共查询到20条相似文献,搜索用时 0 毫秒
1.
Summary The determinations of phenol is studied by means of a carbon paste electrode modified with 10% sepiolite using DPV. A 10 min preconcentration step was performed at pH 1.5 under open circuit conditions. Measurements were made in another cell by DPV with E=100 mV (sweep rate = 40 mV/s) in 0.02 mol/l KNO3 medium at pH 2. Detection limits (3 ) of 30 ng/ml were achieved for determinations in orange, lemon and cola drinks.
Phenolbestimmung durch Differentialpuls-Voltammetrie mit einer Sepiolit-modifizierten Kohlepaste-Elektrode相似文献
2.
L. Hernandez P. Hernandez Z. Sosa Ferrera 《Fresenius' Journal of Analytical Chemistry》1988,329(7):756-759
Summary The determination of aniline by means of a carbon paste electrode (CPE) modified with 10% sepiolite was studied using differential pulse voltammetry. The best pre-concentration was achieved at pH 6.9 over 5 min and the besti
p in the measuring cell was obtained at pH 1.5 using E = 100 mV and a scan rate of 40 mV/s.Under these conditions detection limits (10 ) of 15 ng/ ml were obtained. The method was applied to different beverages without the need for prior separation.
Differentialpuls-voltammetrische Bestimmung von Anilin mit einer Sepiolit-modifizierten Kohlepaste-Elektrode相似文献
3.
A simple and effective chemically modified carbon paste electrode (CMCPE) for the simultaneous determination of lead(II) and cadmium(II) was developed in this work. The electrode was prepared by the addition of diacetyldioxime into a carbon paste mixture. Pb2+ and Cd2+ were preconcentrated on the surface of the modified electrode by complexing with diacetyldioxime and reduced at a negative potential (−1.10 V). Then the reduced products were oxidized by differential pulse stripping. The fact that two stripping peaks appeared on the voltammograms at the potentials of −0.65 V (Cd2+) and −0.91 V (Pb2+) demonstrates the possibility of simultaneous determination of Pb2+ and Cd2+. Under the optimized working conditions, calibration graphs were linear in the concentration ranges of 1.0×10−7-1.5×10−5 mol l−1 (Pb2+) and 2.5×10−7-2.5×10−5 mol l−1 (Cd2+), respectively. For 5 min preconcentration, detection limits of 1×10−8 mol l−1 (Pb2+) and 4×10−8 mol l−1 (Cd2+) were obtained at the signal noise ratio (SNR) of 3. To evaluate the reproducibility of the newly developed electrode, the measurements of 5×10−7 mol l−1 Pb2+ and Cd2+ were parallel carried out for six times at different electrodes and the relative standard deviations were 2.9% (Pb2+) and 3.2% (Cd2+), respectively. Interferences by some metals were investigated. Only Ni2+ and Hg2+ apparently affected the peak currents of Pb2+ and Cd2+. The diacetyldioxime modified carbon paste electrode was applied to the determination of Pb2+ and Cd2+ in water samples. The results indicate that this electrode is sensitive and effective for the simultaneous determination of Pb2+ and Cd2+. 相似文献
4.
Butylated hydroxyanisole (BHA) and other tocopherols are shown to accumulate very strongly onto carbon paste, with the surface species retaining their characteristic electroactivity. This accumulation serves as a preconcentration step which improves the voltammetric measurement with respect to the sensitivity and selectivity. After 5-min preconcentration, a detection limit near 2 × 10?8 M BHA is obtained. Enhanced selectivity is achieved if the electrode is transferred into an electrolytic blank solution between the preconcentration and measurement steps. The accumulated analyte can then be quantified in the presence of a 103-fold amount of a solution species with similar redox potential. The differential pulse stripping response is evaluated with respect to concentration dependence, reproducibility, preconcentration period, detection limit, and other variables. The preconcentration/medium exchange approach is exploited for selective detection of BHA in a flow injection system. Applicability to various real samples is illustrated. 相似文献
5.
