首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
The protein ribonuclease A (RNase A) represents a good model protein for studying reversible conformational refolding during gradient elution. Work is described utilizing RNase A under gradient conditions to evaluate several different reversed-phase materials. Columns (10 cm x 4.6 mm I.D.) were packed with Partisil C18, Vydac C18, Nucleosil C4, Nucleosil C18 and an adamantyl-modified Partisil silica. Measurements of the apparent first-order rate constant of refolding, as a function of temperature, are presented and compared for each stationary phase. Comparisons of peak shapes as functions of flow-rate and temperature are also discussed.  相似文献   

2.
The development of methods for the separation of enantiomers has attracted great interest in the past 20 years, since it became evident that the potential biological or pharmacological applications are mostly restricted to one of the enantiomers. In the past decade, macrocyclic antibiotics have proved to be an exceptionally useful class of chiral selectors for the separation of enantiomers of biological and pharmacological importance by means of high-performance liquid chromatography (HPLC), thin-layer chromatography and electrophoresis. The glycopeptides avoparcin, teicoplanin, ristocetin A and vancomycin have been extensively used as chiral selectors in the form of chiral bonded phases in HPLC, and HPLC stationary phases based on these glycopeptides have been commercialized. In fact, the macrocyclic glycopeptides are to some extent complementary to one another: where partial enantioresolution is obtained with one glycopeptide, there is a high probability that baseline or better separation can be obtained with another. This review sets out to characterize the physicochemical properties of these macrocyclic glycopeptide antibiotics and, through their application, endeavors to demonstrate the mechanism of separation on macrocyclic glycopeptides. The sequence of elution of the stereoisomers and the relation to the absolute configuration are also discussed.  相似文献   

3.
The availability of a variety of stable organic stationary phases for columns has been a key factor in the development of HPLC as a major scientific tool. This paper explores the history and rationale used in the development of some important stationary phases and attempts to identify some of the strengths and limitations of these materials. Some of the author's experiences in stationary phase development illustrate approaches leading to present-day columns that exhibit a broad range of selectivity coupled with a high degree of reproducibility. Suggestions also are made for additional stationary phases that may be needed to complete column selectivity potential for HPLC separations.  相似文献   

4.
Recent developments of polysaccharide-based chiral stationary phases (CSPs) for the direct separation of enantiomers in high-performance liquid chromatography (HPLC) are mainly reviewed together with the results on mechanistic studies by means of chromatography, NMR and mass spectroscopies, and computational methods. Miscellaneous applications of polysaccharide derivatives to the newly developed, chiral dynamic high-performance liquid chromatography (DHPLC) for obtaining a nonracemic compound are also described.  相似文献   

5.
Several C18 stationary phases were found to behave non-ideally when insulins and proinsulins were eluted with shallow acetonitrile gradients in 0.1% trifluoroacetic acid, resulting in poor peak shapes or no elution at all. With triethylammonium phosphate or ammonium sulphate as buffer components, the insulins and proinsulins were eluted with excellent peak shapes, presumably owing to better masking of residual silanol groups on the stationary phases. Similar use of trifluoroacetic acid-acetonitrile gradients on the less hydrophobic C4 or C3 stationary phases resulted in excellent peak shapes. The difficult separation of rat proinsulin I and II, which are important for the study of rat insulin biosynthesis, was only achieved with two different stationary-mobile phase combinations.  相似文献   

6.
This paper focuses on the classification or differentiation of RP-HPLC columns based on measured chromatographic properties. A chemometric study has been conducted on a published data set consisting of 85 RP-HPLC columns and on a data set consisting of 47 self-tested columns. Principal component analysis enables determination of the number of parameters necessary for a rational differentiation. The results show that reducing the number of parameters for such differentiation still allows classification of the columns just as a higher number did. It is shown that three test parameters produce a classification similar to that obtained with five parameters.  相似文献   

