首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Ion interaction reagent RP-HPLC has been employed for the separation of some typical aliphatic and aromatic amines. The effects on retention of the alkyl chain length of the eluent, and of the eluent flow-rate have been studied. The use of solutions of hexylaminium-, octylaminium-and decylaminium-salicylate has been tested and compared, employing both conductometric and spectrophotometric detection. On the basis of the results obtained, the optimal experimental conditions can be chosen for each separation. Aliphatic and aromatic mono and diamines can be separated and detected, with an average sensitivity of the order of 40 ng without any pretreatment or derivatization. The retention data obtained for amines, compared with those obtained with the same ion interaction reagents for anions, help in the interpretation of the mechanism involved in the technique.  相似文献   

2.
3.
Summary A metallic copper electrode housed in a suitable flowcell is shown to be a sensitive and versatile potentiometric detector for ion chromatography. This electrode may be used for direct or indirect detection of many inorganic anions and cations and also for organic acids. In the direct detection mode, electrode response is based on either complexation of copper ions at the electrode surface by eluted species, or on oxidation and reduction reactions for eluted species which are strong oxidants or reductants. Direct detection is therefore applicable to such species as amino acids, organic acids, chloride, bromide, iodide, chlorate, bromate and iodate. Indirect detection is possible for anions which do not complex copper ions, provided a copper complexing ligand (such as phthalate) is used in the eluent; cations which complex this ligand are also detectable. Indirect detection may be used for species such as nitrite, nitrate, acetate, formate, succinate, benzoate, alkaline earth ions and transition metal ions. Electrode calibration relationships are discussed and sample separations are presented, together with some typical detection limits attainable in the direct and indirect detection modes.Presented in part at a National Symposium on Ion Chromatography, held at the University of New South Wales, Kensington, Australia, Nov. 21, 1984.  相似文献   

4.
Summary In this paper the use of phenylalanine as eluent for indirect photometric chromatography is reported. The effects of the mobile phase pH, phenylalanine concentration etc. on the eluent strength and the sensitivity of detection are discussed. Using 3 mM aqueous solution of phenylalanine at pH 3.0 containing 1% methanol as the mobile phase, a mixture of alkali metals was separated and sodium ion concentration in water was determined on a low-capacity cation-exchange column.  相似文献   

5.
Kozaki D  Shi CH  Tanaka K  Nakatani N 《色谱》2012,30(4):361-364
To enhance the conductivity detection sensitivity of common anions(Na-anions) in electrostatic ion chromatography(EIC) by elution with water,a conductivity enhancement column packed with strong acid cation exchange resin in the H-form was inserted between an octadecyl silane(ODS)-silica separation column modified with zwitterionic surfactant(CHAPS: 3-{(3-cholamidopropyl)-dimethylammonio}propanesulfonate) and a conductivity detector.Specifically,the Na-anion pairing is converted to H-anion pairing after the EIC separation and then detected sensitively by the conductivity detector.The effects of conductivity enhancement and suppression in the EIC by the enhanced conductivity detection were characterized for the common strong acid anions such as SO2-4,Cl-,NO-3,I-and ClO-4 and weak acid anions such as F-,NO-2,HCOO-,CH3COO-and HCO-3.For the conductivity enhancement effect in the EIC,it is found that the conductivity of measured for all strong acid anions(Na-anions) was enhanced according to the theoretical conductivity predicted for H-anions and that of the measured for weak acid anions was suppressed depending on their pKa of H-anions.For the calibration linearity in the EIC,the strong acid anions were linear(r2=0.99-1.00) because the degree of dissociation is almost 1.0 over all the concentration range and that of the weak acid anions was non-linear because the degree of dissociation decreased by increasing the concentration of the weak acid anions.In conclusion,the EIC by enhanced conductivity detection was recognized to be useful only for the strong acid anions in terms of conductivity detection and calibration linearity.  相似文献   

6.
7.
Fischer  K.  Corsten  C.  Leidmann  P.  Bieniek  D.  Kettrup  A. 《Chromatographia》1994,38(1-2):43-51
Summary Short chain aliphatic acids are important components of the dissolved organic matter in silage effluents. Although ion exclusion chromatography offers some advantages for the analysis of these compounds, no attempt has yet been made to prove the suitability of this method for silage effluent analysis. In order to gain experience in this field, the separation characteristics of a Dionex ion exclusion column (IonPac-ICE As5) have been evaluated, the separation conditions have been improved, and several sample clean-up methods have been checked.Ten effluents generated during silaging of five different crops were collected from Bavarian farms and analyzed. Lactic and acetic acids were the predominant aliphatic acids. Pyruvic, formic, propionic, and succinic acid were detected in all samples, whereas glyceric and iso-citric acid were found in a few samples only.If some restrictions of substance specificity and separation efficiency can be accepted, the analytical method presented will be a reliable tool for the analysis of carboxylic acids in silage effluents.  相似文献   

