首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The applicability of capillary electrochromatography (CEC) using packed capillary column to enantiomer separations was investigated. As chiral stationary phases, OD type packing materials of 5 and 3 microm particle diameters, originally designed for conventional high-performance liquid chromatography (HPLC) were employed. The chiral packing materials were packed by a pressurized method into a 100 microm I.D. fused-silica capillary. Several racemic enantiomers, such as acidic, neutral and basic drug components, were successfully resolved, typically by using acidic or basic solutions containing acetonitrile as mobile phases. The separation efficiencies for some enantiomers in the chiral CEC system using the 5 microm OD type packing were superior to those obtained in HPLC using chiral packings. The plate heights obtained for several enantiomers were 8-13 microm or the reduced plate height of 1.6-2.6, which indicates the high efficiency of this chiral CEC system.  相似文献   

2.
Enantioseparations of chiral compounds with different structures were studied in non-aqueous capillary electrochromatography (NAQ CEC). Three different polysaccharide derivatives, cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD), amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD) and cellulose tris(4-methylbenzoate) (Chiralcel OJ) were used as chiral stationary phases (CSPs). Methanolic or ethanolic ammonium acetate solutions served as a mobile phase. The effect of the type of the CSP, the loading of the chiral selector on wide-pore aminopropyl derivatized silica gel and operational parameters such as apparent pH, applied voltage, etc. on the EOF and chromatographic characteristics (alpha, N, Rs) were studied. NAQ CEC represents a valuable alternative and an extension to chiral separations by HPLC with common-size columns as well as to capillary LC and CEC in aqueous buffers.  相似文献   

3.
A review is presented on the current state of the art and future trends in the development of sol-gel stationary phases for capillary electrochromatography (CEC). The design and synthesis of stationary phases with prescribed chromatographic and surface charge properties represent challenging tasks in contemporary CEC research. Further developments in CEC as a high-efficiency liquid-phase separation technique will greatly depend on new breakthroughs in the area of stationary phase development. The requirements imposed on CEC stationary phase performance are significantly more demanding compared with those for HPLC. The design of CEC stationary phase must take into consideration the structural characteristics that will provide not only the selective solute/stationary phase interactions leading to chromatographic separations but also the surface charge properties that determine the magnitude and direction of the electroosmotic flow responsible for the mobile phase movement through the CEC column. Therefore, the stationary phase technology in CEC presents a more complex problem than in conventional chromatographic techniques. Different approaches to stationary phase development have been reported in contemporary CEC literature. The sol-gel approach represents a promising direction in this important research. It is applicable to the preparation of CEC stationary phases in different formats: surface coatings, micro/submicro particles, and monolithic beds. Besides, in the sol-gel approach, appropriate sol-gel precursors and other building blocks can be selected to create a stationary phase with desired structural and surface properties. One remarkable advantage of the sol-gel approach is the mild thermal conditions under which the stationary phase synthesis can be carried out (typically at room temperature). It also provides an effective pathway to integrating the advantageous properties of organic and inorganic material systems, and thereby enhancing and fine-tuning chromatographic selectivity of the created hybrid organic-inorganic stationary phases. This review focuses on recent developments in the design, synthesis, characterization, properties, and applications of sol-gel stationary phases in CEC.  相似文献   

4.
Xie C  Fu H  Hu J  Zou H 《Electrophoresis》2004,25(23-24):4095-4109
This review article summarizes the variety of polar stationary phases that have been employed for capillary electrochromatographic separations. Compared with reversed-phase stationary phases, the polar alternatives provide a completely different retention selectivity towards polar and charged analytes. Different types of polar stationary phases are reviewed, including the possible retention mechanisms. Electrochromatographic separations of polar solutes, peptides, and basic pharmaceuticals on polar stationary phases are presented.  相似文献   

