首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Benzofurazan derivatization reagents, 4‐[2‐(N,N‐dimethylamino)ethylaminosulfonyl]‐7‐(2‐aminopentylamino)‐2,1,3‐benzoxadiazole (DAABD‐AP) and 4‐[2‐(N,N‐dimethylamino) ethylaminosulfonyl]‐7‐(2‐aminobutylamino)‐2,1,3‐benzoxadiazole (DAABD‐AB), for short‐chain carboxylic acids in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) were synthesized. These reagents reacted with short chain carboxylic acids in the presence of the condensation reagents at 60°C for 60 min. The generated derivatives were separated on the reversed‐phase column and detected by ESI‐MS/MS with the detection limits of 0.1–0.12 pmol on column. Upon collision‐induced dissociation, a single and intense product ion at m/z 151 was observed. These results indicated that DAABD‐AP and DAABD‐AB are suitable as the derivatization reagents in LC/ESI‐MS/MS analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
The derivatization regents for carboxylic acids, DAABD-AE (4-[2-(N,N-dimethylamino)ethylaminosulfonyl]7-(2-aminoethylamino)-2,1,3-benzoxadiazole), MePZBD-AE ([4-(4-N-methyl)piperazinosulfonyl]-7-(2-aminoethylamino)-2,1,3-benzoxadiazole) and APZBD-NHMe ([4-(4-N-aminoethyl)piperazinosulfonyl]-7-methylamino-2,1,3-benzoxadiazole) were developed for electrospray ionization-mass spectrometry (ESI-MS). The derivatization reaction with fatty acids was completed at 60 degrees C within 30 min. The derivatives of fatty acids were separated on a reversed-phase column and detected with ESI-MS. The detection limits attained for fatty acids were femtomol range and the calibration curves were linear over the range from 0.1 to 100 pmol (r2 > 0.992) for DAABD-AE and MePZBD-AE. DAABD-NHMe was applied to the analysis of fatty acids in rat plasma samples.  相似文献   

3.
The derivatization reagents for carboxylic acids, N‐(Pyridin‐3‐yl)hydrazinecarbothioamide, N‐[4‐(dimethylamino)phenyl]hydrazinecarbothioamide, 1‐(2‐aminoethyl)‐3‐(pyridin‐3‐yl)thiourea, 1‐(2‐aminoethyl)‐3‐[4‐(dimethylamino)phenyl]thiourea and 4‐(2‐aminoethyl)‐N‐phenylpiperazine‐1‐carbothioamide were synthesized. These reagents reacted with carboxylic acids at 60°C for 45 min in the presence of the condensation reagents. The generated derivatives were favorably separated on the reversed‐phase column and sensitively detected by electrospray ionization tandem mass spectrometry. These reagents enhanced the electrospray ionization response of the analyte and generated a particular product ion efficiently by collision‐induced dissociation, and thus they were suitable for MS/MS detection. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
The applicability of 3‐pyridyl isothiocyanate, p‐(dimethylamino)phenyl isothiocyanate and m‐nitrophenyl isothiocyanate as the derivatization reagents for amines in high‐performance liquid chromatography/electrospray ionization–tandem mass spectrometry (LC/ESI‐MS/MS) was examined. The generated derivatives of amines with these reagents were favorably separated on the reversed‐phase column and detected by ESI‐MS/MS. The C–N bond of the generated thiourea structure was efficiently cleaved by collision‐induced dissociation and gave the single and intense product ion. Among the three reagents, 3‐pyridyl isothiocyanate was the most suitable as the derivatization reagent with regard to the reactivity to amines and the detection sensitivity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
Benzofurazan derivatization reagent, 4-[2-(N,N-dimethylamino)ethylaminosulfonyl]-7-N-methylhydrazino-2,1,3-benzoxadiazole (DAABD-MHz), for aldehydes in liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS), was synthesized. DAABD-MHz reacted with aliphatic aldehydes under mild conditions. The generated derivatives were separated on a reversed-phase column and detected by ESI-MS/MS with detection limits of 30-60 fmol on-column. Upon collision-induced dissociation, a single and intense fragment ion at m/z 151 was observed. These results suggested that DAABD-MHz was suitable as a derivatization reagent in LC/ESI-MS/MS.  相似文献   

