首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Modified Pencil Lead as a New Fiber for Solid-Phase Microextraction   总被引:2,自引:0,他引:2  
Dj. Djozan  Y. Assadi 《Chromatographia》2004,60(5-6):313-317
The efficiency of modified pencil lead as a new fiber for solid-phase microextraction (SPME) has been investigated. Modified pencil lead fibers have been prepared by use of several activation processes, for example heating at 600 °C in the stream of inert gas (He), heating under reflux with concentrated H2SO4 , fusing with NaOH at 400 °C, and activation at 600 °C with water vapor for 60 min. The fibers were used for extraction of trace amounts of polycyclic aromatic hydrocarbons (PAH) from aqueous samples. Monitoring of extracted compounds and quantitative analysis of model samples were performed by capillary GC–FID. The results obtained prove the suitability of the proposed fibers for sampling organic compounds from water. Effects on extraction efficiency of factors such as temperature, salting out, stirring speed, and exposure time were studied. Under optimum conditions and using one fiber for extraction of naphthalene as a typical compound, a relative standard deviation of 5.3% (n=7) was achieved. The calibration plot was linear in the range 50–10,000 pg mL–1 (r=0.9997) and the detection limit was 25 pg mL–1 (S/N=3). This fiber is very stable at high temperature, inexpensive, and can be prepared simply.  相似文献   

2.
This work is a first study on extraction efficiency and thermal stability of nano-structured self-doped polyaniline (SPAN) as a coating of solid-phase microextraction (SPME) fibers. SPAN-based fibers were prepared using electrochemical deposition on platinum wires. The particle sizes of prepared nano-structure were in the range of 50–100 nm. Extraction properties of the fiber to 1,4-dioxane were examined using headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-flame ionization detection (GC-FID). The results have proved higher thermal stability of the proposed fiber compared to common PANI fiber. The SPAN coating was proved to be very stable at relatively high temperatures (up to 350 °C) with high extraction capacity and long lifespan (more than 50 times). Therefore, it can be a good substitute of polyaniline (PANI) as a SPME coating. The extraction procedure was optimized by selecting the appropriate extraction parameters including extraction time, extraction temperature, salt concentration, stirring rate and headspace volume. Calibration graph was linear in the concentration range of 1–100 ng mL−1 (R2 > 0.993) with detection limit of 0.1 ng mL−1. Single fiber and fiber-to-fiber repeatability were lower than 6.0% and 10.4%, respectively. Different water samples were analyzed as real samples and good recoveries (98–120%) were obtained.  相似文献   

3.
The surface of a stainless steel fiber was made larger, porous and cohesive by platinizing for tight attachment of its coating. Then it was coated by a polyaniline/polypyrrole/graphene oxide (PANI/PP/GO) nanocomposite film using electrochemical polymerization. The prepared PANI/PP/GO fiber was used for headspace solid‐phase microextraction (HS‐SPME) of linear aliphatic aldehydes in rice samples followed by GC‐FID determination. To achieve the highest extraction efficiency, various experimental parameters including extraction time and temperature, matrix modifier and desorption condition were studied. The linear calibration curves were obtained over the range of 0.05–20 μg g−1 (R 2 > 0.99) for C4–C11 aldehydes. The limits of detection were found to be in the range of 0.01–0.04 μg g−1. RSD values were calculated to be <7.4 and 10.7% for intra‐ and inter‐day, respectively. The superiority of the prepared nanocomposite SPME fiber was established by comparison of its results with those obtained by polydimethylsiloxane, carbowax–divinylbenzene, divinylbenzene–carboxen–polydimethylsiloxane and polyacrylate commercial ones. Finally, the nanocomposite fiber was used to extract and determine linear aliphatic aldehydes in 18 rice samples.  相似文献   

4.
Gel filtration chromatography using a TSKgel G2000 SW column coupled with differential refractive index detection was used to analyse five grades of polyvinyl alcohol. Limits of detection and quantification for the assay were 0.14 mg mL–1, 0.47 mg mL–1 respectively. The inter and intra-day co-efficient of variance were both <7%. There was a significant difference (p<0.05, n=5) between the calibration curves across the five grades of PVA due to a refractive index range of 13.0790 –1.3181 (n=3). The assay accuracy was 98.99% ± 8.97% (n=5) and 90.60% ± 7.87% (n=5) of a spiked PVA sample was recovered from a commercial formulation.  相似文献   

