首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This review covers recent advances of capillary electrophoresis (CE) in pharmaceutical analysis. The principle, instrumentation, and conventional modes of CE are briefly discussed. Advances in the different CE techniques (non-aqueous CE, microemulsion electrokinetic chromatography, capillary isotachophoresis, capillary electrochromatography, and immunoaffinity CE), detection techniques (mass spectrometry, light-emitting diode, fluorescence, chemiluminescence, and contactless conductivity), on-line sample pretreatment (flow injection) and chiral separation are described. Applications of CE to assay of active pharmaceutical ingredients (APIs), drug impurity testing, chiral drug separation, and determination of APIs in biological fluids published from 2008 to 2009 are tabulated.  相似文献   

2.
The present study reports the investigation of capillary electrophoresis (CE) for the separation of the photosynthetic pigments (chlorophyll derivatives as well as carotenoids) together. Various CE methods, such as micellar electrokinetic chromatography, capillary electrokinetic chromatography, and nonaqueous capillary electrophoresis (NACE) are tested, with coated and uncoated capillary columns to evaluate optimal separation conditions using diode array detection. The effect of different type and composition of organic solvents and surfactants on the separation is discussed. Detection limits are found in the range of 1.14-2.45 ppm. According to the system suitability results, the most effective separation is observed using NACE with Aliquat 336 as cationic surfactant in coated capillary and mixture of MeOH-ACN-THF (5:4:1, v/v/v) as solvent. Quantitative evolution is investigated, and recovery percentage values are found to be 96.7-102%.  相似文献   

3.
Determination of tea catechins   总被引:5,自引:0,他引:5  
An overview of analytical methods for the measurement of biologically important tea catechins is presented. Liquid chromatography and capillary electrophoresis are the most cited techniques for catechin separation, identification and quantitation. Liquid chromatography with ultraviolet detection is frequently used; however, mass spectrometry, electrochemical, fluorescence and chemiluminescence detection are also utilized in cases where more sensitive or selective detection is needed. Two modes of capillary electrophoresis, capillary zone electrophoresis and micellar electrokinetic capillary chromatography, have been employed for the determination of catechins. Both modes of capillary electrophoresis are based on ultraviolet detection. Additional analytical techniques, such as gas chromatography, thin-layer chromatography, paper chromatography, spectrophotometry, biosensing, chemiluminescence and nuclear magnetic resonance spectroscopy have also been utilized for the determination of catechins and are reviewed herein.  相似文献   

4.
芯片毛细管电泳及其在生命科学中的应用   总被引:10,自引:0,他引:10  
王辉  林炳承 《分析化学》2002,30(3):359-364
芯片毛细管电泳 (Chip CE)技术在近几年已取得了很大的进展。本文着重介绍芯片毛细管区带电泳技术 ,对等电聚焦、等速电泳、自由溶液电泳及胶束电动色谱等其它芯片电泳模式也有所提及。讨论了芯片材料和制作技术、芯片的几何形状、样品的操作和衍生、检测及芯片毛细管电泳技术的应用 ,特别是在核酸和蛋白质的分离分析中的进展  相似文献   

5.
Capillary electrophoresis represents a promising technique in the field of pharmaceutical analysis. The presented review provides a summary of capillary electrophoretic methods suitable for routine quality control analyses of small molecule drugs published since 2015. In total, more than 80 discussed methods are sorted into three main sections according to the applied electroseparation modes (capillary zone electrophoresis, electrokinetic chromatography, and micellar, microemulsion, and liposome-electrokinetic chromatography) and further subsections according to the applied detection techniques (UV, capacitively coupled contactless conductivity detection, and mass spectrometry). Key parameters of the procedures are summarized in four concise tables. The presented applications cover analyses of active pharmaceutical ingredients and their related substances such as degradation products or enantiomeric impurities. The contribution of reported results to the current knowledge of separation science and general aspects of the practical applications of capillary electrophoretic methods are also discussed.  相似文献   

6.
The migration behaviour of isoquinoline, quinoline, and methyl derivatives of quinoline in different capillary electrophoretic modes has been systematically investigated. Optimised separation conditions were established by varying the key parameters (solvent, pH, temperature, surfactant concentration, core phase) for aqueous and non‐aqueous capillary zone electrophoresis (NACE), micellar electrokinetic chromatography (MEKC) with anionic or non‐ionic micelles (SDS, Brij 35), and microemulsion electrokinetic chromatography (MEEKC) with charged or uncharged microemulsion droplets. A separation of all quinolines could be achieved by MEEKC with charged droplets, by MEKC or by formamide‐based NACE. Comparing the separations with respect to separation selectivity, substantial changes in migration order could be observed between the different techniques. Regarding separation efficiency, the number of theoretical plates and limits of detection (LOD) have been compared. The best LODs were achieved using SDS as surfactant in MEKC, followed by MEEKC.  相似文献   

