首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 727 毫秒
1.
We developed a CE and ultrasound‐assisted temperature‐controlled ionic liquid emulsification microextraction method for the determination of four parabens (methyl paraben, ethyl paraben, propyl paraben, and butyl paraben) in personal care products including mouthwash and toning lotion. In the proposed extraction procedure, ionic liquid (IL, 1‐octyl‐3‐methylimidazolium hexafluorophosphate) was used as extraction solvent, moreover, no disperser solvent was needed. Parameters affecting the extraction efficiency including volume of IL, heating temperature, ultrasonic time, extraction time, sample pH, ionic strength, and centrifugation time were optimized. Under the optimized conditions, the method was found to be linear over the range of 3–500 ng/mL with coefficient of determination (R2) in the range of 0.9990–0.9998. The LODs and LOQs for the four parabens were 0.45–0.72 ng/mL and 1.50–2.40 ng/mL, respectively. Intraday and interday precisions (RSDs, n = 5) were in the range of 5.4–6.8% and 7.0–8.7%, respectively. The recoveries of parabens at different spiked levels ranged from 71.9 to 119.2% with RSDs less than 9.5%.  相似文献   

2.
We have developed a synergic microextraction procedure based on ionic liquid for the pre‐concentration and determination of glucocorticoids in water samples. Using nonionic surfactant Triton X‐100 (TX‐100) as synergic reagent, 1‐butyl‐3‐methylimidazolium hexa‐fluorophosphate accomplished extraction rapidly without heating in water bath. One key property of ionic liquids that highlights their potential is their wide liquid temperature range. The improved extraction was named as ionic liquid supported vortex‐assisted synergic microextraction. Compared with the traditional liquid–liquid extraction and cloud point extraction, ionic liquid supported vortex‐assisted synergic microextraction was accomplished in 8 min with considerably high recovery. The proposed method greatly improved the sensitivity of HPLC for the determination of glucocorticoids. The results obtained indicated a good linearity with the correlation coefficient of 0.997 over the range of 0.6–300 ng/mL and high sensitivity with LODs of 4.11, 9.19, and 7.50 ng/mL for hydrocortisone butyrate, beclomethasone dipropionate, and nandrolone phenylpropionate, respectively. The RSD of the method was 1.57–1.81% (n = 6) with enrichment factor of 99.85, and good recovery (≥97.24%). The method was successfully applied to the determination of glucocorticoids in mineral water, water of Dianchi lake, and tap water samples.  相似文献   

3.
In situ ionic‐liquid‐dispersive liquid–liquid microextraction was introduced for extracting Sudan dyes from different liquid samples followed by detection using ultrafast liquid chromatography. The extraction and metathesis reaction can be performed simultaneously, the extraction time was shortened notably and higher enrichment factors can be obtained compared with traditional dispersive liquid–liquid microextraction. When the extraction was coupled with ultrafast liquid chromatography, a green, convenient, cheap, and efficient method for the determination of Sudan dyes was developed. The effects of various experimental factors, including type of extraction solvent, amount of 1‐hexyl‐3‐methylimidazolium chloride, ratio of ammonium hexafluorophosphate to 1‐hexyl‐3‐methylimidazolium chloride, pH value, salt concentration in sample solution, extraction time and centrifugation time were investigated and optimized for the extraction of four kinds of Sudan dyes. The limits of detection for Sudan I, II, III, and IV were 0.324, 0.299, 0.390, and 0.655 ng/mL, respectively. Recoveries obtained by analyzing the seven spiked samples were between 65.95 and 112.82%. The consumption of organic solvent (120 μL acetonitrile per sample) was very low, so it could be considered as a green analytical method.  相似文献   

