration of XQ-1 mesylate in rats at a dose of 20 mg kg−1.  相似文献   

11.
A validated, highly sensitive, and selective HPLC method with MS–MS detection has been developed for quantitative determination of azithromycin (AZI) in human Na2EDTA plasma. Roxithromycin (ROX) was used as internal standard. Human plasma containing AZI and internal standard was ultrafiltered through Centrifree Micropartition devices and the concentration of AZI was determined by isocratic HPLC–MS–MS. Multiple reaction monitoring mode (MRM) was used for MS–MS detection. The calibration plot was linear in the concentration range 2.55–551.43 ng mL−1. Inter-day and Intra-day precision and accuracy of the proposed method were characterized by R.S.D and percentage deviation, respectively; both were less than 8%. Limit of quantification was 2.55 ng mL−1. The proposed method was used to determine the pharmacokinetic profile of AZI (250-mg tablets).  相似文献   

12.
A sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry (LC–ESI-MS) has been developed and validated for identification and quantification of mitiglinide in human urine. A simple liquid–liquid extraction procedure was followed by separation on a C18 column with gradient elution, and detection using a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. The method was tested using six different batches of urine. Linearity was established for the mitiglinide concentrations in the range 0.005–1.0 μg mL−1, with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. Intra- and inter-day precision (as RSD, %) was below 10% and accuracy for mitiglinide ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.002 μg mL−1 for 500 μL urine. The proposed method enables unambiguous identification and quantification of mitiglinide in pre-clinical and clinical studies.  相似文献   

13.
A liquid chromatography–electrospray-tandem mass spectrometry (LC–ESI-MS–MS) method based on the detection of biomarker peptides from allergenic proteins was devised for confirming and quantifying peanut allergens in foods. Peptides obtained from tryptic digestion of Ara h 2 and Ara h 3/4 proteins were identified and characterized by LC–MS and LC–MS–MS with a quadrupole-time of flight mass analyzer. Four peptides were chosen and investigated as biomarkers taking into account their selectivity, the absence of missed cleavages, the uniform distribution in the Ara h 2 and Ara h 3/4 protein isoforms together with their spectral features under ESI-MS–MS conditions, and good repeatability of LC retention time. Because of the different expression levels, the selection of two different allergenic proteins was proved to be useful in the identification and univocal confirmation of the presence of peanuts in foodstuffs. Using rice crispy and chocolate-based snacks as model food matrix, an LC–MS–MS method with triple quadrupole mass analyzer allowed good detection limits to be obtained for Ara h2 (5 μg protein g−1 matrix) and Ara h3/4 (1 μg protein g−1 matrix). Linearity of the method was established in the 10–200 μg g−1 range of peanut proteins in the food matrix investigated. Method selectivity was demonstrated by analyzing tree nuts (almonds, pecan nuts, hazelnuts, walnuts) and food ingredients such as milk, soy beans, chocolate, cornflakes, and rice crispy. Figure ESI-QTOF-MS mass spectrum of Ara h3/4 triptig digest  相似文献   

14.
Olprinone is a phosphodiesterase (PDE)-3 inhibitor. This paper describes a simple, selective and sensitive method for the quantification of olprinone in rat plasma using a liquid–liquid extraction procedure followed by liquid chromatography mass spectrometric (LC–MS) analysis. The method had an advantage of high sensitivity. Analyses were conducted at a flow rate of 0.25 mL min−1 by a gradient elution. The detection utilized selected ion monitoring in the positive ion mode at m/z 251.0 and 344.0 for the protonated molecular ions of olprinone and the internal standard, respectively. The quantitation limit for olprinone in rat plasma was 0.5 ng mL−1. The linearity was also excellent over the concentration range of 0.5–100 ng mL−1 of olprinone. The intra- and inter-day precision (relative standard deviation (RSD) %) was lower than 10%, and accuracy ranged from 90 to 110%. This developed method was successfully applied to analysis of olprinone in biological fluids.  相似文献   

