首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive method for the electrochemical determination of synephrine (SYN) by hydrophilic interaction liquid chromatography (HILIC) has been developed. Optimal chromatographic separation and high sensitive determination by HILIC with electrochemical detection (HILIC‐ECD) was achieved using a sulfobetaine‐type zwitterionic monolith column (100×1.02 mm, i.d.), a mixture of 10 mM sodium phosphate (pH 4) and acetonitrile (20 : 80, v/v) as mobile phase, and a glassy carbon working electrode which was applied with a potential at +1.0 V vs. Ag/AgCl. The chromatographic peak height of SYN was proportional to the concentration from 5.0 µg/L to 1.0 mg/L (r=0.999). The detection limit of SYN (S/N=3) was 3.7 pg on the column. Moreover, the present HILIC‐ECD could be applied to the accurate and precise determination of SYN in Aurantii nobilis Pericarpium. In conclusion, we have demonstrated that an ECD is one of useful detection methods applicable to HILIC.  相似文献   

2.
An ion-pair liquid chromatography-electrospray mass spectrometry (LC-ESI-MS) method with in vivo microdialysis for the determination of free-form amphetamine in rat brain has been developed. A microdialysis probe was surgically implanted into the striatum of the rat and artificial cerebrospinal fluid (aCSF) was used as the perfusion medium. Samples were collected and then analyzed off-line by LC-ESI-MS. A reversed phase C18 column was employed for LC separation. Trifluoroacetic acid (TFA) was added in the mobile phase (acetonitrile-water, 10:90, v/v) as an ion-pair reagent. The ion-pair process disguises the protonated amphetamine cations from the ESI-MS electric field as neutral molecules. Post-column addition of volatile organic acid was utilized to minimize TFA signal suppression effect on ESI-MS detection. More than six-fold enhancement of ESI-MS response was achieved by the post-column addition of propionic acid. Good linearity (0.01-1.00 microg/ml, r2 = 0.99) and detection limit (0.002 microg/ml) were determined. Good precision and accuracy were obtained. The applicability of this newly developed method was demonstrated by continuous monitoring of amphetamine concentrations in rat brain after a single 3.0 mg/kg i.p. administration.  相似文献   

3.
Trigonelline is a pyridine alkaloid found in fenugreek seeds and coffee beans. Most of the previous studies are concerned with the quantification of trigonelline along with other constituents in coffee herbs or beverages. Only a few have focused on its determination in animal or human tissues by applying different modes of HPLC with UV or MS detection. The aim of the study was to develop and validate a fast and simple method for trigonelline determination in serum by the use of hydrophilic interaction liquid chromatography (HILIC) with ESI‐MS/MS detection. Separation of trigonelline was achieved on a Kinetex HILIC column operated at 35°C with acetonitrile–ammonium formate (10 mm , pH = 3) buffer mixture (55:45, v/v) as the mobile phase. The developed method was successfully applied to determine trigonelline concentration in mouse serum after intravenous administration of 10 mg/kg. The developed assay is sensitive (limit of detection = 1.5 ng/mL, limit of quantification = 5.0 ng/mL) and linear in a concentration range from 5.0 to 250.0 ng/mL. Sample preparation is limited to deproteinization, centrifugation and filtration. The application of the HILIC mode of chromatography with MS detection and selection of deuterated trigonelline as internal standard allowed a rapid and precise method of trigonelline quantification to be to developed.  相似文献   

4.
An efficient solid phase extraction-spectrofluorimetric method using graphene as adsorbent was developed to sensitively determine glutathione (GSH) in biological samples. Fluorescent probe N-(4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-yl)methyl)iodoacetamide (BODIPY Fl-C1-IA) was applied for the derivatization of GSH. The procedure was based on BODIPY Fl-C1-IA selective reaction with GSH to form highly fluorescent product BODIPY Fl-C1-IA-GSH, its extraction to the graphene-packed SPE cartridge and spectrofluorimetric determination. Some factors affecting the extraction efficiency, such as the type of the eluent and its volume, sample pH, extraction time, and sample volume were optimized. Comparative studies were also performed between graphene and other adsorbents including C18 silica, graphitic carbon, and multi-walled carbon nanotubes for the extraction of analyte. The calibration graph using the pretreatment system for GSH was linear over the range of 0.5-200 nM. The limit of detection was 0.01 nM (signal-to-noise ratio=3). Relative standard deviation for six replicate determinations of GSH at 80 nM concentration level was lower than 5.0%. The developed method was applied to the determination of GSH in human plasma with recoveries of 92-108%. This work revealed the great potentials of graphene as an excellent sorbent material in the analysis of biological samples.  相似文献   

