首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wang X  Leung AW  Jiang Y  Yu H  Li X  Xu C 《Ultrasonics》2012,52(4):543-546

Objective

The present study aims to investigate apoptosis of hepatocellular carcinoma cells induced by hypocrellin B-mediated sonodynamic action.

Methods

The hypocrellin B concentration was kept constant at 2.5 μM and cells from the hepatocellular carcinoma HepG2 cell line were exposed to ultrasound with an intensity of 0.46 W/cm2 for 8 s. Cell cytotoxicity was quantified using an MTT assay 24 h after sonodynamic therapy (SDT) of hypocrellin B. Apoptosis was investigated using a flow cytometry with Annexin V-FITC and propidium iodine staining. Intracellular reactive oxygen species (ROS) levels were detected using a flow cytometry with 2,7-dichlorodihydrofluorecein diacetate (DCFH-DA) staining.

Results

The cytotoxicity of hypocrellin B-mediated sonodynamic action on HepG2 cells was significantly higher than those of other treatments including ultrasound alone, hypocrellin B alone and sham treatment. Flow cytometry showed that hypocrellin B-induced sonodynamic action markedly enhanced the apoptotic rate of HepG2 cells. Increased ROS was observed in HepG2 cells after being treated with hypocrellin B-mediated sonodynamic action.

Conclusions

Our data demonstrated that hypocrellin B-mediated sonodynamic action remarkably induced apoptosis of HepG2 cells, suggesting that apoptosis is an important mechanism of cell death induced by hypocrellin B-mediated SDT.  相似文献   

2.

Objective and motivation

The goal of this work was to test experimentally that exposing air bubbles or ultrasound contrast agents in water to amplitude modulated wave allows control of inertial cavitation affected volume and hence could limit the undesirable bioeffects.

Methods

Focused transducer operating at the center frequency of 10 MHz and having about 65% fractional bandwidth was excited by 3 μs 8.5 and 11.5 MHz tone-bursts to produce 3 MHz envelope signal. The 3 MHz frequency was selected because it corresponds to the resonance frequency of the microbubbles used in the experiment. Another 5 MHz transducer was used as a receiver to produce B-mode image. Peak negative acoustic pressure was adjusted in the range from 0.5 to 3.5 MPa. The spectrum amplitudes obtained from the imaging of SonoVueTM contrast agent when using the envelope and a separate 3 MHz transducer were compared to determine their cross-section at the - 6 dB level.

Results

The conventional 3 MHz tone-burst excitation resulted in the region of interest (ROI) cross-section of 2.47 mm while amplitude modulated, dual-frequency excitation with difference frequency of 3 MHz produced cross-section equal to 1.2 mm.

Conclusion

These results corroborate our hypothesis that, in addition to the considerably higher penetration depth of dual-frequency excitation due to the lower attenuation at 3 MHz than that at 8.5 and 11.5 MHz, the sample volume of dual-frequency excitation is also smaller than that of linear 3-MHz method for more spatially confined destruction of microbubbles.  相似文献   

3.

Background

Measurement of surface roughness irregularities that result from various sources such as manufacturing processes, surface damage, and corrosion, is an important indicator of product quality for many nondestructive testing (NDT) industries. Many techniques exist, however because of their qualitative, time-consuming and direct-contact modes, it is of some importance to work out new experimental methods and efficient tools for quantitative estimation of surface roughness.

Objective and method

Here we present continuous-wave ultrasound reflectometry (CWUR) as a novel nondestructive modality for imaging and measuring surface roughness in a non-contact mode. In CWUR, voltage variations due to phase shifts in the reflected ultrasound waves are recorded and processed to form an image of surface roughness.

Results

An acrylic test block with surface irregularities ranging from 4.22 μm to 19.05 μm as measured by a coordinate measuring machine (CMM), is scanned by an ultrasound transducer having a diameter of 45 mm, a focal distance of 70 mm, and a central frequency of 3 MHz. It is shown that CWUR technique gives very good agreement with the results obtained through CMM inasmuch as the maximum average percent error is around 11.5%.

