首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ionic liquid carbon‐coated magnetic nanoparticles were successfully applied as an adsorbent in a mixed hemimicelle magnetic dispersive solid‐phase extraction method for the determination of tramadol from urine samples coupled with high‐performance liquid chromatography with UV‐vis detection. The significant parameters affect the extraction efficiency including type and amount of adsorbent, sample volume, pH, ionic strength, type and amount of elution solvent, time of extraction and desorption, time of ionic liquid loading on the adsorbent and stirring rate were studied and optimized. The proposed method provided a fast, straightforward, environmentally friendly and adsorbent recyclable approach for tramadol analysis. The linear range for the tramadol determination was from 100 to 1500 ng/mL. Precisions and accuracies were within 6%. The applicability of the proposed method in clinical trial was tried successfully on determination of tramadol in addicted subjects under tramadol therapy. The mean percent recovery of the patient samples was 94%. The results proved that the proposed method could be applied in clinical and forensic laboratories for determination of tramadol from biological urine samples.  相似文献   

2.
Polypyrrole‐magnetite dispersive micro‐solid‐phase extraction method combined with ultraviolet‐visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole‐magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro‐solid‐phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole‐magnetite dispersive micro‐solid phase‐extraction conditions were sample pH 8, 60 mg polypyrrole‐magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole‐magnetite dispersive micro‐solid‐phase extraction with ultraviolet‐visible method showed good linearity in the range of 0.05–7 mg/L (R 2 > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4–111.3%) with relative standard deviations < 10%. The method was successfully applied to the analysis of dyes in textile wastewater samples where the concentration found was 1.03 mg (RSD ±7.9%) and 1.13 mg/L (RSD ± 4.6%) for Rhodamine 6G and crystal violet, respectively. It can be concluded that this method can be adopted for the rapid extraction and determination of dyes at trace concentration levels.  相似文献   

3.
A simple pH‐responsive magnetic solid‐phase extraction method was developed using graphene oxide–coated nanoscale zerovalent iron nanoparticles as an efficient adsorbent prior to high‐performance liquid chromatography‐tandem mass spectrometry for determination of ultra‐trace quinolones in milk samples. Various parameters affecting maghemite synthesis and separation such as pH of sample solution, amount of magnetic adsorbent, eluent type, and volume were optimized. The limits of detection are from 3.1 to 13.3 ng/L. The intra‐ and interprecision values are in the range of 2.9–6.9% and 7.6–15.1%, respectively. Recoveries are from 82.4 to 103.9%. Therefore, this simple and sensitive method is suitable for detecting ultra‐trace quinolone residues in milk.  相似文献   

4.
A new, rapid, green, and cost‐effective magnetic solid‐phase extraction of ochratoxin A from red wine samples was developed using polydopamine‐coated magnetic multi‐walled carbon nanotubes as the absorbent. The polydopamine‐coated magnetic multi‐walled carbon nanotubes were fabricated with magnetic multi‐walled carbon nanotubes and dopamine by an in situ oxidative self‐polymerization approach. Transmission electron microscopy, dynamic light scattering, X‐ray photoelectron spectroscopy and vibrating sample magnetometry were used to characterize the absorbents. Ochratoxin A was quantified with high‐performance liquid chromatography coupled with fluorescence detection, with excitation and emission wavelengths of 338 and 455 nm, respectively. The conditions affecting the magnetic solid‐phase extraction procedure, such as pH, extraction solution, extraction time, absorbent amount, desorption solution and desorption time were investigated to obtain the optimal extraction conditions. Under the optimized conditions, the extraction recovery was 91.8–104.5% for ochratoxin A. A linear calibration curve was obtained in the range of 0.1–2.0 ng/mL. The limit of detection was 0.07 ng/mL, and the limit of quantitation was 0.21 ng/mL. The recoveries of ochratoxin A for spiked red wine sample ranged from 95.65 to 100.65% with relative standard deviation less than 8%. The polydopamine‐coated magnetic multi‐walled carbon nanotubes showed a high affinity toward ochratoxin A, allowing selective extraction and quantification of ochratoxin A from complex sample matrixes.  相似文献   