5.
Hydrophilic interaction liquid chromatography (HILIC) method using internal standard for the determination and stability study of ascorbic acid was developed. HILIC method was very fast and simple using the following analytical conditions: ZIC HILIC (150 x 2.1 mm, 3.5 microm) chromatographic column and mobile phase composed of ACN and 50 mM ammonium acetate buffer pH 6.8 (78:22 v/v). Diode array detection was performed and chromatograms were processed at 268 nm, the maximum wavelength of absorbance of ascorbic acid. An extensive stability study of ascorbic acid as a function of various factors including temperature, stabilizing agents, oxygen presence and its concentration in solution was performed in order to gain information about the quantitative influence of individual stability factors. Low temperature and stabilizing agents (o-phosphoric acid and oxalic acid) were found to be key factors enabling substantial enhancement of the stability of ascorbic acid.  相似文献   

6.
A rapid, sensitive and specific high-performance liquid chromatography-electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the first time to determine the concentration of lafutidine in human plasma. After the addition of diazepam (the internal standard, IS) and 1 M sodium hydroxide solution to 0.5-ml plasma sample, lafutidine was extracted from plasma with n-hexane : isopropanol (95 : 5, v/v). The organic layer was evaporated and the residue was redissolved in 200-microl mobile phase. The analyte was chromatographically separated on a prepacked Shimadzu Shim-pack VP-ODS C(18) column (250 x 2.0 mm i.d.) using a mixture of methanol-water (20 mM CH(3)COONH(4)) = 80 : 20 (v/v) as mobile phase. Detection was performed on a single quadrupole mass spectrometer using an electrospray ionization interface and the selected-ion monitoring (SIM) mode. The method showed excellent linearity (r = 0.9993) over the concentration range of 5-400 ng/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation. The limit of detection was 1 ng/ml. The validated LC/ESI-MS method has been successfully applied to the bioequivalence study of lafutidine in 24 healthy male Chinese volunteers.  相似文献   

7.
A method for quantification of the fine particle dose of lactose is described, using a hydrophilic interaction chromatography (HILIC) method and evaporative light scattering detection. The HILIC method used an aminopropyl column and a mobile phase consisting of acetonitril/water (80/20, v/v) for isocratic elution. Sensitive chromatography was obtained using a low concentration of water in the extraction solvent. The detection limit (RSD<10%) at an injection volume of 10 microL is 10 microg/mL. Linearity was obtained in the range of 10-80 microg/mL (R(2)>0.99). A relative standard deviation (RSD) of 0.5% (N=6) demonstrated good precision of the optimized method.  相似文献   

8.
Hydrophilic interaction liquid chromatography (HILIC) was examined for the separation of paralytic shellfish poisoning (PSP) toxins using the stationary phase TSK-gel Amide-80. The parameters tested included type of organic modifier and percentage in the mobile phase, buffer concentration, pH, flow rate and column temperature. Using mass spectrometric (MS) detection, the HILIC column allowed the determination of all the major PSP toxins in one 30 min analysis with a high degree of selectivity and sensitivity. The high percentage of organic modifier in the mobile phase and the omission of ion pairing reagents, both favored in HILIC, provided limits of detection (LOD) in the range 50-100 nM in selected ion monitoring (SIM) mode on a single quadrupole LC-MS system. LOD in selected reaction monitoring (SRM) mode on a sensitive triple quadrupole system were as low as 5-30 nM. Excellent linearity of response was observed.  相似文献   

9.
A method using reversed phase high performance liquid chromatography/electrospray ionization-mass spectrometry (RP-LC/ESI-MS) has been developed to confirm the identity of dansylated derivatives of cysteine (C) and glutathione (GSH), and their respective dimers, cystine (CSSC) and glutathione disulfide (GSSG). Cysteine, GSH, CSSC and GSSG are present at low concentrations in rainbow trout (Oncorhynchus mykiss) liver cells. Initially, hepatic cells were sampled from a suspension culture and disrupted upon addition of 10% perchloric acid. The reduced thiols present in the cell extracts were acetylated to prevent dimerization and then the C and GSH species were derivatized with dansyl chloride for fluorescence detection. An LC system using a weak anion exchange column (AE) with fluorescence detection (FLD) was used for sensitive routine analysis; however, it produced peaks of unknown origin in addition to the expected analytes. Analytes were then separated on a C18 RP-LC system using a water/acetonitrile gradient with 0.2% formic acid, and detected using LC/ESI-MS at 3.5 KV which produced an intense ion with a minimum limit of detection of less than 0.5 pmole injected (>10:1 signal-to-noise (S/N). Subsequently, fractions of effluent from the AE-LC/FLD system were analyzed by LC/ESI-MS to confirm the presence of the target analytes in routine cell extracts. Monodansylated GSSG was identified as a product that could possibly affect the quantification of GSH and GSSG.  相似文献   