Conclusion

Images obtained here demonstrate that CWUR may be used as a powerful non-contact and quantitative tool for nondestructive inspection and imaging of surface irregularities at the micron-size level with an average error of less than 11.5%.  相似文献   

4.

Objective

Fully automatic tissue characterization in intravascular ultrasound systems is still a challenge for the researchers. The present work aims to evaluate the feasibility of using the Higuchi fractal dimension of intravascular ultrasound radio frequency signals as a feature for tissue characterization.

Methods

Fractal dimension images are generated based on the radio frequency signals obtained using mechanically rotating 40 MHz intravascular ultrasound catheter (Atlantis SR Plus, Boston Scientific, USA) and compared with the corresponding correlation images.

Conclusion

An inverse relation between the fractal dimension images and the correlation images was revealed indicating that the hard or slow moving tissues in the correlation image usually have low fractal dimension and vice-versa. Thus, the present study suggests that fractal dimension images may be used as a feature for intravascular ultrasound tissue characterization and present better resolution then the correlation images.  相似文献   

5.

Objectives

Curcumin, a natural pigment from the traditional Chinese herb, has shown promise as an efficient enhancer of ultrasound. The present study aims to investigate ultrasound-induced cellular destruction of nasopharyngeal carcinoma cells in the presence of curcumin in vitro.

Methods

Nasopharyngeal carcinoma cell line CNE2 cells were incubated by 10 μm curcumin and then were treated by ultrasound for 8 s at the intensity of 0.46 W/cm2. Cytotoxicity was evaluated using MTT assay and light microscopy. Mitochondrial damage was analyzed using a confocal laser scanning microcopy with Rhodamine 123 and ultrastructural changes were observed using a transmission electron microscopy (TEM).

Results

MTT assay showed that cytotoxicity induced by ultrasound treatment alone and curcumin treatment alone was 18.16 ± 2.37% and 24.93 ± 8.30%, respectively. The cytotoxicity induced by the combined treatment of ultrasound and curcumin significantly increased up to 86.67 ± 7.78%. TEM showed that microvillin disappearance, membrane blebbing, chromatin condensation, swollen mitochondria, and mitochondrial myelin-like body were observed in the cells treated by ultrasound and curcumin together. The significant collapse of mitochondrial membrane potential (MMP) was markedly observed in the CNE2 cells after the combined treatment of curcumin and ultrasound.

Conclusions

Our findings demonstrated that ultrasound sonication in the presence of curcumin significantly killed the CNE2 cells and induced ultrastructural damage and the dysfunction of mitochondria, suggesting that ultrasound treatment remarkably induced cellular destruction of nasopharyngeal carcinoma cells in the presence of curcumin.  相似文献   

6.
Wang X  Wang Y  Wang P  Cheng X  Liu Q 《Ultrasonics》2011,51(5):539-546

Objective

The purpose of this study was to evaluate sonodynamically induced anti-tumor effect of protoporphyrin IX (PPIX) in mice bearing hepatoma-22 (H-22) solid tumors, and the possible in vivo cell damage mechanism was also investigated.

Methods

The pharmacokinetics of PPIX was analyzed in plasma, skin, muscle and tumor of H-22 bearing mice. Tumors were irradiated with ultrasound (1.43 MHz, ISATA 3 W/cm2, 3 min) for three times at 8, 12 and 24 h after 5.0 mg/kg PPIX administration, respectively. The anti-tumor effects of sonodynamic therapy (SDT) were estimated by the tumor inhibition ratio (volume and weight). The bio-effects of SDT were evaluated by hematoxylin and eosin (H&E) staining, transmission electron microscope (TEM) observation, lipid peroxidation (LPO) measurement and anti-oxidative enzymes (glutathione peroxidase (GSH-PX), catalase (CAT) and superoxide dismutase (SOD)) assay.

