1.
Recent improvements in the LC-MS interface have increased the sensitivity and selectivity of this instrument in the analysis of polar and thermally-labile aqueous constituents. Determination of RDX, nitroso-RDX metabolites, and other munitions was enhanced using LC-MS with solid-phase extraction, 15N3-RDX internal standard, and electrospray ionization (ESI) in negative ion mode. ESI produced a five-fold increase in detector response over atmospheric pressure chemical ionization (APCI) for the nitramine compounds, while the more energetic APCI produced more than twenty times the ESI response for nitroaromatics. Method detection limits in ESI for nitramines varied from 0.03 microgram l-1 for MNX to 0.05 microgram l-1 for RDX.  相似文献   

2.
A new LC/MS method was developed for the analysis of sixteen different analytes including the most common organic explosives encountered in forensic investigations. The separation was achieved using a porous graphitic carbon (PGC) column with a binary gradient elution. Molecular modeling suggested a possible interpretation for the elution order of explosive compounds on PGC. The introduction of ammonium formate in the mobile phase resulted in the formation of characteristic adduct ions thus enhancing the mass spectrometric detection of nitrate ester and nitramine compounds. Atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) were compared in terms of sensitivity. The final LC/APCI-MS method allowed easy identification of investigated compounds with limits of detection ranging from 0.04 to 1.06 ng/microl. The analysis of simulated forensic samples confirmed the performance of the method.  相似文献   

3.
A discharge adaptor, composed of a metal casing and platinum (Pt) wire needle, was directly attached to an electrospray ionization (ESI) probe tip, to transform the ionization into atmospheric pressure chemical ionization (APCI). Six generic drugs were analyzed with the developed discharge adaptor (DA) and two commercial interfaces. The DA interface produced more intense radical anions, [M].–, and less sodium adduct ions, [M + Na]+, than the ESI interface, whereas almost the same molecular ions were detected as the APCI interface. The effects of solvent and desolvation gas flow in the DA interface were similar to those in the ESI interface, but differed from those in the APCI interface. Better sensitivity of the tested drugs was obtained relative to the commercial APCI interface. For human plasma samples, the DA interface also demonstrated good tolerance to plasma matrices, linearity from 5 or 20 to 500 ng/mL (r2 > 0.99) and ruggedness. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human plasma samples was developed. The absolute minimum detection limit was around 10-20 pg per injection, corresponding to 0.5 ppb in an injection equivalent to 20-40microg of human plasma. Ochratoxin B (OTB) was used as an internal standard and its absence in real-life samples was carefully checked before samples were spiked with the internal standard. It was found that these two ochratoxins are susceptible to sodium adduct formation. Fragment ions from the [M + H](+) and [M + Na](+) ions of both OTA and OTB were monitored in the multiple reaction monitoring mode. Three quantitative approaches, standard addition method, internal standard method (using ochratoxin B as an internal standard) and external standard method, were compared in the analysis of human blood plasma. Results from the mass spectrometric method were comparable to those from a conventional LC/fluorescence method. The LC/MS/MS method was also applied to the analysis of contaminated coffee samples.  相似文献   

5.
The development of rapid, efficient, and reliable detection methods for the characterization of energetic compounds is of high importance to security forces concerned with terrorist threats. With a mass spectrometric approach, characteristic ions can be produced by attaching anions to analyte molecules in the negative ion mode of electrospray ionization mass spectrometry (ESI‐MS). Under optimized conditions, formed anionic adducts can be detected with higher sensitivities as compared with the deprotonated molecules. Fundamental aspects pertaining to the formation of anionic adducts of 1,3,5,7‐tetranitro‐1,3,5,7‐tetrazocane (HMX), 1,3,5‐trinitro‐1,3,5‐triazinane (RDX), pentaerythritol tetranitrate (PETN), nitroglycerin (NG), and 1,3,5‐trinitroso‐1,3,5‐triazinane energetic (R‐salt) compounds using various anions have been systematically studied by ESI‐MS and ESI tandem mass spectrometry (collision‐induced dissociation) experiments. Bracketing method results show that the gas‐phase acidities of PETN, RDX, and HMX fall between those of HF and acetic acid. Moreover, PETN and RDX are each less acidic than HMX in the gas phase. Nitroglycerin was found to be the most acidic among the nitrogen‐rich explosives studied. The ensemble of bracketing results allows the construction of the following ranking of gas‐phase acidities: PETN (1530‐1458 kJ/mol) > RDX (approximately 1458 kJ/mol) > HMX (approximately 1433 kJ/mol) > nitroglycerin (1427‐1327.8 kJ/mol).  相似文献   

