 共查询到20条相似文献,搜索用时 130 毫秒
1.
The purpose of this study is to evaluate the ability of proton density (PD)-BLADE sequences in reducing or even eliminating motion and pulsatile flow artifacts in knee magnetic resonance imaging examinations. Eighty consecutive patients, who had been routinely scanned for knee examination, participated in the study. The following pairs of sequences with and without BLADE were compared: (a) PD turbo spin echo (TSE) sagittal (SAG) fat saturation (FS) in 35 patients, (b) PD TSE coronal (COR) FS in 19 patients, (c) T2 TSE axial in 13 patients and (d) PD TSE SAG in 13 patients. Both qualitative and quantitative analyses were performed based on the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures of normal anatomic structures. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion and pulsation artifacts was evaluated. Based on the results of the SNR, CRN and ReCon for the different sequences and anatomical structures, the BLADE sequences were significantly superior in 19 cases, whereas the corresponding conventional sequences were significantly superior in only 6 cases. BLADE sequences eliminated motion artifacts in all the cases. However, motion artifacts were shown in (a) six PD TSE SAG FS, (b) three PD TSE COR FS, (c) three PD TSE SAG and (d) two T2 TSE axial conventional sequences. In our results, it was found that, in PD FS sequences (sagittal and coronal), the differences between the BLADE and conventional sequences regarding the elimination of motion and pulsatile flow artifacts were statistically significant. In all the comparisons, the PD FS BLADE sequences (coronal and sagittal) were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable to potentially eliminate motion and pulsatile flow artifacts in MR images.  相似文献   

2.
在一定幅度范围内,导航回波可有效追踪刚体运动,用于矫正k空间数据,从而降低运动伪影对图像质量的影响.然而导航回波技术无法很好地矫正大幅度运动以及非刚体运动导致的图像伪影,运动时刻采集到的k空间数据只能舍弃.压缩感知通过非线性规划法,对欠采样数据进行重建,能恢复出原始信号.该文采用伪随机的方式进行数据采集,结合导航回波技术,用压缩感知对未受运动影响的数据进行图像重建,从而减少运动伪影对图像的干扰.该研究为运动伪影的矫正提供了一种新思路.  相似文献   

3.
The purpose of this study is to evaluate the ability of T2 turbo spin echo (TSE) axial and sagittal BLADE sequences in reducing or even eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MRI examinations. Forty four patients, who had routinely undergone a lumbar spine examination, participated in the study. The following pairs of sequences with and without BLADE were compared: a) T2 TSE Sagittal (SAG) in thirty two cases, and b) T2 TSE Axial (AX) also in thirty two cases. Both quantitative and qualitative analyses were performed based on measurements in different normal anatomical structures and examination of seven characteristics, respectively. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion, pulsatile flow and cross-talk artifacts was evaluated. Based on the results of the qualitative analysis for the different sequences and anatomical structures, the BLADE sequences were found to be significantly superior to the conventional ones in all the cases. The BLADE sequences eliminated the motion artifacts in all the cases. In our results, it was found that in the examined sequences (sagittal and axial) the differences between the BLADE and conventional sequences regarding the elimination of motion, pulsatile flow and cross-talk artifacts were statistically significant. In all the comparisons, the T2 TSE BLADE sequences were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable of potentially eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MR images and producing high quality images in collaborative and non-collaborative patients.  相似文献   

4.
An open permanent magnet system with vertical B0 field and without self-shielding can be quite susceptible to perturbations from external magnetic sources. B0 variation in such a system located close to a subway station was measured to be greater than 0.7 μT by both MRI and a fluxgate magnetometer. This B0 variation caused image artifacts. A navigator echo approach that monitored and compensated the view-to-view variation in magnetic resonance signal phase was developed to correct for image artifacts. Human brain imaging experiments using a multislice gradient-echo sequence demonstrated that the ghosting and blurring artifacts associated with B0 variations were effectively removed using the navigator method.  相似文献   

5.

Purpose

To investigate the relationship between estimated glomerular filtration rate (eGFR) and parameters calculated using intravoxel incoherent motion (IVIM) imaging of the kidneys.