5.
A novel design of hollow‐fiber liquid‐phase microextraction containing multiwalled carbon nanotubes as a solid sorbent, which is immobilized in the pore and lumen of hollow fiber by the sol–gel technique, was developed for the pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples. The proposed method utilized both solid‐ and liquid‐phase microextraction media. Parameters that affect the extraction of polycyclic aromatic hydrocarbons were optimized in two successive steps as follows. Firstly, a methodology based on a quarter factorial design was used to choose the significant variables. Then, these significant factors were optimized utilizing central composite design. Under the optimized condition (extraction time = 25 min, amount of multiwalled carbon nanotubes = 78 mg, sample volume = 8 mL, and desorption time = 5 min), the calibration curves showed high linearity (R 2 = 0.99) in the range of 0.01–500 ng/mL and the limits of detection were in the range of 0.007–1.47 ng/mL. The obtained extraction recoveries for 10 ng/mL of polycyclic aromatic hydrocarbons standard solution were in the range of 85–92%. Replicating the experiment under these conditions five times gave relative standard deviations lower than 6%. Finally, the method was successfully applied for pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples.  相似文献   

6.
A new facile magnetic micro‐solid‐phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite‐MCM‐41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite‐MCM‐41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05–500 μg/L (r 2 = 0.996–0.999). Good limits of detection (0.008–0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n  = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1–115.4%. Results indicate that magnetite micro‐solid‐phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.  相似文献   

7.
In this work, an easy, effective, and sensitive method based on graphene oxide@silica@magnetite composites as adsorbent of magnetic solid‐phase extraction combined with liquid chromatography and tandem mass spectrometry, was established and validated for the trace analysis of cytokinins in different plants. The prepared magnetic composite was characterized by infrared spectroscopy, transmission electron microscopy, Brunauer–Emmett–Teller analysis, and magnetic hysteresis. Under the optimized conditions, good linearities in the range of 0.5–100 ng/mL were obtained with the corresponding linear correlation coefficient >0.9989 for the investigated four cytokinins, and good sensitivity levels were achieved with low detection limits ranging from 93 to 120 pg/mL. The established magnetic solid‐phase extraction with liquid chromatography and tandem mass spectrometry method has been validated in the separation and analysis of four cytokinins in plant samples with good recoveries between 78.9 and 97.3% for four cytokinins with the relative standard deviations lower than 13.5%.  相似文献   

8.
A new type of adsorbent composed of magnetic three‐dimensional graphene coated with silver nanoparticles was synthesized by an electroless technique and used in the magnetic solid‐phase extraction of selected pesticides (fenitrothion, chlorpyrifos, and hexaconazole) before gas chromatography with a micro‐electron capture detector. The adsorbent was characterized using Fourier‐transform infrared spectroscopy, X‐ray diffraction, vibrating sample magnetometry, and field‐emission scanning electron microscopy. The important extraction parameters such as pH, adsorbent dose, extraction time, and desorption conditions were investigated. Under the optimal conditions, the analytical figures of merit were obtained as: linear dynamic range of 0.1–5 ng/g with determination coefficients of 0.991–0.996; limit of detection of 0.07–0.13 ng/g; limit of quantification of 0.242–0.448 ng/g; and the intraday and interday relative standard deviations (= 5 ng/g, = 3) were 3.8–8.7 and 6.6–8.9%, respectively. The developed method was successfully applied for analysis of the selected pesticides in tomato and grape with extraction recoveries in the range of 72.8–109.6%.  相似文献   

9.
Metal–organic frameworks‐5 (MOF‐5) was explored as a template to prepare porous carbon due to its high surface area, large pore volume, and permanent nanoscale porosity. Magnetic porous carbon, Co@MOF‐5‐C, was fabricated by the one‐step direct carbonization of Co‐doped MOF‐5. After carbonization, the magnetic cobalt nanoparticles are well dispersed in the porous carbon matrix, and Co@MOF‐5‐C displays strong magnetism (with the saturation magnetization intensity of 70.17emu/g), high‐specific surface area, and large pore volume. To evaluate its extraction performance, the Co@MOF‐5‐C was applied as an adsorbent for the magnetic solid‐phase extraction of endocrine disrupting chemicals, followed by their analysis with high‐performance liquid chromatography. The developed method exhibits a good linear response in the range of 0.5–100 ng/mL for pond water and 1.0–100 ng/mL for juice samples. The limits of detection (S/N  = 3) for the analytes were in the range of 0.1–0.2 ng/mL.  相似文献   

