首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
A bienzyme biosensor for the simultaneous determination of glucose and fructose was developed by coimmobilising glucose oxidase (GOD), fructose dehydrogenase (FDH), and the mediator, tetrathiafulvalene (TTF), by cross-linking with glutaraldehyde atop a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM) on a gold disk electrode (AuE). The performance of this bienzyme electrode under batch and flow injection (FI) conditions, as well as an amperometric detection in high-performance liquid chromatography (HPLC), are reported. The order of enzyme immobilisation atop the MPA-SAM affected the biosensor amperometric response in terms of sensitivity, with the immobilisation order GOD, FDH, TTF being selected. Similar analytical characteristics to those obtained with single GOD or FDH SAM-based biosensors for glucose and fructose were achieved with the bienzyme electrode, indicating that no noticeable changes in the biosensor responses to the analytes occurred as a consequence of the coimmobilisation of both enzymes on the same MPA-AuE. The suitability of the bienzyme biosensor for the analysis of real samples under flow injection conditions was tested by determining glucose in two certified serum samples. The simultaneous determination of glucose and fructose in the same sample cannot be performed without a separation step because at the detection potential used (+0.10 V), both sugars show amperometric response. Consequently, HPLC with amperometric detection at the TTF-FDH-GOD-MPA-AuE was accomplished. Glucose and fructose were simultaneously determined in honey, cola softdrink, and commercial apple juice, and the results were compared with those obtained by using other reference methods.  相似文献   

2.
 The integration of an urease reactor into a gas diffusion flow injection system was investigated for the determination of urease inhibitors. The enzyme was immobilized by entrapping in polyacrylamide gel. Besides copper and silver ions mercury ions inhibit the conversion of urea to carbon dioxide and ammonia catalysed by urease. The pH change of the carrier solution caused by the ammonia released was measured potentiometrically with a pH electrode. The inhibition behaviour of Hg(II) ions was investigated. A linear range from 2 to 20 μg L-1 Hg(II) was obtained after a 90 s inhibition, with a correlation coefficient of r=0.9997. The relative standard deviation was 1.4% for five measurements of 2 μg L-1Hg(II). A sample frequency of 7 h-1 was achieved. The inhibited enzyme can be reactivated. The method was applied to the determination of Hg(II) in two drinking water samples. Received: 16 April 1996/Revised: 3 June 1996/Accepted: 11 June 1996  相似文献   

3.
A nonenzymatic electrochemical sensor for glucose and fructose was fabricated that contained a glassy carbon electrode modified with a copper oxide (CuO)/multiwalled carbon nanotube (MWCNT) nanocomposite. The electrochemical properties of the CuO/MWCNT‐modified glassy carbon electrode were investigated. Two distinguishable anodic peaks were observed around 0.30 and 0.44 V corresponding to the oxidation of glucose and fructose, respectively, at the surface of the modified electrode. The detection limits for glucose and fructose were both 0.04 mmol/L. The sensor was used to simultaneously determine the concentrations of glucose and fructose in hydrolyzed sucrose samples, and to measure glucose in blood serum samples, demonstrating its potential as a nonenzymatic carbohydrate sensor.  相似文献   

4.
《Analytical letters》2012,45(6):1074-1082
Abstract

Mercury film electrodes consist of a thin film of mercury deposited on an electrode surface (typically glassy carbon) by reduction of a mercury (II) salt in solution. The surface area/volume ratio is larger for the mercury film electrode, and this electrode is more stable than mercury drop electrode, which allows a faster stirring rate to be used in the deposition step. An enzyme electrode is described, based on glucose oxidase immobilized by gelatin and glutaraldehyde and held over a glassy carbon electrode coated with a thin mercury film. This biosensor responds fast and linearly to glucose in a wide concentration range, which is significant because monitoring of glucose levels is a critical component of diabetes care. Certain optimization and characterization studies were carried out. Average value, standard deviation (SD), and variation coefficient (CV) were calculated with the help of the repeatability studies. Finally, glucose content of human blood samples was monitored with the help of the biosensor presented.  相似文献   