4.
In this work, a novel, efficient, and green sorbent, SiO2@Fe3O4 has been created and functionalized with 1‐butyl‐3‐methylimidazolium hexafluorophosphate as an ionic liquid. This sorbent was applied for microextraction of four beta blockers, propranolol, metoprolol, atenolol, and alprenolol with bupivacaine as internal standard from human plasma followed by liquid chromatography with mass spectrometric detection. A mixture of sodium bicarbonate and sodium dihydrogen phosphate was used as an extractant dispersive agent (effervescent power) to enhance the interaction between the magnetic sorbent and analytes. Main affecting parameters on microextraction and elution were optimized. Figures of merit for dispersive solid phase extraction with ionic liquid coated magnetic nanoparticles assisted by effervescent powder were calculated under the optimized conditions. The detection limits for propranolol, metoprolol, atenolol, and alprenolol were found at 0.33, 0.62, 0.03, and 0.44 ng/mL, respectively. For all analytes, good linearity was obtained. Intra‐ (n = 5) and interday (n = 10) precision were both under 6.3% while the preconcentration factors were obtained in the range between 15–18. The extraction efficiencies for each analyte ranged from 75 to 91%. The method was successfully applied for determination of trace amounts of the beta blockers in human plasma samples.  相似文献   

5.
A novel microextraction method, termed microwave‐assisted ionic liquid/ionic liquid dispersive liquid–liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high‐performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1‐hexyl‐3‐methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1‐hexyl‐3‐methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1‐butyl‐3‐methylimidazolium tetrafluoroborate. In addition, an ion‐pairing agent (NH4PF6) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00–250.00 μg/L, with the correlation coefficients of 0.9982–0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7–105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples.  相似文献   

6.
A headspace solid‐phase microextraction method was developed for the preconcentration and extraction of methyl tert‐butyl ether. An ionic‐liquid‐mediated multiwalled carbon nanotube–poly(dimethylsiloxane) hybrid coating, which was prepared by covalent functionalization of multiwalled carbon nanotubes with hydroxyl‐terminated poly(dimethylsiloxane) using the sol–gel technique, was used as solid‐phase microextraction adsorbent. This innovative fiber exhibited a highly porous surface structure, high thermal stability (at least 320°C) and long lifespan (over 210 uses). Potential factors affecting the extraction efficiency were optimized. Under the optimum conditions, the method LOD (S/N = 3) was 0.007 ng/mL and the LOQ (S/N = 10) was 0.03 ng/mL. The calibration curve was linear in the range of 0.03–200 ng/mL. The RSDs for one fiber (repeatability, n = 5) at three different concentrations (0.05, 1, and 150 ng/mL) were 5.1, 4.2, and 4.6% and for the fibers obtained from different batches (reproducibility, n = 3) were 6.5, 5.9, and 6.3%, respectively. The developed method was successfully applied to the determination of methyl tert‐butyl ether in different real water samples on three consecutive days. The relative recoveries for the spiked samples with 0.05, 1, and 150 ng/mL were between 94–104%.  相似文献   

7.
A simple, rapid and environment‐friendly technique of single‐drop liquid‐phase microextraction has been developed for the determination of sulfonamides in environmental water. Several important parameters including stirring rate, extraction solvent, extraction pH, salinity and extraction time were optimized to maximize the extract efficiency. Extraction solvent 1‐octyl‐3‐methylimidazolium hexafluorophosphate [C8MIM][PF6] ionic liquid showed better extraction efficiency than 1‐butyl‐3‐methylimidazolium hexafluorophosphate [C4MIM][PF6] and 1‐octanol. The optimum experimental conditions were: pH, 4.5; sodium chloride content, 36% w/v; extraction time, 20 min. This method provided low detection limits (0.5–1 ng/mL), good repeatability (the RSD ranging from 4.2 to 9.9%, n=5) and wide linear range (1–1500 ng/mL), with determination coefficients (r2) higher than 0.9989 for all the target compounds. Real sample analysis showed relative recoveries between 63.5 and 115.8% for all the target compounds.  相似文献   

