首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 482 毫秒
1.
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x 10(-7) M. The response time for the electrode is less than 30 s and the electrode can be used for more than 2 months with less than a 2 mV observed divergence in a potentials. The proposed electrode exhibits very good selectivity for mercury(II) ions over many cations in a wide pH range (pH 1 - 4). The electrode was also applied to the determination of a mercury(II) ion in vegetables and in Azolla filiculoides.  相似文献   

2.
A PVC membrane incorporating p-tert-butyl calix[4]crown with imine units as an ionophore was prepared and used in an ion-selective electrode for the determination of mercury(II) ions. An electrode based on this ionophore showed a good potentiometric response for mercury(II) ions over a wide concentration range of 5.0 x 10(-5) - 1.0 x 10(-1) M with a near-Nernstian slope of 27.3 mV per decade. The detection limit of the electrode was 2.24 x 10(-5) M and the electrode worked well in the pH range of 1.3 - 4.0. The electrode showed a short response time of less than 20 s. The electrode also showed better selectivity for mercury(II) ions over many of the alkali (Na+, -1.69; K+, -1.54), alkaline-earth (Ca2+, -3.30; Ba2+, -3.32), and heavy metal ions (Co2+, -3.67; Ni2+, -3.43; Pb2+, -3.31; Fe3+, -1.82). Ag+ ion was found to be the strongest interfering ion. Also, sharp end points were obtained when the sensor was used as an indicator electrode for the potentiometric titration of mercury(II) ions with iodide and dichromate ions.  相似文献   

3.
A new PVC membrane electrode for cobalt(II) ions based on a recently synthesized Schiff base of 5-((4-nitrophenyl)azo)- N-(2',4'-dimethoxyphenyl)salicylaldimine is reported. The electrode exhibits a Nernstian response for Co(2+) ions over a wide concentration range (9.0 x 10(-7)-1.0 x 10(-2) M) with a slope of 29(+/-1). The limit of detection is 8.0 x 10(-7) M. The proposed sensor revealed good selectivities over a wide variety of other cations including hard and soft metals. This electrode could be used in a pH range of 3.5-6.0. It was used as an indicator electrode in potentiometric titrations of cobalt(II) ions and can be used in the direct determination of Co(2+) in aqueous solutions.  相似文献   

4.
Mercury ion-selective electrodes (ISEs) were prepared with a polymeric membrane based on heterocyclic systems: 2-methylsulfanyl-4-(4-nitro-phenyl)-l-p-tolyl-1H-imidazole (I) and 2,4-diphenyl-l-p-tolyl-1H-imidazole (II) as the ionophores. Several ISEs were conditioned and tested for the selection of common ions. The electrodes based on these ionophores showed a good potentiometric response for Hg2+ ions over a wide concentration range of 5.0 x 10(5-) - 1.0 x 10(-1)M with near-Nernstian slopes. Stable potentiometric signals were obtained within a short time period of 20 s. The detection limits, the working pH range of the electrodes were 1.0 x 10(-5) M and 1.6-4.4 respectively. The electrodes showed better selectivity for Hg2+ ions over many of the alkali, alkaline-earth and heavy metal ions. Also sharp end points were obtained when these sensors were used as indicator electrodes for the potentiometric titration of Hg2+ ions with iodide ions.  相似文献   

5.
A new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0x10(-1)-5.0x10(-6) M with a lower limit of detection of 1.3x10(-6) M. It has a fast response time and can be used for a period of 4 months with a good reproducibility. The sensor is suitable for use in aqueous solutions in a wide pH range of 3.6-7.4 and works satisfactorily in the presence of 25% (v/v) methanol or ethanol. The sensor shows high selectivity to nickel ions over a wide variety of cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for the direct determination of nickel content in real samples: effluent samples, chocolates and hydrogenated oils.  相似文献   