5.
The effect of five factors on the capillary electrochromatographic enantioseparation of acidic compounds was studied using an experimental design. The studied factors were pH, acetonitrile content in the mobile phase, temperature, buffer concentration, and applied voltage. These experiments allowed defining a generic separation strategy applicable on acidic compounds with chemical and structural diversity. The starting screening conditions consist of a 45 mM ammonium formate electrolyte at pH 2.9 mixed with 65% acetonitrile, an applied voltage of 15 kV, and a temperature of 25 degrees C. The screening phase occasionally can be followed by an optimization procedure. Evaluation of the proposed strategy pointed out that it allows achieving baseline resolution within a relatively short time when a beginning of separation is obtained at the starting conditions. This strategy revealed enantioselectivity for 11 compounds out of 15, of which 10 could be baseline-separated after the proposed optimization steps.  相似文献   

6.
Hilder EF  Svec F  Fréchet JM 《Electrophoresis》2002,23(22-23):3934-3953
This review summarizes the contributions of a number of groups working in the rapidly growing area of monolithic columns for capillary electrochromatography (CEC), with a focus on those prepared from synthetic polymers. Monoliths have quickly become a well-established stationary phase format in the field of CEC. The simplicity of their in situ preparation method as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. A wide variety of approaches as well as materials used for the preparation of the monolithic stationary phases are detailed. Their excellent chromatographic performance is demonstrated by numerous separations of different analytes.  相似文献   

7.
Synthesis of poly(2-hydroxyethyl methacrylate) (PHEMA) brushes from the inside of silica capillaries by surface-initiated atom transfer radical polymerization (ATRP) yields unique stationary phases for open-tubular capillary electrochromatography (OT-CEC). Although PHEMA brushes have only a small effect on the separation of a set of phenols and anilines, derivatization of PHEMA with ethylenediamine (en) allows baseline resolution of several anilines that co-elute from bare silica capillaries. Derivatization of PHEMA with octanoyl chloride (C8-PHEMA films) affords even better resolution in the separation of a series of phenols and anilines. Increasing the thickness of C8-PHEMA coatings by a factor of 2 enhances resolution for several solute pairs, presumably because of an increase in the effective stationary phase to mobile phase volume ratio. Thus, this work demonstrates that thick polymer brushes provide a tunable stationary phase with a much larger phase ratio than is available from monolayer wall coatings. Through appropriate choice of derivatizing reagents, these polymer brushes should allow separation of a wide range of neutral molecules as well as compounds with similar electrophoretic mobilities.  相似文献   

8.
Qin F  Xie C  Yu Z  Kong L  Ye M  Zou H 《Journal of separation science》2006,29(10):1332-1343
Monolithic materials have become a well-established format for stationary phases in the field of capillary electrochromatography. Four types of monoliths, namely particle-fixed, silica-based, polymer-based, and molecularly imprinted monoliths, have been utilized as enantiomer-selective stationary phases in CEC. This review summarizes recent developments in the area of monolithic enantiomer-selective stationary phases for CEC. The preparative procedure and the characterization of these columns are highlighted. In addition, the disadvantages and limitations of different monolithic enantiomer-selective stationary phases in CEC are briefly discussed.  相似文献   

9.
The potential of methacrylate-based mixed-mode monolithic stationary phases bearing sulfonic acid groups for the separation of positively charged analytes (alkylanilines, amino acids, and peptides) by capillary electrochromatography (CEC) is investigated. The retention mechanism of protonated alkylanilines as positively charged model solutes on these negatively charged mixed-mode stationary phases is investigated by studying the influence of mobile phase and stationary phase parameters on the corrected retention factor which was calculated by taking the electrophoretic mobility of the solutes into consideration. It is shown that both solvophobic and ion-exchange interactions contribute to the retention of these analytes. The dependence of the corrected retention factor on (1) the concentration of the counter ion ammonium and (2) the number of methylene groups in the alkyl chain of the model analytes investigated shows clearly that a one-site model (solvophobic and ion-exchange interactions take place simultaneously at a single type of site) has to be taken to describe the retention behaviour observed. Comparison of the CEC separation of these charged analytes with electrophoretic mobilities determined by open-tubular capillary electrophoresis shows that mainly chromatographic interactions (solvophobic and ion-exchange interactions) are responsible for the selectivity observed in CEC, while the electrophoretic migration of these analytes plays only a minor role.  相似文献   