10.
张良滔  张立坚  张俊杰  刘春安  蔡春 《色谱》2011,29(4):342-345
建立了亲水作用色谱(HILIC)测定组织中全基因组DNA甲基化水平的方法。采用苯酚-氯仿提取组织中的DNA,提取的DNA用88%甲酸在140 ℃下裂解,经N2吹干后,加乙腈-水(9:1, v/v)溶解,用Waters BEH HILIC柱进行分离,在277 nm波长下检测胞嘧啶(Cyt)及5-甲基胞嘧啶(5-mCyt)含量。结果表明,以乙腈-10 mmol/L甲酸铵溶液(94:6, v/v)为流动相,流速为0.5 mL/min, Cyt与5-mCyt分离较好,保留时间分别为2.6与3.1 min。胞嘧啶的线性范围为1~900 μmol/L,相关系数为0.9999; 5-甲基胞嘧啶的线性范围为1~64 μmol/L,相关系数为0.9998。胞嘧啶和5-甲基胞嘧啶的检出限为54 nmol/L(柱中为0.54 pmol),定量限为250 nmol/L(柱中为2.5 pmol);在5~900 μmol/L的添加水平下,胞嘧啶和5-甲基胞嘧啶的平均加标回收率为94.7%~100.5%,相对标准偏差小于1.48%。用该方法检测了结肠癌组织中DNA甲基化水平,结果显示该癌组织中全基因组的DNA甲基化均值为4.0%。该方法快速、简单,稳定性好,灵敏度较高,能满足全基因组DNA甲基化的检测要求。  相似文献   

11.
亲水作用色谱法测定胡芦巴中的胡芦巴碱   总被引:1,自引:0,他引:1  
卓荣杰  王莉  王龙星  肖红斌  蔡少青 《色谱》2010,28(4):379-382
建立了亲水作用色谱法(HILIC)测定胡芦巴药材中胡芦巴碱含量的方法。采用Waters Atlantis HILIC Silica色谱柱(150 mm×2.1 mm, 3 μm),以乙腈-乙酸铵溶液(pH 4.4)(体积比为70:30)为流动相,流速0.4 mL/min,检测波长265 nm。胡芦巴碱的线性范围为2.50~100 mg/L (r=0.9996);两个加标水平的平均加样回收率为102%,相对标准偏差(RSD)分别为4.17%和2.28%(n=3)。结果表明所建方法分离效果好、快速简易,可以弥补中国药典中离子对色谱法(IPLC)平衡时间过长的缺陷,适用于胡芦巴药材中强极性胡芦巴碱的测定,为胡芦巴的质量控制提供了有效的方法。  相似文献   

12.
The quantitative determination of nucleotides from DNA modified by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liquid chromatography (HPLC). LC/ICP-MS (resolution > 1500 to discriminate against 15N16O+ and 14N16OH+) was employed to determine quantitatively the content of modified nucleotides in standard solutions based on the signal of phosphorus; phosphoric acid served as an internal standard. By means of the standard addition technique the sensitivity of the LC/ESI-MS approach was subsequently determined. Since a comparison of UV, ICP and ESI-MS data suggested that in ESI-MS the ionization efficiency of the adducts is identical within the error limits, quantitative determination of all adducts is possible. For LC/ESI-MS with single ion monitoring, the detection limit for styrene oxide adducts of nucleotides was determined to be 20 pg absolute or 14 modified in 10(8) unmodified nucleotides in a 5 micrograms DNA sample, which comes close to the best methods available for the detection of chemical modifications in DNA.  相似文献   