建立了快速测定盐酸金霉素(CTC)的方法。通过NaBH4还原法制备纳米银(AgNPs)溶胶,并利用X射线衍射和紫外-可见光谱进行表征。将制备好的AgNPs滴涂到玻碳电极表面制备修饰电极(AgNPs/GCE),研究了CTC在AgNPs/GCE上的电化学行为及伏安法测定,优化了缓冲溶液和pH等检测条件。结果表明,CTC在pH 3.3的柠檬酸-NaOH-HCl缓冲溶液中检测效果最佳。CTC在AgNPs/GCE上发生2个电子和2个质子的不可逆电化学氧化反应,且反应受吸附控制。最佳条件下,CTC的氧化峰电流与其浓度呈现良好的线性关系,线性范围为0.5~100μmol/L,检出限为0.14μmol/L。该修饰电极可用于河水样品检测。 相似文献
6.
A sensitive and selective method for the determination of procaine hydrochloride with a Nafion-modified glassy carbon electrode has been developed. The voltammetric behavior of procaine hydrochloride on the Nafion-modified electrode indicated that the modified electrode not only increased the sensitivity of the determination of procaine hydrochloride, but also catalyzed the electrode process. Procaine hydrochloride was accumulated in Britton-Robinson buffer (pH 2.09) at a potential of -0.2 V (vs. SCE) for 180 s, and was then determined by differential pulse adsorptive stripping voltammetry. The effect of various parameters, such as the pH of the medium, the mass of drop-coated Nafion, the accumulation potential, the accumulation time and the scan rate, were investigated. Under the optimum conditions, a linear calibration graph was obtained in the concentration range of 6.0 x 10(-8) to 6.0 x 10(-6) mol l(-1) with a correlation coefficient of 0.9987. The relative standard deviation was 4.18% for eight successive determinations of 1.0 x 10(-7) mol l(-1) procaine hydrochloride, and the detection limit (three times signal to noise) was 7.0 x 10(-9) mol l(-1). A study of interfering substances was also performed, and the method was applied to the direct determinations of procaine hydrochloride in the injection solution of procaine hydrochloride and in rabbit serum. 相似文献
7.
The use of selective pre-concentration and differential pulse anodic stripping voltammetry (DPASV) using a carbon paste electrode modified (CPEM) with spinel-type manganese oxide has been proposed for the determination of lithium ions content in natural waters. The new procedure is based on the effective pre-concentration of lithium ions on the electrode surface containing spinel-type Mn(IV) oxide with the reduction of Mn(IV) to Mn(III) and consequently the lithium ions intercalation (insertion) into the spinel structure. The best DPASV response was reached for an electrode composition of 25% (m/m) spinel-type MnO2 in the paste, 0.1 mol l−1 tris(hydroxymethyl)aminomethane (TRIS) buffer solution of pH 8.3, scan rate of 5 mV s−1, accumulation potential of 0.3 V versus saturated calomel reference electrode (SCE), pre-concentration time of 30 s and potential pulse amplitude of 50 mV. In these experimental conditions, the proposed methodology responds to lithium ions in the concentration range of 2.8×10−6 to 2.0×10−3 mol l−1 with a detection limit of 5.6×10−7 mol l−1. The determination of the lithium ions content in different samples of natural waters samples using the proposed methodology and atomic absorption spectrophotometry are in agreement at the 95% confidence level and within an acceptable range of error. 相似文献
8.
9.
A differential pulse anodic stripping voltammetry was developed for the sensitive and selective determination of Co(II) at 2,4,6-tri(3,5-dimethylpyrazoyl)-1,3,5-triazine modified carbon paste electrode in 0.1 mol l(-1) NH(4)Cl solution (pH 4.95). The oxidation peak of Co(II) was observed at 0.03 V(vs. Ag/AgCl) by scanning the potential in a positive direction. The analysis procedure consisted of an open circuit accumulation step in stirred sample solution. This was followed by medium exchange to a clean solution and subsequently an anodic potential scan was effect to obtain the voltammetric peak. The current was proportional to the concentration of the Co(II) ion in a range of 1x10(-8)-1x10(-6) mol l(-1) for 3 min accumulation and in the range of 1x10(-9)-1x10(-8) mol l(-1) for 5 min accumulation; most of metal ions do not interfere with the determination. The developed method was applied to Co(II) determination in potable water. 相似文献
10.