Results

A significant anti-tumor effect was obtained by PPIX-mediated sonodynamic therapy (PPIX-SDT). At the fifteenth day after PPIX-SDT, the tumor growth and tumor weight inhibition ratios were 53.84% and 45.86%, respectively. In addition, the structure of tumor tissues and the anti-oxidative enzymes were obviously destroyed after SDT treatment.

Conclusions

A biochemical mechanism was involved in PPIX-SDT in vivo, and the free radicals produced by the synergistic treatment destroying the anti-oxidative system of tumor cells in vivo may play an important role in this action. Also, the thermal effect could not be excluded in inducing damage of cellular structures, like membrane disruption and chromatin condensation under current evaluation in this paper.  相似文献   

7.

Objectives

To test the effect of pulsed (Q-switched) and continuous wave (CW) laser light at wavelength of 532 nm on the viability of free-living stationary phase bacteria with and without gentamicin (an antibiotic) treatment.

Methods

Free living stationary phase gram negative bacteria (Pseudomonas aeruginosa strain PAO1) was immersed in Luria Broth (LB) solution and exposed to Q-switched and CW lasers with and without the addition of the antibiotic gentamicin. Cell viability was determined at different time points.

Results

Laser treatment alone did not reduce cell viability compared to untreated control and the gentamicin treatment alone only resulted in a 0.5 log reduction in the viable count for P. aeruginosa. The combined laser and gentamicin treatment, however, resulted in a synergistic effect and viability was reduced by 8 logs for P. aeruginosa PAO1.

Conclusions

Combination of laser light with gentamicin shows an improved efficacy against P. aeruginosa.  相似文献   

8.
Shen CC  Su SY  Cheng CH  Yeh CK 《Ultrasonics》2012,52(1):25-32

Objective

The goal of this work is to examine the effects of pulse-inversion (PI) technique in combination with dual-frequency (DF) excitation method to separate the high-order nonlinear responses from microbubble contrast agents for improvement of image contrast. DF excitation method has been previously developed to induce the low-frequency ultrasound nonlinear responses from bubbles by using the composition of two high-frequency sinusoids (f1 and f2).

Motivation

Although the simple filtering was conventionally utilized to provide signal separation, the PI approach is better in the sense that it minimizes the mutual interferences among these high-order nonlinear responses in the presence of spectral overlap. The novelty of the work is that, in addition to the common PI summation, the PI subtraction was also applied in DF excitation method.

Methods

DF excitation pulses having an envelope frequency of 3 MHz (i.e., f1 = 8.5 MHz and f2 = 11.5 MHz) with pulse lengths of 3-10 μs and the pressure amplitudes from 0.5 to 1.5 MPa were used to interrogate the nonlinear responses of SonoVue™ microbubbles in the phantom experiments. The high-order nonlinear responses in the DF excitation were extracted for contrast imaging using PI summation for even-order nonlinear components or PI subtraction for odd-order nonlinear ones.

Results

Our results indicated that, as compared to the conventional filtering technique, the PI processing effectively increases the contrast-to-tissue ratio (CTR) of the third-order nonlinear response at 5.5 MHz and the fourth-order nonlinear response at 6 MHz by 2-5 dB. For these high-order nonlinear components, the CTR increase varies with the transmission pressures from 0.5 to 1.5 MPa due to the microbubbles’ displacement induced by the radiation force of DF excitation.

Conclusions

For DF excitation technique, the PI processing can help to extract either the odd-order or the even-order nonlinear components for higher CTR estimates.  相似文献   

9.

Purpose

This study aimed to develop a 0.014-in., anti-solenoid loop (ASL) magnetic resonance imaging guidewire (MRIG) for intravascular 3.0-T MR imaging.