5.
Gold wire was coated with polypyrrole (PPY) by electropolymerization and used as a solid-phase microextraction (SPME) fiber. The adsorptive property of the coating was modified by doping with tetrasulfonated nickel phthalocyanine (NiPcTS). The efficiency and reliability of this fiber was investigated for the extraction of BTEX compounds from the headspace of water samples. Monitoring of extraction efficiency was performed by capillary GC-FID. Effects of several factors such as electropolymerization time, salt addition, exposure time and stirring speed on extraction efficiency were studied. The calibration graphs were linear in the range of 0.06 to 50 ng mL?1 and the detection limits for BTEX compounds were 20–50 pg mL?1. Comparing the results obtained using these fibers with results reported in the literature with polydimethylsiloxane (PDMS) fibers shows that under optimum conditions, the detection limits are comparable.  相似文献   

6.
Nanofibrous polyaniline–magnetite (PANI/Fe3O4) nanocomposite was in situ prepared through adsorption of magnetite nanoparticles onto PANI nanofibers surface and utilized as an efficient sorbent for magnetic solid-phase extraction of naproxen from water and biological samples, followed a desorption step and spectrofluorimetric determination. Field-emission scanning electron microscopy, transmission electron microscopy, Fourier-transform infrared spectroscopy, thermal gravimetric analysis and X-ray diffraction techniques were employed for characterization of the prepared nanocomposite. The important parameters influencing the extraction efficiency including PANI/Fe3O4 mass ratio, adsorbent dose, extraction time, sample solution pH, ionic strength, type and volume of desorption solvent and the elution time were studied and optimized. The investigated nanocomposite was successfully applied to the extraction of naproxen in spiked tap water, urine and plasma samples, with a relative recovery in the range of 90–98%. The reusability of PANI/Fe3O4 was examined for ten successive cycles, and the results confirm that the efficiency did not change significantly. A linear calibration plot was obtained in the range of 40–1000 ng mL?1 with a limit of detection about 17 ng mL?1 under the optimum conditions. The relative standard deviation (RSD) was found to be 2.34% (n = 8, concentration level of 100 ng mL?1). The kinetics and thermodynamics of the extraction process were also studied.  相似文献   

7.
Specific polyclonal-based immunoassays for sulfathiazole   总被引:4,自引:0,他引:4  
A highly sensitive and specific enzyme-linked immunosorbent assay has been developed for detection of sulfathiazole (STZ, 4-amino-N-thiazol-2-yl-benzenesulfonamide). A set of haptens was synthesized in order to produce polyclonal antibodies against sulfonamides. Two ELISA formats (antibody-coated and conjugate-coated) were also investigated using all the serum/coating conjugate combinations that showed specific recognition. The developed ELISA succeeded in detection of STZ at concentrations as low as 0.03 ng mL–1 over a measurable range of 0.12–6.71 ng mL–1. Selectivity studies have demonstrated that other sulfonamides do not interfere significantly (<10%) with analysis of STZ by this immunochemical technique. Analysis of spiked bee honey samples by the developed ELISA method showed recoveries were good. The selectivity and sensitivity (IC50=1.6 ng mL–1) make it a suitable screening method for determination of low levels of STZ in food samples.  相似文献   