13.
A novel, sensitive and specific method for the quantitative determination of ivermectin B(1a) in animal plasma using liquid chromatography combined with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is presented. Abamectin was used as the internal standard. Extraction of the samples was performed with a deproteinization step using acetonitrile. Chromatographic separation was achieved on a Nucleosil ODS 5 microm column, using gradient elution with 0.2% (v/v) acetic acid in water and 0.2% (v/v) acetic acid in acetonitrile. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1 and 100 ng ml(-1) showed a good linear correlation (r > or = 0.9989, goodness-of-fit coefficient < or =8.1%). The trueness at 2 and 25 ng ml(-1) (n = 6) was +4.2 and -17.1%, respectively. The trueness and between-run precision for the analysis of quality control samples at 25 ng ml(-1) was -4.0 and 11.0%, respectively (n = 16). The limit of quantification of the method was 1.0 ng ml(-1), for which the trueness and precision also fell within acceptable limits. Using a signal-to-noise ratio of 3 : 1, the limit of detection was calculated to be 0.2 ng ml(-1). The specificity was demonstrated with respect to ivermectin B(1b).The method was successfully used for the quantitative determination of ivermectin B(1a) in plasma samples from treated bovines, demonstrating the usefulness of the developed method for application in the field of pharmacokinetics.  相似文献   

14.
Glutathione (GSH) and glutathione disulfide (GSSG) levels in cells constitute a thiol redox system. They can be used as an indicator of oxidative stress of the cell. In this study, a capillary zone electrophoresis (CZE) method is described that enables quantitation of GSH and GSSG from cellular extracts. The CZE buffer used was 20 mM ammonium acetate containing 5% (v/v) acetic acid at pH 3.1 in conjunction with a polybrene coated capillary operated in reverse polarity mode. Effects of different acids used to prepare cell samples were investigated on CZE performance. The acids include meta phosphoric acid (MPA), trichloroacetic acid (TCA), phosphoric acid (PA) and sulfosalicylic acid (SSA) and are used to stabilize GSH and GSSG before performing CZE analysis. The method features a limit of detection of 4 microM and a limit of quantitation of 12 microM for both GSSG and GSH and recoveries of 94% for GSH and 100% for GSSG. Quantitative analysis of GSSG and GSH in HaCaT cell extracts (5% SSA, w/v) was performed with this method and changes in the ratio of GSH to GSSG in N-ethylmaleimide treated cell sample was observed by comparing with control cell samples.  相似文献   

15.
建立了鸡肉及其制品中利巴韦林和磷酸化利巴韦林代谢物总残留量的亲水作用色谱-串联质谱分析方法(HILIC-MS/MS)。样品采用含1%(v/v)乙酸的乙腈超声提取,于37 ℃条件下以酸性磷酸酶酶解,正己烷除脂后用C18与PSA填料分散固相萃取净化。采用酰胺基超高效亲水作用色谱柱,在乙腈和0.1%甲酸组成的梯度洗脱流动相中分离,在电喷雾正离子电离多反应监测模式下监测,结果表明,样品中利巴韦林残留量在1~200 μg/kg之间时,线性相关系数大于0.999,方法检出限(LOD, S/N≥3)为1 μg/kg,定量限(LOQ, S/N≥10)为5 μg/kg,在3个添加水平下的回收率为67.8%~112.7%,相对标准偏差为6.1%~13.6%。经测定多种实际样品,证明该方法简便、快速、准确,可以满足日常鸡肉及其制品中利巴韦林及其代谢物总残留量的分析要求。  相似文献   

16.
Dencichine (beta-N-oxalyl-L-alpha,beta-diaminopropionic acid) is a haemostatic agent present in important Chinese medicinal herbs such as Panax notoginseng, as well as other Panax species. It is also a reported neurotoxic agent found in Lathyrus sativus (grass pea seed). A selective analytical method incorporating hydrophilic interaction chromatography with positive electrospray ionization tandem mass spectrometry (HILIC/ESI-MS/MS), for the analysis of dencichine in Panax plant species, was developed. Using multiple reaction monitoring (MRM) mode, underivatized dencichine, a small and highly polar compound, was selectively detected and quantified. The contents of dencichine in raw and steamed Panax notoginseng roots, 11 pairs of raw and steamed P. notoginseng herbal products, Panax ginseng roots, and Panax quinquefolium roots, were analyzed and compared. Optimal sensitivity of 0.3 ppm (detection limit) and 1.5 ppm (quantification limit) was achieved. The method was rapid (< or =5 min), with the HILIC peak eluting at about 1 min. Steamed P. notoginseng samples were found to contain less dencichine than the corresponding raw samples, and there were also differences among the three Panax species; raw P. ginseng and P. quinquefolium contained less dencichine than the raw P. notoginseng species. This rapid and specific method may be applied to the quantification of dencichine in complex medicinal plants and their products.  相似文献   