6.
The HPLC‐DAD and GC/MS methods were successfully used for the identification and characterization of the impurities in an agrochemical insecticide, bifenthrin technical. Three impurities ranging from 0.175%–0.541% were detected by the HPLC‐DAD method. The LC/MS technique with ESI or APCI source failed to detect the impurities detected by HPLC‐DAD, due to lack of ionization in ESI or APCI. The three impurities were enriched by prep‐HPLC, and then their structures were elucidated based on the GC/EIMS and CIMS data. The EI mass spectra of bifenthrin and its impurities displayed molecular ion and provided structure indicative fragment ions; the CIMS data further confirmed their molecular weight. The identity of the impurity 1 was further confirmed by the synthesis of the authentic sample followed by NMR and GC/MS data.  相似文献   

7.
A sonic spray ionization liquid chromatography/mass spectrometry (LC/SSI-MS) procedure combined with off-line solid-phase extraction was optimized for the analysis of 20 endocrine-disrupting chemicals (EDCs) in water samples. Method development included a comparison of the novel sonic spray ionization (SSI) with more traditional ion sources, i.e. pneumatically assisted electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). It was demonstrated that SSI and ESI spectra were very similar, but were more prone to the formation of solvent cluster ions as compared with APCI spectra. This phenomenon was most prominent for SSI and resulted in an increased chemical background in full-scan mass spectra. However, this chemical noise did not affect the overall sensitivity of SSI and ESI. After optimization of LC and MS parameters, the LC/SSI-MS method was validated. Recoveries ranged from 76.3 up to 113.4% for all compounds. Limits of detection (LOD) and quantitation (LOQ) were established between 3.0 and 11.5 ng/L and 9.9 and 38.0 ng/L, respectively. Within-day (n = 5) and between-day (n = 5) reproducibility were investigated at three levels and ranged from 3.3-16.5% and 7.6-19.2%, respectively. Eight-point calibration curves were established and showed linearity for all compounds (r(2) > 0.987) over a linear dynamic range of 10-10 000 ng/L.  相似文献   

8.
The fragmentation pathways of three explosive compounds with similar structures, hexanitrostilbene (HNS), cyclotrimethylene trinitramine (RDX), and 2,4,6-trinitrotoluene (TNT), have been investigated by multiple mass spectrometry (MSn, n = 1, 2, 3) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources. The electron capture mechanism for these compounds in negative ion APCI and ESI mode differs from the usual negative ion mechanism, deprotonation or addition of other species. This was shown for HNS and TNT, which both gave a [M]- anion but not a [M-H]- ion in APCI, and the [M]- anion of HNS was observed in ESI. The quantitative analysis of HNS was performed by liquid chromatography (LC)/ESI-MS, and the results obtained by the internal standard (ISTD) method were compared with those from the external standard (ESTD) method, demonstrating that both quantitation approaches are useful, with good sensitivity, reproducibility and linearity, and ESTD is preferable in routine applications.  相似文献   

9.
Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even‐ and odd‐electron ions, whereas the other ionization techniques produced even‐electron ions only. In‐source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full‐scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6‐dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Quantitative analysis of target compounds with liquid chromatography atmospheric pressure ionization mass spectrometry is sometimes hampered by adduct formation. In these situations, cationization with alkali metal ions instead of proton addition is often observed in the positive ion mode. This work studies the process of adduct formation and investigates potential strategies to control this phenomenon. Paclitaxel, a pharmaceutical chemotherapeutic agent, was used as a model compound. Electrospray (ESI), atmospheric pressure chemical ionization (APCI) and sonic spray ionization (SSI) are evaluated and compared. The work was performed on two different instruments, allowing the evaluation of different ionization behavior for different source design for electrospray, if any. Different mobile phase additives were compared, including acetic acid, formic acid, ammonium formate, and a range of primary amines. Continuous infusion was used for a fast screening, to detect optimal conditions. These were then further investigated in detail by LC-MS. The results indicate that electrospray is the more sensitive interface for this compound on the investigated apparatus. Unacceptable quantitative data were acquired without additives in the mobile phase. Generally, additives increased the reproducibility significantly. A response of mainly one ion was achieved with dodecylamine/acetic acid and acetic acid/sodium acetate. The data also point out the importance of evaluating adduct formation for compounds prone to this phenomenon during method development, especially in view of accurate quantitation.  相似文献   

