首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A simple and reliable method for the determination of arsenic in sediment and in coal without sample digestion, based on hydride generation from slurry samples is proposed. After grinding the samples to a particle size of 50 μm, the sample powder was mixed with aqua regia and hydrofluoric acid in an ultrasonic bath for 30 min. After diluting the mixture with hydrochloric acid, the slurry was allowed to stand for 48 h, and an aliquot was used for hydride generation with sodium borohydride. More than 80% of the arsenic was leached to the aqueous phase under these conditions, except for one sediment sample with very high silica content. The generated arsine was collected in a graphite tube, treated with 0.5 mg of iridium as a permanent modifier, and the arsenic determination was carried out by electrothermal atomic absorption spectrometry. The same tube could be used for at least 160 cycles without any re-treatment. The greatest advantage of the method was that only a minimum of reagents and sample handling were required, reducing the risks of contamination and/or analyte loss. However, the addition calibration technique had to be used in order to obtain results within the 95% confidence level for 11 certified reference materials, 5 sediments, 5 coals and one coal fly ash. One certified sediment slurry was spiked with the analyte and the resulting addition calibration curve was used for the analysis of the certified sediments. Similarly, one certified coal was used to obtain the addition calibration curve for the coal and coal fly ash samples. The recoveries of the certified values, except for one sediment, were between 91 and 115%. The limits of detection in the samples were 0.54 and 0.7 μg g−1 for the coal and sediment samples, respectively, obtained for 1 ml of slurry containing 1 mg of sample.  相似文献   

2.
A novel, rapid and simple method by hydride generation-electrothermal atomic absorption spectrometry (HG-ETAAS) after direct As, Bi, Sb and Sn hydrides generation from untreated filters of atmospheric particulate matter (PM10 and PM2.5) was optimised. PM10 and PM2.5 were not subjected to any pre-treatment: circular portions between 0.28 and 6.28 cm2 were directly placed into the reaction vessel of a batch mode generation system. A 28 × 3/64 Plackett–Burman design was used as a multivariate strategy for the evaluation of the effects of several variables affecting the hydride generation, trapping and atomisation efficiencies. Trapping temperature was the most statistically significant variable for As, Bi and Sn. Atomisation temperature was also statistically significant for Sb determination. Optimum values of significant variables were selected by using univariate optimisation approaches. An aqueous calibration method was used throughout. The developed method has been found to be precise with relative standard deviations of 6.2, 5.3, 9.1 and 7.5% for 11 determinations in a filter sample containing 0.7, 1.0, 1.4 and 1.7 μg l−1 for As, Bi, Sb and Sn, respectively. Results obtained by direct solid sampling-HG-ETAAS have been found statistically comparable with those obtained after conventional method based on an acid digestion followed to ICP-MS. Absolute detection limits were 37, 15, 30, and 41 ng l−1 for As, Bi, Sb and Sn, respectively. Detection limits referred to the air volume sampled (in the range of 0.020–0.050 ng m−3) were low enough for the determination of several hydride-forming elements from PM10 and PM2.5 samples collected in a non-polluted suburban area of A Coruña (NW Spain).  相似文献   

3.
Thallium hydride was generated from aqueous solutions by merging sample and sodium tetrahydroborate reductant in a batch system. In situ preconcentration of volatile thallium hydride in a preheated graphite furnace coated with palladium, which was used as both the collection medium and atomizer, greatly improved the sensitivity for the determination of thallium by hydride generation atomic absorption spectrometry. The presence of tellurium can increase the generation efficiency of thallium hydride. The operating conditions were optimized. The calibration graph is linear up to 100 ng and the characteristic mass for thallium was 0.92 ng which is seventeen times lower than that obtained with the heated quartz tube atomizer.  相似文献   

4.
A supported liquid membrane system has been developed for the extraction of vanillin from food samples. A porous PTFE membrane is impregnated with an organic solvent, which forms a barrier between two aqueous phases. The analyte is extracted from a donor phase into the hydrophobic membrane and then back extracted into a second aqueous solution, the acceptor. The determination (100–1400 μg ml−1 vanillin) was performed using a PVC-graphite composite electrode versus Ag/AgCl/3MKCl at +0.850 V placed in a wall-jet flow cell as amperometric detector. The solid sample is directly placed in the membrane unit without any treatment, and the analyte was extracted from the sample, passes through the membrane and conduced to the flow cell by the acceptor stream. The limit of detection (3σ) was 44 μg ml−1. The method was applied to the determination of vanillin (9–606 μg g−1) in food samples.  相似文献   