8.
The perchlorate anion (ClO 4 ) is an anthropogenic contaminant of increasing concern in water supplies, and has been shown to disrupt thyroid activity. Most perchlorate analyses are currently carried out by ion chromatography (IC) with suppressed conductivity detection (SCD). While this procedure has been demonstrated to provide acceptable performance for analysis of water samples, the determination of perchlorate in high-conductivity aqueous extracts of plant or animal material is not readily accomplished by IC-SCD unless lengthy cleanup protocols are applied. With the addition of electrospray ionization mass spectrometry (ESI-MS) to IC, it was hypothesized that the interference imposed by various ionic species could be significantly reduced without the need for purification; however, the analysis of perchlorate in relatively unpurified extracts of biologically derived homogenates by IC-ESI-MS has not previously been described in the literature. The research presented here represents a comparison of the capabilities of IC-SCD and IC-ESI-MS to detect perchlorate in reagent water and in crude extracts of perchlorate-exposed fish (threespine stickleback, Gasterosteus aculeatus). ESI-MS was found to compare favorably to SCD for the detection of perchlorate in deionized water, and to exceed SCD performance in perchlorate analysis of fish-derived extracts.  相似文献   

9.
Summary Sensitive and selective detection of the sixteen most abundant heterocyclic aromatic amines (HAA) has been achieved by application of high performance liquid chromatography-electrospray tandem mass spectrometry (HPLC-ESI-MS-MS) in combination with selected reaction monitoring (SRM). Detection limits between 0.1 and 50 ng mL–1 were established by use of HAA model solutions.  相似文献   

10.
An improvement of the peak parking technique is described for the serial determination of cations (Na+, , K+, Mg2+, and Ca2+) and anions (Cl, , and ) using a single pump, a single eluent and a single detector. The present system used commercially-available unmodified cation exchange and anion exchange columns, which were attached to each switching valve. When 1.75 mM 5-sulfosalicylic acid was used as the eluent, serial separation of the above cations and anions was achieved in less than 20 min. The proposed ion chromatographic method was successfully applied to the serial determination of cations and anions in tap water and river water samples. The limits of detection at S/N=3 for an injection of 20 μl were 16–68 ppb (μg/l) for cations and 15–28 ppb for anions.  相似文献   

11.
Summary Traces of C1–C4 aliphatic amines, sampled from ambient air on H3PO3-coated annular denuders, are derivatized with m-toluoyl chloride (MTC) in alkaline acetonitrile. The resulting derivatives are determined by reversed phase HPLC with ultraviolet detection at 230 nm. The detection limits of the individual amines are in the 1 to 5 picomole range corresponding to gasphase concentrations lower than 0.1 g m–3 in air samples collected at 5 Lmin–1 for one hour.  相似文献   

12.
建立了利用淋洗液自动发生梯度淋洗的离子交换色谱法同时测定水产品中酪胺、5-羟色胺、腐胺、尸胺、组胺、庚二胺、苯乙胺、亚精胺、精胺、色胺等10种生物胺的方法。样品经处理后用Ionpac CS17分离柱和Ionpac CG17型保护柱分离,以EG40自动淋洗液发生器生成的5.0~55 mmol/L的MSA为淋洗液梯度洗脱,脉冲积分安培检测器检测。对梯度进行优化,10种生物胺都能基线分离,并且浓度和峰面积在一定范围内呈良好的线性关系。检出限在0.04 mg/kg以下,回收率在91.2%~102.5%之间,样品的RSD(n=6)小于5%。方法可用于水产品的检测。  相似文献   

13.
Summary A low exchange-capacity, silica-based cation-exchanger for use in ion chromatography has been synthesized. (p-Trimethylsilyl)benzyl-dimethylchlorosilane (TBDCS) reacts with trimethylsilyl chlorosulfonate (TMCS) to produce a compound sulfonated in the para position of the type ArSO2OSi (CH3)3, which is bonded to 5 μm porous silica beads and hydrolysed to the corresponding arylsulfonic acid. The product is hydrophilic and has a high degree of sulfonation, efficiencies of packed columns reaching about 40,000–50,000 plates per meter for the separation of the Mn2+ ion. The new stationary phase has been applied to the ion chromatography of some organic and inorganic ions. It is notable that 14 lanthanides can be separated by isocratic elution about one hour on a 150×4·6 mm column, with 4 mM ethylenediamine and 6 mM α-hydroxyl-isobutanoic acid (pH 3.67) as mobile phase. The work was supported by the National Science Foundation of China.  相似文献   

14.
A high resolution liquid chromatographic method is described for determination of low molecular weight (LMW) aliphatic amines in environmental waters. The analytes after isolation are derivatized by fluram and separated with isocratic elution on octyl (C8) column, followed by fluorimetric detection in 395/495 nm. Different isolation procedures such as octadecylsilane (ODS) and strong cation exchanger (SCX) solid phase extraction (SPE) cartridges and Amberlite CG-120 resin were evaluated. The quantitative characteristics such as recovery, linear dynamic range, correlation coefficient, limit of detection (LOD), and relative standard deviation (RSD) are presented. Using this method, aliphatic amines were analyzed in rain and tap water as well as in waste water.  相似文献   