Materials and Methods

We studied 365 patients, divided into 4 groups based on eGFR levels (mL/min/1.73 m2): group 1, eGFR ≥ 80(n = 80); group 2, eGFR 60–80 (n = 156); group 3, eGFR 30–60 (n = 114); and group 4 ,eGFR < 30 (n = 15). IVIM imaging was used to acquire diffusion-weighted images at 12 b values. The diffusion coefficient of pure molecular diffusion (D), the diffusion coefficient of microcirculation or perfusion (D*), and perfusion fraction (f) were compared among the groups using group 1 as control.

Results

In the renal cortex, D* values were significantly lower in groups 2, 3, and 4 than in group 1. The D value of renal cortex was significantly low in only group 3. In the renal medulla, the D* and D values were significantly lower only in groups 2 and 3, respectively.

Conclusion

As renal dysfunction progresses, renal perfusion might be reduced earlier and affected more than molecular diffusion in the renal cortex. These changes are effectively detected by IVIM MR imaging.  相似文献   

6.

Purpose

We evaluated the ability of diffusion-weighted imaging (DWI) to detect bone metastasis by comparing the results obtained using this modality with those obtained using 11C-methionine (MET) positron emission tomography (PET) and bone scintigraphy.

Materials and methods

This retrospective study involved 29 patients with bone metastasis. DWI was obtained using a single-shot echo planar imaging (EPI) sequence with fat suppression using a short inversion time inversion recovery sequence. The detection capabilities of DWI for bone metastases were compared with those of whole body MET PET (in 19 patients) and 99mTc-methylene diphosphonate bone scintigraphy (in 15 patients).

Results

Among the 19 patients who were diagnosed using DWI and PET, the PET identified 39 bone metastases, while the DWI identified 60 metastases out of 69 metastases revealed with conventional magnetic resonance imaging (MRI). Among the 15 patients who were diagnosed using DWI and bone scintigraphy, the bone scintigraphy identified 18 bone metastases, while the DWI identified 72 metastases out of 78 metastases revealed with conventional MRI. The overall bone metastasis detection rates were 56.5% for PET, 23.1% for bone scintigraphy and 92.3% for DWI.

Conclusion

DWI is a very sensitive method for detecting bone metastasis and is superior to MET PET and bone scintigraphy in terms of its detection capabilities.  相似文献   

7.
The purpose of this study is to compare two types of sequences in brain magnetic resonance (MR) examinations of uncooperative and cooperative patients. For each group of patients, the pairs of sequences that were compared were two T2-weighted (T2-W) fluid attenuated inversion recovery sequences with different k-space trajectories (conventional Cartesian and BLADE) and two T2-TSE weighted with different k-space trajectories (conventional Cartesian and BLADE). Twenty-three consecutive uncooperative patients and 44 cooperative patients, who routinely underwent brain MR imaging examination, participated in the study. Both qualitative and quantitative analyses were performed based on the signal-to-noise ratio, contrast-to-noise ratio (CNR), and relative contrast (ReCon) measures of normal anatomic structures. The qualitative analysis was performed by experienced radiologists. Also, the presence of motion, other (e.g., Gibbs, susceptibility artifacts, phase encoding from vessels) artifacts and pulsatile flow artifacts was evaluated.  相似文献   

8.
Pulsed field gradient (PFG) NMR is applied to investigate flow processes. In this case the NMR signal experiences phase modulation due to flow and signal attenuation due to the distribution of velocities. The velocity distribution consists of one part originating from diffusion and of a second part, the distribution of the directed motion. The usual PFG-experiment in which the gradient strength is incremented cannot distinguish between both. Incrementing velocity at constant gradient strength keeps the contribution from diffusion constant but changes the absolute width of the velocity distribution. So the signal is attenuated again, but only due to the distribution of the directed motion. The phase modulation as a signature of flow is not affected by this strategy, because velocity and gradient strength are Fourier conjugated. The key advantage of this approach is the possibility of measuring very low velocities, which only cause a very slight phase modulation that is easily covered by diffusion. The method is discussed here for very slow flow in a rheometer cell.  相似文献   

