首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An analytical method that combined high‐performance liquid chromatography with inductively coupled plasma mass spectrometry has been developed for the determination of hexavalent chromium in traditional Chinese medicines. Hexavalent chromium was extracted using the alkaline solution. The parameters such as the concentration of alkaline and the extraction temperature have been optimized to minimize the interconversion between trivalent chromium and hexavalent chromium. The extracted hexavalent chromium was separated on a weak anion exchange column in isocratic mode, followed by inductively coupled plasma mass spectrometry determination. To obtain a better chromatographic resolution and sensitivity, 75 mM NH4NO3 at pH 7 was selected as the mobile phase. The linearity of the proposed method was investigated in the range of 0.2–5.0 μg L?1 (r2 = 0.9999) for hexavalent chromium. The limits of detection and quantitation are 0.1 and 0.3 μg L?1, respectively. The developed method was successfully applied to the determination of hexavalent chromium in Chloriti lapis and Lumbricus with satisfactory recoveries of 95.8–112.8%.  相似文献   

2.
A new analytical method was developed to determine the bioavailable arsenic species (arsenite, arsenate, monomethylarsonic acid, and dimethylarsonic acid) in soil samples using high‐performance liquid chromatography with inductively coupled plasma mass spectrometry. Bioavailable arsenic was extracted with ammonium phosphate buffer by a simplified one‐step solvent extraction procedure. To estimate the effect of variables on arsenic extraction, a two‐level Plackett–Burman factorial design was conducted to screen the significant factors that were further investigated by a separate univariate approach. The optimum conditions were confirmed by compromising the stability of arsenic species and the extraction efficiency. The concentration of arsenic species was determined in method blank and soil‐certified reference materials both spiked with standard solutions of arsenic species. All the target arsenic species were stable during the whole extraction procedure. Furthermore, the proposed method was applied to release bioavailable arsenic from contaminated soil samples, showing that the major arsenic species in soil samples were inorganic arsenic: arsenite and arsenate, of which the latter was dominant.  相似文献   

3.
Nanoliter high‐performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high‐performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high‐pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high‐performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high‐performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9–1.8 μg/L were obtained with precisions variable in the range of 1.6–4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87–102%).  相似文献   

4.
微波辅助萃取-液质联用技术测底泥砷、硒的化学形态   总被引:3,自引:0,他引:3  
建立了用反相离子对色谱和电感耦合等离子体质谱的联用技术同时测定As(Ⅲ)、 As(Ⅴ)、 MMA、 DMA、 Se(Ⅳ)、 Se(Ⅵ)、 SeMet和SeCys的砷、硒化学形态分析方法. 分别从流动相pH值、离子对试剂的浓度、甲醇量和流速4个方面进行了分离测定条件的优化. 利用碰撞池技术(CCT)较好地解决了^40Ar^35Cl^+复合离子对^75As的干扰, 并使^80Se的测定成为可能, 有效地提高了灵敏度. 将该方法应用于上海市苏州河底泥样品的微波辅助萃取液的形态分析中, 砷和硒的检出限分别达到0.4~1.3 和0.5~1.9 μg/L.  相似文献   

5.
利用高效液相色谱-电感耦合等离子体质谱(HPLC-ICP/MS)对中药材中的6种砷的形态(三价砷(As(Ⅲ))、五价砷(As(Ⅴ))、二甲基砷酸(DMA)、甲基砷酸(MMA)、砷甜菜碱(AsB)和砷胆碱(AsC))进行了同时分析.采用1.2mol/,L HCl浸提,Hamilton PRP-X100阴离子交换色谱柱分离...  相似文献   

6.
Five arsenic species, trimethylarsine oxide, dimethylarsenic acid, monomethylarsonic acid, arsenobetaine and sodium arsenite, in urine were analysed by inductively coupled plasma mass spectrometry with ion chromatography (IC ICP MS). Since the toxicities of different arsenic compounds are different, speciation of arsenic compounds is very important in the investigation of metabolisms. In this paper, we applied ion chromatography (IC) as a separation device and inductively coupled plasma mass spectrometry (ICP MS) as a detection device. For separation of the five arsenic compounds, an anion-exchange column and, as mobile phase, tartaric acid were used. The eluent from the IC column was introduced directly into the nebulizer of the ICP MS and analysed at 75 amu. Detection limits were from 4 to 9 pg as arsenic.  相似文献   

