首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Pesticides, widely applied in agriculture, can produce a variety of transformation products and their continuous use causes deleterious effects to ecosystem. Efficient and sensitive analytical techniques for enrichment and analysis of pesticides samples are highly required. Compared with other extraction methods, solid‐phase micro extraction is a solvent free, cost effective, robust, versatile, and high throughput sample preparation technique, especially for the analysis of pesticides from complicated matrices. Coupling of solid‐phase micro extraction with gas chromatography and mass spectrometry and liquid chromatography–mass spectrometry has been extensively applied in pesticide analysis. On the other hand, in recent years, combination of fast separation using solid‐phase micro extraction and rapid detection using ambient mass spectrometry is providing highly efficient pesticide screening. This article summarizes the applications of solid‐phase micro extraction coupled to mass spectrometry for pesticides analysis.  相似文献   

2.
Headspace gas chromatography is frequently used for aroma profiling thanks to its ability to naturally exploit the volatility of aroma compounds, and also to provide chemical information on sample composition. Its main advantages rely on simplicity, no use of solvent, amenability to automation, and the cleanliness of the extract. In the present contribution, the most effective sampling (dynamic extraction), separation (multidimensional gas chromatography), and detection (mass spectrometry) techniques for untargeted analysis are exploited in combination, showing their potential in unraveling aroma profiles in fruit beers. To complete the overall analytical process, a neat workflow for data analysis is discussed and used for the successful characterization and identification of five different beer flavors (berries, cherry, banana, apple, and peach). From the technical viewpoint, the coupling of purge‐and‐trap, comprehensive two‐dimensional gas chromatography, and mass spectrometry makes the global methodology unique, and it is for the first time discussed. A (low‐)flow modulation approach allowed for the full transfer into the second dimension with mass‐spectrometry compatible flow (< 7 mL/min), avoiding the need of splitting before detection and making the overall method sensitive (1.2–5.2‐fold higher signal to noise ratio compared to unmodulated gas chromatography conditions) and selective.  相似文献   