10.
A new chiral monomer derived from cinchona alkaloid, namely O-9-(tert-butylcarbamoyl)-11-[2-(methacryloyloxy)ethylthio]-10,11-dihydroquinine 1, was employed for the preparation of enantioselective monolithic capillary columns by an in situ copolymerization with 2-hydroxyethyl methacrylate 2 (HEMA), ethylene dimethacrylate 3 (EDMA) in the presence of cyclohexanol and 1-dodecanol as porogens (UV or thermal initiation of azobisisobutyronitrile (AIBN) as radical initiator). The porous properties and the electrochromatographic behavior of the new chiral monoliths were comparatively evaluated with previously described analogs obtained from O-9-[2-(methacryloyloxy)ethylcarbamoyl]-10,11-dihydroquinidine 4 as chiral monomer. Despite close structural and physicochemical similarities of the both chiral monomers, the pore distribution profiles of the resulting monoliths were shifted typically towards larger pore diameters with the new monomer 1. Once more, it was confirmed that a low cross-linking (10 wt% related to total monomers) and a pore diameter of about 1 microm in the dry state provides the best electrochromatographic efficiency as a result of lower resistance to mass transfer (smaller C-term contribution to peak broadening) and more homogeneous flow profile (smaller A-term). Most importantly, as expected the new poly(1-co-HEMA-co-EDMA) monoliths showed enhanced enantioselectivities and in addition faster separations as compared to poly(4-co-HEMA-co-EDMA) analogs, which represents a significant improvement. Further, the elution order was reversed owing to the pseudoenantiomeric behavior of quinine- and quinidine-derived monomers. Fluorescence-labeled 9-fluorenylmethoxycarbonyl (FMOC), dansyl (DNS), 7-dimethylaminosulfonyl-1,3,2-benzoxadiazol-4-yl (DBD), carbazole-9-carbonyl (CC) amino acids could be separated with resolution values between 2 and 4 (with efficiencies typically between 100,000 and 200,000 plates/m) and fluorescence detection (variable wavelength fluorescence detector in-line with UV) yielding routinely a gain in detection sensitivities up to two orders of magnitude without specific optimization of the conditions with regards to fluorescence efficiency.  相似文献   

11.
During the past decade, CEC has been one of the few novel achievements in the field of separation science attracting a wide interest. The technology progress permitted the realization of the long-sought idea to employ an electroosmotically driven flow through the columns improving the separations in terms of both resolution and efficiency. The early practical obstacles related to the use of conventional bead-packed columns have been solved by the introduction of continuous beds, also known as monoliths. Hitherto, various synthesis approaches have been successfully developed producing monolithic beds in situ in capillary columns, sharing similar physical structure built up of tiny particles (in the sub-microm range) that are covalently linked together and to the capillary wall. Parallel with the practical column technology studies, the theory of electrochromatography has been continuously developed, focusing on such basic issues as EOF characterization, separation efficiency, and peak dispersion effects. This review provides a short introduction to the theory of CEC with special attention to monolithic separation beds. The paper also summarizes the latest achievements in CEC and discusses the nomenclature, EOF characteristics, and some specific advantages of monolithic column technology.  相似文献   

12.
Liu Y  Heyden YV  Mangelings D 《Electrophoresis》2012,33(11):1613-1623
Chiral monolithic silica capillary columns were prepared by immobilization of amylose-3,5-dimethylphenylcarbamate (ADMPC) bearing a small fraction of 3-(triethoxysilyl)propyl residues through intermolecular polycondensation of the triethoxysilyl groups. The obtained columns were used for chiral separations in capillary electrochromatography (CEC). The effects of the silica monolith nature and the used chiral selector concentration on the resulting enantiomeric separations were investigated. Fifteen chiral compounds, including acidic, neutral, and basic substances were evaluated and twelve showed partial or baseline separation at some of the different conditions tested. These results demonstrated the promising applicability of ADMPC-immobilized monolithic silica columns in CEC enantioseparations, but also revealed the need for further improvements on the level of baseline separations and efficiencies.  相似文献   