5.
Zanjanchi MA  Noei H  Moghimi M 《Talanta》2006,70(5):933-939
Diffuse reflectance spectroscopy (DRS) can be used as a rapid and sensitive method for the quantitative determination of low amounts of aluminum. In this analytical technique, the analyte in samples are extracted onto a solid sorbent matrix loaded with a colorimetric reagent and then quantified directly on the adsorbent surface. Alternatively, colored aluminum complexes formed in solution can also be immobilized onto adsorbent surface and be measured by DRS technique. Octadecyl silica disk, methyltrioctylammonium chloride–naphthalene and MCM-41 were examined as adsorbents. Eriochrome cyanine R and quinalizarin were used as coloring reagents. Optimal sorption conditions were found for each system of analyte–reagent–adsorbent. The concentration of analyte is determined using the appropriate form of the Kubelka–Munk function. We obtained for each of the aluminium–reagent–adsorbent system a calibration curve by plotting the absorbance versus the log 102[Al3+] μg ml−1. The linear dynamic range extends over two orders of magnitude within 0.01–15 μg ml−1 with little differences in the range and in the correlation coefficients among the adsorbents. We consider that for a rapid determination of aluminum a spot-test-DRS combination with a detection limit of 1.0 × 10−2 μg ml−1 is the more facile and preferred technique.  相似文献   

6.
Wei Y  Oshima M  Simon J  Moskvin LN  Motomizu S 《Talanta》2002,58(6):1343-1355
The concentration distribution of an analyte in a chromatomembrane cell (CMC) was examined by using various air samples of different air pollutant (NO2) concentrations and volumes, and the results obtained could be explained by a proposed principle of the concentration distribution of the analyte in the CMC. This principle was for the first time proved experimentally in the present study. On-line preconcentration and continuous determination of the air pollutant (NO2) in air samples were realized by coupling a three-hole CMC with a flow injection analysis (FIA) system, where a triethanolamine (TEA) aqueous solution (2 g l−1) was used as an absorbing solution for NO2 in the air samples. A calibration method with standard nitrite aqueous solutions was developed for the determination of NO2 in the air samples. Concentrations of NO2 in indoor air and its diluted air samples were determined by the proposed CMC/FIA method. The volume of air sample necessary for the measurement was decreased to only 5 ml. The measuring time for one sample was about 5–6 min even when a 20 ml air sample was used.  相似文献   

7.
A flow injection (FI) on-line preconcentration procedure for ultra-trace inorganic selenium was developed with detection by atomic fluorescence spectrometry. Selenium (IV) is co-precipitated with lanthanum hydroxide and collected on a PTFE beads packed column, the precipitate is afterwards dissolved with hydrochloric acid followed by hydride generation with reduction by tetrahydroborate. A thorough scrutiny was made for chemical variables and FI parameters. With a sampling volume of 3.4 ml, quantitative retention of selenium (IV) was obtained, along with an enrichment factor of 11 and a sampling frequency of 38 h− 1. The detection limit, defined as 3 times the blank standard deviation (3σ), was 5 ng l− 1. The precision was characterized by a RSD value of 1.2% (at the 0.5 μg l− 1 level, n = 11). The enrichment factor was further enhanced to 20 along with a detection limit of 3 ng l− 1, with a sample loading volume of 6.8 ml. The procedure was validated with certified reference materials and biological samples. It was also applied to the speciation of inorganic selenium in surface waters.  相似文献   