11.
Qualitative screening procedures have been developed for the rapid detection and identification of the hydrolysis products of chemical warfare agents in aqueous samples and extracts, using liquid chromatography-mass spectrometry with positive and negative atmospheric pressure chemical ionisation (APCI). Previously reported screening procedures, which used positive APCI or electrospray ionisation (ESI), were modified by using LC conditions that allowed acquisition of positive and negative ion mass spectra. APCI was generally found to be more robust than ESI, probably due to variable adduct ion formation with ESI, depending on the condition of the sample and the system. Negative APCI provided selective detection of acidic analytes and allowed facile differentiation of alkyl alkylphosphonic acids from isomeric dialkyl alkylphosphonates. The combination of positive and negative APCI, using a C18 column and water-methanol mobile phase modified with ammonium formate, provides a rapid screening procedure for chemical warfare agent degradation products, with limits of detectability in the range 10-100 ng/ml. In the case of proficiency test samples, where analyte concentrations are in the range 1-10 ppm, introduction of the sample by infusion may provide an even faster preliminary screening procedure.  相似文献   

12.
The liquid chromatography tandem mass spectroscopy residue determination of compounds without any acidic or basic centers such as abamectin has been investigated. Several approaches regarding the interface used and adduct formation have been compared. The low acidity of the hydroxyl groups only made deprotonation feasible using the atmospheric pressure chemical ionization (APCI) interface. To obtain sufficient sensitivity for residue analysis, the Ion Sabre APCI interface was necessary. However, the sensitivity attained was lower than for monitoring adducts in positive ion mode. Using electrospray ionization, different adducts with Na+, NH4+, and Li+ were tested and compared. The best results were obtained for the ammoniated adduct in electrospray ionization (ESI) because of its high sensitivity and the presence of several product ions with similar abundance. The highest sensitivity was reached using an in-source fragment as precursor ion, leading to a limit of detection (LOD) of 2 microg/L with low relative standard deviation. The relatively high abundance of other transitions allowed abamectin confirmation at concentrations close to the LOD (6 microg/L). Alkali ions were found to be a suitable alternative to determine and confirm abamectin at residue levels. The [M + Na]+ also presented various product ions with similar abundance, which allowed confirmation at LOD levels. However, this LOD was found to be almost four times higher than with [M + NH4]+ because of the poor sensitivity of the transitions obtained. Although the use of Li+ facilitated the fragmentation of the adduct [M + Li]+, with similar sensitivity to [M + NH4]+, this fragmentation preferentially generated only one product ion, which did not allow confirmation at concentration levels lower than 15 microg/L. The use of APCI for monitoring adducts was also feasible, but with less sensitivity. The sensitivity increased with the Ion Sabre APCI, although it was still five times lower than with ESI. Other adduct formers such as Co2+ and Ni2+ also were tested with unsatisfactory results.  相似文献   

13.
Olivier Vigneau 《Talanta》2009,77(5):1609-1058
The introduction of chloroform into the nebulising gas of a LC/MS electrospray interface (ESI), in a perfectly controlled way, leads to the formation of intense adducts ([M+Cl]) when a mobile phase containing HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazacyclooctane or octogen) and RDX (1,3,5-trintro-1,3,5-triazacyclohexane or hexogen) is eluted. This LC/MS method allows the direct analysis of aqueous samples containing HMX and RDX at the pictogram level without a concentration step. The method is used to determine HMX and RDX concentrations in ground water samples from a military site.  相似文献   