10.
Surfactant cetyltrimethylammonium bromide enhanced molybdenum disulfide was used as an adsorbent in pipette‐tip solid‐phase extraction for the pretreatment of sulfonamides in environmental water samples. The factors affecting the extraction recoveries of the analytes, including the sample pH value, amount of sorbent, type and volume of eluent solution, and salt concentration were optimized. This pipette‐tip solid‐phase extraction method demonstrated good linearity (0.05–10.0 µg/L) with a coefficient of determination of 0.9984–0.9996, limit of detection (0.2–0.4 ng/L) and limit of quantitation (0.5–1.0 ng/L), good analyte recoveries (76–91), and acceptable limit of quantitation (<10%) under the optimized conditions. These results indicated that the proposed method was a good tool for monitoring sulfonamides in environmental water samples.  相似文献   

11.
A magnetic solid‐phase extraction method coupled with gas chromatography was proposed for the determination of polycyclic aromatic hydrocarbons in the environmental water samples. The magnetic adsorbent was prepared by incorporating Fe3O4 nanoparticles, multi‐walled carbon nanotubes, and polypyrrole. The main factors affecting the extraction efficiency including the amount of the sorbents, desorption conditions, extraction time, salt concentration, and sample solution pH were investigated and optimized. Under the optimum conditions, good linearity was obtained within the range of 0.03?100 ng/mL for all analytes, with correlation coefficients ranging from 0.9942 to 0.9973. The method detection limits (S/N = 3) were in the range of 0.01–0.04 ng/mL and the limits of quantification (S/N = 10) were 0.03–0.1 ng/mL. Repeatability of the method was assessed through five consecutive extractions of independently prepared solutions at concentrations of 0.1, 10, and 100 ng/mL of the compounds. The observed repeatability ranged 3.4–10.9% depending of the compound considered. The proposed method was successfully applied in the analysis of PAHs in environmental samples (tap, well, river, and wastewater). The recoveries of the method ranged between 93.4 and 99.0%. The procedure proved to be efficient and environmentally friendly.  相似文献   

12.
In this work, a magnetic β‐cyclodextrin polymer was successfully prepared and used as an adsorbent for the magnetic solid‐phase extraction of six benzoylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, teflubenzuron, flufenoxuron, and chlorfluazuron) from honey, tomato, and environmental water samples. The influence of the main experimental conditions on the extraction was studied. Under the optimized conditions, the β‐cyclodextrin polymer@Fe3O4 showed an excellent extraction performance for the benzoylurea insecticides. A good linearity was obtained for the analytes in the range of 3.0–800 ng/g for honey samples, 0.3–160 ng/g for tomato samples, and 0.1–80.0 ng/mL for water samples, with the correlation coefficients above 0.9998. Satisfactory repeatabilities were achieved, with the relative standard deviations less than 5.7%. The limits of detection (S/N = 3) of the method for the benzoylurea insecticides were 0.2–0.8 ng/g for honey samples, 0.04–0.10 ng/g for tomato samples, and 0.02–0.05 ng /mL for water samples. The method was successfully used for the determination of the six benzoylurea insecticides residues in honey, tomato, and environmental water samples with a satisfactory result.  相似文献   

13.
A new method based on cetylpyridinium chloride coated ferroferric oxide/silica magnetic microspheres as an efficient solid‐phase adsorbent was developed for the extraction and enrichment of ochratoxin A. The determination of ochratoxin A was obtained by high‐performance liquid chromatography with fluorescence detection. In the presence of cetylpyridinium chloride, the adsorption capacity of ferroferric oxide/silica microspheres was 5.95 mg/g for ochratoxin A. The experimental parameters were optimized, including the amounts of ferroferric oxide/silica microspheres (20 mg) and cetylpyridinium chloride (0.18 mL, 0.5 mg/mL), pH value of media (9), ultrasonic time (5 min), elution solvent and volume [2(1 + 1) mL (washed twice, 1 mL each time) 1% acetic acid acetonitrile]. Under optimal experiment conditions, ochratoxin A had good linearity in the range of 2.5–250.0 ng/L in water samples with correlation coefficient of the calibration curve 0.9995. The limit of detection for ochratoxin A was 0.83 ng/L, and the recoveries were 89.8–96.8% with the relative standard deviation of 1.5–3.5% in environmental water samples. Furthermore, ferroferric oxide/silica microspheres show excellent reusability during extraction procedures for no less than six times.  相似文献   