9.
The theory of diffusion gradient-weighted MRI (DGWI) is presented in this paper. The Bloch-Torrey equation was modified to include the effect of intravoxel spatial-location variation of water diffusion (diffusion gradient) on MRI signal, in addition to the effect of intravoxel spatial-direction variation of water diffusion (diffusion anisotropy). An analytical solution for a diffusion-encoding spin-echo pulse sequence was derived. Unlike water diffusion which attenuates the image signal intensity, this newly derived solution relates the spatial gradient of the water diffusion with the phase of the image signal. This novel MRI technique directly measures both the water diffusion and its spatial gradient, and thus offers a noninvasive imaging tool to simultaneously investigate the intravoxel inhomogeneity and anisotropy of tissue structures. In addition, as demonstrated with our preliminary data, this new method may be utilized to delineate the interfaces of tissues with different diffusion. This method is an extension of the successful diffusion tensor MRI (DTI), but requires no additional data acquisition. In addition to the measured diffusion tensor, this new method provides measurements of the spatial derivatives of the three principal diffusivities of the tensor, thereby providing additional information for improving white matter fiber tractography.  相似文献   

10.
Systems where resource availability approaches a critical threshold are common to many engineering and scientific applications and often necessitate the estimation of first passage time statistics of a Brownian motion (Bm) driven by time-dependent drift and diffusion coefficients. Modeling such systems requires solving the associated Fokker-Planck equation subject to an absorbing barrier. Transitional probabilities are derived via the method of images, whose applicability to time dependent problems is shown to be limited to state-independent drift and diffusion coefficients that only depend on time and are proportional to each other. First passage time statistics, such as the survival probabilities and first passage time densities are obtained analytically. The analysis includes the study of different functional forms of the time dependent drift and diffusion, including power-law time dependence and different periodic drivers. As a case study of these theoretical results, a stochastic model of water resources availability in snowmelt dominated regions is presented, where both temperature effects and snow-precipitation input are incorporated.  相似文献   

11.
This paper presents a summary of unique highly nonlinear static and dynamic theories for chain molecules (actually, for almost any kind of organic molecule), including the first superstrong polymers. These theories have been used to predict and explain (1) the physical self-assembly (self-ordering) of specific kinds of molecules into liquid crystalline (LC) phases (i.e., partially ordered phases) and (2) the diffusion of these molecules in various LC phases and the isotropic (I) liquid phase.By acceptance of this article, the publisher recognizes that the U. S. Government retains a nonexclusive, royality-free license to publish or reproduce the published form of this contribution, or to allow others to do so, for U.S. Government purposes.  相似文献   

12.
We evaluated two methods for correcting inhomogeneity-induced signal losses in magnetic resonance gradient-echo imaging that either use gradient compensation or simply acquire thin sections. The strategies were tested in the human brain in terms of achievable quality of T2*-weighted images at the level of the hippocampus and of functional activation maps of the visual cortex. Experiments were performed at 2.0 T and based on single-shot echo-planar imaging at 2. 0 x 2.0 mm(2) resolution, 4 mm section thickness, and 2.0 s temporal resolution. Gradient compensation involved a sequential 16-step variation of the refocusing lobe of the slice-selection gradient (TR/TE = 125/53 ms, flip angle 15 degrees ), whereas thin sections divided the 4-mm target plane into either four 1-mm or eight 0.5-mm interleaved multislice acquisitions (TR/TE = 2000/54 ms, flip angle 70 degrees ). Both approaches were capable of alleviating the inhomogeneity problem for structures in the base of the brain. When compared to standard 4-mm EPI, functional mapping in the visual cortex was partially compromised because of a lower signal-to-noise ratio of inhomogeneity-corrected images by either method. Relative to each other, consistently better results were obtained with the use of contiguous thin sections, in particular for a thickness of 1 mm. Multislice acquisitions of thin sections require minimal technical adjustments.  相似文献   