14.
The fragmentation behavior of taxoids was studied using electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources with multi-stage tandem mass spectrometry. In the positive ion mode taxoids gave prominent [M+Na]+ and [M+K]+ ions with the ESI source, and [M+NH4]+ or [M+H]+ ions with the APCI source. The MS/MS fragmentations of ions produced by APCI and ESI sources were very similar. For both sources, the presence of cinnamoyl or benzoyl groups could be characterized by initial losses of 148 or 122 u, respectively, from molecular adduct ions. However, the elimination of cinnamic acid was relatively difficult for the molecular adduct ions formed by APCI, and was comparable in importance to the loss of acetic acid. The other fragments involved losses of CH2CO, CO, and H2O. The 5/7/6 type taxoids underwent characteristic losses of 58 or 118 u from ions produced by both APCI and ESI sources. The fragmentation behavior was remarkably influenced by substitution locations. The elimination of the C-10 benzoyl group was usually the first fragmentation step, while that of the C-2 benzoyl group was relatively difficult. The acetoxyl group at C-7 was more active than those at C-2, C-9, and C-10, which in turn were more active than that at C-4. These fragmentation rules could facilitate the rapid screening and structural characterization of taxoids in plant extracts by high-performance liquid chromatography/mass spectrometry (HPLC/MS).  相似文献   

15.
Mass spectrometry is an established analytical technique in high-throughput metabolomics, often coupled with ultra-performance liquid chromatographic separation (UPLC). Since ion formation under 'soft' conditions is a complex phenomenon resulting in fragmentation, clustering and adduct formation, the extraction of meaningful information from holistic metabolomic profiling of biological samples requires the understanding of the physicochemical phenomena occurring inside an ionization source. In this paper we investigate the ionization dynamics of two ellagitannins (sanguiin H6 and lambertianin C) by combining state of the art mass spectrometric techniques (MALDI, ESI, APCI), ion mobility (IMS) and NMR. These compounds can be used as prototype of an important class of bio-active compound present in relevant concentrations in some food matrices.  相似文献   

16.
A novel, fast liquid chromatography atmospheric pressure chemical ionization mass spectrometry (LC–APCI–MS/MS) screening method was developed to determine the trace amounts of TNT (trinitrotoluene), RDX (1,3,5-trinitroperhydro-1,3,5-triazine), HMX (cyclotetramethylene-tetranitramine), PETN (pentaerythritoltetranitrate), TETRYL (2,4,6-trinitrophenyl-N-methylnitramine), picric acid (2,4,6 trinitrophenol), 2,6-DNT (2,6-dinitrotoluene), and TMETN (trimethylolethane-trinitrate) which contaminate the soil after explosion. A gradient of 2.00 mM ammonium nitrate aqueous solution-methanol mobile system, C18 column, and atmospheric pressure chemical ionization (APCI) (?) ionization mode was used after a single-step solid–liquid extraction procedure from soil matrix. Phenytoin was used as the internal standard. As an extraordinary application, gas temperature gradient in an APCI ionization was used. Analytes were selectively eluted from the system within 10 min. Average recovery obtained from the soil was between 93.01 and 104.20% at 250.0, 500.0, and 1000.0 ngg?1 concentration levels. Limit of detection (LOD) and limit of quantification (LOQ) values obtained from the analysis of the soil samples including explosive mix were between 8.9–161.2 and 13.2–241.5 ngg?1, respectively.  相似文献   

17.
Mass spectra of transition metal carbonyl cluster anions were recorded using laser desorption ionization time-of-flight (LDI-TOF) and electrospray ionization (ESI) techniques. The LDI spectra generally contain peaks corresponding the intact cluster together with extensive CO loss fragments ions whereas the ESI spectra exhibit peaks corresponding the intact cluster together with few (if any) CO loss fragment ions. The parameters of both techniques can be modified to vary the extent of fragmentation. In all cases no fragmentation of the metal core is observed. Overall, ESI is a more informative method for the analysis of these types of cluster anions.  相似文献   