3.
Multiple ion monitoring (MIM)‐dependent acquisition with a triple quadrupole‐linear ion trap mass spectrometer (Q‐trap) was previously developed for drug metabolite profiling. In the analysis, multiple predicted metabolite ions are monitored in both Q1 and Q3 regardless of their fragmentations. The collision energy in Q2 is set to a low value to minimize fragmentation. Once an expected metabolite is detected by MIM, enhanced product ion (EPI) spectral acquisition of the metabolite is triggered. To analyze in vitro metabolites, MIM‐EPI retains the sensitivity and selectivity similar to that of multiple reaction monitoring (MRM)‐EPI in the analysis of in vitro metabolites. Here we present an improved approach utilizing MIM‐EPI for data acquisition and multiple data mining techniques for detection of metabolite ions and recovery of their MS/MS spectra. The postacquisition data processing tools included extracted ion chromatographic analysis, product ion filtering and neutral loss filtering. The effectiveness of this approach was evaluated by analyzing oxidative metabolites of indinavir and glutathione (GSH) conjugates of clozapine and 4‐ethylphenol in liver microsome incubations. Results showed that the MIM‐EPI‐based data mining approach allowed for comprehensive detection of metabolites based on predicted protonated molecules, product ions or neutral losses without predetermination of the parent drug MS/MS spectra. Additionally, it enabled metabolite detection and MS/MS acquisition in a single injection. This approach is potentially useful in high‐throughout screening of metabolic soft spots and reactive metabolites at the drug discovery stage. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Screening assays capable of performing quantitative analysis on hundreds of compounds per week are used to measure metabolic stability during early drug discovery. Modern orthogonal acceleration time‐of‐flight (OATOF) mass spectrometers equipped with analogue‐to‐digital signal capture (ADC) now offer performance levels suitable for many applications normally supported by triple quadruple instruments operated in multiple reaction monitoring (MRM) mode. Herein the merits of MRM and OATOF with ADC detection are compared for more than 1000 compounds screened in rat and/or cryopreserved human hepatocytes over a period of 3 months. Statistical comparison of a structurally diverse subset indicated good agreement for the two detection methods. The overall success rate was higher using OATOF detection and data acquisition time was reduced by around 20%. Targeted metabolites of diazepam were detected in samples from a CLint determination performed at 1 µM. Data acquisition by positive and negative ion mode switching can be achieved on high‐performance liquid chromatography (HPLC) peak widths as narrow as 0.2 min (at base), thus enabling a more comprehensive first pass analysis with fast HPLC gradients. Unfortunately, most existing OATOF instruments lack the software tools necessary to rapidly convert the huge amounts of raw data into quantified results. Software with functionality similar to open access triple quadrupole systems is needed for OATOF to truly compete in a high‐throughput screening environment. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
The effect of multiple (up to 10 times) injection molding of processed poly(3‐hydroxybutyrate‐co‐4‐hydroxybutyrate) (P(3,4HB)) on its phase transition temperatures, degree of crystallinity, degradation temperature, mass flow rate, mechanical properties, dynamic mechanical properties, and Charpy's impact strength is presented. The studies have shown that the multiple injection lowers the degree of crystallinity and the thermal stability of P(3,4HB). The mass flow rate values increased with increasing the injection number. It was found that the multiple injections had no substantial effect on the tensile strength up to 10 injection cycles and the tensile strength at break, tensile strain at tensile strength, and tensile strain at break up to 6 injection cycles. The maximum value of storage modulus at 30 °C and impact strength were recorded for sample after 4 cycles of injection, while the values of storage modulus at 120 °C increased with increase of the injection cycles. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
Patient‐derived 3D organoids show great promise for understanding patient heterogeneity and chemotherapy response in human‐derived tissue. The combination of organoid culture techniques with mass spectrometry imaging provides a label‐free methodology for characterizing drug penetration, patient‐specific response, and drug biotransformation. However, current methods used to grow tumor organoids employ extracellular matrices that can produce small molecule background signal during mass spectrometry imaging analysis. Here, we develop a method to isolate 3D human tumor organoids out of a Matrigel extracellular matrix into gelatin mass spectrometry compatible microarrays for high‐throughput mass spectrometry imaging analysis. The alignment of multiple organoids in the same z‐axis is essential for sectioning organoids together and for maintaining reproducible sample preparation on a single glass slide for up to hundreds of organoids. This method successfully removes organoids from extracellular matrix interference and provides an organized array for high‐throughput imaging analysis to easily identify organoids by eye for area selection and further analysis. With this method, mass spectrometry imaging can be readily applied to organoid systems for preclinical drug development and personalized medicine research initiatives.  相似文献   

7.
Reported here is the first on‐demand electrochemical epoxidation incorporated into the standard nano‐electrospray ionization mass spectrometry (nanoESI‐MS) workflow for double‐bond identification. The capability lies in a novel tunable electro‐epoxidation of double bonds, where onset of the reaction can be controlled by simply tuning the spray voltage. On‐demand formation of mono‐/multiple epoxides is achieved at different voltages. The electro‐epoxidized products are then fragmented by tandem MS to generate diagnostic ions, indicating the double bond position(s). The process is completed within seconds, holding great potential for high‐throughput analysis. The rapid switch‐on/off electro‐epoxidation of a single sample, the low sample consumption, the demonstrated applicability to complex lipids containing multiple double bonds, and the advantage of not requiring extra apparatus make this method attractive for use in lipid‐related biological studies.  相似文献   

