首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
An assay for the quantitative determination of docetaxel in human plasma is described. Docetaxel was extracted from the matrix using liquid-liquid extraction with ter-butylmethylether, followed by high-performance liquid chromatographic analysis using an alkaline eluent. Paclitaxel was used as internal standard. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. The validated range for docetaxel was from 0.25--1000 ng/mL using 200 microL plasma aliquots. The method requires only a limited volume (200 microL) of human plasma and the method can be applied in studies requiring a low lower limit of quantitation of 0.25 ng/mL. The assay was applied successfully in several clinical and pharmacological studies with docetaxel.  相似文献   

2.
The rate at which testosterone is metabolized to different singly hydroxylated metabolites has been widely used as an in vitro marker for activity of different CYP450 enzymes. The interest in extra-hepatic metabolism, e.g. due to metabolism in the gut wall, has increased during the last decade. Measurement of extra-hepatic enzyme activity using testosterone as a substrate requires a highly sensitive analytical method. A new liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) method, using column switching for online cleaning and desalting of samples, was developed and validated for analysis of 2alpha-, 2beta-, 6alpha-, 6beta-, 7alpha-, 16alpha-, and 16beta-hydroxytestosterone and androstenedione. The samples were injected on a SB-CN column and detection was performed using MS/MS. The limits of quantification ranged from 0.3 to 3.33 nM for the different metabolites. The validated method was used to quantify the enzyme activity in rat intestine mucosa. The formation rates of 16alpha-, 16beta-hydroxytestosterone and androstenedione were quantified, and 2beta-and 6beta-hydroxytestosterone were formed above the limits of detection.  相似文献   

3.
Direct quantitation of glutathione S-transferase (GST) isoforms [alpha (GST-A) and micro (GST-M)] in human liver cytosol was achieved by liquid chromatography/tandem mass spectrometry (LC/ESI-MS/MS) analysis of signature peptides of GST-A and GST-M and their corresponding stable isotopic peptide internal standards via multiple reaction monitoring (MRM). The selection of signature peptides was performed via trypsin digestion of commercially available cDNA-expressed GST-A1 and GST-M1, followed by LC/ESI-MS/MS with an ion trap mass spectrometer and sequencing with the TurboSEQUEST application. Quantitative analysis of the selected signature peptides in the multi-reaction monitoring (MRM) mode was performed using a triple-quadruple mass spectrometer. A series of human cytosol samples was quantitatively analyzed for levels of GST-A and GST-M. The total level of GST-A and GST-M obtained from this LC/ESI-MS/MS method was well correlated with the total level of GST determined by the 1-chloro-2,4-dinitrobenzene (CDNB) method.  相似文献   

4.
A rapid, sensitive and selective ion-pair reversed-phase liquid chromatography-electrospray ionization isotope dilution tandem mass spectrometry (IP-LC-ESI-ID-MS/MS) was developed for quantitative analysis of free intracellular metabolites in cell cultures. As an application a group of compounds involved in penicillin biosynthesis pathway of Penicillium chrysogenum cells, such as penicillin G (PenG), 6-aminopenicillanic acid (6-APA), benzylpenicilloic acid (PIO), ortho-hydroxyphenyl acetic acid (o-OH-PAA), phenylacetic acid (PAA), 6-oxopipeidine-2-carboxylic acid (OPC), 8-hydroxypenicillic acid (8-HPA), L-alpha-(delta-aminoadipyl)-L-alpha-cystenyl-D-alpha-valine (ACV) and isopenicillin N (IPN) were chosen. (13)C-labeled analogs of the metabolites were added to the sample solutions as internal standards (I.S.). Sample mixtures were analyzed without any sample pretreatment. No extraction recovery check was needed because I.S. was added to the cell samples before extraction process. The method showed excellent precision (relative standard deviation (RSD)相似文献   