8.
An ionic liquid‐based dispersive liquid–liquid microextraction followed by RP‐HPLC determination of the most commonly prescribed protease inhibitor, saquinavir, in rat plasma was developed and validated. The effects of different ionic liquids, dispersive solvents, extractant/disperser ratio and salt concentration on sample recovery and enrichment were studied. Among the ionic liquids investigated, 1‐butyl‐3‐methylimidazolium hexafluorophosphate was found to be most effective for extraction of saquinavir from rat serum. The recovery was found to be 95% at an extractant/disperser ratio of 0.43 using 1‐butyl‐3‐methylimidazolium hexafluorophosphate and methanol as extraction and dispersive solvents. The recovery was further enhanced to 99.5% by addition of 5.0% NaCl. A threefold enhancement in detection and quantification limits was achieved, at 0.01 and 0.03 µg/mL, compared with the conventional protein precipitation method. A linear relationship was observed in the range of 0.035–10.0 µg/mL with a correlation coefficient (r2) of 0.9996. The method was validated and applied to study pharmacokinetics of saquinavir in rat serum. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
Determination of methamphetamine in forensic laboratories is a major issue due to its health and social harm. In this work, a simple, sensitive, and environmentally friendly method based on ionic liquid dispersive liquid–liquid microextraction combined with high‐performance liquid chromatography was established for the analysis of methamphetamine in human urine. 1‐Octyl‐3‐methylimidazolium hexafluorophosphate with the help of disperser solvent methanol was selected as the microextraction solvent in this process. Various parameters affecting the extraction efficiency of methamphetamine were investigated systemically, including extraction solvent and its volume, disperser solvent and its volume, sample pH, extraction temperature, and centrifugal time. Under the optimized conditions, a good linearity was obtained in the concentration range of 10–1000 ng/mL with determination coefficient >0.99. The limit of detection calculated at a signal‐to‐noise ratio of 3 was 1.7 ng/mL and the relative standard deviations for six replicate experiments at three different concentration levels of 100, 500, and 1000 ng/mL were 6.4, 4.5, and 4.7%, respectively. Meanwhile, up to 220‐fold enrichment factor of methamphetamine and acceptable extraction recovery (>80.0%) could be achieved. Furthermore, this method has been successfully employed for the sensitive detection of a urine sample from a suspected drug abuser.  相似文献   

10.
An efficient in situ ionic liquid dispersive liquid–liquid microextraction followed by ultra‐performance liquid chromatography was developed to determine four neonicotinoid insecticides in wild and commercial honey samples. In this method, a hydrophobic ionic liquid 1‐butyl‐3‐methylimidazolium hexafluorophosphate, formed by in situ reaction between potassium hexafluorophosphate and 1‐butyl‐3‐methylimidazolium bromide in sample solution, was used as the extraction solvent. In comparison with the traditional dispersive liquid–liquid microextraction method, the developed method required no dispersive solvent. To achieve high extraction efficiency and enrichment factor, the effects of various experimental parameters were studied in detail. Under the optimized conditions, the limits of detection and quantification were in the ranges of 0.30–0.62 and 1.20–2.50 μg/L, respectively. The method showed high enrichment factors (74–115) with the recoveries between 81.0 and 103.4%. The proposed method was finally applied to different wild and commercial honey samples.  相似文献   

11.
A novel manual‐shaking‐ and ultrasound‐assisted surfactant‐enhanced emulsification microextraction method was developed for the determination of three fungicides in juice samples. In this method, the ionic liquid, 1‐ethyl‐3‐methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, instead of a volatile organic solvent was used as the extraction solvent. The surfactant, NP‐10, was used as an emulsifier to enhance the dispersion of the water‐immiscible ionic liquid into an aqueous phase, which accelerated the mass transfer of the analytes. Organic dispersive solvent typically required in common dispersive liquid–liquid microextraction methods was not necessary. In addition, manual shaking for 15 s before ultrasound to preliminarily mix the extraction solvent and the aqueous sample could greatly shorten the time for dispersing the ionic liquid into aqueous solution by ultrasound irradiation. Several experimental parameters affecting the extraction efficiency, including type and volume of extraction solvent, type and concentration of surfactant, extraction time, and pH, were optimized. Under the optimized conditions, good linearity with the correlation coefficients (γ) higher than 0.9986 and high sensitivity with the limit of detection ranging from 0.4 to 1.6 μg/L were obtained. The average recoveries ranged from 61.4 to 86.0% for spiked juice, with relative standard deviations from 1.8 to 9.7%. The proposed method was demonstrated to be a simple, fast, and efficient method for the analysis of the target fungicides in juice samples.  相似文献   