13.
A method is described for the synthesis of rigid, macroporous polymers (monoliths) to be used as stationary phases in capillary electrochromatography (CEC). The procedure reproducibly results in columns with good mechanical and chemical stability. Once the procedure was optimized, it yielded the desired CEC columns in nearly 100% of the cases. The batch-to-batch standard deviation of the migration of the electroosmotic flow (EOF) marker for nine randomly chosen columns was 5%. The polymerization is carried out inside the capillary, an aqueous phase is used as solvent. Monomers based on acrylamides with varying hydrophilicity were used to introduce the interactive moieties together with piperazine diacrylamide as cross-linker and vinylsulfonic acid as provider of the charged, EOF-producing moieties. The pore size of the monoliths was adjusted by adding varying amounts of ammonium sulfate to the reaction mixture. In this manner, the average pore size of a given monolith could be reproducibly adjusted to values ranging from 50 nm to 1.3 microm. The procedure was optimized for four particular types of monoliths, which differed in hydrophobicity. The latter was adjusted by introducing suitable co-monomers, such as alkyl chain-bearing molecules, into the monolithic structure. Attempts to systematically investigate the chromatographic behavior of the monolithic stationary phases were made, using a model mixture of aromatic compounds as sample. The standard deviations for the run-to-run reproducibility of the retention times for unretained and retained analytes were <1.5%. Flat Van Deemter curves were measured even at elevated flow-rates (2 mm/s). Plate heights between 10 and 15 microm were measured in this range. The retention order was taken as the principal indication for the chromatographic mode. The separation was found to be governed neither by pure reversed-phase nor by pure normal-phase chromatography, even on monoliths, where large amounts of C6 ligands had been introduced.  相似文献   

14.
A monolithic stationary phase is the continuous unitary porous structure prepared by in situ polymerization or consolidation inside the column tubing and, if necessary, the surface is functionalized to convert it into a sorbent with the desired chromatographic binding properties [J. Chromatogr. A 855 (1999) 273]. Monolithic stationary phases have attracted considerable attention in liquid chromatography and capillary electrochromatography in recent years due to their simple preparation procedure, unique properties and excellent performance, especially for separation of biopolymers. This review summarizes the preparation, characterization and applications of the monolithic stationary phases. In addition, the disadvantages and limitations of the monolithic stationary phases are also briefly discussed.  相似文献   

15.
A simplified approach to synthesize nonparticulate (continuous or monolithic) beds with embedded vancomycin chiral selectors for capillary electrochromatography is proposed. In the present approach, N,N'-diallyltartardiamide monomer with diol functionality is used, which can be readily converted to aldehyde groups via periodate treatment. Parallel to the activation of the polymeric matrix for covalent attachment of vancomycin, the periodate treatment has shown secondary effects on the polymeric bed morphology, namely the increase of the average pore size and porosity of the skeleton. Inversed size-exclusion chromatography was applied to characterize porosimetric properties of the capillary columns before and after the periodate treatment. Electroosmotic and enantioselective properties of the nonparticulate beds synthesized are presented. The approach is of more general interest attaching different affinity groups to the polymeric matrix and/or enhancing the accessibility to the active sites, for instance, in the molecular imprinting technique.  相似文献   

16.
Liu Z  Wu R  Zou H 《Electrophoresis》2002,23(22-23):3954-3972
This review surveys the recent progress in the adsorbed stationary phases for capillary electrochromatography (CEC). Adsorption-based methods for preparation of stationary phase are novel approaches in CEC, which allow rapid and facile preparing stationary phases with desirable selectivity onto an open-tubular fused-silica capillary, a bare-silica or ion-exchange packed column or a monolithic silica or polymer column. A variety of adsorbing agents have been developed as adsorbed stationary phases, including ionic long-chain surfactant, protein, peptide, amino acid, charged cyclodextrin (CD), basic compound, aliphatic ionene, and ion-exchange latex particle. The adsorbed stationary phases have been applied to separation of neutral, basic and acidic organic compounds, inorganic anions and enantiomers. They have also been applied to on-line sample concentration, fast separation and study of the competitive binding of enantiomers with protein.  相似文献   