5.
This work presents two liquid chromatography/tandem mass spectrometry (LC/MS/MS) acquisition modes: multiple reaction monitoring (MRM) and neutral loss scan (NL), for the analysis of 28 compounds in a mixture. This mixture includes 21 compounds related to the metabolism of three amino acids: tyrosine, tryptophan and glutamic acid, two pterins and five deuterated compounds used as internal standards. The identification of compounds is achieved using the retention times (RT) and the characteristic fragmentations of ionized compounds. The acquisition modes used for the detection of characteristic ions turned out to be complementary: the identification of expected compounds only is feasible by MRM while expected and unexpected compounds are detected by NL. In the first part of this work, the fragmentations characterizing each molecule of interest are described. These fragmentations are used in the second part for the detection by MRM and NL of selected compounds in mixture with and without biological fluids. Any preliminary extraction precedes the analysis of compounds in biological fluids.  相似文献   

6.
A method for the quantatitive determination of pethidine in human urine by liquid secondary ion and tandem mass spectrometry is presented. Quantification was carried out by using ketamine as internal standard. It was found that the collision-induced dissociation (CID) spectrum of the [M + H]+ ion of pethidine exhibited a prominent daughter ion at m/z 220 and ketamine also yielded the same daughter ion at m/z 220. For ((quadrupole)) quantitative analysis, the first quadrupole mass filter was set to transmit m/z 220 and a narrow-range magnet scan yielded a spectrum of parents, including m/z 238 and 248, correspending to ketamine and pethidine, respectively.  相似文献   

7.
A sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the simultaneous quantitative analysis of dihydrotestosterone (DHT) and testosterone (T) from biological fluids has been developed. Commercially available deuterated analogues were used as internal standards. Steroids were extracted from serum or testicular fluid with hexane/ethyl acetate, evaporated to dryness, and treated with hydroxylamine to form their oxime derivatives. Upon chromatographic separation, the compounds were quantified using selected reaction monitoring (SRM). For T, the [M+H](+) ion at m/z 304 and the fragment ion at m/z 124 were used as the precursor and product ions. For DHT the ion cluster [M+H+ACN](+) at m/z 347 and the dissociated ion [M+H](+) at m/z 306 were used as the precursor and product ions, respectively. The limits of detectability on-column were in the sub-femtomole range for both compounds and the intra-day coefficient of variation (CV) for analysis from serum was less than 7% for both compounds. Given its high reproducibility, sensitivity, and relative simplicity, this assay should be of use in determining androgen levels in biospecimens, particularly in settings where sample quantity or steroid concentration are low.  相似文献   

8.
Acetaminophen (APAP) is a widely used analgesic and antipyretic drug. It is mainly metabolized by phase 1 and 2 reactions in the liver, and thus it could be involved in many drug–drug interactions. Therefore, the study of APAP metabolism is important in toxicological and pharmacokinetic studies. The objective of this study was to develop a rapid and sensitive method for the determination of APAP and its six metabolites in rat plasma for the pharmacokinetic studies. APAP and its metabolites were separated through a Capcell Pak MGII C18 column and quantitated with a 16 min run in a triple‐quadruple mass spectrometer. The mobile phases were composed of 0.1% formic acid in either 95% water or 95% acetonitrile and analysis was performed twice in positive and negative modes. Validations such as accuracy, precision, recovery, matrix effect and stability were found to be within acceptance criteria of validation guidelines, indicating that the assay was applicable to the determination of the plasma concentrations of drug and its six metabolites. In conclusion, we developed an LC‐MS/MS method for the quantitative analysis of APAP and its six metabolites in rat plasma, and this method appears to be useful for pharmacokinetic/toxicokinetic studies of APAP and its metabolites in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
The Lewis x structure [Lex, Galbeta1-4(Fucalpha1-3)GlcNAc] motif is one of the tumor antigens and plays an important role in oncogenesis, development, cellular differentiation and adhesion. The detection of Lex-carbohydrates and their structural analysis are necessary to clarify the role of Lex in several biological events. Mass spectrometry has been preferably used for the structural analysis of carbohydrates. Especially, collision-induced dissociation (CID) tandem mass spectrometry (MS/MS), which causes a glycosidic bond cleavage, is used for carbohydrate sequencing. However, Lex cannot be identified by MS/MS due to the existence of the positional isomers, such as Lewis a [Galbeta1-3(alpha1-4Fuc)GlcNAc]. In the present study, we demonstrate the specific detection of Lex-carbohydrates in a biological sample by using multiple-stage MS/MS (MSn). Using pyridylaminated oligosaccharides bearing Lex, we found that the Lex-motif yields a cross-ring fragment by the cleavage of a bond between C-3 and C-4 of GlcNAc in Gal(Fuc)GlcNAc. The Lex-specific cross-ring fragment ion at m/z 259 was effectively detected by sequential scans, consisting of a full MS1 scan, data-dependent CID MS2 scan, MS3 of [Gal(Fuc)GlcNAc+Na]+ at m/z 534, and MS4 of [GalGlcNAc+Na]+ at m/z 388. The sequential scan was applied to N-linked oligosaccharide profiling using a LC/ESI-MSn system equipped with a graphitized carbon column. We successfully detected the Lex-motif and elucidated the structures of several Lex and Lewis y [(Fucalpha1-2)Galbeta1-4(Fucalpha1-3)GlcNAc] oligosaccharides in the murine kidney used as a model tissue. Our method is expected to be a powerful tool for the specific detection of the Lex-motif, and structural elucidation of Lex-carbohydrates in biological samples.  相似文献   