7.
Recent advances in capillary separations for proteomics   总被引:1,自引:0,他引:1  
Cooper JW  Wang Y  Lee CS 《Electrophoresis》2004,25(23-24):3913-3926
The sequencing of several organisms' genomes, including the human's one, has opened the way for the so-called postgenomic era, which is now routinely coined as "proteomics". The most basic task in proteomics remains the detection and identification of proteins from a biological sample, and the most traditional way to achieve this goal consists of protein separations performed by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE). Still, the 2-D PAGE-mass spectrometry (MS) approach remains lacking in proteome coverage (for proteins having extreme isoelectric points or molecular masses as well as for membrane proteins), dynamic range, sensitivity, and throughput. Consequently, considerable efforts have been devoted to the development of non-gel-based proteome separation technologies in an effort to alleviate the shortcomings in 2-D PAGE while reserving the ability to resolve complex protein and peptide mixtures prior to MS analysis. This review focuses on the most recent advances in capillary-based separation techniques, including capillary liquid chromatography, capillary electrophoresis, and capillary electrokinetic chromatography, and combinations of multiples of these mechanisms, along with the coupling of these techniques to MS. Developments in capillary separations capable of providing extremely high resolving power and selective analyte enrichment are particularly highlighted for their roles within the broader context of a state-of-the-art integrated proteome effort. Miniaturized and integrated multidimensional peptide/protein separations using microfluidics are further summarized for their potential applications in high-throughput protein profiling toward biomarker discovery and clinical diagnosis.  相似文献   

8.
Analysis of agrochemicals by capillary electrophoresis   总被引:1,自引:0,他引:1  
An increasing amount of articles using capillary electrophoresis as an investigation tool for pesticides and environmental pollutants were found over the last few years in analytical chemistry oriented journals. This review covers a wide literature range of the 1990s and concentrates on the analysis of organic agrochemicals (herbicides, fungicides, insecticides, acaricides, etc.) with capillary electrophoresis (capillary zone electrophoresis, micellar electrokinetic chromatography with CE-UV-visible or laser-induced fluorescence detection) as well as with the on-coming hyphenated techniques like capillary electrophoresis-electrospray ionization mass spectrometry. The principal preconcentration methods that allowed real sample analysis with CE are also briefly discussed. The pesticides, the separation methods, the used electrolytes, the detection types, the detection limits and the preconcentration methods were classified and presented in tabulated form as a rapid information tool.  相似文献   

9.
The review gives an update about the methodological and instrumental developments in micellar electrokinetic capillary chromatography as a type of CE analytical technique. Here, the last two years development of the technique are particularly presented. Recent approaches to improve sensitivity are discussed. Newly introduced concentration techniques and experimental methods for verification of the different mechanisms and processes of micellar electrokinetic chromatography analysis are highlighted. A theoretical model to explain changes in separation and electrophoretic mobility order of fully charged analytes are demonstrated. Modern approaches for improving compatibility of micellar electrokinetic capillary chromatography to mass spectrometry are also reported.  相似文献   

10.
Capillary electrophoresis on microchip   总被引:10,自引:0,他引:10  
Capillary electrophoresis and related techniques on microchips have made great strides in recent years. This review concentrates on progress in capillary zone electrophoresis, but also covers other capillary techniques such as isoelectric focusing, isotachophoresis, free flow electrophoresis, and micellar electrokinetic chromatography. The material and technologies used to prepare microchips, microchip designs, channel geometries, sample manipulation and derivatization, detection, and applications of capillary electrophoresis to microchips are discussed. The progress in separation of nucleic acids and proteins is particularly emphasized.  相似文献   