14.
An iron‐embedded porous carbon material (MIL‐53‐C) was fabricated by the direct carbonization of MIL‐53. The MIL‐53‐C possesses a high surface area and good magnetic behavior. The structure, morphology, magnetic property, and porosity of the MIL‐53‐C were studied by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and N2 adsorption. With the use of MIL‐53‐C as the magnetic solid‐phase extraction adsorbent, a simple and efficient method was developed for the magnetic solid‐phase extraction of three hormones from water and human urine samples before high‐performance liquid chromatography with UV detection. The developed method exhibits a good linear response in the range of 0.02–100 ng/mL for water and 0.5–100 ng/mL for human urine samples , respectively. The limit of detection (S/N = 3) for the analytes was 0.005–0.01 ng/mL for water sample and 0.1–0.3 ng/mL for human urine sample. The limit of quantification (S/N = 10) of the analytes were in the range of 0.015–0.030 and 0.3–0.9 ng/mL, respectively.  相似文献   

15.
In this work, a novel, rapid, and simple analytical method was proposed for the detection of parabens in milk sample by gas chromatography coupled with mass spectrometry. At the same time, milk sample was pretreated by magnetic solid phase extraction, which detected up to five parabens. A series of important parameters of magnetic solid phase extraction were investigated and optimized, such as pH value of loading buffer, amount of material, adsorption time, ionic strength, eluting solvents, and eluting time. Under the optimized conditions, the corresponding values were more than 0.9991, limits of detection and the limit of quantification were 0.1 and 0.5 ng/mL, respectively. In addition, the recoveries were achieved in range of 95–105%, the liner range were within 0.1–600 ng/mL, and the relative standard deviations were even lower than 5%.  相似文献   

16.
We describe the preparation, characterization, and application of a composite film adsorbent based on blended agarose‐chitosan‐multiwalled carbon nanotubes for the preconcentration of selected nonsteroidal anti‐inflammatory drugs in aqueous samples before determination by high performance liquid chromatography with ultraviolet detection. The composite film showed a high surface area (4.0258 m2/g) and strong hydrogen bonding between the multiwalled carbon nanotubes and agarose/chitosan matrix, which prevent adsorbent deactivation and ensure long‐term stability. Several parameters, such as sample pH, addition of salt, extraction time, desorption solvent, and concentration of multiwalled carbon nanotubes in the composite film were optimized using a one‐factor‐at‐time approach. The optimum extraction conditions obtained were as follows: isopropanol as conditioning solvent, 10 mL of sample solution at pH 2, extraction time of 30 min, stirring speed of 600 rpm, 100 μL of isopropanol as desorption solvent, desorption time of 5 min under ultrasonication, and 0.4% w/v of composite film. Under the optimized conditions, the calibration curve showed good linearity in the range of 1–500 ng/mL (r2 = 0.997–0.999), and good limits of detection (0.89–8.05 ng/mL) were obtained with good relative standard deviations of < 4.59% (n = 3) for the determination of naproxen, diclofenac sodium salt, and mefenamic acid drugs.  相似文献   

17.
A three‐dimensional graphene was synthesized through a hydrothermal reaction of graphene oxide with phytic acid. The microstructure and morphology of the phytic acid induced three‐dimensional graphene were investigated by nitrogen adsorption–desorption isotherms, scanning electron microscopy, and transmission electron microscopy. With a large surface area and three‐dimensional structure, the graphene was used as the solid‐phase extraction adsorbent for the extraction of phthalate esters from bottled water and sports beverage samples before high‐performance liquid chromatographic analysis. The results indicated that the graphene was efficient for the solid‐phase extraction of phthalate esters. The limits of detection (S/N = 3) of the method for the analytes were 0.02–0.03 ng/mL for the water samples and 0.03–0.15 ng/mL for the sports beverage sample. The limits of quantitation (S/N = 9) for the analytes were 0.06–0.09 ng/mL for water samples and 0.09–0.45 ng/mL for sports beverage sample. The calibration curves for the phthalate esters by the method had a good linearity from 0.1 to 80.0 ng/mL with correlation coefficients larger than 0.9997. The recoveries of the analytes for the method fell in the range of 86.7–116.2% with the relative standard deviations between 1.5 and 6.8%.  相似文献   