8.
《Analytical letters》2012,45(9):1442-1453
A novel method to preconcentrate gold was developed employing a synergistic enhancement of a room temperature ionic liquid combined with hollow fiber liquid phase micro-extraction with flame atomic absorption spectrometry detection. The method is based on the complexation of gold with dithizone. The formed hydrophobic complex was subsequently extracted into the lumen of a hollow fiber. The organic phase was siphoned into FAAS for the determination. A room temperature ionic liquid and dithizone were used the enhancement reagent and chelating reagent, respectively. The addition of a room temperature ionic liquid led to a five-fold improvement in the extraction of gold. The 1-octanol was immobilized in the pores of the polypropylene hollow fiber as the liquid membrane and was also used as the acceptor solution. Some parameters that influenced extraction and determination were evaluated in detail, such as concentrations of the ionic liquid and dithizone, pH of samples, stirring rates, extraction time, and interferences. Under optimized conditions, a detection limit of 0.9 ng mL?1 and an enrichment factor of 130 were achieved. The relative standard deviation (RSD) was 3.7% for Au (40 ng mL?1, n = 5). The proposed method was successfully applied to the determination of gold in certified reference environmental samples and ore samples with satisfactory results.  相似文献   

9.
Procedures were developed for the determination of some organic compounds (n-alkanes, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, Cl,P,N-pesticides, phthalic acid esters, chlorophenols, aliphatic acids, and methyl esters of aliphatic acids) in water on the basis of direct supercritical fluid extraction with the subsequent gas-chromatographic analysis of the entire extract without using organic solvents. The detection limits were 10–11–10–7% depending on the nature of the analyte.  相似文献   

10.
Summary Phencyclidine (PCP) was found to be extractable by headspace solid-phase microextraction (SPME) from human whole blood and urine. Sample solutions were heated at 90°C in the presence of NaOH and K2CO3, and an SPME fiber was exposed in the headspace of a vial for 30 min. Immediately after withdrawal of the fiber, it was analyzed by gas chromatography with surface ionization detection (GC-SID). Recoveries of PCP were approximately 9.3–10.8% and 39.8–47.8% for whole blood and urine samples, respectively. The calibration curve for PCP showed good linearity in the range 2.5–100 ng mL–1 whole blood and 0.5–100 ng mL–1 urine. The detection limits were approximately 1.0 ng mL–1 for whole blood and 0.25 ng mL–1 for urine.  相似文献   

11.
A new fiber based on titania‐chitin sol‐gel coated on a silver wire for the headspace solid phase microextraction of aliphatic alcohols from apple juice samples was developed. The influences of fiber coating composition and microextraction conditions (extraction temperature, extraction time, and ionic strength of the sample matrix) on the fiber performance were investigated. Also, the influence of temperature and time on desorption of analytes from fiber were studied. Under the optimized conditions, a porous fiber with a high extraction capacity and good thermal stability (up to 250°C) was obtained. The proposed headspace solid‐phase microextraction‐GC method was successfully used for the analysis of aliphatic alcohols in apple juice and concentrate samples. The recovery values were from 92.8 to 98.6%. The RSD (n=5) for all analytes were below 7.8%.  相似文献   

12.
A recently synthesized polyaniline (PANI) has been used and evaluated as a sorbent for solid-phase extraction of a variety of polar pesticides and some of their degradation products from water samples. Several classes of pesticides including phenoxy acids, triazines, ureas, oxime carbamates and carbamates were selected for this study. The determination of these pesticides was carried out using cyclodextrin modified micellar electrokinetic chromatography equipped with diode array detection. The recovery results using PANI were compared with those obtained by C18, Isolute ENV+, Oasis HLB and LiChrolut EN. Effect of humic acid, as a major interference, on extraction recovery was also studied. The performance of the method was evaluated by analysis of tap and river water. The RSD of method was between 6 and 14% (n=3) and detection limits were in the range of 0.01–0.5 g L–1 using 350-mL water samples.  相似文献   

13.
A new micelle-mediated cloud point extraction method is described for sensitive and selective determination of trace amounts of rhodamine B by spectrophotometry. The method is based on the cloud point extraction of rhodamine B from aqueous solution using Triton X-100 in acidic media. The extracted surfactant rich phase is diluted with water and its absorbance is measured at 563 nm by a spectophotometer. The effects of different operating parameters such as concentration of surfactant and salt, temperature and pH on the cloud point extraction of rhodamine B were studied in details and a set of optimum conditions were obtained. Under optimum conditions a linear calibration graph in the range of 5-550 ng mL−1 of rhodamine B in the initial solution with r = 0.9991 (n = 15) was obtained. Detection limit based on three times the standard deviation of the blank (3Sb) was 1.3 ng mL−1 (n = 10) and the relative standard deviation (R.S.D.) for 50 and 350 ng mL−1 of rhodamine B was 2.40 and 0.87% (n = 10), respectively. The method was applied for the determination of rhodamine B in soft pastel, hand washing liquid soap, matches tip and textile dyes mixture samples.  相似文献   