10.
Liquid chromatography/mass spectrometry (LC/MS)-based proteomics has been used to identify soluble proteins in the bovine adrenal medulla. This gland is a major source of hormones, opioids, neurotransmitters, and several vital proteins. The adrenal medulla proteins were first purified using ammonium sulfate precipitation. The resulting proteins were then pre-fractionated with a C-4 high-performance liquid chromatography (HPLC) column. Each 2-min HPLC fraction was digested with trypsin, and separated further and analyzed using capillary liquid chromatography/tandem mass spectrometry (capLC/nanospray-MS/MS) to map the proteome of the adrenal medulla. The parent mass and sequence ion information thus obtained for tryptic peptides was used to search the NCBInr database using the SEQUEST search engine. A total of 195 proteins were identified, of which 71 had good scores (delta correlation value greater than 0.1, preliminary score above 200, and cross-correlation value above 2.5). The prominent proteins thus identified are secretogranin I precursor, chromogranin A, proenkephalin A precursor, myosin X, hemoglobin beta chain, hemoglobin alpha chain, heat shock protein 10 kDa, and replicase.  相似文献   

11.
A quantitative method was developed for the determination of phosphatidylcholine (PC) species concentration using nanoflow LC-ESI-MS/MS. In this study, a calibration method is developed to determine the effect of PC carbon chain length on MS peak intensity. Using the multiple standard addition method, a relationship between the peak intensities of different PC species from nanoflow LC-MS and carbon chain length is established first using different injection amounts of PC standards. From this relationship, a calibration curve for each carbon chain length can be obtained for the concentration calculation. It was found that the MS peak area of PC species analyzed by nanoflow LC-MS linearly decreased with increased acyl carbon numbers, and that the effect of the degree of acyl chain unsaturation on MS peak intensity was minimized when the injection amount was maintained at less than 1 pmol. The method was applied for the quantitative calculation of 34 PC species from rat liver, which were identified from data-dependent MS/MS analysis during nanoflow LC separation.  相似文献   