15.
Liquid chromatography (LC) hyphenated with both elemental and molecular mass spectrometry has been used for Se speciation in Se-enriched garlic. Different species were separated by ion-pair liquid chromatography–inductively coupled plasma mass spectrometry (LC–ICP–MS) after hot-water extraction. They were identified by on-line reversed-phase liquid chromatography–electrospray ionization tandem mass spectrometry (RPLC–ESI–MS–MS). Se-methionine and Se-methylselenocysteine were determined by monitoring their product ions. Another compound, γ-glutamyl-Se-methylselenocysteine, shown to be the most abundant form of Se in the garlic, was determined without any additional sample pre-treatment after extraction and without the need for a synthesized standard. Product ions for this dipeptide were detected by LC–ESI–MS–MS for three isotopes of Se78 Se, 80Se: and 82Se. The method was extended to the species extracted during in-vitro gastrointestinal digestion. Because both Se-methylselenocysteine and γ-glutamyl-Se-methylselenocysteine have anticarcinogenic properties, their extractability and stability during human digestion are very important. Garlic was also treated with saliva, to enable detection and analysis of species extracted during mastication. Detailed information on the extractability of selenium species by both simulated gastric and intestinal fluid are given, and variation of the distribution of Se among the different species with time is discussed. Although the main species in garlic is the dipeptide γ-glutamyl-Se-methylselenocysteine, Se-methylselenocysteine is the main compound present in the extracts after treatment with gastrointestinal fluids. Two more, so far unknown compounds were observed in the chromatogram. The extracted species and their transformations were analysed by combining LC–ICP–MS and LC–ESI–MS–MS. In both the simulated gastric and intestinal digests, Se-methionine, Se-methylselenocysteine, and γ-glutamyl-Se-methylselenocysteine could be determined by LC–ESI–MS–MS by measuring their typical product ions.   相似文献   

16.
In recent years perfluorinated alkylated substances (PFAS) have appeared as a new class of global pollutant. Besides being an industrially important group of compounds, PFAS are regarded as highly toxic and extraordinarily persistent chemicals that pervasively contaminate human blood and wildlife throughout the world. They are therefore regarded as PBT (persistent, bioaccumulative, and toxic) chemicals. Two comprehensive methods have been developed for determination of eleven of the most environmentally relevant PFAS (seven perfluoroalkylcarboxylates, two perfluoroalkylsulfonates, and two perfluoroctanesulfonamides) in aqueous samples. The compounds were isolated by liquid–liquid extraction (LLE) and solid-phase extraction (SPE), and identification and quantification of the target analytes were achieved by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS–MS). With LLE detection limits ranged from 0.26 to 0.62 ng L−1 for enrichment of 900-mL water samples; recovery of PFAS with a carbon chain longer than C7 was excellent (80–93%). With SPE, carboxylates with carbon chains <C10 could be extracted efficiently (70–98%) under acidic conditions, and PFOS and PFOSA could be extracted efficiently (81% and 96%, respectively) under basic conditions, resulting in MDLs between 0.25 and 0.64 ng L−1. The LLE method was applied successfully to Austrian wastewater effluent samples.  相似文献   

17.
To support preclinical pharmacokinetic investigation of 1-[4-[2-(4-bromobenzene-sulfonaminoethyl)phenylsufonyl]-3-(trans-4-methylcyclohexyl)urea (G004), a rapid, sensitive and specific high-performance liquid chromatography–electrospray ionization mass spectrometry (LC–ESI-MS) method was developed and validated. Glibenclamide was employed as internal standard. After liquid–liquid extraction the analyte was analyzed on a Kromasil C18 column (150 × 2.0 mm i.d.) with a mobile phase consisted of acetonitrile–water (0.05% acetic acid), 30:70 (v/v). The flow rate was 0.2 mL min−1. Detection was performed on a quadrupole mass spectrometer using an electrospray ionization interface and the selected-ion monitoring (SIM) mode. The retention time was about 3.5 and 4.2 min for Glibenclamide and G004, respectively. The assay was linear over the concentration range of 2.0–500.0 ng mL−1. Extraction Recovery of G004 in rat plasma was more than 87%. The intra- and inter-assay precision was lower than 11.5% (CV). This validated method was successfully applied to the pharmacokinetics of G004 in rats.  相似文献   