8.
9.
A wide variety of biomass, from triglycerides to lignocellulosic‐based feedstock, are among promising candidates to possibly fulfill requirements as a substitute for crude oils as primary sources of chemical energy feedstock. During the feedstock processing carried out to increase the H:C ratio of the products, heteroatom‐containing compounds can promote corrosion, thus limiting and/or deactivating catalytic processes needed to transform the biomass into fuel. The use of advanced gas chromatography techniques, in particular multi‐dimensional gas chromatography, both heart‐cutting and comprehensive coupled to mass spectrometry, has been widely exploited in the field of petroleomics over the past 30 years and has also been successfully applied to the characterization of volatile and semi‐volatile compounds during the processing of biomass feedstock. This review intends to describe advanced gas chromatography–mass spectrometry‐based techniques, mainly focusing in the period 2011–early 2020. Particular emphasis has been devoted to the multi‐dimensional gas chromatography–mass spectrometry techniques, for the isolation and characterization of the oxygen‐containing compounds in biomass feedstock. Within this context, the most recent advances to sample preparation, derivatization, as well as gas chromatography instrumentation, mass spectrometry ionization, identification, and data handling in the biomass industry, are described.  相似文献   

10.
Direct‐injection mass spectrometry (DIMS) techniques have evolved into powerful methods to analyse volatile organic compounds (VOCs) without the need of chromatographic separation. Combined to chemometrics, they have been used in many domains to solve sample categorization issues based on volatilome determination. In this paper, different DIMS methods that have largely outperformed conventional electronic noses (e‐noses) in classification tasks are briefly reviewed, with an emphasis on food‐related applications. A particular attention is paid to proton transfer reaction mass spectrometry (PTR‐MS), and many results obtained using the powerful PTR‐time of flight‐MS (PTR‐ToF‐MS) instrument are reviewed. Data analysis and feature selection issues are also summarized and discussed. As a case study, a challenging problem of classification of dark chocolates that has been previously assessed by sensory evaluation in four distinct categories is presented. The VOC profiles of a set of 206 chocolate samples classified in the four sensory categories were analysed by PTR‐ToF‐MS. A supervised multivariate data analysis based on partial least squares regression‐discriminant analysis allowed the construction of a classification model that showed excellent prediction capability: 97% of a test set of 62 samples were correctly predicted in the sensory categories. Tentative identification of ions aided characterisation of chocolate classes. Variable selection using dedicated methods pinpointed some volatile compounds important for the discrimination of the chocolates. Among them, the CovSel method was used for the first time on PTR‐MS data resulting in a selection of 10 features that allowed a good prediction to be achieved. Finally, challenges and future needs in the field are discussed.  相似文献   

11.
A negative detection method for proteins on SDS‐PAGE is described. In this method, Eosin Y (EY) was selectively precipitated in the gel background, which is absent from those zones where proteins are located through the formation of a stable water‐soluble protein–dye complex. Negative staining of proteins using EY, allows high‐sensitivity, low‐cost, and simple protocol. The new described method takes less than an hour to complete all the protocol, with a detection limit of 0.5 ng of single protein band. Comparing with imidazole‐zinc negative stain, EY dye provides broader linear dynamic range, higher sensitivity and reproducibility, and better obvious contrast between the protein bands or spots and background. Furthermore, the novel technique developed here presented a real practical method for simultaneous processing of multiple gels, which makes it possible to perform high‐throughput staining for proteome research. Additionally, we have also compared the influence of staining method on the quality of mass spectra by PMF.  相似文献   

12.
Method qualification is a key step in the development of routine analytical monitoring of pharmaceutical products. However, when relying on published monographs that describe longer method times based on older high‐performance liquid chromatography column and instrument technology, this can delay the overall analysis process for generated drug products. In this study, high‐throughput ultrahigh pressure liquid chromatography techniques were implemented to decrease the amount of time needed to complete a 24‐run sequence to identify linearity, recovery, and repeatability for both drug assay and impurity analysis in 16 min. Multiple experimental parameters were tested to identify a range of experimental settings that could be used for the sequence while still maintaining this fast analysis time. The full sequence was replicated on a different system and with different columns, further demonstrating its robustness.  相似文献   