18.
An adsorbent of carbon dot@poly(glycidyl methacrylate)@Fe3O4 nanoparticles has been developed for the microwave‐assisted magnetic solid‐phase extraction of polycyclic aromatic hydrocarbons in environmental aqueous samples prior to high‐performance liquid chromatography with UV/visible spectroscopy detection. Poly(glycidyl methacrylate) was synthesized by atom transfer radical polymerization. The chain length and amount of carbon dots attached on them can be easily controlled through changing polymerization conditions, which contributes to tunable extraction performance. The successful fabrication of the nano‐adsorbent was confirmed by transmission electronic microscopy, Fourier transform infrared spectroscopy, Raman spectroscopy and vibrating sample magnetometry. The extraction performance of the adsorbent was evaluated by using polycyclic aromatic hydrocarbons as model analytes. The key factors influencing the extraction, such as microwave power, adsorption time, desorption time and desorption solvents were investigated in detail. Under the optimal conditions, the microwave‐assisted method afforded magnetic solid‐phase extraction with short extraction time, wide dynamic linear range (0.02–200 μg/L), good linearity (R2 ≥ 98.57%) and low detection limits (20–90 ng/L) for model analytes. The adsorbent was successfully applied for analyzing polycyclic aromatic hydrocarbons in environmental aqueous samples and the recoveries were in the range of 86.0–124.2%. Thus, the proposed method is a promising candidate for fast and reliable preconcentration of trace polycyclic aromatic hydrocarbons in real water samples.  相似文献   

19.
Determination of methamphetamine is of great importance in clinical and forensic laboratories because there are low dosages of drugs in the biological media and social problems created due to the methamphetamine consumption. Polymeric carbon based‐nano composites are reasonable candidates for dispersive solid phase extraction method due to facial and affordable synthesis process and high selectivity and sensitivity. Nano graphene oxide polypyrolle composite was synthesized and employed as dispersive solid‐phase extraction adsorbent for methamphetamine extraction from complex urine matrix. Full characterization of the prepared nano graphene oxide polypyrolle composite was completed and the influential extraction parameters were investigated through one‐parameter‐at‐a‐time method. High‐performance liquid chromatography detectors were applied as detection and quantification instrument. The optimized extraction parameters included 300 µL of methanol, 10 min of extraction and desorption time, 6000 stirring rate, urine pH value of 10, 60 mg of adsorbent, and 6 mL of urine volume. After outlining the calibration curve, the linear range of the method was considered as 30–800 ng/mL. The detection limit for the suggested method was 9 ng/mL. The analysis of addicted subjects with the proposed method confirmed the utility of the method in different analytical and clinical laboratories.  相似文献   

20.
Microcystins (MCs), produced by freshwater cyanobacteria, can be serious water pollutants, so it is important to monitor their concentration in drinking water. We have developed a method for rapid and accurate determination of microcystin levels in environmental water, using magnetic solid‐phase extraction and high‐performance liquid chromatography with UV detection. The magnetic composite material, which was combined with cetylpyridinium chloride, was prepared by hydrothermal synthesis. The optimal extraction of microcystins in water sample was achieved by optimizing the amount of adsorbent, time of adsorption, ratio of eluting solvent, and volume of eluent. Under the optimal conditions, the limit of detection of MC‐LR was 0.001 μg/L, and the limit of quantification was 0.0028 μg/L. The limit of detection of MC‐RR was 0.001 μg/L, and the limit of quantification was 0.003 μg/L. These values are far lower than those established by the International Health Organization for the maximum concentration of microcystins in drinking water. The magnetic solid‐phase extraction adsorbent used in this method has the advantages of simple preparation, low price, and easy solid–liquid separation, and it can be used for the rapid and sensitive monitoring of trace microcystins in environmental water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号