11.
This work reviews the literature of chiral capillary electrokinetic chromatography from January 2016 to March 2021. This is done to explore the state-of-the-art approach and recent developments carried out in this field. The separation principle of the technique is described and supported with simple graphical illustrations, showing migration under normal and reversed polarity modes of the separation voltage. The most relevant applications of the technique for enantioseparation of drugs and other enantiomeric molecules in different fields using chiral selectors in single, dual, or multiple systems are highlighted. Measures to improve the detection sensitivity of chiral capillary electrokinetic chromatography with UV detector are discussed, and the alternative aspects are explored, besides special emphases to hyphenation compatibility to mass spectrometry. Partial filling and counter migration techniques are described. Indirect identification of the separated enantiomers and the determination of enantiomeric migration order are mentioned. The application of Quality by Design principles to facilitate method development, optimization, and validation is presented. The elucidation and explanation of chiral recognition in molecular bases are discussed with special focus on the role of molecular modeling.  相似文献   

12.
Kist TB  Mandaji M 《Electrophoresis》2004,25(21-22):3492-3497
A large number of nanostructures have the potential to be used together with electrophoresis as separation media or separation additive in capillary electrophoresis, micellar electrokinetic chromatography, capillary electrochromatography, and other analytical techniques. Among those structures are nanotubes, nanocavities, nanowires, nanoposts, nanocones, nanospheres, molecular imprints, nanoparachutes (conical monodendrons), and general nanoparticles with random structures. This review is focused only on publications describing experimental works using molecular imprints, nanoposts, and nanospheres that are fabricated and applied for the purpose of separation media in electrophoresis-driven separations. The review follows an approximate chronological order in each section. As shown, the most popular are those resulting from molecular imprinting technologies. These biomimetic receptors are used in a great variety of fields, which includes electrophoresis, micellar electrokinetic chromatography, capillary electrochromatography, and other fields not reviewed in this work. A few examples of these other fields are, e.g., liquid chromatography, membranes, extractor or preconcentration techniques, immunosorbent assays, and sensing devices. The second topic scanned in the present work is the nanostructures that are used as obstacles to replace gels or polymers solutions in electrophoresis. Finally, the nascent field of nanospheres of gold and other materials as separation media is also reviewed.  相似文献   

13.
14.
This review gives a survey of selectivity modes in capillary electrophoresis separations in pharmaceutical analysis and bioanalysis. Despite the high efficiencies of these separation techniques, good selectivity is required to allow quantitation or identification of a particular analyte. Selectivity in capillary electrophoresis is defined and described for different separation mechanisms, which are divided into two major areas: (i) capillary zone electrophoresis and (ii) electrokinetic chromatography. The first area describes aqueous (with or without organic modifiers) and nonaqueous modes. The second area discusses all capillary electrophoretic separation modes in which interaction with a (pseudo)stationary phase results in a change in migration rate of the analytes. These can be divided in micellar electrokinetic chromatography and capillary electrochromatography. The latter category can range from fully packed capillaries, via open-tubular coated capillaries to the addition of microparticles with multiple or single binding sites. Furthermore, an attempt is made to differentiate between methods in which molecular recognition plays a predominant role and methods in which the selectivity depends on overall differences in physicochemical properties between the analytes. The calculation of the resolution for the different separation modes and the requirements for qualitative and quantitative analysis are discussed. It is anticipated that selectivity tuning is easier in separation modes in which molecular recognition plays a role. However, sufficient attention needs to be paid to the efficiency of the system in that it not only affects resolution but also detectability of the analyte of interest.  相似文献   

15.
H Nishi  S Terabe 《Electrophoresis》1990,11(9):691-701
Electrokinetic chromatography is a new type of analytical separation method which belongs to the group of high performance capillary electrophoretic techniques but whose separation principle is based on that of chromatography. The solute distributes itself between a carrier and the surrounding medium. The carrier, which corresponds to the stationary phase in conventional chromatography, can be transported by electrophoresis with a different velocity from the surrounding medium. The separation is achieved by the differential solute distribution and the differential migration of the carrier. The charged molecules or charged molecular aggregates are employed as the carrier. Various kinds of carriers are available for electrokinetic chromatography along with different partition mechanisms. Among them, micellar electrokinetic chromatography, which employs an ionic micelle as a carrier, has become the most popular method because of its unique and attractive characteristics as well as the separating capability of electrically neutral or nonionic solutes in comparison with capillary zone electrophoresis. The present paper describes the principle, separation characteristics and its application to the analysis of pharmaceuticals.  相似文献   