5.
Flow injection (FI) and sequential injection (SI) systems with anodic stripping voltammetric detection have been exploited for simultaneous determination of some metals. A pre-plated mercury film on a glassy carbon disc electrode was used as a working electrode in both systems. The same film can be repeatedly applied for at least 50 analysis cycles, thus reducing the mercury consumption and waste. A single line FI voltammetric system using an acetate buffer as a carrier and an electrolyte solution was employed. An injected standard/sample zone was mixed with the buffer in a mixing coil before entering a flow cell. Metal ions were deposited on the working electrode by applying a potential of −1.1 V vs Ag/AgCl reference electrode. The stripping was performed by anodically scanning potential of working electrode to +0.25 V, resulting a voltammogram. Effects of acetate buffer concentration, flow rate and sample volume were investigated. Under the selected condition, detection limits of 1 μg l−1 for Cd(II), 18 μg l−1 for Cu(II), 2 μg l−1 for Pb(II) and 17 μg l−1 for Zn(II) with precisions of 2–5% (n=11) were obtained. The SI voltammetric system was similar to the FI system and using an acetate buffer as a carrier solution. The SI system was operated by a PC via in-house written software and employing an autotitrator as a syringe pump. Standard/sample was aspirated and the zone was then sent to a flow cell for measurement. Detection limits for Cd(II), Cu(II), Pb(II) and Zn(II) were 6, 3, 10 and 470 μg l−1, respectively. Applications to water samples were demonstrated. A homemade UV-digester was used for removing organic matters in the wastewater samples prior to analysis by the proposed voltammetric systems.  相似文献   

6.
1,5-Di-(2-fluorophenyl)-3-mercaptoformazan (F(2)H(2)Dz) immobilized and plasticized with tri-n-butylphosphate (TBP) polyurethane foam (PUF) were found suitable for the detection of mercury(II) and lead(II) in extremely dilute aqueous solutions. In batch mode of extraction with immobilized F(2)H(2)Dz-foam as low as 0.05 and 0.15 mug ml(-1) of mercury(II) and lead(II), respectively were detected and the colored chelates were found more stable over 72 h. Lower concentrations of these metal ions (相似文献   

7.
The possibility of screening the mercury(II) content in real environmental samples based on inhibition of the activity of dissolved invertase has been examined. The extent of inhibition was measured with an amperometric glucose biosensor with glucose oxidase immobilized on a membrane. Data concerning the stability and reproducibility of measurements are provided. The effects of heavy metals on the inhibition of invertase, together with that of common anions such as chloride, nitrate and sulfate are reported. The determination of mercury using this procedure has been carried out in samples of natural and waste water samples of various origins already analyzed by ICP-AES, by spiking ppb levels of mercury(II). Differences in the inhibiting effect of the samples and in the recoveries were found and are discussed.  相似文献   

8.
A 2,4-dinitrophenolate-selective liquid-membrane electrode based on tetrapentylammonium dinitrophenolate dissolved in 2-nitrotoluene is described. The electrode exhibits rapid and near- Nernstian response to the activity of 2,4-dinitrophenolate anions in the range 3×10?5 ?1×10?2 M. The response is unaffected by pH in the range 7.5–12.5. The electrode has been successfully applied to the kinetic potentiometric determination of fructose, glucose and galactose at 60°C and of fructose in the presence of glucose and galactose at 30°C. The electrode can be used for the potentiometric determination of glucose and fructose after completion of the reaction with excess of 2,4-dinitrophenolate ions and of sucrose after acid hydrolysis. Mixtures of glucose, fructose and sucrose in aqueous solutions or honey samples can be determined by the proposed procedures with an average error of about 2%.  相似文献   