13.
Several methods have been proposed for motion correction of high angular resolution diffusion imaging (HARDI) data. There have been few comparisons of these methods, partly due to a lack of quantitative metrics of performance. We compare two motion correction strategies using two figures of merit: displacement introduced by the motion correction and the 95% confidence interval of the cone of uncertainty of voxels with prolate tensors. What follows is a general approach for assessing motion correction of HARDI data that may have broad application for quality assurance and optimization of postprocessing protocols. Our analysis demonstrates two important issues related to motion correction of HARDI data: (1) although neither method we tested was dramatically superior in performance, both were dramatically better than performing no motion correction, and (2) iteration of motion correction can improve the final results. Based on the results demonstrated here, iterative motion correction is strongly recommended for HARDI acquisitions.  相似文献   

14.
梯度回波序列是磁共振成像中常用的脉冲序列,然而梯度回波对主磁场波动非常敏感,呼吸等生理运动引起的信号波动会导致图像伪影.该文报道了采用导航回波技术获取呼吸运动导致的局部磁场波动,用以矫正图像回波中随时间变化的相位波动,并将该技术应用于三维多回波梯度回波成像和T2*定量图研究.研究结果显示:矫正前,相位波动幅度随回波时间增长而增大,模图和T2*定量图在相位编码方向有明显伪影,并且男女呼吸伪影水平有显著性差异;矫正后,相位波动幅度大幅下降,图像伪影水平有显著性下降.  相似文献   

15.
Radial MRI is typically used for scans that are sensitive to unavoidable motion. While the translational motion artifact can be easily removed from the radial trajectory data by phase correction, correction of rotational motion still remains a challenge in radial MRI. We present a novel method to refocus the image corrupted by view-to-view motion in the view-interleaved radial MRI data. In this method, the error in rotational view angles was modeled as a polynomial function of the view order and the model parameters were estimated by minimizing the self-navigator image metrics such as image entropy, gradient entropy, normalized gradient squared and mean square difference. Translational motion correction was conducted by aligning the projection profiles. Simulation studies were conducted to demonstrate the robustness of both translational and rotational motion correction methods in different noise levels. The proposed method was successfully applied to correct for motion of healthy subjects. Substantial motion correction with relative error of less than 5% was achieved by using either first- or second-order model with the image metrics. This study demonstrates the potential of the method for motion-sensitive applications.  相似文献   

16.
本文提出了一种基于快速反射镜的像移补偿方法用于解决航空成像中的像移问题。首先通过计算航空相机在曝光时间内的像移速度证明了像移补偿的必要性;针对快速反射镜存在伺服模型不确定性的问题,设计了模型参考自适应控制器;最后通过实验验证了该算法的性能,结果显示:采用本算法后,快速反射镜的阶跃响应稳定时间降低了50%以上,在振动情况下快速反射镜的稳定精度都可以达到10μrad,精度比传统控制方案提升10倍以上。最终的像移补偿成像实验成功验证了基于快速反射镜的像移补偿方案有较高的工程应用价值。  相似文献   

17.

Object

To evaluate the feasibility of an optimized MRI protocol based on high field imaging at 3 T in combination with accelerated data acquisition by parallel imaging for the analysis of oropharyngeal and laryngeal function.

Materials and Methods

Fast 2D gradient echo (GRE) MRI with different spatial resolutions (1.7×2.7 and 1.1×1.5 mm2) and image update rates (4 and 10 frames per second) was employed to assess pharyngeal movements and visualize swallowing via tracking of an oral contrast bolus (blueberry juice). In a study with 10 normal volunteers, image quality was semi-quantitatively graded by three independent observers with respect to the delineation of anatomical detail and depiction of oropharynx and larynx function. Additionally, the feasibility of the technique for the visualization of pathological pre- and post-surgical oropharynx and larynx function was evaluated in a patient with inspiratory stridor.

Results

Image grading demonstrated the feasibility of dynamic MRI for the assessment of normal oropharynx and larynx anatomy and function. Superior image quality (P<.05) was found for data acquisition with four frames per second and higher spatial resolution. In the patient, dynamic MRI detected pathological hypermobility of the epiglottis resulting in airway obstruction. Additional post-surgical MRI for one clinical case revealed morphological changes of the epiglottis and improved function, i.e., absence of airway obstruction and normal swallowing.