7.
The simultaneous separation and determination of arsenite As(III), arsenate As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC) in rice samples have been carried out in one single anion‐exchange column run by high‐performance liquid chromatography with inductively coupled plasma mass spectrometry. To estimate the effect of variables on arsenic (As) speciation, the chromatographic conditions including type of competing anion, ionic strength, pH of elution buffer, and flow rate of mobile phase have been investigated by a univariate approach. Under the optimum chromatographic conditions, baseline separation of six As species has been achieved within 10 min by gradient elution program using 4 mM NH4HCO3 at pH 8.6 as mobile phase A and 4 mM NH4HCO3, 40 mM NH4NO3 at pH 8.6 as mobile phase B. The method detection limits for As(III), As(V), MMA, DMA, AsB, and AsC were 0.4, 0.9, 0.2, 0.4, 0.5, and 0.3 μg/kg, respectively. The proposed method has been applied to separation and quantification of As species in real rice samples collected from Hunan Province, China. The main As species detected in all samples were As(III), As(V) and DMA, with inorganic As accounting for over 80% of total As in these samples.  相似文献   

8.
采用阴(Hamilton PRP-X100柱)阳(Dionex Ionpac CS-10柱)离子交换色谱-电感耦合等离子体质谱联用技术,分别以pH 10.3的20 mmol/L NH4HCO3和pH 2.0的5 mmol/L吡啶溶液为流动相,建立了As(Ⅲ)、As(Ⅴ)、一甲基砷酸(MMA)、二甲基砷酸(DMA)、砷甜菜碱AsB、砷糖PO4、砷糖OH、砷糖SO3、砷糖SO4砷形态的分析方法。采用微波消解法和超声溶剂提取法对不同海域10种紫菜和海带产品进行前处理,对As含量及其化学形态进行分析。实验表明,样品总砷的质量分数为1.7~38.7 mg/kg,样品萃取物中,As糖PO4和As糖OH为As的主要形态,其含量分别占可提取As的6.5%~67.7%和12.9%~86.2%,海带样品萃取物中还有As糖SO3和DMA被检测,其含量分别占可提取As的13.0%~52.1%和5.9%~17.4%。在紫菜和海带海藻类产品中,含As的化合物主要是毒性较低的有机砷。  相似文献   

9.
A simple method for the speciation analysis of bio-accessible arsenic (As) in rice was developed using a continuous on-line leaching method to release the bio-accessible fraction. The continuous on-line leaching method has several advantages over commonly used batch methods including quicker and easier sample preparation, reduced risk of contamination and access to real time leaching data. The bio-accessibility of As in the samples was monitored using inductively coupled plasma mass spectrometry (ICP-MS). Results from a certified reference material as well as cooked and uncooked white rice showed that the majority of As was leached by saliva. Results obtained using the continuous on-line leaching method were comparable to those obtained using a batch method. Speciation analysis of the saliva leachate was performed using ion exchange chromatography coupled to ICP-MS. The four most toxic forms of As (As(III), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and As(V)) were clearly separated within 5 min in a single chromatographic run. Over 92% of bio-accessible As in the certified reference material and uncooked white rice sample was in the form of DMA and As(V), whereas it was present as DMA and As(III) in the cooked white rice.  相似文献   

10.
This work describes an arsenic speciation analysis in aqueous effluent from a shale industrial plant using liquid chromatography coupled to inductively coupled plasma mass spectrometry (LC–ICP–MS). Arsenic species have been separated through an anion-exchange column and several parameters investigated, such as retention time, pH, flow rate and concentration of the mobile phase (ammonium carbonate), chloride interference and column conditioning time. The best conditions have been found by fixing the pH of the mobile phase at 8.7. Keeping the mobile phase flow rate at 1.5 ml min− 1, arsenic species were separated by varying the concentration of the mobile phase and the time of elution, as follow: 1.5 mmol l− 1 for 10 min, 12 mmol l− 1 for 10 min and 20 mmol l− 1 for 10 min, respectively. Up to 13 As species present in the samples were separated under these conditions and the following species could be identified and quantified: arsenite [As(III)], dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate [As(V)]. The limits of detection of the LC–ICP–MS method were 0.02, 0.06, 0.04 and 0.10 μg l− 1 of As(III), DMA, MMA, and As(V), respectively. The concentration of these species in the samples were from 3.7 to 6.4 μg l− 1, 6.9 to 13.2 μg l− 1, 100 to 142 μg l− 1 and 808 to 1363 μg l− 1 for As(III), DMA, MMA and As(V), respectively. The accuracy, evaluated by recovery tests, varied from 94 to 105% and the precision, evaluated by the relative standard deviation was typically lower than 10%.  相似文献   

