首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
吴漪  王彦  谷雪  张琳  阎超 《色谱》2010,28(3):226-230
加压毛细管电色谱(pCEC)具有电泳和液相色谱的双重分离机理,其柱效高、选择性强、分辨率高和分离速度快并可进行梯度洗脱。我们在此基础上加入离子交换色谱模式,构建了强阳离子交换-反相加压毛细管液相色谱(micro strong cation exchange liquid chromatography/reversed phase pressurized capillary electrochromatography, μ-SCXLC/RP-pCEC)二维系统,并对中药黄柏的提取物进行了优化分离。第一维μ-SCXLC采用线性盐梯度分离,样品被切割成11个馏分洗脱收集后进入第二维,第二维脱盐后,采用RP-pCEC进行分离分析,梯度洗脱。以中药黄柏提取物为样品,此二维系统的分辨率和峰容量都较一维系统有很大提高,理论峰容量可达900左右,证明构建的二维体系非常适合复杂样品的分离分析。  相似文献   

2.
On-line solid phase extraction (SPE) coupled to liquid chromatography-mass spectrometry (LC-MS) offers an easy and fast strategy to analyze the organic contaminants in environmental samples with high sensitivity and selectivity. This paper described an in-house designed on-line SPE system and an on-line SPE-LC-MS method for the determination of pesticides at trace levels in water samples. The system was assembled from an eight-position valve, a piston pump, a six-port valve and a C18 SPE column, and significantly reduced analysis time by achieving full automation. Moreover, the use of a large enrichment volume (50?mL) significantly enhanced method sensitivity. Using this on-line SPE system, an on-line SPE-LC-MS method was developed for the determination of nine pesticides at trace levels in lake water and seawater sample. Under optimized conditions, method detection limits (MDLs) were 1.00–10.0?ng?L?1.  相似文献   

3.
A rapid, sensitive and fully automated on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) method was developed and validated for the direct analysis of 14 antidepressants and their metabolites in plasma. Integration of the sample extraction and LC separation into a single system permitted direct injection of the plasma without prior sample pre-treatment. The applied gradient ensured the elution of all the examined drugs within 14 min and produced chromatographic peaks of acceptable symmetry. The total process time was 20 min and only 50 microL of plasma was required. Selectivity of the method was achieved by a combination of retention time and two precursor-product ion transitions for the non-deuterated compounds. The use of SPE was demonstrated to be highly effective and led to significant decreases in the interferences present in the matrix. Extraction was found to be both reproducible and efficient with recoveries >99% for all the analytes. The method showed excellent intra-assay and inter-assay precision (relative standard deviation (RSD) and bias <20%) for quality control (QC) samples spiked at a concentration of 40, 200 and 800 microg/L and the r2>0.99 over the range investigated (10-1000 microg/L). Limits of quantification (LOQs) were estimated to be 10 microg/L. Furthermore, the processed samples were demonstrated to be stable for at least 48 h, except for clomipramine and norclomipramine, where a slight negative trend was observed, but did not compromise the quantification. The method was subsequently applied to authentic samples previously screened by a routine HPLC method with diode array detection (DAD).  相似文献   

4.
Triacontyl bonded silica (C(30)) material was applied as solid-phase extraction (SPE) sorbent and an SPE-LC-MS method was established for the determination of eight estrogens and their metabolites in water samples. Compared to commercial C(18) SPE cartridge, the performance of C(30) was evaluated in various important SPE conditions, such as sorbent mass, elution solvent and its volume, loading flow rate, and sample loading volume. The results showed a superior performance of C(30)-C(18) by the shorter treatment time and fewer required elution solvent. In the optimum conditions, the results showed good recoveries (80.5-109.4%), excellent linear relationships (0.02-1 ng/mL, except 2-MeO-E(2)), high precisions (lower than 10.0% RSD for both low and high spiked concentration), and low LODs (1-16 ng/L). Method validation using C(30) packed cartridge was also testified with spiked real water samples, including tap water and river water. Satisfy results demonstrated the feasibility of C(30) SPE to the analysis for real environmental waters.  相似文献   