7.
Takeuchi  T.  Hu  R.  Miwa  T. 《Chromatographia》1994,39(9-10):597-601
Chromatographia - The retention behavior of aromatic hydrocarbons on anion-exchangers modified with alkylsulfate or alkanesulfonate has been examined by column liquid chromatography. Several...  相似文献   

8.
Double alkylated L-glutamide-derived noncrystalline stationary phases Sil-DSG and Sil-DBG have been prepared by coupling N',N'-dioctadecyl-N-[4-carboxybutanoyl]-L-glutamide (DSG) and N',N',-dibutyl-N-[4-carboxybutanoyl]-L-glutamide (DBG) with aminopropylated silica (Sil-APS). TEM observations of DSG and DBG showed that lipid DSG can aggregate in organic solvents (methanol, chloroform, toluene, etc.) and self-assembled nano fibers are observed while such fibrous aggregations are not observed for DBG. The resulting chromatographic data have been provided information about its selective interaction with guest molecules (PAHs) in RP-HPLC. We have observed that the carbonyl groups in Sil-DSG exist in ordered state by forming a condensing thin layer over silica surface while DBG cannot form such an ordered state due to its lower order of short alkyl chain. The ordered carbonyl groups present in Sil-DSG promotes multiple carbonyl pi-benzene pi interactions with guest PAHs isomers which enhance the selectivity for these compounds. The contribution of pi-pi interactions was also supported by the substantial effects on the selectivity of benzene and nitrobenzenes. The effect of pi-electron containing solvent on the retention behavior of the PAHs was also studied. The selectivity for nucleic acid constituents, i.e. nucleosides and its bases were also evaluated by Sil-DSG and the selectivity for these compounds on Sil-DSG was compared with the selectivity of conventional polymeric ODS phase. It has been found that Sil-DSG provided higher selectivity for nucleic acid constituents than polymeric ODS and that HPLC packing materials can be efficiently employed for routine analysis of these compounds. The effect of methanol content on the separation behavior of nucleosides was also studied.  相似文献   

9.
Because of the problems caused by the irreversible binding of insulins and proinsulins to several silica-based reversed-phase columns, the use of polymeric reversed-phase columns was investigated for the analysis of rat islet polypeptides involved in insulin biosynthesis. No irreversible binding of insulins and proinsulins was observed for the polymeric reversed-phase columns, probably due to the absence of silanol groups. The six polypeptides involved in insulin biosynthesis in rat islets were equally well resolved in shallow trifluoroacetic acid-acetonitrile gradients on the silica-based Nucleosil 300-5C4 column (45 degrees C), the polymer-based Asahipak C4P-50 (25 and 45 degrees C), and ODP-50 columns (45 degrees C). In shallow triethylammonium phosphate-acetonitrile gradients (25 degrees C) satisfactory resolution of the two rat proinsulins was only obtained on the polymer-based Asahipak C4P-50 and C8P-50 columns. Increasing the separation temperature to 45 degrees C improved the separation of the two insulins and the two proinsulins in all cases. The shifts in retention times for the individual islet polypeptides observed in relation to the increased separation temperature were found to be different for the silica C4 and the polymer C4 columns. Recoveries of rat islet polypeptides were comparably high from the silica- and the polymer-based C4 columns and linear load-response curves were obtained in the microgram to picogram mass range on both columns.  相似文献   

10.
A study on the retention of PAHs on three Propyl-phenyl stationary phases was conducted, assessing absolute retention, selectivity, retention correlation and thermodynamic behaviour. The chromatographic retention data revealed that each of the three Propyl-phenyl columns exhibited differences in absolute retention, however, comparison of the compensation temperatures derived from enthalpy-entropy compensation plots showed that the underlying processes responsible for the retention on these columns were the same.  相似文献   

11.
A chemically bonded phase with a peptide group (PB) for reversed-phase high-performance liquid chromatography (HPLC) is described. This packing was prepared by a two-stage modification of the surface of silica gel with mono- and trifunctional 3-aminopropylsilane and then with an appropriate derivative of a fatty acid. Packings prepared in this way were compared with standard C18 materials used in HPLC. Surface characteristics of the packings before and after chemical modification were determined by different physico-chemical methods, e.g., porosimetry, elemental analysis, 13C and 29Si cross-polarization magic angle spinning NMR and HPLC. Chromatographic properties of these packings were evaluated by comparison between log k' of one phase and log k' of a second phase for substances with different chemical natures. The PB packing was found to be especially useful for the separation of basic substances.  相似文献   