11.
采用高效液相色谱( HPLC)和电感耦合等离子体质谱(ICP-MS)联用技术测定了海洋产品中的无机砷.动物性和植物性海洋产品试样经过10% H3PO溶液(V/V)提取,阴离子交换色谱分离,ICP-MS测定其中As(Ⅲ)和As(Ⅴ)的含量.实验结果表明As(Ⅲ)和As(Ⅴ)的检出限分别为5.0和8.0 μg/kg,线性范...  相似文献   

12.
Summary An ICP-MS detector in combination with HPLC has been evaluated for the analysis of six arsenic compounds. The influence of the presence of an organic modifier in the mobile phase on arsenic response and the quality parameters of the analysis are discussed. Detection limits for arsenic species under study range from 10 to 30 pg. The determination of arsenic compounds in solutions simulating fish or sediment extracts has been used to demonstrate the applicability of this technique.  相似文献   

13.
HPLC-ICP-MS测定中药中砷的形态   总被引:2,自引:1,他引:2  
报道了高效液相色谱-电感耦合等离子体质谱(HPLC—ICP-MS)联用技术测定中药中砷的形态,采用阴离子交换柱,以0.2mmol/L EDTA和2mmol/L NaH2PO4的溶液为流动相,pH6.0,流速为1.0mL/min,成功分离了亚砷酸(AsⅢ)、砷酸(AsV)、甲基砷(MMA)和二甲基砷(DMA)。检出限分别为0.67μg/L(AsⅢ),0.85μg/L(DMA),0.43μg/L(MMA),0.70μg/L(AsV)。中药样品经过(1+1)甲醇和水的溶液超声提取,离心、过滤、氮气吹干甲醇,超纯水定容。样品加标平均萃取回收率分别为:92.8%(AsⅢ),108%(DMA),104%(MMA),101%(AsV),相对标准偏差(RsD,n=7)均小于10%。  相似文献   

14.
HPLC-ICP-MS测定中药中砷的形态   总被引:2,自引:0,他引:2  
报道了高效液相色谱-电感耦合等离子体质谱(HPLC-ICP-MS)联用技术测定中药中砷的形态.采用阴离子交换柱,以含0.2 mmol/L乙二胺四乙酸(EDTA)和2 mmol/L NaH2PO4的水溶液为流动相,pH 6.0,流速为1.0 mL/min,成功分离了亚砷酸(AsⅢ)、砷酸(AsⅤ)、甲基砷(MMA)和二甲基砷(DMA).检出限分别为0.67 μg/L (AsⅢ),0.85 μg/L (DMA),0.43 μg/L (MMA),0.70 μg/L (AsⅤ).中药样品经过(1 1)甲醇水溶液超声提取,离心、过滤、氮气吹干甲醇,超纯水定容.样品加标平均萃取回收率分别为: 92.8% (AsⅢ),108% (DMA),104% (MMA),101% (AsⅤ),RSD (n=7)均小于10%.  相似文献   

15.
A high‐performance liquid chromatography coupled with Q‐time of flight mass spectrometry (HPLC/Q‐TOF MS) method was developed and validated for the determination of 1, 3‐diaminopropane, putrescine, cadaverine, spermidine and spermine in human plasma. The plasma samples were first pretreated by 10% HClO4 and then derived by benzoyl chloride with 1, 6‐diaminohexane as internal standard. The derived polyamines were separated on a C18 column using a gradient program. The detection was performed on a Q‐TOF MS by positive ionization mode. Calibration curve for each polyamine was obtained in the concentration range of 0.4 ~ 200.0 ng ? ml?1, with limit of detection of 0.02 ~ 0.1 ng ? ml?1. The intra‐ and inter‐day RSD for all polyamines were 2.5–14.0% and 2.9 ~ 13.4%, respectively. The method was applied to determine the polyamines in human plasma from cancer patients and healthy volunteers. Results showed that the mean levels of polyamines in the plasma of cancer patients were higher than that of healthy volunteers, which suggested that the plasma polyamines could be employed as cancer diagnostic indicators in clinical testing. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
High‐performance liquid chromatography coupled with inductively coupled plasma mass spectrometry was employed for the determination of chromium species. For simultaneous separation of both chromium species by an anion‐exchange column, ethylenediaminetetraacetic acid was induced to form negatively charged complex with Cr(III) normally. Cr(III) chelating reactions are known to be slow, so a high temperature and long reaction time are needed to ensure the completion of the complexing reaction. However, the stability and interconversion of chromium species during the complexing reaction have not been studied earlier. The main aim of this work was to optimize and investigate complexing reaction conditions between ethylenediaminetetraacetic acid and Cr(III). Through optimizing conditions, the reaction will be finished completely in 15 min at pH 7 and 70°C without any obvious interconversion between Cr(VI) and Cr(III). By compromising analysis time, chromatographic resolution, and sensitivity, 60 mM NH4NO3 as competing ion concentration and 1.2 mL/min as flow rate have been selected for real‐sample application. Detection limits for Cr(VI) and Cr(III) were 0.051 and 0.078 μg/L, respectively. The proposed method was used for the determination of chromium species in tap and surface water samples with an acceptable range of spiked recoveries of 95–109%.  相似文献   