5.
In this study, a new procedure, based on on-line solid-phase extraction (SPE) and analysis by liquid-chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), has been developed for the simultaneous, multianalyte determination of 21 selected pesticides, phenols and phthalates in water. SPE was carried out on polymeric PLRP-s cartridges by percolating 20 mL-samples. For sample preconcentration, the performance of a prototype programmable field extraction system (PROFEXS) was evaluated against the commercial laboratory bench Prospekt system used for method development. The Profexs is designed for the automated on-site sampling, SPE preconcentration, and storage of up to 16 samples in SPE cartridges. These cartridges are further eluted and on-line analyzed with the Prospekt coupled to the chromatographic system. In the optimized method, where completely on-line SPE-LC-MS analysis of the samples is carried out with the Prospekt in the laboratory, detection limits lower than 100 ng/L, and satisfactory precision (relative standard deviations <25%) and accuracies (recovery percentages >75%) were obtained for most investigated compounds from the analysis of spiked Milli-Q water. The extraction efficiency achieved with the Profexs was comparable to that of the Prospekt for most compounds and somewhat lower for the most apolar analytes, probably due to adsorption on the pump filters. The completely on-line optimized method was applied to the analysis of surface water, ground water and drinking water from a waterworks in Barcelona. Some pesticides and phenols were found in both surface water and groundwater at ng/L or µg/L levels, but not in the final drinking water. Di(2-ethylhexyl)phthalate (DEHP) was present in all samples investigated, including blanks. To the author's knowledge, this is the first work describing the application of a fully automated on-line SPE-LC-MS method for the simultaneous analysis of pesticides, phenols, and phthalates in water, and the second one that examines the possibilities of the prototype Profexs for automated on-site SPE preconcentration of organic pollutants from water samples.  相似文献   

6.
Li J  Chen L  Wang X  Jin H  Ding L  Zhang K  Zhang H 《Talanta》2008,75(5):1245-1252
An automated system using on-line solid-phase extraction (SPE) high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was developed for the determination of tetracyclines (TCs), such as tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC), metacycline (MC), and doxycycline (DC) in honey. One milliliter diluted honey sample was injected into a conditioned C18 SPE column and the matrix was washed out with water for 3 min. By rotation of the switching valve, TCs were eluted and transferred to the analytical column by the chromatographic mobile phase. Chromatographic conditions were optimized. TCs were separated in less than 8 min with a gradient elution using a mixture of 0.8% formic acid and acetonitrile. The UV detection was performed at 365 nm. The conditions for on-line SPE, including solvent and total time for loading sample and washing matrix were also optimized. Time for extraction and separation decreased greatly. For the five kinds of TCs, the limits of detection (LODs) at a signal-to-noise of 3 ranged from 5 to 12 ng g−1. The relative standard deviations (R.S.D.) for the determination of TCs ranged from 3.4 to 7.1% within a day and ranged from 3.2 to 8.9% in 3 days, respectively.  相似文献   

7.
An on-line sample preparation method utilizing a time-programmed autosampler is described for high throughput liquid chromatography/mass spectrometry (LC/MS). This approach is particularly helpful for the LC/MS analysis of samples which require solvents incompatible with HPLC in the sample preparation process. The on-line sample preparation approach minimizes a bottleneck in throughput and improves sample recovery under some circumstances.  相似文献   

8.
The coupling of solid-phase extraction (SPE) using bamboo charcoal (BC) as an adsorbent with a monolithic column-high performance liquid chromatography (MC-HPLC) method was developed for the high-efficiency enrichment and rapid determination of 16 polycyclic aromatic hydrocarbons (PAHs) in water. Key influence factors, such as the type and the volume of the elution solvent, and the flow rate and the volume of the sample loading, were optimized to obtain a high SPE recovery and extraction efficiency. BC as an SPE adsorbent presented a high extraction efficiency due to its large specific surface area and high adsorption capacity; MC as an HPLC column accelerated the separation within 8 min because of its high porosity, fast mass transfer, and low-pressure resistance. The calibration curves for the PAHs extracted were linear in the range of 0.2-15 μg/L, with the correlation coefficients (r(2)) between 0.9970-0.9999. This method attained good precisions (relative standard deviation, RSD) from 3.5 to 10.9% for the standard PAHs I aqueous solutions at 5 μg/L; the method recoveries ranged in 52.6-121.6% for real spiked river water samples with 0.4 and 4 μg/L. The limits of detection (LODs, S/N = 3) of the method were determined from 11 and 87 ng/L. The developed method was demonstrated to be applicable for the rapid and sensitive determination of 16 PAHs in real environmental water samples.  相似文献   