6.
A new PVC membrane electrode for the triiodide ion based on a charge-transfer complex of iodine with 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as a membrane carrier was prepared. The electrode exhibits a Nernstian response for triiodide ions over a wide concentration range (1.0 x 10(-1)-1.0 x 10(-5) M) with a slope of 59.3 +/- 0.9 mV decade(-1) and a detection limit of 6.3 x 10(-6) M. It has a response time of 30 s and can be used for at least 3 months without any divergence in the potential. The potentiometric response is independent of the pH, in the pH range 1.6 - 10.0. The proposed electrode has shown very high selectivity for the triiodide ion over a wide variety of other anions. This electrode was successfully applied as an indicator electrode in the potentiometric titration of ascorbic acid and hydroquinone from pharmaceutical preparations as well as ascorbic acid in orange juice and dissolved O2 in tap water.  相似文献   

7.
A silver ion-selective electrode was prepared with a polymeric membrane incorporating 2,6-bis-methylsulfanyl-[1,3,5]thiadiazine-4-thione as an ionophore, tri-n-butylphosphate (TBP) as a plasticizer and sodium tetraphenylborate (NaTPB) as an additive. The electrode exhibited a near-Nernstian response of 52 mV/decade over a wide linear concentration range of 1.0 x 10(-5) - 1.0 x 10(-1) M with a lower detection limit of 9.77 x 10(-6) M. The electrode exhibited excellent selectivity for silver ion over many of the alkali, alkaline-earth and transition metal ions. The electrode worked well over a wide pH range of 1.77 - 7.13. The response time of the electrode was less than 20 s. The sensor can be applied as indicator electrode for the potentiometric titration of Ag+ ions with Cl- ions.  相似文献   

8.
A polystyrene based membrane of 3,4:12,13-dibenzo-2,5,11,14-tetraoxo- 1,6,10,15-tetraazacyclooctade-cane shows a Nernstian response to Cd(II) ions over a wide concentration range (3.16 x 10(-6) - 1.00 x 10(-1) mol L(-1) with a Nernstian slope of 29.8 mV/decade of concentration, between pH 2.0 and 6.0. This electrode has been found to be chemically inert and of adequate stability with a response time of 20s. The electrode gives reproducible results with a lifetime of 130 days. The membrane works satisfactorily in a partially non-aqueous medium up to a maximum 35% (v/v) content of methanol and ethanol. The practical utility of the proposed chemical sensor has been observed by using it as end-point indicator in the titration of Cd(II) ions with EDTA. The potentiometric selectivity coefficient values indicate that the membrane sensor is highly selective for Cd(II) ions over a number of cations. Small amounts of surfactants do not disturb the functioning of the sensor. This electrode has also been used to estimate cadmium ions in real samples.  相似文献   

9.
A coated-wire ion-selective electrode (CWISE), based on a Schiff base as a neutral carrier, was successfully developed for the detection of Pb(II) in aqueous solution. CWISE exhibited a linear response with a Nernstian slope of 29.4 +/- 0.5 mV/decade within the concentration range of 1.0 x 10(-5) - 1.0 x 10(-1) M lead ion. CWISE has shown detection limits of 5.0 x 10(-6) M. The electrode exhibited good selectivity over a number of alkali, alkaline earth, transition and heavy metal ions. This sensor yielded a steady potential within 10 to 20 s at a linear dynamic range. The electrode was suitable for use in aqueous solutions in a pH range of 2.0 to 5.0. Applications of this electrode for the determination of lead in real samples and as indicator electrode for potentiometric titration of Pb2+ ion using K2CrO4 are reported.  相似文献   

10.
A PVC-based membrane electrode for lead ions based on hexathia-18-crown-6-tetraone as membrane carrier was prepared. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The electrode showed a Nernstian response over a lead concentration range from 1.0 x 10(-6) to 8.0 x 10(-3) M at 25 degrees C, and was found to be very selective, precise and usable within the pH range 3.0-6.0. The electrode was successfully used as an indicator electrode in potentiometric titration of lead ions and in direct determination of lead in water samples.  相似文献   