18.
Mass spectra were acquired for a therapeutic 4-azasteroid (dutasteride), and some related compounds, using various ionization conditions (EI, CI, APCI and ESI) in both positive and negative ion modes. The ionization and fragmentation behavior of the compound dutasteride, its precursors and several analogs is reported. Positive atmospheric pressure chemical ionization (APCI+) and positive electrospray ionization (ESI+) produced distinctive collision-induced dissociation (CID) spectra for the respective [MH]+ ions of dutasteride. The spectral differences are attributed to ion populations having either different structures or different internal energy distributions (as a consequence of the method of ionization). Irrespective of their origin, the protonated molecules undergo interesting fragmentation reactions when collisionally activated. The identity of the major fragmentation products was confirmed by accurate mass measurement. The negative APCI mass spectrum of dutasteride displays extensive dehydrohalogenation, apparently due to the thermal component of the APCI process. Some of the resulting radical anions display remarkable stability toward collisional decomposition. Details of the fragmentation behavior for the negative ion species and their relationship to the positive ion results are discussed.  相似文献   

19.
Use of optimized instrument parameters that result from statistical experimentation revealed that the sensitivity of atmospheric pressure chemical ionization (APCI) liquid chromatography-mass spectrometry (LC/MS) is greater than the sensitivity of an optimized Thermabeam? LC/MS interface by about 3 orders of magnitude, when tested on aromatic compounds. APCI is one of the few LC/MS techniques in which the chromatogram is directly comparable with liquid chromatographs that use ultraviolet detection. The optimum instrument parameters for a Finnigan SSQ-7000 APCI LC/MS interface were found at low flow rates (e. g., 0. 1 mL/min), relatively low capillary heat (e. g., 225 °C), and high sheath-gas pressure (e. g., 60 lb/in2). The optimization was achieved by monitoring the responses of sensitivity, fragmentation, and cluster ion formation. The fine tuning for high sensitivity calls for a high percentage of water in the mobile phase. In contrast, a high percentage of organic content in the mobile phase is required to obtain abundant protonated molecular ions with respect to fragmentation and clustering. This is an important consideration for analyses of unknowns.  相似文献   

20.
Beclomethasone dipropionate (BDP) is a potent pro-drug to beclomethasone (BOH) and is used in the treatment of chronic and acute respiratory disorders in the horse. The therapeutic dose of BDP (325 microg per horse) by inhalation results in very low plasma and urinary concentrations of BDP and its metabolites that pose a challenge to detection and confirmation by equine forensic laboratories. To solve this problem, a method involving the use of a liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) was developed for the detection, confirmation and quantification of the analytes in equine samples. Ammonium formate or acetate buffer added to LC mobile phase favored the formation of [M + H](+) ions from BDP and its metabolites, whereas formic acid led to the formation of sodium and potassium adduct ions ([M + Na](+), [M + K](+)) together with [M + H](+) ions. Acetonitrile, on the other hand, favored the formation of abundant solvent adduct ions [M + H + CH(3)CN](+) with the analytes under electrospray ionization (ESI) and atmospheric pressure chemical ionization conditions. In contrast, methanol formed much less solvent adduct ions than acetonitrile. The solvent adduct ions were thermally stable and could not be completely desolvated under the experimental conditions, but they were very fragile to collision-induced dissociation (CID). Interestingly, these solvent adduct ions were observed on a triple-quadrupole mass spectrometry but not on an ion trap instrument where helium used as a damping gas in the ion trap might cause the solvent adduct ions desolvated by collision. By CID studies on the [M + H](+) ions of BDP and its metabolites, their fragmentation paths were proposed. In equine plasma at ambient temperature over 2 h, BDP and B21P were hydrolyzed in part to B17P and BOH, respectively, but B17P was not hydrolyzed. Sodium fluoride added to equine plasma inhibited the hydrolysis of BDP and B21P. The matrix effect in ESI was evaluated in equine plasma and urine samples. The method involved the extraction of BDP and its metabolites from equine plasma and urine samples by methyl tert-butyl ether, resolution on a C(8) column with a mobile phase gradient consisting of methanol and ammonium formate (2 mmol l(-1), pH 3.4) and multiple reaction monitoring for the analytes on a triple-quadrupole mass spectrometer. The detection limit was 13 pg ml(-1) for BDP and B17P, 25 pg ml(-1) for BOH and 50 pg ml(-1) for B21P in plasma and 25 pg ml(-1) for BOH in urine. The method was successfully applied to the analysis of equine plasma and urine samples for the analytes following administration of BDP to horses by inhalation. B17P, the major and active metabolite of BDP, was detected and quantified in equine plasma up to 4 h post-administration by inhalation of a very low therapeutic dose (325 microg per horse) of BDP.  相似文献   