13.
The self‐chemical ionization (SCI) in quadrupole mass spectrometry was developed to determine the structure of (E)‐2‐iod‐3‐(phenylsulfinyl)‐2‐propen‐1‐ol and its 6 analogues. Some techniques that increase the sample quantity and heating speed and shorten vaporization time to obtain high pressure in the ion source were applied to increase the chance of ionmolecule reactions. The structures of these compounds were identified by mass spectral data of MH+ and some characteristic fragment ions. Compared with the mass spectra for 2‐iodo‐3‐(phenylsulfinyl)‐2‐propen‐l‐ols obtained in electron impact ionization (EI), SCI showed more information, in particular, an improvement in amount of information at the high mass area. The absence of reagent gas makes the spectrum clean and simple.  相似文献   

14.
Until recently, multiple solid‐phase microextraction fibers could not be automatically desorbed in a single gas chromatographic sequence without manual intervention from an operator. This drawback had been a critical issue, particularly during the analysis of numerous on‐site samples taken with various fiber assemblies. Recently, a Multi‐Fiber Exchange system, designed to overcome this flaw found in other commercially available autosamplers, was released. In the current research, a critical evaluation of the Multi‐Fiber Exchange system performance in terms of storage stability and long‐term operation is presented. It was established in the course of our research that the Multi‐Fiber Exchange system can operate continuously and precisely for multiple extraction/injection cycles. However, when the effect of residence time of commercial fibers on the Multi‐Fiber Exchange tray was evaluated, results showed that among the evaluated fiber coatings, Carboxen/polydimethylsiloxane was the only coating capable of efficient storage on the tray for up to 24 h after field sampling without suffering significant loss of analytes (≤10% for benzene, toluene, ethylbenzene, o‐xylene, decane, and limonene). Additionally, the system capability for high‐throughput analysis was demonstrated by the unattended desorption of multiple fibers after on‐site sampling of toluene, indoor air levels, in a polymer synthesis lab.  相似文献   

15.
Nanopore‐based techniques, which mimic the functions of natural ion channels, have attracted increasing attention as unique methods for single‐molecule detection. The technology allows the real‐time, selective, high‐throughput analysis of nucleic acids through both biological and solid‐state nanopores. In this Minireview, the background and latest progress in nanopore‐based sequencing and detection of nucleic acids are summarized, and light is shed on a novel platform for nanopore‐based detection.  相似文献   