17.
A method based on ion chromatography (IC) and inductively coupled plasma MS (ICP-MS) was developed for the speciation of arsenic in water and soil extracts. An anion-exchange column (G3154A/101) was used to separate As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) with excellent resolution. Various ammonium salts, including NH4H2PO4, (NH4)2HPO4, (NH4)2CO3, and NH4HCO3, were examined as eluents to reduce matrix interference from chloride and to solve clogging problems. The best arsenic speciation was obtained within 9 min with excellent resolution and without interference from high chloride concentrations using an eluent containing 7.5 mM (NH4)2HPO4 at pH 7.9. The detection limits for the target arsenic species ranged from 0.1 to 0.4 microg/L with direct injection of sample without matrix elimination. The proposed method was effectively demonstrated by determining arsenic species in contaminated waters and soils of Bangladesh.  相似文献   

18.
Arsenic composes a danger for human health all over the world as it is responsible for water resources contamination. The toxicity of arsenic depends on its chemical form. However, occurrence of particular arsenic species is dependent on processes occurring in water. Nowadays, more arsenic species is detected and analyzed in different kind of water (mineral, tap, waste), mainly owing to great possibilities resulting from coupling high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). This review mainly describes arsenic speciation analysis by HPLC-ICP-MS technique on the basis of articles that have been published since 2000. Arsenic chemistry, occurrence in different kind of water, total arsenic determination with interferences elimination and its validation and analytical performance are also reviewed.  相似文献   

19.
An analytical method for separation and determination of thallium species in water using high‐performance liquid chromatography with inductively coupled plasma mass spectrometry was developed. The composition and concentration of mobile phase, injection volume, and pH value were optimized respectively with an anion or cation exchange column. The results showed that Tl(I) and Tl(III) were effectively separated using anion exchange column Hamilton PRP‐X100, with the mobile phase consisting of 200 mmol/L ammonium acetate and 10 mmol/L diethylenetriaminepentaacetic acid (pH = 4.2). When using a Dionex cation exchange guard column, CS12A, 15 mmol/L HNO3, and 3 mmol/L diethylenetriaminepentaacetic acid as the mobile phase, Tl(I) and Tl(III) could be effectively separated. The detection limits of the methods were 3–6 and 9–12 ng/L, respectively. In a solution containing Fe ions and oxalic acid, a significant quantity of Tl(I) was oxidized. Fe ions and oxalic acid in the water samples did not interfere with high‐performance liquid chromatography‐inductively coupled plasma mass spectrometry measurement results.  相似文献   

20.
Arsenic compounds including arsenous acid (As(III)), arsenic acid (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were separated by high-performance liquid chromatography (HPLC) and detected by inductively coupled plasma mass spectrometry (ICP-MS). A Hamilton PRX-100 anionic-exchange column and a pH 8.5 K2HPO4/KH2PO4 5.0 × 10−3 mol L−1 mobile phase were used to achieve arsenic speciation. The separation of arsenic species provided peaks of As(III) at 2.75 min, DMA at 3.33 min, MMA at 5.17 min and As(V) at 12.5 min. The detection limits, defined as three times the standard deviation of the lowest standard measurements, were found to be 0.2, 0.2, 0.3 and 0.5 ng mL−1 for As(III), DMA, MMA and As(V), respectively. The relative standard deviation values for a solution containing 5.0 μg L−1 of As(III), DMA, MMA and As(V) were 1.2, 2.1, 2.5 and 3.0%, respectively. This analytical procedure was applied to the speciation of arsenic compounds in drinking (soft drink, beer, juice) samples. The validation of the procedure was achieved through the analysis of arsenic compounds in water and sediment certified reference materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号