Shokoofe Jahandari Mohammad Ali Taher Hamid Fazelirad Iran Sheikhshoai 《Mikrochimica acta》2013,180(5-6):347-354
We describe a silver(I)-selective carbon paste electrode modified with multi-walled carbon nanotubes and a silver-chelating Schiff base, and its electrochemical response to Ag(I). Effects of reduction potential and time, accumulation time, pH of the solution and the stripping medium were studied by differential pulse anodic stripping voltammetry and optimized. The findings resulted in a method for the determination of silver over a linear response range (from 0.5 to 235 ng?mL?1) and with a detection limit as low as 0.08 ng?mL?1. The sensor displays good repeatability (with the RSD of ±?2.75 % for 7 replicates) and was applied to the determination of Ag(I) in water samples and X-ray photographic films. Figure
Open circuit accumulation of Ag(I) onto a surface of EHPO-MCPE and determination by Differential pulse anodic stripping voltammetry 相似文献
11.
采用线性循环溶出伏安法和差分脉冲溶出伏安法对磺胺嘧啶在电活化玻碳电极上的电化学行为进行了研究。玻碳电极在PBS溶液中(pH 7.0),用恒电位法在1.7 V阳极氧化400 s,在B-R缓冲溶液中,磺胺嘧啶在1.02V(vs.Ag/AgCl)处有一良好的氧化峰,在0.02~0.25 V/s范围内,其氧化峰电流与扫描速率呈良好线性关系,表明电极过程为受吸附控制的不可逆过程。差分脉冲溶出伏安法的氧化峰电流(Ipa)与磺胺嘧啶浓度1×10-6~1×10-4mol/L范围内呈良好的线性关系(r=0.9977),检出限为8.7×10-7mol/L(S/N=3)。方法已用于分析磺胺嘧啶片剂的分析。 相似文献
12.
碳糊修饰电极吸附伏安法测定食品中的锑 总被引:3,自引:0,他引:3
研制了溴邻苯三酚红 (BPR)作修饰剂的碳糊修饰电极 ,并用此电极作工作电极建立了测定痕量锑的吸附伏安法。在选定的实验条件下 ,峰电流与Sb(Ⅲ )浓度在 8.0× 1 0 -9~ 2 .0× 1 0 -7mol L范围内呈线性关系 ,检出限为 2 .0×1 0 -9mol L ,1 0次测定相对标准偏差为 2 .0 % ,不用分离 ,可直接测定食品中痕量Sb(Ⅲ ) ,测定的回收率为 90 %~ 1 0 3%。 相似文献
13.
Shokoofe Jahandari Mohammad Ali Taher Hamid Fazelirad 《International journal of environmental analytical chemistry》2013,93(9):930-942
A new modified carbon paste electrode based on multi-walled carbon nanotube and Alizarin Red S acts as a chelating agent for tellurium(IV) ions, is described. The electrochemical responses were found to be analytically suitable to develop a method for the determination of tellurium at low concentration levels. Under optimised operational conditions, the sensor exhibited linear behaviour in the range of 2.0–300 ng mL?1 (correlation coefficient: 0.9982) with a detection limit of 0.45 ng mL?1. The results indicate that the sensor is sensitive and effective for the determination of tellurium in water samples and certified reference materials. 相似文献
14.
Chemically modified carbon paste eletrodes are prepared by incorporating appropriate quantities of a cation-exchange resin directly into the paste mixture. Ionic analytes can be preconcentrated on these electrodes by an ion-exchange reaction rather than electrolytic plating. Differential pulse voltammetry is used to quantify the accumulated ions. The response is characterized with respect to preconcentration period, bulk concentration, pH, paste composition, reproducibility, and other variables. Copper ion is used as a test system. The procedure exhibits good linearity for 6.25 × 10?5?3.0 × 10?4 M copper(II) ions and the peak current varies linearly with preconcentration time between 1 and 7 min for the conditions used. 相似文献
15.
16.