16.
Generally reversed-phase high-performance liquid chromatography (RP-HPLC) methods are extensively applied during quality control of pharmaceutical products. Since capillary electrophoresis (CE) is based on a different separation principle and consequently results in a unique selectivity compared to RP-HPLC, it can advantageously be used as an orthogonal technique. CE equipped with a mass spectrometer detector provides even more information that can be helpful for identification and structural elucidation purposes. CE-MS was recently implemented in the method development approach to support impurity profiling of pharmaceutical products. In this paper the application of CE-electrospray ionization (ESI)-MS/MS to the impurity profiling of galantamine hydrobromide in stressed Reminyl Extended Release (ER) capsules is discussed. Reminyl ER samples were stressed at different storing conditions. The impurity profile of these samples was compared with the current RP-HPLC and chiral CE method, but also with CE-ESI-MS/MS. The combination of these three methods provided valuable data that allowed understanding comprehensively the impurity profile of these samples. Two impurities were detected at concentrations lower than 0.05%, which did not occur in nonstressed samples. Chromatographic data and the fragmentation patterns of galantamine and related compounds were also examined for identification of these two degradation products.  相似文献   

17.
将在线富集技术同二维(2D)毛细管电泳(CE)分离相结合同时提高复杂样品中痕量组分的分离度和检测灵敏度.毛细管区带电泳(CZE)作为第一维,分析物根据淌度不同进行分离,第一维流出组分进入第二维毛细管,根据分配系数不同进行胶束电动毛细管色谱(MEKC)分离.采用阳离子选择性耗尽进样(CSEI)在柱预富集,延长进样时间,增大进样量;同时在二维毛细管接口处采用动态pH联接/胶束扫集在线富集技术不仅避免第一维分离组分在接口处扩散,还可进一步压缩样品区带.同常规电动进样CE分离相比,该在线富集二维分离技术的分离能力远远高于一维CZE或MEKC分离,富集倍数达到(0.5~1.2)×104.该法成功应用于人体尿样中四种药物及对映体的分析测定,浓度检出限为0.1~0.3μg/L.进一步研究了人体尿样中四种药物24h内的药代动力学规律.  相似文献   

18.
A novel method has been developed by integration of multi-concentration and two-dimensional(2D) capillary electrophoresis(CE) for simultaneous enhancement of detection sensitivity and separation power in complex samples.Capillary zone electrophoresis(CZE) was used as the first dimension separation according to mobilities,from which the effluent fractions were further analyzed by micellar electrokinetic capillary chromatography(MEKC) acting as the second dimension.Cation-selective exhaustive injection(CSEI) ...  相似文献   

19.
Analytical chemistry of metallothioneins based on the coupling of a high resolution separation technique with an element or species selective detection technique is discussed. The role of size-exclusion chromatography (SEC) with on-line atomic spectrometric detection for the quantification of metallothionein fraction in cell cytosols is evaluated. Particular attention is given to the conditions for the separation of metallated metallothionein isoforms (MT-1, MT-2, MT-3) and sub-isoforms within these classes by anion-exchange and reversed-phase HPLC. Techniques for interfacing chromatography with atomic absorption spectrometry (AAS), inductively coupled plasma atomic emission spectrometry (ICP AES) and ICP mass spectrometry (MS) are assessed. The potential of electrospray (tandem) mass spectrometry for the characterization of metallothionein isoforms with respect to molecular mass and aminoacid sequence is highlighted. Perspectives for capillary zone electrophoresis (CZE), microbore and capillary HPLC with ICP MS and electrospray MS(/MS) detection for the probing of metallothioneins are discussed. Applications of hyphenated techniques to the analysis of real-world samples are reviewed.  相似文献   

20.
温涛  赵霞  罗国安  王义明  王俭  朱军  于忠山 《分析化学》2006,34(11):1529-1534
通过毛细管微乳液电动色谱10 m in内同时分离了安非他明、甲基安非他明、4,5-亚甲基二氧基安非他明(MDA)和3-甲氧基-4,5-亚甲基二氧基安非他明(MDMA)4种苯丙胺类毒品及其麻黄碱、伪麻黄碱、甲基麻黄碱、甲基伪麻黄碱、去甲麻黄碱等麻黄生物碱杂质。比较了毛细管微乳液电动色谱和丁醇改进的胶束电动色谱模式对分离的影响,发现正丁醇是影响分离的最主要因素。本方法具有很好的重复性和稳定性,可实现对冰毒及其麻黄生物碱杂质的快速分析和鉴定,相对保留时间和相对峰面积的RSD分别小于1.3%和5.0%,可用于冰毒的实际来源推断。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号