14.
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes (MWCNTs)/Nafion was developed and applied for the extraction of polar aromatic compounds (PACs) in natural water samples. The characteristics and the application of this fiber were investigated. Electron microscope photographs indicated that the MWCNTs/Nafion coating with average thickness of 12.5 μm was homogeneous and porous. The MWCNTs/Nafion coated fiber exhibited higher extraction efficiency towards polar aromatic compounds compared to an 85 μm commercial PA fiber. SPME experimental conditions, such as fiber coating, extraction time, stirring rate, desorption temperature and desorption time, were optimized in order to improve the extraction efficiency. The calibration curves were linear from 0.01 to 10 μg mL−1 for five PACs studied except p-nitroaniline (from 0.005 to 10 μg mL−1) and m-cresol (from 0.001 to 10 μg mL−1), and detection limits were within the range of 0.03–0.57 ng mL−1. Single fiber and fiber-to-fiber reproducibility were less than 7.5 (n = 7) and 10.0% (n = 5), respectively. The recovery of the PACs spiked in natural water samples at 1 μg mL−1 ranged from 83.3 to 106.0%.  相似文献   

15.
The biopolymer emulsan, which forms stable emulsions with mixtures of aliphatic and cyclic (or aromatic) hydrocarbons in water, does not emulsify aliphatic hydrocarbons alone [1–4]. Monohydric primary alcohols from hexanol to dodecanol were shown to enhance the formation of pure aliphatic hydrocarbon/water emulsions under conditions of mild agitation. Enhancement was a function of emulsan concentration and was proportional to alkanol concentration (5×10–5 M to 2.5x10–4 M) at constant bioemulsifier concentration (0.05 mg/ml). Enhancement of emulsification was also found when aqueous solutions of diethanolamine and phenethyl alcohol (5 to 30×10–3 M) were substituted for the primary alcohols. None of these substances emulsified hexadecane or othern-alkanes in the absence of the biopolymer. The strongest enhancement of emulsification (3-fold) was observed with tetra- and hexadecane. At alkanol concentrations optimal for enhancement of emulsification, no significant lowering of hexadecane/ emulsan/water interfacial tension was observed. The possibility of a direct association of alkanols with the emulsan in solution, resulting in altered conformation of biopolymer and modification of its specificity toward hydrocarbons, is discussed.Preliminary results of this work were presented at the 57th Colloid and Surface Science Symposium, 1983, Toronto, Canada.  相似文献   

16.
A novel and highly sensitive chemiluminescence (CL) method for the determination of terbutaline sulfate, coupled with flow-injection analysis (FIA), is described in this paper. The method is based on enhancement by terbutaline sulfate of the chemiluminescence emission of the luminol–permanganate system under alkaline conditions. Under the conditions selected the concentration of terbutaline sulfate is proportional to CL intensity in the range 5×10–10–5×10–7 g mL–1, with a detection limit of 1.7×10–10 g mL–1 (3). The relative standard deviation is 2.8% for 1×10–8 g mL–1 terbutaline sulfate (n=11). Ninety samples can be determined per hour. The proposed method has been used to determine terbutaline sulfate in pharmaceutical preparations and in plasma and urine samples with satisfactory results. The possible mechanism of the chemiluminescence reaction is discussed briefly.  相似文献   