9.
Abstract

High-performance liquid chromatographic (HPLC) separation of steroidal hormones and cephalosporin antibiotics was investigated by adsorption chromatography and reversed-phase chromatography, respectively.

Prior to the HPLC separation of these pharmaceuticals, silica gel thin-layer adsorption chromatography of steroidal hormones and reversed-phase thin-layer partition chromatography of cephalosporin antibiotics with chemically bonded dimethylsilyl silica gel were performed in order to obtain suitable HPLC separation systems.

In the separation of steroidal hormones, the same binary mobile phase ratios of TLC did not give satisfactory results in HPLC. For the sharp separation in HPLC, solvent strength in the binary solvent mixture used for TLC had to be decreased.

The difference in solvent strength for efficient separation between TLC and HPLC might be attributed to the fact that in HPLC the solvent elution power acts in an isocratic manner while in TLC it acts in a gradient manner.

On the other hand, a correlation of mobility between TLC and HPLC separation for cephalosporin antibiotics was obtained, and the possibility of direct transfer of chromatographic systems from TLC to HPLC for separation of these antibiotics was confirmed.  相似文献   

10.
An on-line solid-phase extraction liquid chromatography/tandem mass spectrometry (SPE LC/MS/MS) assay using a newly developed SPE column and a monolithic column was developed and validated for direct analysis of plasma samples containing multiple analytes. This assay was developed in an effort to increase bioanalysis throughput and reduce the complexity of on-line SPE LC/MS/MS systems. A simple column-switching configuration that requires only one six-port valve and one HPLC pumping system was employed for on-line plasma sample preparation and subsequent gradient chromatographic separation. The resulting analytical method couples the desired sensitivity with ease of use. The method was found to perform satisfactorily for direct plasma analysis with respect to assay linearity, specificity, sensitivity, precision, accuracy, carryover, and short-term stability of an eight-analyte mixture in plasma. A gradient LC condition was applied to separate the eight analytes that cannot be distinctly differentiated by MS/MS. With a run time for every injection of 2.8 min, a minimum of 300 direct plasma injections were made on one on-line SPE column without noticeable changes in system performance. Due to the ruggedness and simplicity of this system, generic methods can be easily developed and applied to analyze a wide variety of compounds in a high-throughput manner without laborious off-line sample preparation.  相似文献   

11.
陈静  刘召金  戴振宇  安保超  许群  张祥民 《色谱》2013,31(9):894-897
建立了一个简单、快速、有效的适用于质谱或液相色谱-质谱联用的在线固相萃取(SPE)高通量除盐方法。方法分为单柱和双柱模式,借助于包含双梯度泵(上样泵/分析泵)、自动进样器和配有十通切换阀的柱温箱的高效液相色谱系统,完成样品的自动化在线除盐。单柱模式通过上样泵实现在SPE柱上进样和除盐,被分析物则保留在SPE柱上;除盐完成后,通过阀切换利用分析泵洗脱富集在SPE柱上的被分析物。双柱模式则在单柱模式基础上增加了1根SPE柱,在色谱管理软件控制下2根SPE柱轮流工作,高效率完成样品的在线除盐。该方法在结合质谱分析蛋白质、多肽等领域具有较好的应用前景。  相似文献   