17.
高效液相色谱-蒸发光散射检测法测定蛋黄卵磷脂的含量   总被引:4,自引:0,他引:4  
龚雁  王巧娥  杨屹  丁明玉 《色谱》2006,24(4):373-375
建立了蛋黄磷脂中卵磷脂(即磷脂酰胆碱,PC)的高效液相色谱-蒸发光散射检测(HPLC-ELSD)的测定方法。以Nov a-Pak Silica 60A硅胶柱(3.9 mm i.d.×150 mm,4 μm)为分离柱,正己烷-异丙醇-3%冰醋酸水溶液(体积比为35∶65 ∶8)为流动相,等度洗脱,流速1.0 mL/min,柱温30 ℃。蒸发光散射检测器漂移管温度50 ℃,雾化气(空气)压力350 kPa。在上述条件下测得PC在0.16~1.61 g/L范围内线性关系良好(r2=0.9979),检测限为0.64 μg,方法的精密度为3.2%(n=5),回收率为98.2%~128.2%。将该方法用于实际样品的测定,获得了令人满意的结果。该方 法预处理简单,分析速度快,可用于蛋黄磷脂中卵磷脂的测定。  相似文献   

18.
《Electroanalysis》2006,18(8):741-747
Edge plane pyrolytic graphite electrodes have been applied for the determination of uric acid and ascorbic acid. The separate determination of uric acid was found to produce three linear ranges from 100 nM to 3400 μM with a detection limit of 30 nM found to be possible. Uric acid detection was also explored in the presence of 200 μM ascorbic acid where a detection limit of 52 nM was found to be possible. The detection of ascorbic acid in the presence of uric acid was also explored over three linear ranges of ascorbic acid with a limit of detection of 80 nM. Last the simultaneous determination of both uric acid and ascorbic acid is investigated over the range 100 nM to 1000 μM where detection limits of 50 nM and 120 nM were obtained respectively. Analysis of uric acid in a growth tissue medium was found to be successful, confirming the applicability of the methodology to real matrices. This protocol is shown to provide low detection limits, easy handling (no electrode modification), good voltammetric peak separation of uric acid and ascorbic acid and a wide linear dynamic range.  相似文献   

19.
建立了固相萃取-液相色谱-串联质谱法测定莲蓉馅料中违法添加的二氧化硫脲的分析方法。采用0.05%(v/v)醋酸溶液从馅料中提取二氧化硫脲,经BOND ELUT PLEXA固相萃取柱(60 mg/3 mL)净化,采用Agilent亲水作用色谱柱(100 mm×2.1 mm,3.5 μm)分离,以0.01 mol/L醋酸铵(冰醋酸调pH至3.5)和乙腈为流动相,在多反应监测模式(MRM)下进行定性定量分析。最终,二氧化硫脲在10~1000 μg/L范围内线性关系良好,检出限(LOD)和定量限(LOQ)分别为8.0 μg/kg和30.0 μg/kg,方法回收率为75.3%~80.7%,相对标准偏差(n=6)不超过4.83%。此方法快速、准确、特异性强、灵敏度高、样品前处理方法简便易行,适用于莲蓉馅料中二氧化硫脲的确证与测定。  相似文献   

20.
A selective and sensitive method employing high-performance liquid chromatography-electrospray ionization mass spectrometry was developed and validated for the determination of mitiglinide in human plasma.With gliclazide as the internal standard, mitiglinide was extracted from plasma with n-hexane: = 80 : 20 (v/v). The organic layer was evaporated and the residue was redissolved in methanol: water (10 mM CH3COONH4, pH = 3.0) = 65 : 35 (v/v). An aliquot of 10 microl was chromatographically analyzed on a prepacked Shimadzu VP-ODS (5 microm, 150 x 2.0 mm i.d.) using the mobile phase comprising methanol: water (10 mM CH3COONH4) = 65 : 35 (v/v) by means of selected-ion monitoring mode mass spectrometry. Standard curves were linear (r2 = 0.9972) over the concentration range of 2.84-11 300 pmol/ml and had good accuracy and precision. The within- and between-batch precisions of the method were within 15% of standard deviation. The lower limit of detection was 1.42 pmol/ml. The validated HPLC/ESI-MS method has been successfully applied in the pharmacokinetics of mitiglinide in 12 healthy Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号