Materials and Methods

We first designed the ASL MRIG, which was made of a coaxial cable with its extended inner conductor and outer conductor connected to two micro-anti-solenoids. We then evaluated in vitro the functionality of the ASL MRIG by imaging a “vessel” in a phantom and achieving signal-to-noise ratio (SNR) and SNR contour map of the new 0.014-in. ASL MRIG. Subsequently, we validated in vivo the feasibility of using the ASL MRIG to generate intravenous 3.0-T MR images of parallel iliofemoral arteries of near-human-sized living pigs.

Results

In vitro evaluation showed that the 0.014-in. ASL MRIG functioned well as a receiver coil with the 3.0-T MR scanner, clearly displaying the vessel wall with even distribution of MR signals and SNR contours from the ASL MRIG. Of the in vivo studies, the new ASL MRIG enabled us to successfully generate intravenous 3.0-T MR imaging of the iliofemoral arteries.

Conclusion

This study confirms that it is possible to build such small-looped MRIG at 0.014 in. for intravascular 3.0-T MR imaging.  相似文献   

10.

Purpose

The purpose of our study was to compare diffusion-weighted MR imaging (DWI) with conventional dynamic MRI in terms of the assessment of small intrahepatic metastases from hepatocellular carcinoma (HCC).

Materials and Methods

In 24 patients with multifocal, small (≤2 cm) intrahepatic metastatic foci of advanced HCC, a total of 134 lesions (≤1 cm, n=81; >1 cm, n=53) were subjected to a comparative analysis of hepatic MRI including static and gadopentetate dimeglumine-enhanced dynamic imaging, and DWI using a single-shot spin-echo echo-planar MRI (b values=50, 400 and 800 s/mm2), by two independent reviewers.

Results

A larger number of the lesions were detected and diagnosed as intrahepatic metastases on DWI [Reviewer 1, 121 (90%); Reviewer 2, 117 (87%)] than on dynamic imaging [Reviewer 1, 107 (80%); Reviewer 2, 105 (78%)] (P<.05). For the 81 smaller lesions (≤1 cm), DWI was able to detect more lesions than dynamic imaging [Reviewer 1, 68 (84%) vs. 56 (69%), P=.008; Reviewer 2, 65 (80%) vs. 55 (68%), P=.031], but there was no statistically significant difference between the two image sets for larger (>1 cm) lesions.

Conclusion

Due to its higher detection rate of subcentimeter lesions, DWI could be considered complementary to dynamic MRI in the diagnosis of intrahepatic metastases of HCCs.  相似文献   

11.

Background

High-frequency ultrasonic transducer arrays are essential for high resolution imaging in clinical analysis and Non-Destructive Evaluation (NDE). However, the fabrication of conventional backing-layer structure, which requires a pitch (distance between the centers of two adjacent elements) of half wavelength in medium, is really a great challenge.

Objective and method

Here we present an alternative buffer-layer structure with a silicon lens for volumetric imaging. The requirement for the size of the pitch is less critical for this structure, making it possible to fabricate high-frequency (100 MHz) ultrasonic linear array transducers. Using silicon substrate also makes it possible to integrate the arrays with IC (Integrated Circuit). To compare with the conventional backing-layer structure, a finite element tool, COMSOL, is employed to investigate the performances of acoustic beam focusing, the influence of pitch size for the buffer-layer configuration, and to calculate the electrical properties of the arrays, including crosstalk effect and electrical impedance.

Results

For a 100 MHz 10-element array of buffer-layer structure, the ultrasound beam in azimuth plane in water could be electronically focused to obtain a spatial resolution (a half-amplitude width) of 86 μm at the focal depth. When decreasing from half wavelength in silicon (42 μm) to half wavelength in water (7.5 μm), the pitch sizes weakly affect the focal resolution. The lateral spatial resolution is increased by 4.65% when the pitch size decreases from 42 μm to 7.5 μm. The crosstalk between adjacent elements at the central frequency is, respectively, −95 dB, −39.4 dB, and −60.5 dB for the 10-element buffer, 49-element buffer and 49-element backing arrays. Additionally, the electrical impedance magnitudes for each structure are, respectively, 4 kΩ, 26.4 kΩ, and 24.2 kΩ, which is consistent with calculation results using Krimholtz, Leedom, and Matthaei (KLM) model.