8.
Cadmium concentration in lake sediments is determined by suspending the solid samples in a solution containing 5% (v/v) concentrated nitric acid and 0.1% (v/v) Triton X-100. Three modifiers were tested for the direct determination. The furnace temperature programmes and appropriate amount for each modifier were optimised to get the highest signal and the best separation between the atomic and background signals. The drying stage is performed by programming a 400 °C temperature, a ramp time of 25 s and hold time of 10 s on the power supply of the atomiser. No ashing step is used and platform atomisation is carried out at 2200 °C. W–Rh permanent modifier combined with conventional modifier by delivering 10 μl of 0.50% (w/v) NH4H2PO4 solution was the best chemical modifier for cadmium determination. This modifier also acts as a liquid medium for the slurry, thus simplifying the procedure. Calibration is performed using aqueous standards in the 1–5 μg l−1 range. The optimised method gave a limit of detection of 0.56 ng ml−1, characteristic mass of 10.1±0.8 pg for aqueous standard, 9.6±0.7 pg for slurry samples containing different Cd concentrations and good precision (7.6–5.2%). The method was validated by analysing four certified reference lake sediment materials: LKSD-1, LKSD-2, LKSD-3 and LKSD-4; satisfactory recoveries were obtained (90.0–96.3%) and no statistical differences were observed between the experimental and the certified cadmium concentration. The developed methodology was used to determine cadmium in three ‘real’ sediment samples from lakes in the area of Wielkopolski National Park, Poland.  相似文献   

9.
A procedure for the determination of As, Pb, Se and Sn in sediment slurries by electrothermal vaporization inductively coupled plasma mass spectrometry is proposed. The slurry, 1 mg ml−1, is prepared by mixing the sample ground to a particle size 50 μm with 5% v/v nitric and 1% v/v hydrofluoric acids in an ultrasonic bath. The slurry was homogenized with a constant flow of argon in the autosampler cup, just before transferring an aliquot to the graphite furnace. The tube was treated with Ru as a permanent modifier, and an optimized mass of 1 μg of NaCl was added as a physical carrier. The pyrolysis temperature was optimized through pyrolysis curves, and a compromised temperature of 800 °C was used; the vaporization temperature was 2300 °C. The effect of different acid concentrations in the slurry on the analyte signal intensities was also evaluated. The accuracy of the method was assured by the analysis of certified reference sediments MESS-2, PACS-2 and HISS-1 from the National Research Council Canada, SRM 2704 and SRM 1646a from the National Institute of Standards and Technology and RS-4 from a round robin test, using external calibration with aqueous standards prepared in the same medium as the slurries. The obtained concentrations were in agreement with the certified values according to the Student's t-test for a confidence level of 95%. The detection limits in the samples were: 0.17 μg g−1 for As; 0.3 μg g−1 for Pb; 0.05 μg g−1 for Se and 0.28 μg g−1 for Sn. The precision found for the different sediment samples, expressed as R.S.D. was 1–8% for As, 2–9% for Pb, 6–12% for Se and 3–8% for Sn (n=5).  相似文献   

10.
Composite diazotization-coupling reagents containing sulfanilamide (SAM), sulfapyridine (SP) or sulfathiazole (ST) as the diazotizable aromatic amines and sodium 1-naphthol-4-sulfonate (NS) as the coupling agent using column preconcentration on naphthalene-tetradecyldimethylbenzylammonium(TDBA)-iodide adsorbent have been used for the spectrometric determination of trace nitrate and nitrite in soil and water samples. Nitrite ion reacts with SAM in the pH range 2.0–5.0, SP in the pH range 2.0–2.5 and ST in the pH range 2.0–3.3 in HCl medium to form water-soluble colourless diazonium cations. These cations were coupled with NS in the pH range 9.0–12.0 for the SAM system, 9.6–12.0 for the SP system and 8.5–12.0 for the ST system to be retained on naphthalene-TDBA-I material packed in a column. The solid mass is dissolved from the column with 5 ml of dimethylformamide and the absorbance is measured spectrometerically at 543 nm for SAM-NS, 533 nm for SP-NS and 535 nm for ST-NS. Nitrate is reduced to nitrite by a copper-coated cadmium reductor column and the nitrite is then treated with the diazotization-coupling reagent by column preconcentration. The absorbance due to the sum of nitrate and nitrite is measured and nitrate is determined by difference. The calibration graph was linear over the range 2–40 ng NO2-N ml−1 and 1.5–30 ng NO3-N ml−1 in aqueous samples for the SAM and ST systems and 2–48 ng NO2-N ml−1 and 1.5–36 ng NO3-N ml−1 in aqueous samples for the SP system, respectively. The sensitivity, accuracy and precision of the systems decreased in the order STSAMSP. The detection limits were 1.4 ng NO2-N ml−1 and 1.1 ng NO3-N ml−1 for SAM, 1.6 ng NO2-N ml−1 and 1.2 ng NO3-N ml−1 for SP, and 1.0 ng NO2-N ml−1 and 0.75 ng NO3-N ml−1 for ST, respectively. The preconcentration factors are 8, 5 and 6 for SAM-NS, SP-NS and ST-NS, respectively. Interferences from various foreign ions have been studied and the methods have been applied to the determination of ng ml−1 levels of nitrite and nitrate in soil and water samples. The mean recovery was 95–102% for all three systems.  相似文献   