12.
建立了同时检测水稻中6种内源性植物激素脱落酸( Abscisic acid,ABA)、吲哚-3-乙酸( Indole-3-acetic acid, IAA)、水杨酸( Salicylic acid,SA)、茉莉酸( Jasmonic acid,JA)、吲哚-3-丙酸( Indole-3-propionic acid, IPA)和吲哚-3-丁酸( Indole-3-butyric acid,IBA)的全自动在线固相萃取-液相色谱-串联质谱方法。植物样品经过甲醇提取,采用C18固相萃取柱富集净化,流动相将待测物洗脱至C18分析色谱柱进行分离,最终使用串联四极杆质谱进行检测。方法的线性范围为8~320μg/L,相关系数为R2≥0.99;方法的检出限(S/N=3)范围为0.1~0.8μg/kg;实际样品中方法回收率范围为71.2%~126%,RSD<13%。应用本方法快速、准确地检测了水稻幼穗中多种内源性植物激素的含量,并与目前植物学领域内常用的检测方法进行了比较。同时,本方法对水稻受伤叶片的内源植物激素含量变化进行了定量分析,其含量随受伤时间的变化趋势与其生物背景的实验结果相吻合。  相似文献   

13.
Three preconcentration techniques including solid phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and stir-bar sorptive extraction (SBSE) have been optimized and compared for the analysis of six hypolipidaemic statin drugs (atorvastatin, fluvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin) in wastewater and river water samples by high performance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry (HPLC/Q-TOF-MS). Parameters that affect the efficiency of the different extraction methods such as solid phase material, sample pH and elution solvent in the case of SPE; the type and volume of the extracting and dispersive solvent, pH of sample, salt addition and number of extraction steps in the case of DLLME; and the stirring time, pH of sample, sample volume and salt addition for SBSE were evaluated. SPE allowed the best recoveries for most of the analytes. Pravastatin was poorly extracted by DLLME and could not be determined. SBSE was only applicable for lovastatin and simvastatin. However, despite the limitations of having poorer recovery than SPE, DLLME and SBSE offered some advantages because they are simple, require low organic solvent volumes and present low matrix effects. DLLME required less time of analysis, and for SBSE the stir-bar was re-usable. SPE, DLLME and SBSE provided method detection limits in the range of 0.04-11.2 ng L−1, 0.10-17.0 ng L−1 for 0.52-2.00 ng L−1, respectively, in real samples. To investigate and compare their applicability, SPE, DLLME and SBSE procedures were applied to the detection of statin drugs in effluent wastewater and river samples.  相似文献   

14.
New generation of sequential injection analysis (SIA) called sequential injection chromatography (SIC) has already been consolidated as a good alternative of high performance liquid chromatography (HPLC) for fast analysis of simple samples. Benefits of flow methods are automation, miniaturization and low sample and mobile phase consumption. Implementation of short monolithic chromatographic column into SIA opens new area—on-line chromatographic separation of multi-compound sample in low-pressure flow system, with the advantage of flow programming and possibility of sample manipulation. In the presented review the potential of SIC and its comparison with HPLC for determination of pharmaceutical mixtures is discussed and outlines past and recent trends focused on separation with SIC.  相似文献   

15.
In this study, a rapid, sensitive, and fully automated on-line solid phase extraction (SPE)?Cliquid chromatography (LC)?Cmass spectrometry (MS) method for the analysis of explosive residues in water, was systematically investigated. First, separation of explosive residues was achieved by reverse-phase chromatography using an XDB-C18 column in 30 min with an eluent containing 0.1% acetic acid, 5 mM ammonium acetate, and methanol. Secondly, atmospheric pressures chemical ionization (APCI) and electrospray ionization (ESI) interfaced with the MS detector were used to examine the explosive residues, indicating that APCI?CMS was more suitable than ESI?CMS for the detection of explosives. Thirdly, the conditions for on-line SPE, including solvent pH and sample injected volume, were optimized. The calibration curves obtained for all explosives studied were linear in the concentration range 0.5?C50 ??g L?1. The detection limits of this method ranged from 0.05 to 0.5 ??g L?1 when 4000 ??L of sample was on-line pre-concentrated on C18 enrichment column. The recoveries from lake waters spiked with explosive standard solution ranged from 90.5 to 108.0%. The proposed method is simple, fast, and could be applied successfully to the analysis of explosive residues in contaminated water without any further pretreatment.  相似文献   