9.
Dias Filho NL  do Carmo DR 《Talanta》2006,68(3):919-927
In this work, a hydrophilic clay, Na-montmorillonite from Wyoming, USA, was rendered organophilic by exchanging the inorganic interlayer cations for hexadecyltrimethylammonium ions (HDTA), with the formulae of [(CH3)3N(C16H33)]+ ion. Based on fact that organo-clay has high affinities for non-ionic organic molecules, 1,3,4-thiadiazole-2,5-dithiol was loaded on the HDTA-montmorillonite surface, resulting in the 1,3,4-thiadiazole-2,5-dithiol-HDTA-montmorillonite complex (TDD-organo-clay).The following properties of TDD-organo-clay are discussed: selective adsorption of heavy metal ions measured by batch and chromatographic column techniques, and utilization as preconcentration agent in a chemically modified carbon paste electrode (CMCPE) for determination of mercury(II).The main point of this paper is the construction of a selective sensor, a carbon paste electrode modified with TDD-organo-clay, its properties and its application to the determination of mercury(II) ions, as this element belongs to the most toxic metals. The chemical selectivity of this functional group and the selectivity of voltammetry were combined for preconcentration and determination.  相似文献   

10.
A PVC membrane incorporating p-tert-butyl calix[4]crown with imine units as an ionophore was prepared and used in an ion-selective electrode for the determination of mercury(II) ions. An electrode based on this ionophore showed a good potentiometric response for mercury(II) ions over a wide concentration range of 5.0 x 10(-5) - 1.0 x 10(-1) M with a near-Nernstian slope of 27.3 mV per decade. The detection limit of the electrode was 2.24 x 10(-5) M and the electrode worked well in the pH range of 1.3 - 4.0. The electrode showed a short response time of less than 20 s. The electrode also showed better selectivity for mercury(II) ions over many of the alkali (Na+, -1.69; K+, -1.54), alkaline-earth (Ca2+, -3.30; Ba2+, -3.32), and heavy metal ions (Co2+, -3.67; Ni2+, -3.43; Pb2+, -3.31; Fe3+, -1.82). Ag+ ion was found to be the strongest interfering ion. Also, sharp end points were obtained when the sensor was used as an indicator electrode for the potentiometric titration of mercury(II) ions with iodide and dichromate ions.  相似文献   

11.
A montmorillonite from Wyoming-USA was used to prepare an organo-clay complex, named 2-thiazoline-2-thiol-hexadecyltrimethylammonium-clay (TZT-HDTA-clay), for the purpose of the selective adsorption of the heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). Adsorption isotherms of Hg2+, Pb2+, Cd2+, Cu2+, and Zn2+ from aqueous solutions as a function of the pH were studied at 298 K. Conditions for quantitative retention and elution were established for each metal by batch and column methods. The organo-clay complex was very selective to Hg(II) in aqueous solution in which other metals and ions were also present. The accumulation voltammetry of Hg(II) was studied at a carbon paste electrode chemically modified with this material. The mercury response was evaluated with respect to the pH, electrode composition, preconcentration time, mercury concentration, "cleaning" solution, possible interferences and other variables. A carbon paste electrode modified by TZT-HDTA-clay showed two peaks: one cathodic peak at about 0.0 V and an anodic peak at 0.25 V, scanning the potential from -0.2 to 0.8 V (0.05 M KNO3 vs. Ag/AgCl). The anodic peak at 0.25 V presents excellent selectivity for Hg(II) ions in the presence of foreign ions. The detection limit was estimated as 0.1 microg L(-1). The precision of determination was satisfactory for the respective concentration level.  相似文献   