Conclusion

Results of the volunteer study demonstrated the feasibility of dynamic MRI at 3 T for the visualization of the oropharynx and larynx function during breathing, movements of the tongue and swallowing. Future studies are necessary to evaluate its clinical value compared to existing modalities based on endoscopy or radiographic techniques.  相似文献   

18.

Purpose

The objective of this work was to evaluate the diagnostic performance of the intravoxel incoherent motion (IVIM) model to differentiate between healthy and malignant prostate tissue.

Materials and Methods

Regions of interest were drawn in healthy and cancerous tissue of 13 patients with histologically proven prostate carcinoma and fitted to a monoexponential model [yielding the apparent diffusion coefficient (ADC)] and the IVIM signal equation (yielding the perfusion fraction f, the diffusion constant D and the pseudodiffusion coefficient of perfusion D?). Parameter maps were calculated for all parameters.

Results

The ADC, D and f were significantly (P<.005) lowered in cancerous tissue (1.01±0.22 μm2/ms, 0.84±0.19 μm2/ms and 14.27±7.10%, respectively) compared to benign tissue (1.49±0.17 μm2/ms, 1.21±0.22 μm2/ms and 21.25±8.32%, respectively). Parameter maps of D and f allowed for a delineation of the tumor, but showed higher variations compared to the ADC map.

Conclusion

Apparent diffusion coefficient maps provide better diagnostic performance than IVIM maps for tumor detection. However, the results suggest that the reduction of the ADC in prostate cancer stems not only from changes in cellularity but also from perfusion effects. IVIM imaging might hold promise for the diagnosis of other prostatic lesions.  相似文献   

19.

Purpose

To compare peak enhancement (PE), determined from dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and the magnetic resonance (MR) directionally-averaged apparent diffusion coefficient () in glandular versus stromal prostatic tissues and, with this comparison, to infer if the hypothesis that gadolinium-DTPA (Gd-DTPA) does not enter healthy glands or ducts is plausible.

Materials and Methods

MRI, MR spectroscopic imaging, DCE MRI and MR diffusion were evaluated in 17 untreated subjects with suspected or proven prostate cancer. PE and were compared in glandular-ductal tissues [normal peripheral zone and glandular benign prostatic hyperplasia (BPH)] and stromal-low ductal tissues (central gland/mixed BPH and stromal BPH).

Results

The glandular-ductal tissues had lower PE [125±6.4 (% baseline)] and higher [1.57±0.15 (s/10−3 mm2)] than the stromal-low ductal tissues [PE=132±5.5 (% baseline) (P<.0008), =1.18±0.20 (s/10−3 mm2) (P<1×10−8)]. A statistical model based upon stepwise regression was generated and completely separated the tissue types: ductal Measure = 448+669× (s/10−3 mm2)−10.7×PE (1/%), R2=1.0 and P<8×10−10.

Conclusions

The very different MR results in the glandular-ductal versus stromal-low ductal tissues suggest that these tissues have different underlying structure. These results support the hypothesis that Gd-DTPA does not enter healthy prostatic glands or ducts. This may explain the higher PE and lower that previously have been reported in prostate cancer versus healthy tissue.  相似文献   

20.
朱磊  韩天琪  水鹏朗  卫建华  顾梅花 《物理学报》2014,63(17):179502-179502
本文提出了一种抑制合成孔径雷达图像乘性相干斑噪声的各向异性扩散滤波新方法.该方法将受自适应耦合函数控制的平均曲率运动嵌入到传统相干斑抑制的各向异性扩散方程中,形成了一种可有效抑制边缘区域相干斑与同质区块效应现象的各向异性扩散新方程,同时在新建的扩散方程中,引入了由改进Frost滤波与局部方向比率联合构建的一种带方向约束的新扩散函数,进一步削弱了块效应现象且明显改善了抑斑图像的边缘抖动扭曲问题.实验结果表明该方法在有效保护图像边缘的同时,能充分平滑同质区与边缘区域的相干斑,明显削弱块效应现象,有效改善抑斑图像边缘抖动扭曲问题,而抑斑图像无论视觉效果还是参数指标均比多种传统抑斑方法更具优势.  相似文献   