12.
13.
Three poly(ethylene-co-acrylic) acid copolymers (–CH2CH2–)x[CH2CH(CO2H)–]y with different chain lengths and mass fractions of acrylic acid were covalently immobilized as stationary phases on silica via two variants of spacer molecules (3-aminopropyltriethoxysilane and 3-glycidoxypropyltrimethoxysilane). Different mobilities of the alkyl chains in the stationary phases were observed using 13C solid-state NMR spectroscopy. The stationary phases with more rigid trans-ordered alkyl chains had better selectivity for geometric -carotene and xanthophyll isomers (provitamin A derivatives). Also, all the separations of the analytes were affected by polar interactions with the chromatographic sorbent. This was further proved by separating more polar cis/trans retinoic acid isomers (vitamin A derivatives). 13C high-resolution/magic-angle spinning (HR/MAS) NMR measurements of the chromatographic sorbents suspended in the mobile phase confirmed a dependence of molecular shape recognition ability on alkyl chain conformation.  相似文献   

14.
The solvation parameter model system constants and retention factors were used to interpret retention properties of 39 calibration compounds on a biphenylsiloxane-bonded stationary phase (Kinetex biphenyl) for acetone-water binary mobile phase systems containing 30–70% v/v. Variation in system constants, phase ratios, and retention factors of acetone-water binary mobile phases systems were compared with more commonly used acetonitrile and methanol mobile phase systems. Retention properties of acetone mobile phases on a Kinetex biphenyl column were more similar to that of acetonitrile than methanol mobile phases except with respect to selectivity equivalency. Importantly, selectivity differences arising between acetone and acetonitrile systems (the lower hydrogen-bond basicity of acetone-water mobile phases and differences in hydrogen-bond acidity, cavity formation and dispersion interactions) could be exploited in reversed-phase liquid chromatography method development on a Kinetex biphenyl stationary phase.  相似文献   

15.
In this paper the pulse thermovision (photothermal) detection and quantification methods of C60 and C70 fullerenes are presented. Quantification results are compared with optical and fluorescence measurements. Target components were separated under isothermal conditions (30 °C) on micro-TLC plates (RP18WF254S) using n-hexane as the mobile phase. The principle of described analytical protocol is based on sensitive measurement of the temperature contrast generated within TLC stationary phase and fullerenes spots after white light pulse excitation. It has been demonstrated that observed temperature contrast is mainly driven by the optical properties of fullerenes (UV–vis absorption spectra). Contrary to the commonly applied optical reflection or transmission techniques the proposed thermovision method involves dissipated light. The results of presented experimental work have revealed that both types of quantitative measurements provide similar outcome despite the key differences in the signal origin. However, it has been found that thermovision method was characterized by smaller value of LOD, particularly for C60 molecule. We demonstrated that application of correlation technique to post-acquisition analysis of the sequence of temperature contrast images significantly increase detection limits of fullerenes, even in comparison to fluorescence quenching detection mode. Moreover, the thermal contrast images and particularly, computed correlation image, allow detection of stationary phase layer nonuniformities, including changes in the adsorbent thickness and thermal conductivity. Therefore, invented pulsed thermovision methodology can be additionally used for fast quality screening of home made and commercially available TLC plates.  相似文献   

16.
The retention behavior of aromatic hydrocarbons and dansylamino acids on cation-exchangers modified with alkylammonium ions has been examined by microcolumn liquid chromatography. Several parameters affected the retention of analytes, involving concentration of the modifier in the mobile phase, its alkyl chain length and mobile phase composition. Stationary phases modified with a reagent having longer alkyl chains achieved better column efficiency.  相似文献   