11.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

12.
This paper describes a method for the simultaneous determination of As(III), Sb(III) and Se(IV) by combining hydride generation and gas phase molecular absorption spectrometry. A system for continuous hydride generation has been designed and developed, based on the use of a double process of gas-liquid separation, and optimal compromise operation conditions for the three compounds have been found. After generation, the hydrides are collected in a liquid nitrogen cryogenic trap, and then evaporated and driven to the flow cell of a diode array spectrophotometer, in which the transient signals over the 190–250 nm wavelength interval are measured. Under the recommended conditions (sample flow: 35 ml min−1, 0.5 M HCl; reductor flow: 4 ml min−1 of 4% NaBH4, solution) linear response ranges above 50 μg 1−1 for As(III), 30 μg 1−1 for Sb(III) and 200 μg 1−1 for Se(IV) are obtained with detection limits of 22 μg 1−1, 15 μg 1−1 and 65 μg 1−1, respectively. Multiwavelength linear regression equations were used for the simultaneous determination of the three elements in different synthetic samples, with good precision and accuracy and to study simultaneously the interference from different chemical species for the three compounds. Results were similar to those obtained by other techniques using hydride generation.  相似文献   

13.
Moneeb MS 《Talanta》2006,70(5):1035-1043
Polarographic chemometric methods were applied to the determination of zinc and nickel in aqueous solutions previously acidified with 0.1 M acetate buffer (pH 4.2). The studied methods are multivariate methods including classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS); derivative ratio methods (first, 1D and second, 2D derivative ratio). A comparative study was considered. The studied chemometric methods do not need the presence of any reduction potential shift reagent in spite of the great overlap between the two metals polarograms. A training set consisting of 10 binary mixture solutions in the possible combinations containing 0.13–9.30 μg/ml Zn(II) and 0.20–12.25 μg/ml Ni(II) was used to develop the chemometric calibrations (CLS, PCR and PLS). A validation set containing the synthetic mixtures in the range of 0.29–9.00 μg/ml for Zn(II) and 0.30–11.60 μg/ml for Ni(II) was used to validate the multivariate calibrations. Same mixtures were used to develop the derivative ratio methods. The polarograms were recorded and their current values were measured within the potential range −920 to −1052 mV at 2 mV intervals. The mean percentage recoveries obtained using CLS, PCR and PLS were found to be 99.5 ± 1.5%, 100.0 ± 1.1% and 100.0 ± 1.0% for Zn(II) and 99.4 ± 1.3%, 99.7 ± 1.2% and 99.9 ± 1.0% for Ni(II), respectively. The mean percentage recoveries obtained using 1D at −950 mV, 1D at −1010 mV, 1D at −950 mV–1D at −1010 mV and 2D at −986 mV for Zn(II) were found to be 99.7 ± 1.2%, 99.2 ± 1.6%, 99.4 ± 1.4% and 99.4 ± 1.4%; and using 1D at −1030 mV and 2D at −1010 mV for Ni(II) were found to be 100.5 ± 1.3% and 100.4 ± 1.3%, respectively. Interferences due to the presence of Cd, Co, Pb, Fe, Mn, Ca, Mg, Cu and Al were studied. The applicability of the proposed methods was assessed through the determination of both metals in tap drinking-water. Samples were subjected if required up to a 20-fold preconcentration step by microwaving in pyrex vessels. The results were compared with those obtained using the zincon and the heptoxime colorimetric reference methods for the determination of zinc and nickel, respectively.  相似文献   