碳糊电极阳极吸附伏安法测定洛美沙星 总被引:3,自引:0,他引:3
报道了碳糊电极阳极吸附伏安法测定洛美沙星的新方法。在0.096mol L的KHP NaOH(pH5.4)缓冲液中,用碳糊电极为工作电极,在0.3V(vs.SCE)富集一定时间,然后从0.3~1 3V以300mV s扫速线性扫描,记录其在1 02V的二次导数阳极溶出峰。溶出峰电流与洛美沙星浓度在8.0×10-9~8.0×10-8mol L(富集90s)和8.0×10-8~8.0×10-7mol L(富集30s)范围内呈良好的线性关系,相关系数分别为0.9844和0.9967,检出限为9.0×10-10mol L(S N=3)。探讨了洛美沙星在碳糊电极上的伏安性质和电极反应机理,并且成功地应用于人体尿液中洛美沙星的测定,结果与紫外光度法基本吻合。 相似文献
17.
Solid paraffin-based carbon paste electrodes modified with 2-aminothiazole organofunctionalized silica have been applied to the anodic stripping determination of copper ions in ethanol fuel samples without any sample treatment. The proposed method comprised four steps: (1) copper ions preconcentration at open circuit potential directly in the ethanol fuel sample; (2) exchange of the solution and immediate cathodic reduction of the absorbate at controlled potential; (3) differential pulse anodic stripping voltammetry; (4) electrochemical surface regeneration by applying a positive potential in acid media. Factors affecting the preconcentration, reduction and stripping steps were investigated and the optimum conditions were employed to develop the analytical procedure. Using a preconcentration time of 20 min and reduction time of 120 s at −0.3 V versus Ag/AgClsat a linear range from 7.5 × 10−8 to 2.5 × 10−6 mol L−1 with detection limit of 3.1 × 10−8 mol L−1 was obtained. Interference studies have shown a decrease in the interference effect according to the sequence: Ni > Zn > Cd > Pb > Fe. However, the interference effects of these ions have not forbidden the application of the proposed method. Recovery values between 98.8 and 102.3% were obtained for synthetic samples spiked with known amounts of Cu2+ and interfering metallic ions. The developed electrode was successfully applied to the determination of Cu2+ in commercial ethanol fuel samples. The results were compared to those obtained by flame atomic absorption spectroscopy by using the F-test and t-test. Neither F-value nor t-value have exceeded the critical values at 95% confidence level, confirming that there are no significant differences between the results obtained by both methods. 相似文献
18.
In the present work, carbon paste electrodes (CPE) modified with conducting polymers 1,8-diaminonaphtalene (DAN) was developed for the voltammetric determination of Cu(II). The modified electrode exhibited a significantly increased sensitivity
and selectivity for Cu2+ compared with a bare carbon paste electrode. Copper(II) was preconcentrated at open circuit on the modified electrode. The
measurements were carried out using a rotating disk electrode (RDE) as working electrode. The experimental parameters for the determination of Cu(II) were optimized. The Cu(II) ions were chemically
deposited onto the surface of poly DAN-CPE in an acidic medium. Under the optimum conditions, a linear calibration graph was
obtained in the concentration range of 0.1 to 250 ppb with a correlation coefficient of 0.9998. The relative standard deviation
for 6 successive determinations was 4.7%. A study of interfering substances was also performed, and the method was applied
to the direct determination of copper in real samples like tap water and orange juice samples.
The article is published in the original. 相似文献
19.
Electrochemical solid phase nano-extraction, a novel sample preparation technique, was used for the determination of trace iodide in iodised table salt based on the silver sulfate nanoparticle-modified carbon paste electrode. Electrochemical solid phase nano-extraction was realized in the exchange between the sulfate anion in nanoparticles and an iodide anion from aqueous solution. The released silver cation serves as the electrochemical probe for the determination of iodide. The extraction follows a Freundlich adsorption isotherm, and can be used in the detection of iodide in the concentration range 5.0 × 10−12-4.0 × 10−9 M. The amount of iodide in iodised table salt was determined as 0.875 ± 0.002 μg/g, which is about 2.5% of the addition amount of iodate with a relative deviation of 5.92% and a standard addition recovery of 90-110%. The large amounts of chloride and iodate did not interfere with the detection. 相似文献