17.
Summary Polymerisation of bicontinuous microemulsions yields porous monolithic structures with well defined pore sizes that are potentially suitable for use as stationary phases for capillary electrochromatography (CEC). A variety of pore sizes can be achieved by altering the composition of the microemulsion, which typically consists of butyl methacrylate (BMA) and ethylene glycol dimethacrylate (EGDMA) as the polymerisable oil phase. The aqueous phase consists of water, a surfactant (sodium dodecyl sulphate, SDS) and a co-surfactant (1-propanol). 2-acrylamido-2-methyl-1-propane sulfonic acid (AMPS) is also added to provide charges along the polymer backbone to allow electroosmotic flow (EOF) to occur. SEM analysis shows that in-situ polymerisation yields a monolithic structure with a porous topography. Investigations have shown that these monoliths are easy to prepare, robust and suitable for the separation of phthalates. They generate higher linear velocities than are achieved using the silica based HPLC packings normally used for CEC.  相似文献   

18.
Enantiomeric separations in capillary electrochromatography (CEC) carried out using a continuous-bed chiral stationary phase (CSP) based on the macrocyclic antibiotic, vancomycin, is presented. The continuous beds were prepared from methacryloxypropyl modified fused silica capillaries (100 microm ID) by in situ copolymerization of N-(hydroxymethyl)acrylamide and piperazine diacrylamide with vinyl sulfonic acid comonomer used to introduce ionic functionality and thus a strong electroosmotic flow (EOF). The CSP was subsequently prepared by immobilizing the vancomycin stationary phase by reductive amination. Preliminary results have indicated that an extremely strong EOF is obtained in both the nonaqueous polar organic (15.2 x 10(-5) cm2 V(-1) s(-1) and the aqueous reversed-phase modes of operation (8.5 x 10(-5) cm2 V(-1) s(-1)). Enantioselectivity was obtained for four racemic compounds, the best of which was in the case of thalidomide which was separated in 10 minutes with high resolution (Rs = 2.5) and efficiency (120,000 plates meter(-1)) values.  相似文献   

19.
分子印迹技术在毛细管电色谱中的应用   总被引:2,自引:0,他引:2  
分子印迹技术是制备具有分子识别功能聚合物,即分子印迹聚合物(MIPs)的一种新技术;毛细管电色谱(CEC)是一个具有发展前途的色谱新技术。将分子印迹技术和毛细管电色谱两种新技术相结合,优势互补,具有极大的发展潜力。本文对分子印迹技术在毛细管电色谱中的应用,以及各类MIPs-CEC毛细管柱的制备方法进行了较为全面的综述,引用文献52篇。  相似文献   

20.
Cation exchange type chiral stationary phases (CSPs) based on 3,5-dichlorobenzoyl amino acid and amino phosphonic acid derivatives as chiral selectors (SOs) and silica as chromatographic support were developed and applied to enantiomer separations of chiral bases by nonaqueous capillary electrochromatography (NA-CEC). As a rationale for efficient CSP development we adopted the combined use of the "reciprocity principle of chiral recognition" and nonaqueous ion-pair CE as screening assay. Thus, (S)-atenolol was employed as chiral counter-ion added to the BGE in CE and a series of N-derivatized amino acids and amino phosphonic acids were screened to derive reciprocally information on their chiral recognition abilities for atenolol enantiomers. Two SO candidates, namely N-(3,5-dichlorobenzoyl)-O-allyl-tyrosine and N-(4-allyloxy-3,5-dichlorobenzoyl)-1-amino-3-methylbutane phosphonic acid that have been identified as potential SOs in the CE screening were, after immobilization on thiol-modified silica, evaluated in cation-exchange NA-CEC. The strong chiral cation exchanger with the free phosphonic acid group exhibited enhanced enantioselectivity compared to the weak chiral cation exchanger with the carboxylic acid group. A wide variety of chiral bases could be successfully resolved on the strong chiral cation exchanger with alpha-values up to 2.2 and efficiencies up to 375000 m-1 including beta-blockers and other amino alcohols, local anesthetics like etidocaine, antimalarial agents like mefloquine, Tr?ger's base, phenothiazines like promethazine, and antihistaminics. The influence of several experimental parameters (electrolyte concentration, acid-base ratio and acetonitrile-methanol ratio) was evaluated.  相似文献   