12.
In the present work, an efficient and environmental friendly method of ionic‐liquid‐based emulsified microextraction procedure accelerated by ultrasound radiation has been developed. Subsequently, its performance was compared with dispersive liquid–liquid microextraction and ultrasound‐assisted surfactant‐based emulsification microextraction methods. The optimization of experimental conditions was carried out by combination of central composite design and response surface methodology. The optimum conditions of variables were set as follows: 50 μL of 1‐hexyl‐3‐methylimidazolium hexafluorophosphate (extracting solvent), 10 min ultrasound time, and 10 min vortex time for agitating 6 mL sample solution in pH 3 in the presence of 4 mg sodium dodecyl sulfate without addition of salt and 200 μL of methanol as diluent solvent. Under these conditions, the responses are linear for doxepin and perphenazine in the range of 0.3–1000 and 5–1000 μg/L, respectively. The limits of detection were 0.1 μg/L for doxepin and 1 μg/L for perphenazine. Relative standard deviations were lower than 3.5 for the determination of both species. Finally, the method was used for the preconcentration and determination of doxepin and perphenazine in urine sample with relative recoveries in the range of 89–98%.  相似文献   

13.
In this work, double dispersant‐assisted ionic liquid dispersive liquid–liquid microextraction coupled with micellar electrokinetic chromatography was developed to determine four UV filters (benzophenone, 4‐hydroxybenzophenone, 2,4‐dihydroxybenzophenone, and 2‐hydroxy‐4‐methoxybenzophenone). 1‐Hexyl‐3‐methylimidazolium hexafluorophosphate was used as the extraction solvent. The main novelty of the present work was that acetonitrile‐Triton X‐114 was used as double disperser solvent. Parameters affected the extraction efficiency were investigated and optimized. Under the optimum conditions, enrichment factors were in the range of 25.3?40.5. The limits of detection and quantitation, calculated at a S/N of three and ten, were 3.9?6.7 ng/mL and 13.0?22.3 ng/mL. The linearity of the method was in the range of 0.02?2 μg/mL for 2, 4‐dihydroxybenzophenone and 4‐hydroxybenzophenone, 0.01?2 μg/mL for benzophenone and 2‐hydroxy‐4‐methoxybenzophenone, with correlation coefficient (R2) of 0.9984?0.9991. The proposed method was successfully applied to the determination of four benzophenone‐type UV filters in six kinds of sunscreen cosmetic products, with yielded relative recoveries ranging from 80.2 to 117.7%.  相似文献   

14.
A novel dispersive liquid–liquid microextraction (DLLME) method followed by HPLC analysis, termed sequential DLLME, was developed for the preconcentration and determination of aryloxyphenoxy‐propionate herbicides (i.e. haloxyfop‐R‐methyl, cyhalofop‐butyl, fenoxaprop‐P‐ethyl, and fluazifop‐P‐butyl) in aqueous samples. The method is based on the combination of ultrasound‐assisted DLLME with in situ ionic liquid (IL) DLLME into one extraction procedure and achieved better performance than widely used DLLME procedures. Chlorobenzene was used as the extraction solvent during the first extraction. Hydrophilic IL 1‐octyl‐3‐methylimidazolium chloride was used as a dispersive solvent during the first extraction and as an extraction solvent during the second extraction after an in situ chloride exchange by bis[(trifluoromethane)sulfonyl]imide. Several experimental parameters affecting the extraction efficiency were studied and optimized with the design of experiments using MINITAB® 16 software. Under the optimized conditions, the extractions resulted in analyte recoveries of 78–91%. The correlation coefficients of the calibration curves ranged from 0.9994 to 0.9997 at concentrations of 10–300, 15–300, and 20–300 μg L?1. The relative SDs (n = 5) ranged from 2.9 to 5.4%. The LODs for the four herbicides were between 1.50 and 6.12 μg L?1.  相似文献   