15.
I. Isildak 《Chromatographia》1999,49(5-6):338-342
Summary An all solid-state contact tubular PVC-matrix membrane electrode has been applied for potentiometric detection of inorganic and organic monovalent anions using phosphate and hydrogen phosphate eluents at low concentrations. This is a “monovalent detection method” as the selectivity of the electrode towards monovalent anions results in some other anions being undetected unless the concentration of those other anions is higher than 10−3 mol dm−3 in the sample solution injected. It takes only eight minutes to complete the separation with a good resolution. Theoretical and practical considerations are discussed, and in particular, sensitivity, linearity, detection limit and dynamic behaviour are presented. The use of an all solid-state contact bromide-selective electrode as a detector offers so far the best simultaneous sensitivity toward all anions when compared with other detection methods. Determination of Cl and NO3 ions in river, rain and drinking water samples without any further sample preconcentration has been successfully achieved. The detection limit is sub-ppb for most of anions in a 20 μL injection volume.  相似文献   

16.
Summary A simple and general method for the determination of both C1−C10 alkyl sulfonates and alkyl carboxylates using the same basic methodology, based on High Performance ion Chromatography, using relatively simple eluent systems allowing fast analysis with both high sensitivity and accuracy is presented.  相似文献   

17.
Summary An ion chromatographic method has been developed for the separation of Te (IV) and Se(IV) in hydrochloric acid mobile phases; the method has been used to determine tellurium in a high-purity non-stoichiometric semiconducting ZnCdTe-based material. Different cation-exchange columns (IonPac CS2, CS3, CS10), a mixed bed ion-exchange column (IonPac CS5), a multi-mode cation-exchange column (OmniPac PCX-500), anion-exchange columns (IonPac AS4, AS4A, AS5, AS5A, AS10, AS11) and a multi-mode anion-exchange column (OmniPac PAX-500) were evaluated for ion chromatographic separation of Se and Te and to study the chemical forms in which the analytes were eluted. The chromatographic data obtained enabled the calculation of both the sign and the chaarge of the eluting species.  相似文献   

18.
Summary The preparation and performance of a weak cation-exchange stationary phase for Open Tubular Liquid Chromatography (OT-LC) was investigated. The stationary phase was prepared in 5.4 μm I.D. fused silica capillaries byin situ photopolymerization of a mixture of silicon acrylate and acrylic acid. The influence of pH, counter ion concentration and organic modifier concentration of the mobile phase on the retention was studied with catecholamines as test solutes using LIF detection. Other biological amines like amino acids, small peptides and nucleic acid derivatives could be separated on this stationary phase as well. The kinetic performance of the stationary phase was studied with several cations and neutral solutes.  相似文献   

19.
A new succinimidyl ester amine-reactive reagent, N-hydroxysuccinimidyl phenylacetate (SIPA), has been synthesized for analytical derivatization of aliphatic amines, such as methylamine, ethylamine, propylamine, butylamine and pentylamine in gas chromatography (GC). The derivatiation conditions were investigated in detail. The experimental results showed that SIPA was a useful reagent with the advantages including mild derivatization condition, rapid reaction time and selectivity to amino group. In a pH 8.5 H3BO3-Na2B4O7 buffer solution and dichloromethane, the derivatization and extraction can be accomplished at the same time and excess reagent need not be removed before analysis, which greatly simplified the sample preparation. The derivatives were analyzed by gas chromatography-mass spectrometry (GC-MS) and gas chromatography/flame ionization detector (GC/FID). The detection limits (S/N=3) were in the range of pmol level.  相似文献   

20.
Summary A simple and sensitive method has been developed for the liquid chromatographic determination of short-chain aliphatic amines in water. Analytes are retained in solid-phase extraction (SPE) cartridges, and then derivatized by drawing an aliquot of the fluorogeneic reagent 9-fluorenylmethyl chloroformate (FMOC) through the cartridges. After a certain reaction time the derivatives formed are desorbed with acetonitrile. The collected extracts are then chromatographed on a LiChrospher 100 RP18 125 mm×4 mm i.d., 5 μm, column using an acetonitrile-water gradient. The influence of experimental conditions (SPE material, volume of sample, concentration of FMOC, time of reaction and pH) has been investigated. Optimal results have been obtained with C18 SPE cartridges using a sample volume of 5.0 mL. For derivatization, 0.25 mL aliquots of 25 mM FMOC have been used, the reaction time being only 2 min. The method has been applied to the quantification of several aliphatic amines: methylamine, ethylamine, dimethylamine,n-butylamine,n-pentylamine andn-hexylamine. Under the proposed conditions the percentages of analytes retained plus derivatized were of about 54–107% compared to those obtained with direct solution derivatization. The method provided good reproducibility, linearity and accuracy within the 0.050–1.0 mg L−1 concentration range. The limits of detection were in the 0.25–5.0 μg L−1 range. The utility of the described approach has been tested by analysing tap water, river water and industrial waste water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号