Conclusion

These results show that the buffer-layer configuration is a promising alternative for the fabrication of high-frequency ultrasonic linear arrays dedicated to volumetric imaging.  相似文献   

12.

Introduction

Elastic modulus estimation may be an important clinical criterion, as it seems to affect such eye parameters as intraocular pressure, ocular pulsation, blood flow, effect of topical medications, and post-refractive surgery complications. The purpose of this study was to examine the differences in elasticity in the ocular axial length, posterior wall thickness (posterior pole), and retina-choroid thickness under normal and aged-related macular degeneration (AMD) conditions in the human eye by directly estimating the elastic modulus with sequential and noninvasive ultrasound image processing.

Materials and Methods

In this study, 25 healthy subjects and 20 patients with non-neovascular AMD participated in the experiment. The deformation of the ocular axial length, posterior wall thickness and retina-choroid complex thickness was captured using high-resolution ultrasonography before and after loading. The B-mode (20 MHz) and A-mode (8 MHz) frames were obtained and processed with an echo tracking technique. The elastic modulus was estimated using changes in ocular axial length, posterior wall thickness and retina-choroid complex thickness and with applied stress measurements.

Results

There was a significant difference (p < 0.05) in the ocular axial length elastic modulus between the AMD and healthy subjects (AMD patients: 95.165 ± 26.431 kPa, vs. healthy subjects: 49.539 ± 25.867 kPa). Moreover, there was a statistically significant difference (p < 0.05) in the posterior wall thickness elastic modulus between AMD patients and healthy subjects (AMD patients: 50.519 ± 12.295 kPa, vs. healthy subjects: 20.519 ± 11.827 kPa). However, no statistically significant difference (p-value > 0.05) was found in the retina-choroid complex elastic modulus between the two groups (AMD patients: 20.134 ± 3.898 kPa, vs. healthy subjects: 15.630 ± 4.250 kPa).

Conclusion

Although the results were obtained examining a relatively low number of patients, it would appear that noninvasive ultrasound estimation of the local elastic moduli of ocular axial length and posterior wall thickness is suited to aid in detection of the non-exudative AMD thus manifesting its potential as a screening tool in symptom-free individuals.  相似文献   

13.
Xiang J  Xia X  Jiang Y  Leung AW  Wang X  Xu J  Wang P  Yu H  Bai D  Xu C 《Ultrasonics》2011,51(3):390-395

Objective

The present study aims to investigate apoptosis of ovarian cancer cells induced by methylene blue (MB)-mediated sonodynamic therapy (SDT).

Methods

The MB concentration was kept constant at 100 μM and ovarian cancer HO-8910 cells were exposed to ultrasound therapy for 5 s with an intensity of 0.46 W/cm2. The cytotoxicity was investigated 24 h after MB-mediated sonodynamic action. Apoptosis was analyzed using a flow cytometer with Annexin V-FITC and propidium iodine (PI) staining as well as fluorescence microscopy with Hoechst 33258 staining. Intracellular reactive oxygen species (ROS) level was measured by flow cytometer with 2,7-dichlorodihydrofluorescein diacetate (DCFH-DA) staining.

Results

The cytotoxicity of MB-mediated SDT on HO-8910 cells after MB-mediated SDT was significantly higher than those of other treatments including ultrasound alone, MB alone and sham treatment. Flow cytometric analysis showed a significant increase in the early and late apoptotic cell populations by MB-mediated SDT of HO-8910 cells. Nuclear condensation and increased ROS levels were also found in HO-8910 cells treated by MB-mediated SDT.