12.
The influence of Elbe river bacteria isolated from suspended particulate matter (SPM) on dynamic species transformation of mercury was investigated. Experiments were carried out in the presence of bacteria (batch cultures) and in sterile tapwater as a control. For the methylation of inorganic mercury ions by bacteria several cofactors are under discussion. In this work, methylcobalamin, methyl iodide and S-adenosylmethionine were tested as biogenic methyl donors and trimethyl-lead chloride, trimethyltin chloride and dimethylarsenic acid as abiotic methyl donors. Transmethylation reactions as examples of abiotic methyl transfers have higher effectiveness in the formation of methylmercury (CH3Hg+) than methylation with biogenic compounds. This result was observed in batch cultures as well as in sterile water. SPM-bacteria inhibit methyl transfer to mercury(II) ions. This is not only due to passive adsorption processes of mercury(II) to bacterial cell walls; methylmercury is also decomposed very rapidly by SPM-bacteria and is immobilized as mercury(II) by the cells.  相似文献   

13.
A mercury-sensitive chemically modified graphite paste electrode was constructed by incorporating modified silica gel into a conventional graphite paste electrode. The functional group attached to the (3-chloropropyl) silica gel surface was 2-mercaptoimidazole, giving a new product denoted by 3-(2-thioimidazolyl)propyl silica gel, which is able to complex mercury ions. Mercury was chemically adsorbed on the modified graphite paste electrode containing 3-(2-thioimidazolyl)propyl silica (TIPSG GPE) by immersion in a Hg(II) solution, and the resultant surface was characterized by cyclic and differential pulse anodic stripping voltammetry. One cathodic peak at 0.1 V and other anodic peak at 0.34 V were observed on scanning the potential from -0.1 to 0.8 V (0.01 M KNO3; v = 2.0 mV s(-1) vs. Ag/AgCl). The anodic peak at 0.34 V show an excellent sensitivity for Hg(II) ions in the presence of several foreign ions. A calibration graph covering the concentration range from 0.02 to 2 mg L(-1) was obtained. The detection limit was estimated to be 5 microg L(-1). The precision for six determinations of 0.05 and 0.26 mg L(-1) Hg(II) was 3.0 and 2.5% (relative standard deviation), respectively. The method can be used to determine the concentration of mercury(II) in natural waters contaminated by this metal.  相似文献   

14.
Lu TH  Yang HY  Sun IW 《Talanta》1999,49(1):59-68
A Nafion/mercury film electrode (NMFE) was used for the determination of trace thallium(I) in aqueous solutions. Thallium(I) was preconcentrated onto the NMFE from the sample solution containing 0.01 M ethylenediaminetetraacetate (EDTA), and determined by square-wave anodic stripping voltammetry (SWASV). Various factors influencing the determination of thallium(I) were thoroughly investigated. This modified electrode exhibits good resistance to interferences from surface-active compounds. The presence of EDTA effectively eliminated the interferences from metal ions, such as lead(II) and cadmium(II), which are generally considered as the major interferents in the determination of thallium at a mercury electrode. With 2-min preconcentration, linear calibration graphs were obtained over the range 0.05-100 ppb of thallium(I). An even lower detection limit, 0.01 ppb, were achieved with 5-min accumulation. The electrode is easy to prepare and can be readily renewed after each stripping experiment. Applicability of this procedure to various water samples is illustrated.  相似文献   

15.
A simple, highly sensitive and selective carbon nanocomposite electrode has been developed for the electrochemical trace determination of mercury. This mercury nanocomposite sensor was designed by incorporation of thiolated amino acids capped AuNps into the carbon ionic liquid electrode (CILE) which provides remarkably improved sensitivity and selectivity for the electrochemical stripping assay of Hg(II). Mercury ions are expected to interact with amino acids through cooperative metal–ligand interaction to form a stable complex which provides a sensitive approach for electrochemical detection of Hg(II) in the presence of other metal ions. The detection limit was found to be 2.3 nM (S/N = 3) that is lower than the permitted value of Hg(II) reported by the Environmental Protection Agency (EPA) limit of Hg(II) for drinkable water. The proposed nanocomposite electrode exhibits good applicability for monitoring Hg(II) in tap and waste water.  相似文献   