17.
In the medium HCl–KI–rhodamine dye, NO2 reacts with excess I to form I3 and the I3 and rhodamine dye combine to form an association particle which gives three resonance-scattering (RS) peaks at 320 nm, 400 nm, and 595 nm. In systems containing rhodamine 6G (Rh6G), rhodamine B (RhB), rhodamine S (RhS), and butyl rhodamine B (BRhB) the resonance scattering intensity at 400 nm is proportional to nitrite concentrations in the range 2.3–276 ng mL–1, 9.2–184 ng mL–1, 9.2–184 ng mL–1, and 9.2–92 ng mL–1, respectively. Because of the high sensitivity, wide linear range, and good stability of the Rh6G system, it has been used for determination of nitrite in water samples, with satisfactory results. The spectral results have been used to verify that the formation of (Rh6G·I3)n association particles and their interface with the system are main factors that cause the RS enhancement.  相似文献   

18.
A method based on cloud point extraction and graphite furnace atomic absorption spectrometry (GFAAS) was developed for the analysis of trace tin in water samples. After cloud point extraction, the tin in the water samples was preconcentrated and successfully separated from most interferents. During the procedure, 8-hydroxyquinoline (8-HQ) was used as chelating reagent, and Triton X-114 was added as surfactant. The parameters affecting the sensitivity and the extraction efficiency, such as solution pH, concentration of 8-HQ and Triton X-114, equilibration temperature and centrifuge time, were evaluated and optimized. Under the optimum conditions, a preconcentration factor of 96.2 was obtained for a 20 mL water sample. The detection limit (LOD) was as low as 0.012 ng mL−1, and the analytical curve was linear in the range of 0.05–2.0 ng mL−1 with satisfactory precision (RSD <4.1%). The proposed method was successfully applied to the determination of trace tin in water samples with recoveries in the range of 85.0–112.0%.  相似文献   

19.
A simple and efficient liquid-phase microextraction (LPME) technique was developed using directly suspended organic microdrop coupled with gas chromatography–mass spectrometry (GC–MS), for the extraction and the determination of phthalate esters (dimethyl phthalate, diethyl phthalate, diallyl phthalate, di-n-butyl phthalate (DnBP), benzyl butyl phthalate (BBP), dicyclohexyl phthalate and di-2-ethylhexyl phthalate (DEHP)) in water samples. Microextraction efficiency factors, such as nature and volume of the organic solvent, temperature, salt effect, stirring rate and the extraction time were investigated and optimized. Under the optimized extraction conditions (extraction solvent: 1-dodecanol; extraction temperature: 60 °C; microdrop volume: 7 μL; stirring rate: 750 rpm, without salt addition and extraction time: 25 min), figures of merit of the proposed method were evaluated. The values of the detection limit were in the range of 0.02–0.05 μg L−1, while the R.S.D.% value for the analysis of 5.0 μg L−1 of the analytes was below 7.7% (n = 4). A good linearity (r2 ≥ 0.9940) and a broad linear range (0.05–100 μg L−1) were obtained. The method exhibited enrichment factor values ranging from 307 to 412. Finally, the designed method was successfully applied for the preconcentration and determination of the studied phthalate esters in different real water samples and satisfactory results were attained.  相似文献   

20.
In the present work the determination of benzene, toluene, ethylbenzene and o-xylene (BTEX) in environmental sample solutions using gas chromatography with flame ionisation detection (GC-FID) combined with three different sampling techniques, such as; direct single drop microextraction (DI-SDME), headspace single drop microextraction (HS-SDME) and ultrasonic assisted HS-SDME, were compared. In all of these techniques, for the determination of BTEX, the experimental parameters such as organic solvent effect, extraction time, agitation speed and salting effect were optimised. At their optimised conditions of operation the detection limits, times of extraction and precision for the three techniques are established. A detailed comparison of the analytical performance characteristics of these techniques for final GC-FID determination of BTEX in water samples was given. The technique provided a linear range of 50–20000?ng?mL–1 for DI-SDME and 10–20000?ng?mL–1 for HS-SDME methods, good repeatability (RSDs <4.72–7.74% for DI-SDME and 1.80–7.05% for HS-SDME (n?=?5), good linearity (r?≥?0.9978) and limits of detection (LODs) in the range of 0.006–10?ng?mL?1 for DI-SDME, 0.1–3?ng?mL–1 for HS-SDME methods (S/N?=?3). Then the optimised techniques were also applied to real samples (river and waste waters) containing BTEX and similar precision (RSD?<?8.2,?n?=?3) was obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号