Conclusions

Our findings demonstrated that MB-mediated sonodynamic action significantly induced apoptosis of HO-8910 cells and an increase in intracellular ROS level. This indicates that apoptosis is an important mechanism of cell death induced by MB-mediated SDT. Thus, MB-mediated SDT might be a potential therapeutic strategy for combating ovarian cancer.  相似文献   

14.

Introduction

Ultrasound mediated destruction of microbubbles (MBs) has become a promising tool for site specific drug and gene delivery. One of the most important properties of drug-loaded MBs is their destructibility by ultrasound. Therefore, the aim of this study was to establish a new in vitro model that allows evaluation of the kinetics of ultrasound-mediated MB destruction at near physiological conditions.In this work, a newly developed drug-loaded MB formulation was compared with unloaded MBs in order to assess the influence of drug-loading on their acoustic destructibility. Furthermore, drug-loaded MBs were compared to acoustically active lipospheres (AALs), comprising an additional layer of triacetin, as well as to a marketed MB contrast agent (SonoVue®, Bracco Diagnostics, USA), used as standard.

Methods

MBs with phospholipid monolayer shells were produced by mechanical agitation of liposomal dispersions and octafluoropropane gas. AALs were accordingly produced by agitation of phospholipid-stabilized aqueous triacetin microemulsions with gas.The in vitro experimental setup for acoustic destructibility testing comprised a membrane cell, pressurized and brought to 37 °C in order to imitate human blood pressure and body temperature. The optimized egg-like cell shape provided optimal flow conditions and a minimized dead volume.Ultrasound with frequencies of 1 and 3 MHz and intensities, varying from 1 to 4 W/cm2, was applied through a silicone membrane window to the cell. MB size distribution and concentration were measured by light blockage in equal time intervals during the sonication.

Results

The optimized in vitro setup demonstrated differences in the ultrasound destructibility of the MB formulations used. The fastest decay upon ultrasound exposure was found for SonoVue®. Unloaded and drug-loaded MBs appeared to be comparably destructible to SonoVue®. AALs were about 4.5-fold more stable than SonoVue®. MB destructibility was also found to depend on particle diameter, corresponding to theoretical models described in the literature.

Conclusion

The optimized in vitro setup has rendered a fast and reliable laboratory tool for characterization of MB formulations.  相似文献   

15.

Purpose

Real-time tissue elastography, a qualitative elastography method, has shown promising results in the diagnostic work up of thyroid nodules. However, to our knowledge no study has evaluated a quantitative elastography method in the thyroid gland. The present study is a feasibility study evaluating Acoustic Radiation Force Impulse-Imaging, a novel quantitative elastography method in the thyroid gland.

Methods

ARFI-imaging involves the mechanical excitation of tissue using short-duration acoustic pulses to generate localized displacements in tissue. The displacements induce a lateral shear-wave propagation which is tracked using multiple laterally positioned ultrasound “tracking“ beams. Inclusion criteria were: thyroid nodules ?1 cm, non-functioning or hypo-functioning on radionuclide scanning, and cytological/histological assessment of thyroid nodule as reference method. All patients received conventional ultrasound, and examination of the thyroid gland including Power Doppler Ultrasound using a 9 MHz linear transducer, in addition real-time elastography (RTE) was performed at 9 MHz frequency and ARFI-imaging was performed at 4 MHz using Siemens (ACUSON S2000) B-mode-ARFI combination transducer.

Results

Sixty nodules in 55 patients were analyzed. Three nodules were papillary carcinoma. The stiffer the tissue the faster the shear wave propagates. The results obtained indicated that the shear wave velocity in thyroid lobes ranged between 0.5 and 4.9 m/s. The median velocity of ARFI-imaging in the healthy nodule-free thyroid gland, as well as in benign and malignant thyroid nodules was 1.98 m/s (range: 1.20-3.63 m/s), 2.02 m/s (range: 0.92-3.97 m/s), and 4.30 m/s (range: 2.40-4.50 m/s), respectively. While no significant difference in median velocity was found between healthy thyroid tissue and benign thyroid nodules, a significant difference was found between malignant thyroid nodules on the one hand and healthy thyroid tissue (p = 0.018) or benign thyroid nodules (p = 0.014) on the other hand. Specificity of ARFI-imaging for the differentiation of benign and malignant thyroid nodules was comparable with RTE (91-95%).