16.
This paper describes the first coupling of a commercial capillary HPLC system with a diode array spectrophotometric detector and a custom-built nuclear magnetic resonance (NMR) flow microprobe. The eluent from a 3-microm diameter C18 HPLC column is linked to a 500 MHz 1H-NMR microcoil probe with an observe volume of 1.1 microl. The separation and structurally-rich detection of a mixture of terpenoids under both isocratic and gradient solvent elution conditions is presented. The lowest limits of detection yet reported for capillary HPLC on-line measurement (i.e., 37 ng for alpha-pinene) are achieved with this system. The complementary nature of diode array and NMR detection allows stopped-flow data collection from analytes which would otherwise go unnoticed in continuous-flow NMR. Moreover, stopped-flow NMR data is presented for the detection of a trace (sub-nmol) impurity in the sample mixture. Since NMR signals degrade and shift during solvent gradients, flow injection analysis studies are conducted with injected solvent plugs differing in mobile phase composition. The NMR signal degradation accompanying these injections is largely due to the variance in chemical shift with the solvent composition rather than to changes in magnetic susceptibility of the solvent. Characterization of such effects enables the development of improved NMR probes for the coupling of capillary HPLC and NMR.  相似文献   

17.
A new analytical method has been developed for sample preconcentration and analysis of phenolic compounds in sherry wine using on-line solid-phase extraction(SPE)-HPLC-diode array detection. The samples of wine were injected and adsorbed onto polystyrene divinylbenzene cartridges; a robotic semiflexible system was used to automate the SPE stage. Chromatographic separation was carried out in a Symmetry C18 steel cartridge, with a two-step elution gradient. Peaks were identified by comparing their UV spectra with the library of spectra compiled by the authors.  相似文献   

18.
杨成雄  杨雪清  严秀平 《色谱》2019,37(8):824-830
制备了金属-有机骨架(MOF)MIL-101(Cr)掺杂聚合物整体柱,建立了在线固相萃取-高效液相色谱检测水中4-硝基苯酚、2-硝基苯酚、3-甲基苯酚和2,4-二氯苯酚的方法。考察了样品溶液pH值、上样时间、上样流速和解吸时间对酚类化合物萃取效果的影响。在最优萃取条件下,采用制备的整体柱检测水中酚类化合物,其富集因子高,线性范围宽,精密度好,检出限低,适用于水中酚类化合物的检测。制备掺杂聚合物整体柱是促进和拓宽MOFs在线固相萃取应用的有效方法之一。  相似文献   

19.
Wang S  Li D  Hua Z  Zhao M 《The Analyst》2011,136(18):3672-3679
We report a novel method for simultaneous determination of cyromazine and melamine based on a molecularly imprinted monolith on-line coupled with high performance liquid chromatography (HPLC). The imprinted monolith was prepared by in situ polymerization using 2,4-diamino-6-undecyl-1,3,5-triazine (DAUTA) as a mimic template. Due to the better solubility of DAUTA in chloroform, hydrogen bonds were effectively developed between the template and the functional monomer and resulted in the formation of highly specific cavities in the obtained imprinted monolith. With methanol as the loading solvent, cyromazine and melamine were both selectively retained by the obtained imprinted monolith, while the nonspecific adsorption on the non-imprinted monolith was negligible. The imprinted monolithic column was on-line coupled with HPLC for purification and concentration of the two analytes from milk samples. To minimize the peak broadening during the on-line transfer of the analytes from the imprinted monolith to the following analytical column, a successive desorption program was developed for the elution step, which enabled on-line stacking of the target compounds before being analyzed by HPLC. Low detection limits of 0.12 μg mL(-1) for melamine and 0.05 μg mL(-1) for cyromazine were achieved with only 0.3 mL of milk sample and a low sensitivity HPLC-UVD instrument. The method may be further extended to detect other analytes of interest in a large variety of samples.  相似文献   

20.
Summary Solid phase extraction (SPE) methods are studied for the sample pretreatment for HPLC analysis ofTaxus cell suspension cultures. Various types of SPE materials were tested for the extraction of both the taxane standards and samples of various origin. Comparison between the different cartridges and the different elution solvents are made in terms of extraction recovery and sample clean-up. Selective elution of the taxanes is achieved by a gradient elution scheme.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号