17.
Batches of poly(methyloctylsiloxane) (PMOS)-loaded silica were prepared by deposition from a solution of PMOS into the pores of HPLC silica. Portions of PMOS-loaded silica were subjected to a thermal treatment at 100 degrees C for 24h (condition 1) in a tube furnace under a nitrogen atmosphere. After that, the material was heated for 4h at higher temperatures (150-400 degrees C) (condition 2). Heating at higher temperatures produces polymer bilayers. Non-immobilized and thermally treated stationary phases were characterized by percent carbon, (29)Si cross-polarization magic angle spinning nuclear magnetic resonance spectroscopy and reversed-phase chromatographic performance. The results show that thermal treatment between 150 and 300 degrees C accelerates the immobilization process, possibly due to some bond breaking of the polysiloxane, with formation of strong linkages to the surface of the support, resulting in more complete coverage of the silica. The chromatographic results show an improvement of efficiency with the increase of the temperature of condition 2 up to 300 degrees C and an increase in the resolution of the components, mainly for the phase heated at 300 degrees C. Such results demonstrate that a two-step thermal treatment (100 degrees C then 150-300 degrees C) produces stationary phases with good properties for use in reversed-phase high-performance liquid chromatography.  相似文献   

18.
Summary Silica beads of 6-μm average diameter were silanized with methylvinyldiethoxysilane and then subjected to encapsulation with poly(methylvinylsiloxane). The resulting product is a new stationary phase for reversed-phase high performance liquid chromatography (RP-HPLC) which has superior ability for the separation of polar, non-polar and basic compounds. The chromatographic peaks are symmetric. Its stability has been studied; after continuous use for three months the carbon content and chromatographic behaviour of the phase were unchanged. on to the silica surface to given an uniform organic film. Material prepared in this way has both good chromatographic behaviour and superior selectivity. Because contact of the silica matrix with the mobile phase is avoided, the alkali-resisting ability of the stationary phase is increased. The non-specific adsorption of alkaline solutes on to the silica surface is also avoided because of the complete coverage of surface silanol groups. Reports of stationary phases encapsulated with polystyrene [6], polybutadiene [I] and octadecylsiloxane polymers have recently appeared in the literature [3]. In this paper we report the encapsulation of poly-(methylvinylsiloxane) (analogous to the phase SE-31 often used in GC) on to a silica matrix previously modified with methylvinyldiethoxysilane. The resulting phase has superior performance in reversed-phase HPLC.  相似文献   

19.
This paper describes the enantiomeric resolution of a series of unsaturated N-methyloxycarbonyl-alpha-H-alpha-amino acids (N-MOC-alpha-amino acids) on macrocyclic glycopeptide stationary phases by means of high-performance liquid chromatography (HPLC). Three types of glycopeptide phases, i.e. Chirobiotic T, V and R, were evaluated in both reversed-phase (RP) and polar ionic mode (PIM). The best results in terms of enantioselectivity and resolution were obtained on Chirobiotic R phase, with the PIM mobile phase giving the highest resolution per min. Investigation of the pH of the reversed-phase mobile phase in the pH range 4.1-5.9 showed little effect on enantioselectivity. The method was applied for monitoring the conversion and product enantiomeric excess of an enzymatic hydrolysis reaction using N-MOC-alpha-H-alpha-amino acid esters as substrate.  相似文献   

20.
Pyrolysis coupled with gas chromatography and or mass spectrometry, allows the identification of the bonded chain in reversed-phase high-performance liquid chromatographic stationary phases. It is possible to distinguish whether an octadecylated reversed-phase was prepared with a trifunctional(e.g., trichloro or monofunctional dimethyl, e.g., dimethyl-ethoxy) octadecylsilane from the relative heights of the heptadecene and octadecene peaks. The nature of the pyrolysis products was investigated. No carbon chains are formed with more carbon atoms than in the bonded chain. The peak area ratio of methane to that of the combined C4 products allows one to deduce whether the reversed-phase was deactivated as not by reaction with a trimethylsilylating reagent (end-capping).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号