14.
A novel pervaporation-flow injection (PFI) system for the determination of As(III) in aqueous samples at μg l−1 level is described. The analytical procedure involved stopping the acceptor stream and injecting acidified As(III) samples into a 0.3 M HCl stream which was mixed with a 0.14 M sodium borohydride in 0.025 M NaOH stream. The arsine generated was transported in the pervaporation unit across a semi-permeable membrane (1.5 mm thickness) into the static acceptor solution containing 1.0×10−4 M KMnO4 in 0.1 M H2SO4 where it was oxidised. The acceptor stream was restarted after 6.5 min, and the decrease in permanganate absorbance at 528 nm was monitored to determine the initial concentration of As(III) in the samples. The method is characterised by a linear calibration range from 0.25 to 2000 μg l−1, a detection limit of 0.18 μg l−1 and a sampling frequency of 7 h−1. Samples containing As(V) were pre-treated with KI and HCl prior to injection to reduce As(V) to As(III). The effects of common anionic and cationic interferences, and the elimination of some metallic interferences using -cysteine are discussed. The method was applied to the analysis of environmental waters and the results were in good agreement with hydride generation atomic absorption spectrometric data.  相似文献   

15.
Colloidal palladium was used as a chemical modifier for analysis of complex samples by electrothermal atomic absorption spectrometry. In order to demonstrate high potential of the modifier, optimization of the time–temperature program of the atomizer was limited with only pyrolysis and atomization temperatures. Fixed palladium modifier masses were applied (6 μg for pure analyte solutions and 15 μg for matrix-containing solutions). It was shown that in the presence of colloidal palladium, interference-free determinations of As, Sb and Pb are possible up to at least 450 μg of chloride ion, or 40 μg of sulfate ion (as their sodium salts) in the atomizer. Colloidal palladium was used for the direct determination of As, Sb and Pb in a spiked sea water sample (from Bosphorus channel near Istanbul) by means of the calibration graphs prepared with pure analyte solutions. The detection limits for As, Sb and Pb in a sea water matrix calculated according to 2σ criteria are 5.4, 3.6 and 1.1 ng ml−1, respectively (for sample volume 10 μl). In unspiked sea water, the contents of As, Sb and Pb were found to be below the detection limits. Recoveries of spiked analytes (25 and 50 ng ml−1) were in the region of 98–112% depending on the nature of analyte and the concentration of spike.  相似文献   

16.
A flat sheet membrane desolvator (FSMD) was used to extend the applicability of a 120 W helium microwave induced plasma (He-MIP) to elemental analysis of organic-solvent-based samples and element selective liquid chromatographic detection. With the FSMD on-line, methanol could be nebulized with a sample flow rate of 1.5 ml/min and a carrier gas flow rate of 1.2 l/min without extinguishing the plasma. Under these conditions, applying desolvator countercurrent gas flows in the range 0–8 l/min restored of the original pink color of the pure helium MIP from the bluish-green caused by methanol. Significant reductions in the emission intensities of C2 species at 436.5, 473.7, 512.9, and 563.6 nm were observed with the application of the FSMD. The intensities of chlorine analyte emission lines at 479.5, 481.0 and 481.9 nm increased with increasing countercurrent gas flow rates and reached a maximum intensity with a flow rate of 5.0 l/min. Detection limits for Cl and Pb were 2.1 and 0.1 ppm using a 1 m focal length monochromator. Other elements and solvent combinations were also examined. Element selective liquid chromatographic detection was preliminarily examined by monitoring 2,6-dichlorobenzene and 5,7-dichlorohydroxyquinoline at the 479.5 nm Cl atomic emission line. Chlorine detection limits in the 3–7 μg range (70–190 ng/s) were obtained.  相似文献   