12.
Phenibut (3-phenyl-4-aminobutyric acid) is a γ-aminobutyric acid mimetic drug, which is used clinically as a mood elevator and tranquilizer. In the present work, a rapid, selective and sensitive liquid chromatography–tandem mass spectrometry method for quantification of phenibut in biological matrices has been developed. The method is based on protein precipitation with acidic acetonitrile followed by isocratic chromatographic separation using acetonitrile–formic acid (0.1% in water; 8:92, v/v) mobile phase on a reversed-phase column. Detection of the analyte was performed by electrospray ionization mass spectrometry in multiple reaction monitoring mode with the precursor-to-product ion transition m/z 180.3 → m/z 117.2. The calibration curve was linear over the concentration range 50–2000 ng/mL. The lower limit of quantification for phenibut in rat brain extracts was 50 ng/mL. Acceptable precision and accuracy were obtained over the whole concentration range. The validated method was successfully applied in a pharmacological study to analyze phenibut concentration in rat brain tissue extract samples. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
The development of LC-MS/MS instruments and related applications improved the large-scale analyses of proteins and peptides in complex biological mixtures. The historical factor limiting these types of studies was the lack of sensitivity and reproducibility. However, the capacity of these analyses to detect proteins and peptides was significantly enhanced to a point where they are routinely performed in specialized laboratories in support to drug development programs as well as prognostic and diagnostic investigations. The analytical strategy used in peptidomic analyses needs to minimize the fluctuation in data measurements that might mask or reduce the precision of the determinations and consequently reduce the sensitivity of the assay. Inherently, it outlines the importance of careful standardization to reduce technical and instrumental variation. Therefore, this review will focus on the strengths and the limitations of the different experimental approaches used for the integration of internal standards in peptidomic studies. This review will examine a wide variety of methods, reagents, instrumentations and data analysis tools available to design peptidomic experiments. Moreover, this review will focus on the importance of precision and accuracy in order to adequately establish analysis threshold to detect peptide expression differences.  相似文献   

14.
A method for determination of triforine using high-performance liquid chromatography with electrospray tandem mass spectrometry was developed. A simple ethyl acetate extraction with solvent exchange into water/methanol was used for sample preparation. The method was validated at 0.01 and 0.05 mg kg(-1) levels in apple, tomato and tinned blackcurrants. Recoveries were in the range 56.6-99.8% and no matrix suppression or enhancement effects were observed.  相似文献   

15.
The quantitative and confirmative performance of two different mass spectrometry (MS) techniques (high-resolution MS and tandem MS) was critically compared. Evaluated was a new extraction and clean-up protocol which was developed to cover more than 100 different veterinary drugs at trace levels in a number of animal tissues and honey matrices. Both detection techniques, high-resolution mass spectrometry (HRMS) (single-stage Orbitrap instrument operated at 50 000 full width at half maximum) and tandem mass spectrometry (MS/MS) (quadrupole technology) were used to validate the method according to the EU Commission Decision 2002/657/EEC. Equal or even a slightly better quantitative performance was observed for the HRMS-based approach. Sensitivity is higher for unit mass resolution MS/MS if only a subset of the 100 compounds has to be monitored. Confirmation of suspected positive findings can be done by evaluating the intensity ratio between different MS/MS transitions, or by accurate mass based product ion traces (no precursor selection applied). MS/MS relies on compound-specific optimized transitions; hence the second, confirmatory transition generally shows relatively high ion abundance (fragmentation efficacy). This is often not the case in single-stage HRMS, since a generic (not compound-optimized) collision energy is applied. Hence, confirmation of analytes present at low levels is superior when performed by MS/MS. Slightly better precision, but poorer accuracy (fortified matrix extracts versus pure standard solution) of ion ratios were observed when comparing data obtained by HRMS versus MS/MS.  相似文献   