6.
An automated method for high‐throughput amino acid analysis, using precolumn derivatization high‐performance liquid chromatography/electrospray mass spectrometry (HPLC/ESI‐MS), was developed and evaluated. The precolumn derivatization step was performed in the reaction port of a home‐built auto‐sampler system. Amino acids were derivatized with 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate, and a 3 μm Wakosil‐II 3C8‐100HG column (100 × 2.1 mm i.d.) was used for separation. To achieve a 13 min cycle for each sample, the derivatization and separation steps were performed in parallel. The results of the method evaluation, including the linearity, and the intra‐ and inter‐precision, were sufficient to measure physiological amino acids in human plasma samples. The relative standard deviations of typical amino acids in actual human plasma samples were below 10%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methanol, 1 ml each) and cut (1-2 mm) material, 700 microl of water, 20 microl of internal standard solution (pentadeuterated EtG, D(5)-EtG, 500 microg/l) and 20 microl of methanol were added. Samples were incubated at 25 degrees C overnight and then ultrasonicated for 2 h. Finally, 8 microl of the centrifuged solution (13,000 rpm) were analyzed by LC/ESI-MS/MS in negative ion mode. The surviving ions of EtG and D(5)-EtG were monitored together with the following MRM transitions: m/z 221 --> 75, m/z 221 --> 85 (EtG) and m/z 226 --> 75, m/z 226 --> 85 (D(5)-EtG). The method exhibited a mean correlation coefficient better than 0.9998 over the dynamic range (3-2000 pg/mg). The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 3 and 2 pg/mg respectively. The intra- and interday precision and accuracy were studied at four different concentration levels (3, 5, 56 and 160 pg/mg) and were always better than 7% (n = 5). Matrix effects did not exceed 20%. The method was applied to several hair samples taken from autopsies of known alcoholics, from patients in withdrawal treatment, from social drinkers, from adult teetotalers and from children not exposed to ethanol, with EtG concentrations globally ranging from < or =2 to 4180 pg/mg.  相似文献   

8.
The combined use of a so-called internal standard and the isotope-labeled derivatization reagent for the quantification of analytes for liquid chromatography-mass spectrometry (LC/MS) was further studied. The sample solution (containing the analytes and an internal standard) was derivatized with the light form of the derivatization reagent, 7-(N,N-dimethylaminosulfonyl)-4-(aminoethyl)piperazino-2,1,3-benzoxadiazole (DBD-PZ-NH(2)) or 7-(N,N-dimethylaminosulfonyl)-4-piperazino-2,1,3-benzoxadiazole (DBD-PZ). A standard solution of the analytes (containing an internal standard) was derivatized with the isotope (d(6))-labeled derivatization reagent, DBD-PZ-NH(2) (D) or DBD-PZ (D), and served as the isotope-labeled internal standards. The peak heights of the targeted analytes derivatives in the sample solution were corrected using those of the internal standard and the heavy form derivatives of the standards, and the calibration curves were constructed. The curve bending of the calibration curves caused by the ion suppression at the ion source was suppressed and the linear dynamic ranges of the calibration curves were expanded. The derivatives of DBD-PZ-NH(2) were about 10 times more sensitively detected than those of DBD-PZ derivatives and, therefore, DBD-PZ-NH(2) might be suitable for sensitive detection.  相似文献   

9.
A novel method of amino acid analysis using derivatization of multiple functional groups (amino, carboxyl, and phenolic hydroxyl groups) was applied to measure glycated amino acids in order to quantify glycated peptides and evaluate the degree of glycation of peptide. Amino and carboxyl groups of amino acids were derivatized with 1‐bromobutane so that the hydrophobicities and basicities of the amino acids, including glycated amino acids, were improved. These derivatized amino acids could be detected with high sensitivity using LC‐MS/MS. In this study, 1‐deoxyfructosyl‐VHLTPE and VHLTPE, which are N‐terminal peptides of the β‐chains of hemoglobin, were selected as target compounds. After reducing the peptide sample solution with sodium borohydride, the obtained peptides were hydrolyzed with hydrochloric acid. The released amino acids were then derivatized with 1‐bromobutane and analyzed with LC‐MS/MS. The derivatized amino acids, including glycated amino acids, could be separated using an octadecyl silylated silica column and good sharp peaks were detected. We show a confirmatory experiment that the proposed method can be applied to evaluate the degree of glycation of peptides, using mixtures of glycated and non‐glycated peptide. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
V‐nerve agents present information‐poor spectra, both in GC‐EI‐MS and LC‐ESI‐MS/MS, with dominant fragments/product ions corresponding to the amine‐containing residue. Hence, derivatives/isomers with the same amine residue exhibit similar mass spectral patterns, leading to ambiguity in the phosphonate structure. We present a simple approach for their structural elucidation based on two complementary experiments: ESI‐MS/MS of the original compound, which provides information about the amine moiety, and ESI‐MS/MS of the phosphonic acid hydrolysis products generated by N‐iodosuccinimide, which provides ions' characteristic of the phosphonate structure. This approach enables the structural elucidation of the original V‐agents with a higher degree of certainty.  相似文献   