17.
A method for the determination of As, Hg, Sb, Se and Sn in environmental and in geological reference materials, as acidified slurries, by flow injection (FI) coupled to a hydride generation system (HG) and detection by inductively coupled plasma mass spectrometry (ICP-MS) is proposed. The HG unit has a gas liquid separator and a drying unit for the generated vapor. The slurries were prepared by two procedures. Approximately 50 mg of the reference material, ground to a particle size ≤50 μm, was mixed with acid solutions in an ultrasonic bath. In Procedure A, the medium was a hydrochloric acid solution while in Procedure B, the medium was aqua regia plus a hydrochloric acid solution. The conditions for the slurry formation and the instrumental parameters were optimized. Harsh conditions were used in the slurry preparation in order to reduce the hydride forming analytes to their lower oxidation states, As (III), Se(IV), Sb(III) and Sn(II), before reacting with sodium tetrahydroborate. To test the accuracy, 10 certified reference materials were analyzed (four sediments, three coals, one coal fly ash and two sewage sludges), with the analyte concentrations mostly in the μg g−1 level. Good agreements with the certified values were obtained for Hg, Sb and Sn in the sediments using Procedure A and calibration against aqueous standard solutions. Using Procedure B, good results were obtained for Hg, Se and Sn in the sediment samples, for Se in the coal and coal fly ash samples and for Hg in the sewage sludge samples, also using external calibration with aqueous standard solutions. For As in sediments, coals and coal fly ash, Procedure B and the analyte addition calibration was required, indicating matrix effects. The relative standard deviations were lower than 5%, demonstrating a good precision for slurry analysis. The limits of quantification (10 times the standard deviation; n=10), in the samples, in ng g−1, were: 20 for As, 60 for Hg, 80 for Sb, 200 for Se and 90 for Sn. The method requires small amounts of reagents and reduces contamination and losses.  相似文献   

18.
Cao Q  Li S  He C  Li K  Liu F 《Analytica chimica acta》2007,590(2):187-194
Based on aqueous two-phase system (ATPS) of poly(ethylene glycol) (PEG)–(NH4)2SO4, a simple pretreatment approach was developed for the extraction and determination of papaverin in pericarpium papaveris. The influence factors on phase behavior of the ATPS and partition behavior of papaverin was investigated, and partition mechanism based on the hydrophobic interaction between PEG and analyte molecules was proposed. Under the optimal conditions, the extraction efficiencies for papaverin were 93–96%, and the recoveries of the added standard were 97–106% with relative standard deviations of 1.8–2.5%. Combined with a high-performance liquid chromatography (HPLC) method, this extraction technique has been successfully applied to the determination of papaverin in pericarpium papaveris with the detection limit of 2 ng mL−1 and the linear range of 0.10–10 μg mL−1. Compared with the conventional liquid–liquid extraction or solid-phase extraction, this method was more environmentally benign, more cost effective and much simpler due to the direct injection of the upper phase into HPLC system.  相似文献   

19.
Analytical procedure for the determination of toxicologically relevant arsenic (the sum of arsenite, arsenate, monomethylarsonate and dimethylarsinate) in urine by flow injection hydride generation and collection of generated inorganic and methylated hydrides on an integrated platform of a transverse-heated graphite atomizer for electrothermal atomic absorption spectrometric determination (ETAAS) is elaborated. Platforms are pre-treated with 2.7 μmol of zirconium and then with 0.10 μmol of iridium which serve both as an efficient hydride sequestration medium and permanent chemical modifier. Arsine, monomethylarsine and dimethylarsine are generated from diluted urine samples (10–25-fold) in the presence of 50 mmol L−1 hydrochloric acid and 70 mmol L−1 l-cysteine. Collection, pyrolysis and atomization temperatures are 450, 500, 2100 and 2150 °C, respectively. The characteristic mass, characteristic concentration and limit of detection (3σ) are 39 pg, 0.078 μg L−1 and 0.038 μg L−1 As, respectively. The limits of detection in urine are ca. 0.4 and 1 μg L−1 with 10- and 25-fold dilutions. The sample throughput rate is 25 h−1. Applications to several urine CRMs are given.  相似文献   

20.
The heat capacity of copper hydride has been measured in the temperature range 2–60 and 60–250 K using two adiabatic calorimeters. Special procedure for the purification of CuH has been applied and a careful analysis of sample contamination has been performed. The experimental results have been extrapolated up to 300 K due to instability of the copper hydride at room temperature. From the temperature dependence of heat capacity the values of entropy S°(T), thermal part of enthalpy H°(T)−H°(0) and Gibbs function [−(G°(T)−H°(0))] have been calculated assuming S°(0)=0. The standard absolute entropy, standard entropy of formation from the elements and enthalpy of decomposition of copper hydride from the elements have been calculated and found to be 130.8 J K−1 mol−1 (H2), −85.1 J K−1 mol−1 (H2), −55.1 kJ mol−1 (H2), respectively. These new results gave the possibility of discussion on thermodynamic properties of copper hydride. Debye temperature has been for the first time determined experimentally.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号