11.
The potentiometric anion selectivity of two polymer membrane based electrodes (I and II) formulated with two new cyclopalladated amine complexes as the active components are examined. The electrodes exhibit a non-Hofmeister selectivity pattern with a significantly enhanced response towards thiocyanate, iodide and nitrite. The graph potential versus log c is linear over the concentration range 10(-6)-6x10(-2) M thiocyanate with electrode I and 10(-6)-10(-3) M with electrode II; 10(-5)-10(-2) M iodide with electrode I and 10(-3)-6x10(-2) M with electrode II; and 10(-3)-6x10(-2) M nitrite with both electrodes. The influence of the plasticizer and pH are studied. The potentiometric selectivity coefficients for I, II and blank membrane electrodes are reported. The selective interaction between Pd(II) thiocyanate, iodide and nitrite is postulated to be the reason for its higher response.  相似文献   

12.
A highly selective PVC membrane electrode based on a cerium-salen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common organic and inorganic anions. The proposed electrode exhibits a near-Nernstian behavior over a wide concentration range (5.0 x 10(-2) - 8.0 x 10(-6) M) with a slope of 57.5 mV per decade, and a detection limit of 6.0 x 10(-6) M. The electrode has a very fast response time and can be used in the pH range of 3.0 - 1 1.0. It was applied, as an indicator electrode, in potentiometric titration of Ag+ ions.  相似文献   

13.
A highly La(III) ion-selective PVC membrane sensor based on N'-(1-pyridin-2-ylmethylene)-2-furohydrazide (NPYFH) as an excellent sensing material was successfully developed. The electrode shows a good selectivity for La(III) ion with respect to most common cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor exhibits a wide linear response with slope of 19.2 +/- 0.6 mV per decade over the concentration range of 1.0 x 10(-6) - 1.0 x 10(-1) M, and a detection limit of 7.0 x 10(-7) M of La(III) ions. The sensor response is independent of pH in the range of 3.5-10.0. The proposed electrode was applied as an indicator electrode in potentiometric titration of La(III) ion with EDTA.  相似文献   

14.
Abbaspour A  Izadyar A 《Talanta》2001,53(5):1009-1013
A PVC-based membrane of 4-dimethylaminoazobenzene reveals a Nernstian potentiometric response (with slope of 19.5+/-0.6 mV/decade and a correlation coefficient of 0.999) for Cr(III) over a wide concentration range (1.66 x 10(-6)-1.0 x10(-2) mol dm(-3)). The potential of this electrode is independent of pH in the range of 3.0-5.5. It has a fast response time of about 10 s and was used for a period of 3 months with good reproducibility. The detection limits of this membrane electrode was 8 x 10(-7) M. the proposed electrode has been used as an indicator electrode in the potentiometric titration of Cr(III) with EDTA. This sensor exhibits a very good selectivities for Cr(III) over a wide variety of metal ions.  相似文献   

15.
A copper(II) ion-selective PVC membrane sensor based on 2-(1'-(4'-(1'-hydroxy-2'-naphthyl)methyleneamino)butyl iminomethyl)-1-naphthol (BHNB) as a novel Schiff base containing a sensing material has been successfully developed. The sensor exhibits a good linear response of 29 mV per decade within the concentration range of 10(-1)-10(-6) M of Cu2+. The sensor shows good selectivity for copper(II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. The BHNB-based sensor is suitable for use with aqueous solutions of pH 3.5-7.0 and displays minimal interference by Sr(II), Cd(II), Hg(II), Zn(II) and Pb(II), which are known to interfere with other previously suggested electrodes. The proposed membrane electrode was used as a sensor for determining the Cu(II) content in black tea samples. It was also applied as an indicator electrode in the potentiometric titration of Cu2+ ions with EDTA.  相似文献   

16.
A novel poly(vinyl chloride) (PVC) membrane electrode based on naphto-9-crown-3 was prepared and tested for the selective detection of beryllium ions. A suitable lipophilicity of the carrier and appropriate coordination ability were found to be essential for designing an electrode with good response characteristics. A PVC membrane with 9% naphtho-9-crown-3 carrier, 58% o-NPOE plasticizer, 3% tetraphenylborate anionic excluder and 30% poly(vinyl chloride) satisfied these requirements. The proposed sensor displayed a linear response to beryllium over a wide concentration range of 1.0 x 10(-1)-8.0 x 10(-6) M with a Nernstian slope of 29.5 mV per decade. The electrode showed very short response time (<15 s) and could be used in the pH range 3.5-9.0. The selectivity coefficient for alkali, alkaline earth, transition and heavy metal ions was smaller than 4.0 x 10(-4). The sensor was successfully used as an indicator electrode in the potentiometric titration of Be2+ with EDTA. The proposed Be(II) sensor was also used for the determination of Be2+ ions in binary mixtures.  相似文献   