16.
A high‐throughput mass spectrometric method is presented for the simultaneous detection of Sudan I, II, III, IV and Para‐Red azo‐dyes in foodstuff. The method is based on the use of paper spray mass spectrometry (MS) and deuterium‐labeled internal standards on a triple‐quadrupole instrument. A detailed assay of each azo‐dye was performed by the isotope dilution method, through the precursor ion scan approach, using deuterium‐labeled internal standards. The gas‐phase breakdown pattern of each labeled and unlabeled analogue displays the naphthoic moiety as a common fragment. Sudan dyes can be determined above the threshold of 1 ppm. Paper spray allows for a wide range of analytes and samples to be investigated by MS in the open air and without sample preparation and bypassing chromatography. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
A method coupling hydrophilic interaction chromatography (HILIC) with tandem mass spectrometry (MS/MS) has been developed for the simultaneous determination of three polar non‐structurally related compounds – a carbapenem antibiotic, imipenem (IMP), a renal dehydropeptidase inhibitor, cilastatin (CIL), and an investigational β‐lactamase inhibitor, MK‐4698 (BLI), in rat plasma, monkey plasma and mouse blood. The analytes were extracted through protein precipitation, chromatographed on a Waters Atlantis HILIC column, and detected on a Sciex API4000 mass spectrometer using a Turbo‐Ion Spray ion source in positive ionization mode following multiple‐reaction monitoring (MRM). The assay dynamic range was 0.1–100 µg/mL for IMP, CIL and BLI, respectively, using a total of 20–25 µL biologic samples, and the total HPLC/MS/MS run time was 4 min/injection. The assay was found to be sensitive, selective and reproducible. The challenges, namely, sample stability, blood sample processing, matrix effect in monkey study samples, and dilution re‐assays for the limited mouse blood samples, are resolved and discussed. This technique allowed rapid analysis of polar compounds in biologic matrixes with satisfactory chromatographic retention and increased throughput. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
The applicability of liquid chromatography–mass spectrometry (LC/MS) is often limited by throughput. The sharing of a mass spectrometer with multiple LCs significantly improves throughput; however, the reported systems have not been designed to fully utilize the MS duty cycle, and as a result to achieve maximum throughput. To fully utilize the mass spectrometer, the number of LC units that a MS will need to recruit is application dependent and could be significantly larger than the current commercial or published implementations. For the example of a single analyte, the number may approach the peak capacity to a first degree approximation. Here, the construction of a MS system that flexibly recruits any number of LC units demanded by the application is discussed, followed by the method to port a previously developed LC/MS method to the system to fully utilize a mass spectrometer. To demonstrate the performance and operation, a prototypical MS system of eight LC units was constructed. When 1‐min chromatographic separations were performed in parallel on the eight LCs of the system, the average LC/MS analysis time per sample was 10.5 s when applied to the analysis of samples in 384‐well plate format. This system has been successfully used to conduct large‐volume biochemical assays with the analysis of a variety of molecular entities in support of drug discovery efforts. Allowing the recruitment of the number of LC units appropriate for a given application, this system has the potential to be a plug‐and‐play system to fully utilize a mass spectrometer. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
This work presents a single analytical system able to perform high‐throughput determinations of different pharmaceutical molecules on screen‐printed electrodes (SPEs) assembled on a batch‐injection analysis (BIA) cell. Two types of SPEs, both containing a carbon conductive ink as working electrode, were selected for the determination of levamisole (LVM) in aqueous and sodium levothyroxine (NaLVT) in hydroethanolic media. The main analytical characteristics of the proposed system for both examples are high precision (RSD <3.8 %, n=10), low detection limits (submicromolar range), and high sample‐throughput (>150 h?1) using a single SPE, demonstrating the extended lifetime of such sensors, which are adequate for routine pharmaceutical analysis. The proposed analytical system requires battery‐powered portable devices, including potentiostat and reader, electronic micropipette, BIA cell and SPEs, and can be applied for a wide range of pharmaceutical molecules. In case of analyte adsorption on electrode surface, fast electrode cleaning can be supplied by external stirring easily adapted to the cell, which is demonstrated in this work for NaLVT determination.  相似文献   

20.
In this paper, the time resolution for kinetic studies of reactions with mass spectrometric detection is characterized in detail, and it is shown how this allows faster kinetic processes to be determined. The time‐resolved technique used pulsed laser photolysis to initiate reaction and a time‐of‐flight mass spectrometer (TOFMS) to monitor progress, where the reactant gas was sampled by a sampling orifice and photoionized using pulsed, laser vacuum ultraviolet light before being analyzed by the TOFMS. Characterization of this setup has been carried out to identify the parameters that affect the time for “sampling,” which limits the fastest reactions that can be measured. A simple mathematical equation has been developed to correct for “sampling” delays (ksampling~25, 000 s?1), which extends the range of rate coefficients to be measured in a kinetic mass spectrometry reactor to k′ < 7000 s?1. This method could be applied to any other kinetic mass spectrometry system where ksampling can be measured; an important advantage since it allows the study of reactions over a wider range of conditions (e.g., larger concentrations of reagents/products can be used to minimize the contribution from wall losses). The system can produce reliable kinetic data whether monitoring reactant decay or product growth even when the reaction and sampling processes are occurring on a similar timescale (k′ < 7000 s?1). Reproducible and reliable kinetic data have been obtained for the following reactions: SO + NO2 → products (R1), ClSO + NO2 → products (R2), where SO and ClSO were monitored under pseudo‐first‐order conditions, and HCO + O2 → CO + HO2 (R3), where CO was monitored by a [1+1] resonance enhanced ionization multiphoton ionization (REMPI) scheme with HCO reacting under pseudo–first‐order conditions. The limitations and potential developments of this setup are described. © 2011 Wiley Periodicals, Inc. Int J Chem Kinet 44: 532–545, 2012  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号