11.
Stable isotope‐coding coupled with mass spectrometry is a popular method for quantitative proteomics and peptide quantification. However, the efficiency of the derivatization reaction at a particular functional group, especially in complex structures, can affect accuracy. Here, we present a dual functional‐group derivatization of bioactive peptides followed by micro liquid chromatography‐tandem mass spectrometry (LC‐MS/MS). By separating the sensitivity‐enhancement and isotope‐coding derivatization reactions, suitable chemistries can be chosen. The peptide amino groups were reductively alkylated with acetaldehyde or acetaldehyde‐d4 to afford N‐alkylated products with different masses. This process is simple, quick and high‐yield, and accurate comparative analysis can be achieved for the mass‐differentiated peptides. Then, the carboxyl groups were derivatized with 1‐(2‐pyrimidinyl)piperazine to increase MS/MS sensitivity. Angiotensins I–IV, bradykinin and neurotensin were analyzed after online solid phase extraction by micro LC‐MS/MS. In all instances, a greater than 17‐fold increase in sensitivity was achieved, compared with the analyses of the underivatized peptides. Furthermore, the values obtained from the present method were in agreement with the result from isotope dilution quantification using isotopically labeled angiotensin I [Asp‐Arg‐(Val‐d8)‐Tyr‐Ile‐His‐Pro‐(Phe‐d8)‐His‐Leu]. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration.  相似文献   

13.
The aim of the present study was to develop a liquid chromatography/electrospray ionization tandem mass spectrometry (LC–ESI–MS/MS) method for the determination of olaparib in rat plasma. The plasma samples were processed using one-step protein precipitation with acetonitrile and then separated on Waters Acquity BEH C18 column (50 × 2.1 mm, particle size 1.7 μm) using water containing 0.1% formic acid and acetonitrile as mobile phase with optimized gradient elution. Mass spectrometric detection was carried out by selective reaction monitoring mode via positive ESI mode with precursor-to-product transitions of m/z 435.3 > 367.1 and m/z 443.1 > 375.2 for olaparib and 2H8-olaparib (internal standard). The method was linear over the concentration range 0.1–2000 ng/ml with correlation coefficient >0.9987. The lower limit of quantitation was 0.1 ng/ml. The method showed excellent accuracy and precision, negligible matrix effect and high extraction recovery. The validated method was subsequently utilized to determine the concentration of olaparib in rat plasma and further applied to the pharmacokinetic study of olaparib in rat plasma. Our results demonstrated that olaparib showed gender-dependent pharmacokinetics in rats. Compared with that in males, olaparib showed high plasma exposure, long half-life, low clearance and high bioavailability in females.  相似文献   

14.
A rapid, sensitive and specific high-performance liquid chromatography/electrospray ionization mass spectrometric (LC-ESI-MS) method was developed and validated for the quantification of madecassoside, a major active constituent of Centella asiatica (L.) Urb. herbs, in rat plasma. With paeoniflorin as an internal standard (IS), a simple liquid-liquid extraction process was employed for the plasma sample preparation. Chromatographic separation was achieved within 6 min on a Shim-pack CLC-ODS column using acetonitrile and water (60:40, v/v) containing 0.1% (v/v) formic acid as the mobile phase. The detection was performed by MS with electrospray ionization interface in negative selected ion monitoring (SIM) mode. The linear range was 11-5500 ng/mL with the square regression coefficient (r(2) ) of 0.9995. The lower limit of quantification was 11 ng/mL. The intra- and inter- day precision ranged from 4.99 to 9.03%, and the accuracy was between 95.82 and 111.80%. The average recoveries of madecassoside and IS from spiked plasma samples were >92%. The developed method was successfully applied to the pharmacokinetic study of madecassoside in rats after an oral administration.  相似文献   

15.
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
A liquid chromatographic/tandem mass spectrometric method using pneumatically assisted electrospray ionization (LC-ESI-MS/MS) was developed for determination of N-acetylneuramic acid and N-glycolylneuramic acid in infant formula. Reconstituted samples were hydrolysed in dilute sulfuric acid and deproteinized with acetonitrile. The extract was analysed directly without further clean-up by hydrophilic interaction chromatography. The substances were detected in negative ion mode and matrix matched standards were used for calibration. The relative intra-laboratory reproducibility standard deviation was better than 6% for both substances. An R2 of 0.985 was obtained by comparison with a classical colorimetric assay based on reaction with resorcinol. The developed method is expected to be applied for accurate routine analysis of infant formulas.  相似文献   