15.
Tocopherol homologues are important fat‐soluble bioactive compounds with high nutritional value. However, it is of great challenge to separate these homologues because of their high structural similarities. In this work, ionic‐liquid‐based countercurrent chromatography was used for the separation and purification of tocopherol homologues. Conventional countercurrent chromatography and ionic‐liquid‐based countercurrent chromatography solvent systems were evaluated in respect of partition coefficient, separation factor, and stationary phase retention factor to separate these targets. Kind of ionic liquids, amount of ionic liquid, and sample amount were systematically optimized. A novel countercurrent chromatography non‐aqueous biphasic system composed of n‐hexane‐methanol‐1‐butyl‐3‐methylimidazolium chloride was established. The baseline separation of tocopherol mixtures was obtained in one cycle process. The ionic liquid played a key role in the countercurrent chromatography separation, which resulted in difference of partition behavior of individual tocopherol in the whole system through different hydrogen‐bonding affinity. Finally, n‐hexane‐methanol‐1‐butyl‐3‐methylimidazolium chloride (5:5:3, v/v) water‐free biphasic system was successfully applied to separate tocopherol homologues from vegetable oil that was not achieved beforehand. This method can be widely employed to separate many similar molecules such as tocotrienols, tocomonoenols, and marine‐derived tocopherol in food samples.  相似文献   

16.
A green and simple method, ionic liquid‐based microwave‐assisted surfactant‐improved dispersive liquid–liquid microextraction and derivatization was developed for the determination of aminoglycosides in milk samples. Nonionic surfactant Triton X‐100 and ionic liquid 1‐hexyl‐3‐methylimidazolium hexafluorophosphate were used as the disperser and extraction solvent, respectively. Extraction, preconcentration, and derivatization of aminoglycosides were carried out in a single step. Several experimental parameters, including type and volume of extraction solvent, type and concentration of surfactant, microwave power and irradiation time, concentration of derivatization reagent, and pH value and volume of buffer were investigated and optimized. Under the optimum experimental conditions, the linearities for determining the analytes were in the range 0.4–10.0 ng/mL for tobramycin, 1.0–25.0 ng/mL for neomycin, and 2.0–50.0 ng/mL for gentamicin, with the correlation coefficients ranging from 0.9991 to 0.9998. The LODs for the analytes were between 0.11 and 0.50 ng/mL. The present method was applied to the analysis of different milk samples, and the recoveries of aminoglycosides obtained were in the range 96.4–105.4% with the RSDs lower than 5.5%. The results showed that the present method was a rapid, convenient, and environmentally friendly method for the determination of aminoglycosides in milk samples.  相似文献   

17.
A novel 1‐butyl‐3‐methylimidazolium chloride ionic liquid surface imprinted solid‐phase sorbent was synthesized. The as‐prepared material was characterized by SEM, Brunauer–Emmett–Teller surface area analysis and Fourier Transform IR measurements. Then its adsorption properties for alkyl imidazolium ionic liquids, including adsorption capacities, adsorption kinetics, and properties of selective separation and enrichment were studied in detail. It was shown that the ionic liquid surface imprinted polymer exhibited high selective recognition characteristics for the imidazolium chloride ionic liquids with short alkyl chains (CnmimCl, n = 2, 4, 6, 8) and the adsorption equilibrium was achieved within 25 min. Various parameters were optimized for the 1‐butyl‐3‐methylimidazolium chloride ionic liquid surface imprinted polymer SPE column, such as flow rate, eluent solvent, selectivity, and reusability of the column. Then, the SPE column coupled with HPLC was used for the determination of alkyl imidazolium ionic liquids. Experimental results showed that the existence of their structural analogs and common concomitants in environmental matrices did not affect the enrichment of 1‐butyl‐3‐methyl imidazolium chloride ionic liquid. The average recoveries of 1‐butyl‐3‐methylimidazolium chloride ionic liquid in spiked water samples were in the range of 92.0–102.0% with the RSD lower than 5.8%.  相似文献   