17.
The potentiometric response characteristics of cesium ion selective PVC membrane electrode employing calix[4]crown ether-ester as an ionophore were investigated. The electrode exhibit a good response for cesium ion over wide concentration range of 5.0x10(-6)-1.0x10(-1) M with a Nernstian slope of 59 mV per decade. The detection limit of electrode is 5.0x10(-6) M. The electrode was found to have selectivity for cesium ion over alkali, alkaline and transition metals. The response time of the electrode is less than 20 s and can be used for more than 4 months without observing any divergence in potentiometric response. The electrode response was stable over wide pH range.  相似文献   

18.
A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0. The electrode shows a linear response for Ag+ ion over the concentration range of 1.0 x 10(-60 to 1.0 x 10(-1) M with a lower detection limit of 6.0 x 10(-7) M. The electrode possesses a Nernstian slope of 59.7 mV decade(-1) and a fast response time of < or = 17 s and can be used for at least 2 months without any observable deviation. The proposed electrode displayed very good selectivity for Ag+ ion with respect to NH4+ and alkali, alkaline earth and some common transition metal ions. The practical utility of the electrode has been demonstrated by its use as the indicator electrode in the potentiometric titration of an AgNO3 solution with a NaI solution and in determination of the silver content of a developed radiological film.  相似文献   

19.
The complexation of five recently synthesized hydroxy-thioxanthone derivatives with Al3+ ion was studied in a methanol solution spectrophotometrically, and the stepwise formation constants of the resulting 1:1 and 2:1 (ligand-to-metal) complexes were evaluated. The suitability of the thioxanthone derivatives as neutral ionophores for the preparation of a new Al3+ ion-selective PVC-membrane electrode was investigated, and 1-hydroxy-3-methyl-thiocanthone was selected as the best compound for this purpose. The prepared electrode exhibits a Nernstian response for Al3+ ions over a wide concentration range (2.0 x 10(-2) to 2.0 x 10(-6) M), with a limit of detection of 1.0 x 10(-6) M. It has a very fast response time of about 5 s and can be used for at least 3 months without any considerable divergence in the potentials. The proposed membrane sensor revealed very good selectivities for Al3+ over a wide variety of other metal ions, and could be used at a working pH range of 3.4 - 5.0. It was used as an indicator electrode in potentiometric titration of aluminum ions with EDTA, and in the determination of Al3+ in different real samples.  相似文献   

20.
A new carbon paste electrode (CPE) for the determination of iodide ion based on a cetyltrimethylammonium iodide (CTMAI) ion pair as an electroactive material is described. The electrode shows a linear response for iodide ion over the concentration range of 4 x 10(-5) M to 1 x 10(-1) M with a lower detection limit of 4 x 10(-5) M at 25 degrees C. The electrode has a Nemstian slope of -55.0 +/- 0.4 mV/decade and a fast potential response of 45 s, which is almost constant over a pH range of 5.0 - 9.0. Selectivity coefficient data of the CTMAI-CPE for some common ions show negligible interference, and the electrode has high selectivity towards the iodide ion. An average recovery of 101.83% with a relative standard deviation of 1.53% has been achieved for the determination of iodide in Flaxedil (gallamine triethiodide) ampoules, a muscle relaxant drug. The electrode has been examined for the determination of iodide in saline water; the results were found to compare favorably with those obtained using Metrohm iodide ISE. The electrode has been utilized as an end-point indicator electrode for the determination of Hg(II) and phenylmercury(I) in their aqueous solutions using potentiometric titration with a potassium iodide standard solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号