Conclusions

ARFI can be performed in the thyroid tissue with reliable results.  相似文献   

16.

Objective

Perfluorocarbon-exposed sonicated dextrose albumin microbubbles (PESDA) binds scavenger receptors and can be noninvasively imaged. To enhance imaging, gadolinium (Gd)-labeled PESDA was developed and tested in a model of vascular inflammation by magnetic resonance imaging (MRI).

Methods and Results

Purified human serum albumin (HSA) (5%) was labeled with Gd via the covalent binding of diethylenetriaminepentacetic acid. Abdominal aortic tissues in Sprague-Dawley rats (n=5 per group) were analyzed by 7-T MRI and scanning electron microscopy to evaluate PESDA binding. Labeling-purified 5% human albumin resulted in an average of 16.1 Gd atoms per albumin molecule as determined by atomic absorption. Forty-eight hours after balloon angioplasty, aortic tissue was enhanced with Gd-PESDA as compared to control tissue. 7-T MRI of explanted tissues was sensitive to the detection of retained PESDA. Enhancement of aortic tissue in vivo was present albeit to a lesser extent than explanted tissue from the same animals.

Conclusions

HSA was successfully labeled, and an albumin-based microbubble with Gd was synthesized. This contrast agent, Gd-PESDA, may serve as an additional agent for the MRI evaluation of innate inflammation and used to noninvasively image early vascular pathophysiologic processes.

Condensed Abstract

In this study, Gd-PESDA microbubbles and were synthesized and shown to detect the binding of these microbubbles using MRI in injured aortic tissue. The method for synthesizing Gd-PESDA is detailed, and the proposed utility of this new contrast agent is discussed.  相似文献   

17.

Objective and motivation

Intravascular ultrasound (IVUS) allows in vivo invasive intra-luminal real-time examination of the arterial wall structure. In this study, we aimed to validate for the first time the in vivo IVUS performing as a diagnostic tool by comparison to the well-established histomorphometry approach, in the largely used rat model of carotid angioplasty model that mimics the angioplasty procedure in humans.

Methods

Atherosclerotic lesions were allowed to develop during four weeks after balloon catheter inflation of the left carotid artery, whereas the intact right carotid artery was used as control. Four weeks after injury, a Boston Scientific 40 MHz device to perform IVUS exams in vivo on both carotid arteries. Then, both carotid arteries were examined in vitro by histomorphometry and correlation between IVUS and histomorphometric parameters (plaque plus media cross-sectional areas [CSA] and eccentricity index) were researched.

Results

After ANOVA analysis, comparative statistical analysis showed significant correlations between IVUS and histomorphometry when examining the intact right carotid artery (r = 0.662 with p < 0.003 for plaque plus media CSA; r = 0.774 with p < 0.002 for eccentricity index), but also when exploring the injured left carotid artery (r = 0.805 with p < 0.0001 for plaque plus media CSA; r = 0.775 with p < 0.002 for eccentricity index).

Conclusions and outcome

We report here for the first time the ability of IVUS to study therapeutic vascular effects in vivo in alive rats. This result is of major importance since it will allow this device to be used for restenosis drug testing in rat model of carotid angioplasty.  相似文献   

18.