16.
Cobalt ions can be determined in the presence of interfering matrix components such as zinc ions by applying adsorbed surfactants. The influence of different adsorption layers on the reduction processes of both ions was studied. Selective inhibition of the zinc signal was achieved even with an extremely large zinc(II) to cobalt(II) ratio in solutions such as zinc plating baths after modification of the mercury electrode with adsorbed tetrabutylammonium. The influence of additions of dimethylglyoxime and citrate and pH changes on the cobalt signal was investigated.  相似文献   

17.
A novel inhibition-based glucose oxidase (GOx) biosensor for environmental chromium(VI) detection is described. An electropolymerized aniline membrane has been prepared on a platinum electrode containing ferrocene as electron transfer mediator, on which GOx is cross-linked by glutaraldehyde. The mechanism of the redox reaction on the electrode and the performance of the sensor are studied. The sensor's response to glucose decreases when it is inhibited by chromium(VI), with a lower detection limit of 0.49?µg?L?1, and the linear response range is divided into two parts, one of which is 0.49–95.73?µg?L?1 and the other is 95.73?µg?1 to8.05?mg?L?1. The enzyme membrane is shown to be completely reactivated after inhibition, retaining 90% activity over more than forty days. Interference to chromium(VI) determination from lead(II), copper(II), cadmium(II), chromium(III), cobalt(II), tin(II) and nickel(II) is found to be minimal, while high concentrations of mercury(II) and silver(I) may interfere with the determination of trace chromium(VI). The sensor has been used for chromium(VI) determination in soil samples with good results.  相似文献   

18.
The well‐known method for the determination of mercury(II), which is based on the anodic stripping voltammetry of mercury(II), has been adapted for applications at the thin film poly(3‐hexylthiophene) polymer electrode. Halide ions have been found to increase the sensitivity of the mercury response and shift it more positive potentials. This behavior is explained by formation of mercuric halide which can be easily deposited and stripped from the polymer electrode surface. The procedure was optimized for mercury determination. For 120 s accumulation time, detection limit of 5 ng mL?1 mercury(II) has been observed. The relative standard deviation is 1.3% at 40 ng mL?1 mercury(II). The performance of the polymer film studied in this work was evaluated in the presence of surfactants and some potential interfering metal ions such as cadmium, lead, copper and nickel.  相似文献   

19.
《Analytical letters》2012,45(8):1873-1896
Abstract

A flow system incorporating an amperometric glucose oxidase enzyme electrode has been used to study the inhibitory effects of 16 metal cations on glucose oxidase. Only copper(II), mercury(II) and silver(I) caused any significant inhibition. the enzyme electrode could be reactivated by EDTA, the reactivation being most effective for copper(II) and least so for silver(I). Other complexing agents were tried for reactivation but proved to be unsatisfactory.

The ability to reactivate the enzyme on the electrode following copper(II) inhibition, and the linear response of the system to the level of this inhibitor according to I/A = -9.49 × 10?7 log([Cu]/M) + 4.84 × 10?8; r = 0.994 between 2.5 × 10?4M and 5 × 10?3M [Cu]2+ indicates a prospect for the use of a flow system for determining enzyme inhibitors in samples.  相似文献   

20.
The large scale electrolysis of Zn(II), Cd(II), Hg(II), Cu(II), Ni(II), Co(II), Co(III), Fe(II), Mn(II), Cr(II), Cr(III), Bi(III), In(III) and Sb(III) at mercury electrodes in presence of mercaptoacetic acid, 3-mercaptopropionic acid, cysteine and thiourea was carried out and the products were investigated. In case of transition metal ions the catalytic reduction of organic compounds resulting in the formation of sulphide ions was found. There are two possible ways of the production of these ions: (i) consisting in the formation of a complex between transition metal ion and organic ligand which is subsequently, reduced, and (ii) direct electroreduction of organic compound on the electrode modifiied by the deposition of metal and metal sulphide. For both cases the mechanism of electroreduction was discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号