16.
A sensitive, accurate and precise liquid chromatography–tandem mass spectrometry method was developed for the determination of (?)‐satropane (3α‐paramethyl‐benzenesulfonyloxy‐6β‐acetoxy‐tropane) in rabbit aqueous humor. Since (?)‐satropane may be absorbed from the aqueous humour with resultant systemic side effects, the LC‐MS/MS method was also evaluated for its applicability in analyzing plasma samples containing this compound. (?)‐Satropane and phentolamine (the internal standard, represented as IS) were detected by multiple reaction monitoring using the transitions m/z 354–182 and 282–212, respectively. The calibration curve was linear over the ranges 2–500 and 5–1000 ng/mL, and the values of the lower limit of quantification were 2 and 5 ng/mL for the microdialysis dialysate and rat plasma samples, respectively. The intra‐day and inter‐day precision and accuracy were better than 8.6 and 6.00%, respectively, in both matrices investigated. The absolute recovery of the plasma samples was more than 76.30%. The average matrix effects of (?)‐satropane were 91.72 and 83.05% in the microdialysis dialysate and plasma samples, respectively. The validated method was successfully applied to analyze (?)‐satropane in microdialysis dialysate and rat plasma samples, and this assay has been used to quantify (‐)‐satropane in the pharmacokinetic and toxicokinetic studies in our laboratory. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
Two different isotope-dilution liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods for the quantitative determination of folic acid (FA) in multivitamin/multielement tablets are reported. These methods represent distinct improvements in terms of speed and specificity over most existing microbiological and chromatographic methods for the determination of FA in dietary supplements. The first method utilizes an aqueous/organic-based extraction solvent combined with positive-ion mode LC/MS/MS detection of protonated [M + H]+ FA molecules and the second method utilizes a pure aqueous-based extraction solvent combined with negative-ion mode LC/MS/MS detection of deprotonated [M - H]- FA molecules. The LC/MS/MS methods exhibit comparable linear dynamic ranges (> or =3 orders of magnitude), limits of detection (0.02 ng on-column) and limits of quantification (0.06 ng on-column) for FA. Two methods employing different extraction and different MS detection modes were developed to allow method cross-validation. Successful validation of each measurement procedure supports the use of either method for the certification of FA levels in dietary supplements. The accuracy and precision of each measurement procedure were evaluated by applying each method to the quantitative determination of FA in a NIST standard reference material (NIST SRM 3280 multivitamin/multielement tablets). The FA measurement accuracy for both methods was > or =95% (based on the manufacturer's assessment of the FA level in SRM 3280) with corresponding measurement precision values (% RSD) of approximately 1%.  相似文献   

18.
A high-throughput ultrasensitive analytical method based on liquid chromatography with positive ion atmospheric pressure chemical ionization (APCI) coupled to tandem mass spectrometric detection (LC/MS/MS) was developed for the determination of all-trans-4-oxo-retinoic acid (at4oxoRA), 13-cis-4-oxo-retinoic acid (13c4oxoRA), 13-cis-retinoic acid (13cRA), all-trans-retinoic acid (atRA) and all-trans-retinol (atROH) in human plasma. A stable isotope of atRA was used as internal standard (IS). The analytes and IS were isolated from 100 microL plasma by acetonitrile mono-phase extraction (MPE) performed in black 96-well microtiterplates. A 100 microL injection was focused on-column and chromatographed on an Agilent ZORBAX SB-C18 rapid-resolution high-throughput (RRHT) column with 1.8-microm particles (4.6 mmx50 mm) maintained at 60 degrees C. The initial mobile phase composition was acetonitrile/water/formic acid (10:90:0.1, v/v/v) delivered at 1.8 mL/min. Elution was accomplished by a fast gradient to acetonitrile/methanol/formic acid (90:10:0.1, v/v/v). The method had a chromatographic total run time of 7 min. An Applied Biosystems 4000 Q TRAP linear tandem mass spectrometer equipped with a heated nebulizer (APCI) ionization source was operated in multiple reaction monitoring (MRM) mode with the precursor-to-product ion transitions m/z 315.4-->297 (4-oxo-retinoic acids), 301.2-->205 (retinoic acids), 305.0-->209 (IS) and 269.2-->93 (retinol) used for quantification. The assay was fully validated and found to have acceptable accuracy, precision, linearity, sensitivity and selectivity. The mean extraction recoveries from spiked plasma samples were 80-105% for the various retinoids at three different levels. The intra-day accuracy of the assay was within 8% of nominal and intra-day precision was better than 8% coefficient of variance (CV) for retinoic acids. Inter-day precision results for quality control samples run over a 12-day period alongside clinical samples showed mean precision better than 12.5% CV. The limit of quantification was in the range of 0.1-0.2 ng/mL and the mass limit of detection (mLOD) was in the range 1-4 pg on column for the retinoic acids. The assay has been successfully applied to the analysis of 1700 plasma samples.  相似文献   

19.
20.
Current nano-scale liquid chromatography-tandem mass spectrometry (nanoLC-MS/MS) approaches in proteome research are reviewed from an analytical perspective. For comprehensive analysis of cellular proteins, analytical methods with higher resolution, sensitivity, and wider dynamic range are required. Miniaturized LC coupled with tandem mass spectrometry is currently one of the most versatile techniques. In this review, the current status of nanoLC-MS/MS systems as well as data management systems is addressed. In addition, the future prospects for complete proteomics are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