Background

Permanent prostate brachytherapy (PPB) is a common treatment for early stage prostate cancer. While the modern approach using trans-rectal ultrasound guidance has demonstrated excellent outcome, the efficacy of PPB depends on achieving complete radiation dose coverage of the prostate by obtaining a proper radiation source (seed) distribution. Currently, brachytherapy seed placement is guided by trans-rectal ultrasound imaging and fluoroscopy. A significant percentage of seeds are not detected by trans-rectal ultrasound because certain seed orientations are invisible making accurate intra-operative feedback of radiation dosimetry very difficult, if not impossible. Therefore, intra-operative correction of suboptimal seed distributions cannot easily be done with current methods. Vibro-acoustography (VA) is an imaging modality that is capable of imaging solids at any orientation, and the resulting images are speckle free.

Objective and methods

The purpose of this study is to compare the capabilities of VA and pulse-echo ultrasound in imaging PPB seeds at various angles and show the sensitivity of detection to seed orientation. In the VA experiment, two intersecting ultrasound beams driven at f1 = 3.00 MHz and f2 = 3.020 MHz respectively were focused on the seeds attached to a latex membrane while the amplitude of the acoustic emission produced at the difference frequency 20 kHz was detected by a low frequency hydrophone.

Results

Finite element simulations and results of experiments conducted under well-controlled conditions in a water tank on a series of seeds indicate that the seeds can be detected at any orientation with VA, whereas pulse-echo ultrasound is very sensitive to the seed orientation.

Conclusion

It is concluded that vibro-acoustography is superior to pulse-echo ultrasound for detection of PPB seeds.  相似文献   

19.

Objectives

We introduced a harmonic-to-fundamental ratio (HFR) of the radiofrequency (RF) signals that reduces confounding effects of attenuation. We studied whether HFR analysis of RF signals received from contrast microbubbles allows accurate measurement of the left ventricular (LV) cavity area under varying levels of attenuation.

Background

Attenuation is a fundamental problem in ultrasound imaging and limits the use of clinical echocardiography.

Methods

RF data from short axis systolic and diastolic scans were obtained from 14 open-chest dogs following left-atrial bolus of Optison. Attenuation was induced by interposed silicone pads calibrated to induce 7 dB or 14 dB reductions of the backscattered RF signal. RF images were reconstructed from the RF signals, HFR values calculated for each image pixel for 0 dB, 7 dB and 14 dB attenuation conditions, and LV area obtained by summation of “LV cavity pixels”. A reference LV cavity area was obtained from endocardial border tracings in enhanced scans by experts.

Results

Correlation of the HFR-defined and reference areas at systole was R = 0.95, R = 0.94, and R = 0.91 for 0 dB, 7 dB and 14 dB levels of attenuation, respectively, and at diastole was R = 0.95 for 0 dB, 7 dB and 14 dB levels of attenuation. The mean difference from both systolic and diastolic values was <1.45 cm2 (i.e. negligible) in all attenuation settings.

Conclusion

Our novel HFR method supports precise measurement of the LV cavity area in contrast images with simulated high attenuation of ultrasound signals.  相似文献   

20.

Purpose

The objective of this paper was to automatically segment the cerebellum from T1-weighted human brain magnetic resonance (MR) images.

Materials and Methods

The proposed method constructs a cerebellum template using five sets of 3-T MR imaging (MRI) data, which are used to determine the initial position and the shape prior of the cerebellum for the active contour model. Our formulation includes the active contour model with shape prior, which thereby maintains the shape of the template. The proposed active contour model is sequentially applied to sagittal-, coronal- and transverse-view images. To evaluate the proposed method, it is applied to BrainWeb data and a 3-T MRI data set and compared with FreeSurfer with respect to performance assessment metrics.

Results

The segmented cerebellum was compared with the results from FreeSurfer. Using the manually segmented cerebellum as reference, we measured the average Jaccard coefficients of the proposed method, which were 0.882 and 0.885 for the BrainWeb data and 3-T MRI data set, respectively.

Conclusion

We presented the active contour model with shape prior for extracting the cerebellum from T1-weighted brain MR images. The proposed method yielded a robust and accurate segmentation result.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号