18.
An efficient, inexpensive and environmentally benign ultrasound‐assisted supramolecular‐solvent‐based microextraction technique combined with high‐performance liquid chromatography was used for the determination of chlorophenols in environmental water samples. Different factors such as amount of decanoic acid, volume of tetrahydrofuran, pH of the sample, ultrasound time and ionic strength were investigated and optimized. The optimized extraction conditions were 60 mg decanoic acid, 1.5 mL tetrahydrofuran, 3 min ultrasound time, without salt addition. Under this condition, the extraction recoveries were 83.0–89.3 with preconcentration factors of 94–102. The calibration curves were linear from 5.0–400.0 ng/mL with square of the correlation coefficient higher than 0.9998 and the limits of detection were between 1.5–2.0 ng/mL. The values of intra‐ and inter‐day relative standard deviations were 3.2–6.0 and 7.3–8.0%, respectively. Analysis of different samples showed that the concentration of 2,5‐dichlorophenol in Babolrood river water was 80.6 ng/mL.  相似文献   

19.
In the present study, an in‐syringe ultrasound‐assisted emulsification‐microextraction using a low‐density organic solvent was developed for simultaneous extraction and pre‐concentration of amlodipine besylate and nifedipine from plasma samples. The extracts were analyzed by high‐performance liquid chromatography with UV detection. Central composite design combined with desirability function was applied to find out the optimal experimental conditions providing the highest global extraction efficiency. The optimal conditions identified were volume of the extracting solvent 45 μL, ionic strength 18.95% w/v, sonication time 2.58 min, and centrifugation time 3 min. Under the optimal conditions, the proposed method was evaluated, and applied to the analysis of amlodipine besylate and nifedipine in plasma samples. The validation results of the method indicated a wide linear range (2–1200 ng/mL) with a good linearity (r2 >0.9991) and low detection limits (0.17 ng/mL for amlodipine besylate and 0.15 ng/mL for nifedipine) with RSD less than 5.2% for both components, both in intra‐ and inter‐day precision studies. The applicability of the proposed in‐syringe ultrasound‐assisted emulsification‐microextraction coupled to high‐performance liquid chromatography with UV detection method was demonstrated by analyzing the drugs in spiked plasma samples.  相似文献   

20.
A sensitive method based on ionic liquid for single‐drop liquid microextraction coupled with HPLC‐UV was developed for the determination of carbonyl compounds in environmental waters using 1‐octyl‐3‐methylimidazolium hexafluorophosphate [C8min][PF6] as extraction solvent and 2,4‐dinitrophenylhydrazine as derivatizing agent. The extraction parameters affecting the enrichment factors such as solvent volume, pH, extraction time and salt concentration were investigated. A homemade funnel form polytetrafluoroethylene sleeve was fixed at the tip of the syringe needle and this allowed the use of 10 μL drop of ionic liquid for direct immersion extraction. Under the optimal conditions, the remarkable enrichment factors up to 150‐fold were obtained depending on the target analytes. The method has been validated when rectilinear relationship was obtained between the concentrations of analytes and peak area in the range of 5–100 ng/mL, the correlation coefficients were from 0.995 to 0.998, and the limit of detection was in the range of 0.04–2.03 ng/mL. The method was applied to monitor the concentration of carbonyl compounds in environmental waters with spiked recovery in the range of 84.2–106.9%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号