17.
The enantiomneric separation and the detection of 2-arylpropionic acids after derivatization with the fluorescent reagents with a benzofurazan structure, ( S )-(+)-4-( N,N -dimethylaminosulphonyl)-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole (( S )-DBD-Apy), (R)-(-)-4-nitro-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole (( R )-NBD-Apy), 4- N,N -dimethylaminosulphonyl-7-piperazino-2,1,3-benzoxadiazole (DBD-PZ) and N -hydrazinoformylmethyl- N -methylamino-4,4- N,N -dimethylaminosulphonyl-2,1,3-benzoxadiazole (DBD-CO-Hz) by high-performance liquid chromatography (HPLC) and electrospray ionization mass spectrometry (ESI-MS) were examined. The diastereomeric derivatization with ( S )-DBD-Apy or ( R )-NBD-Apy and the separation on the reversed phase column afforded the high sensitivity. The separation on chiral stationary phase after non-chiral derivatization with DBD-PZ or DBD-CO-Hz provided less sensitivity. The signal-to-noise ratio of ( S )-DBD-Apy-( S )-ketoprofen of 200:1 was observed for 12.5 picomole (pmol) injection and selected ion monitoring (SIM) of the quasi-molecular ion after splitting 1:7 before entering into the electrospray ion sources. As a result, the usefulness of these reagents for MS detection has been demonstrated. © 1998 John Wiley & Sons, Ltd.  相似文献   

18.
The fragmentation reactions of N‐monoalkyloxyphosphoryl amino acids (N‐MAP‐AAs) were studied by electrospray ionization tandem mass spectrometry (ESI‐MS). The sodiated cyclic acylphosphoramidates (CAPAs) were formed through a characteristic pentacoordinate phosphate participated rearrangement reaction in the positive‐ion ESI‐MS/MS and HR‐MS/MS of N‐MAP‐AAs, in which the fragmentation patterns were clearly different from those observed in the corresponding ESI‐MS/MS of N‐dialkyloxyphosphoryl amino acids/peptides and N‐phosphono amino acids. The formation of CAPAs depended on the chemical structures of N‐terminal phosphoryl groups, such as alkyloxy group, negative charge and alkali metal ion. A possible integrated rearrangement mechanism for both PN to PO phosphoryl group migration and formation of CAPAs was proposed. The fragmentation patterns of CAPAs as novel intermediates in gas phase were also investigated. In addition, it was found that the formation of α‐amino acid CAPAs was more favorable than β‐ or γ‐CAPAs in gas phase, which was consistent with previous solution‐phase experiments. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Chemical derivatization is often used to enhance the detectability of the target compounds and to improve the separation efficiency in high-performance liquid chromatography (HPLC). In this review, we describe the recent progress in the development of derivatization reagents having a benzofurazan structure, namely, the fluorogenic reagents, water-soluble reagents, reagents for the analysis of peptides and proteins, and reagents for mass spectrometric detection. The application of these reagents to bio-samples is also briefly described.  相似文献   

20.
A simple and practical derivatization procedure for increasing the detectability and enantiomeric separation of chiral carboxylic acids in LC/ESI‐MS/MS has been developed. (S)‐Anabasine (ANA) was used as the derivatization reagent and rapidly reacted with carboxylic acids [3‐hydroxypalmitic acid (3‐OH‐PA), 2‐(β‐carboxyethyl)‐6‐hydroxy‐2,7,8‐trimethylchroman (γ‐CEHC), and etodolac] in the presence of 4‐(4,6‐dimethoxy‐1,3,5‐triazin‐2‐yl)‐4‐methylmorpholium chloride. The resulting ANA‐derivatives were highly responsive in ESI‐MS operating in the positive‐ion mode and gave characteristic product ions during MS/MS, which enabled sensitive detection using selected reaction monitoring; the detection responses of the ANA‐derivatives were increased by 20–160‐fold over those of the intact carboxylic acids and the limits of detection were in the low femtomole range (1.8–11 fmol on the column). The ANA‐derivatization was also effective for the enatiomeric separation of the chiral carboxylic acids; the resolution was 1.92, 1.75, and 2.03 for 3‐OH‐PA, γ‐CHEC, and etodolac, respectively. The derivatization procedure was successfully applied to a biological sample analysis; the derivatization followed by LC/ESI‐MS/MS enabled the separation and detection of trace amounts of 3‐OH‐PA in neonatal dried blood spot and γ‐CEHC in human saliva with a simple pretreatment and small sample volume.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号