18.
Cholesterol-reducing statin drugs are the most frequently prescribed agents for reducing morbidity and mortality related to coronary heart disease. In this publication a validated, highly sensitive, and selective isocratic HPLC method is reported for quantitative determination of the major statin drug atorvastatin (ATV) and its metabolite 2-hydroxyatorvastatin (HATV). Detection was performed with an electrospray ionization triple-quadrupole mass spectrometer equipped with an ESI interface operating in positive-ionization mode. Multiple reaction monitoring (MRM) was used for MS–MS detection. The calibration plot was linear in the concentration range 0.10–40.00 ng mL−1 for both ATV and HATV. Inter-day and intra-day precision and accuracy of the proposed method were characterized by measurement of relative standard deviation (RSD) and percentage deviation, respectively; both were less than 8% for both analytes. The limit of quantitation was 0.02 ng mL−1 for ATV and 0.07 ng mL−1 for HATV. The method was used for pharmacokinetic study of ATV and HATV. Pharmacokinetic data for all analytes are also reported.  相似文献   

19.
Liquid chromatography–fluorescence (LC–FLS), liquid chromatography–tandem mass spectrometry (LC–MS/MS) and inductively coupled plasma–mass spectrometry (ICP-MS) methods were developed and validated for the evaluation of motexafin gadolinium (MGd, Xcytrin) pharmacokinetics and biodistribution in plasma and tissues. The LC–FLS method exhibited the greatest sensitivity (0.0057 μg mL−1), and was used for pharmacokinetic, biodistribution, and protein binding studies with small sample sizes or low MGd concentrations. The LC–MS/MS method, which exhibited a short run time and excellent selectivity, was used for routine clinical plasma sample analysis. The ICP–MS method, which measured total Gd, was used in conjunction with LC methods to assess MGd stability in plasma. All three methods were validated using human plasma. The LC–FLS method was also validated using plasma, liver and kidneys from mice and rats. All three methods were shown to be accurate, precise and robust for each matrix validated. For three mice, the mean (standard deviation) concentration of MGd in plasma/tissues taken 5 hr after dosing with 23 mg kg−1 MGd was determined by LC–FLS as follows: plasma (0.025±0.002 μg mL−1), liver (2.89±0.45 μg g−1), and kidney (6.09±1.05 μg g−1). Plasma samples from a subset of patients with brain metastases from extracranial tumors were analyzed using both LC–MS/MS and ICP–MS methods. For a representative patient, ≥90% of the total Gd in plasma was accounted for as MGd over the first hour post dosing. By 24 hr post dosing, 63% of total Gd was accounted for as MGd, indicating some metabolism of MGd.  相似文献   

20.
In the framework of developing analyses for exogenous contaminants in food matrices such as honey, we have compared data obtained by high-performance liquid chromatography coupled with mass spectrometry (LC–MS) to those provided by high-performance liquid chromatography and tandem mass spectrometry (LC–MS–MS). Initial results obtained with LC–MS showed that the technique lacked selectivity, which is why the method was validated by LC–MS–MS. This method involves a solid-phase extraction (SPE) of nitrofuran metabolites and nitrofuran parent drugs, a derivatization by 2-nitrobenzaldehyde for 17 h, and finally a clean-up by SPE. The data obtained show that the limits of detection varied between 0.2 and 0.6 μg kg−1 for the metabolites and between 1 and 2 μg kg−1 for nitrofuran parent drugs. The method was applied to different flower honeys. The results showed that nitrofurans (used as antibiotics) are consistently present in this matrix, the predominant compound being furazolidone. Figure Working bees  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号