首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of ziprasidone (ZIP) in human plasma was developed. ZIP and N-methyl ziprasidone as internal standard (IS) were extracted from alkalinized plasma using tert- butyl methyl ether. Separation was performed isocratically on a C8 column with 90% acetonitrile containing 2 mmol/L ammonium acetate as a mobile phase with a total run time of 2.5 min. MS/MS transitions of m/z 413 --> 194 and m/z 427 --> 177 of the analyte and internal standard were used for quantification. Confirmatory ions of m/z 413 --> 177 and m/z 427 --> 180 were collected as well. The calibration curve based on peak-area ratio was linear up to at least 200 ng/mL with a detection limit of 0.1 ng/mL. The method showed satisfactory reproducibility with a coefficient of variation of less than 5%. The method was successfully applied to the analysis of ZIP in spiked human plasma.  相似文献   

2.
A simple, rapid and reliable liquid chromatography–electrospray ionization tandem mass spectrometry method was established and validated for the determination of methotrexate in human plasma. After a straightforward protein precipitation by acetonitrile–water (70:30, v/v), methotrexate (MTX) and p‐aminoacetophenone (used as internal standard, IS) were separated on a Column C18 column (50 × 2.1 mm, 3 µm; Column Technology, Fremont, CA, USA) using a gradient elution with mobile phase of acetonitrile and 0.03% acetic acid aqueous solution at a flow rate of 0.5 mL/min. The total chromatographic runtime was 5 min for each injection. Quantification detection was performed in a triple‐quadruple tandem mass spectrometer under positive mode monitoring the following mass transitions: m/z 455.3 → 308.3 for MTX and m/z 136.1 → 94.4 for IS. The calibration curve was linear over the range of 0.05–25.0 µmol/L with a lower limit of quantification of 0.05 µmol/L. The intra‐ and interday precisions were <5.2%, the accuracy varied from ?4.1 to 4.5%. The recovery was >94%. The LC‐MS/MS method showed an excellent agreement with the existing HPLC‐UV method using Passing–Bablok regression and Bland–Altman difference plot analysis. The validated LC‐MS/MS can be successfully applied to the routine therapeutic drug monitoring of MTX in clinical laboratories. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
The interest in therapeutic drug monitoring has increased over the last few years. Inter‐ and intra‐patient variability in pharmacokinetics, plasma concentration related toxicity and success of therapy have stressed the need of frequent therapeutic drug monitoring of the drugs. A sensitive, selective and rapid liquid chromatography coupled with tandem mass spectrometry (LC‐MS/MS) method was developed for the simultaneous quantification of acetylsalicylic acid (aspirin), salicylic acid, clopidogrel and carboxylic acid metabolite of clopidogrel in human plasma. The chromatographic separations were achieved on Waters Symmetry ShieldTM C18 column (150 × 4.6 mm, 5 µm) using 3.5 mm ammonium acetate (pH 3.5)–acetonitrile (10:90, v/v) as mobile phase at a flow rate of 0.75 mL/min. The present method was successfully applied for therapeutic drug monitoring of aspirin and clopidogrel in 67 patients with coronary artery disease. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
The aim of this study was to improve and validate a more stable and less time‐consuming method based on liquid chromatography and tandem mass spectrometry (LC‐ MS/MS) for the quantitative measurement of imatinib and its metabolite N‐ demethyl‐imatinib (NDI) in human plasma. Separation of analytes was performed on a Waters XTerra RP18 column (50 × 2.1 mm i.d., 3.5 μm) with a mobile phase consisting of methanol–acetonitrile–water (65:20:15, v /v/v) with 0.05% formic acid at a flow‐rate of 0.2 mL/min. The Quattro MicroTM triple quadruple mass spectrometer was operated in the multiple‐reaction‐monitoring mode via positive electrospray ionization interface using the transitions m /z 494.0 → 394.0 for imatinib, m /z 479.6 → 394.0 for NDI and m /z 488.2 → 394.0 for IS. The method was linear over 0.01–10 μg/mL for imatinib and NDI. The intra‐ and inter‐day precisions were all <15% in terms of relative standard deviation, and the accuracy was within ±15% in terms of relative error for both imatinib and NDI. The lower limit of quantification was identifiable and reproducible at 10 ng/mL. The method was sensitive, specific and less time‐consuming and it was successfully applied in gastrointestinal stromal tumor patients treated with imatinib.  相似文献   

5.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

6.
Therapeutic drug monitoring of antiepileptic drugs is widely practiced to achieve optimal efficacy and avoid adverse side effects. We describe an ultra‐high‐performance liquid chromatography tandem mass spectrometry (UHPLC/MS/MS) method developed for the monitoring of four frequently prescribed antiepileptic drugs – lamotrigine, levetiracetam, oxcarbazepine and topiramate. The main pharmacologically active metabolite of oxcarbazepine (mono‐hydroxy‐derivative metabolite, MHD) was also quantified. After addition of internal standards and a simple stage of protein precipitation, plasmatic samples were analyzed on a C18 column. All antiepileptic drugs were separated and quantified in 6 min, without interference. A good linearity was observed all over the calibration range (r2 > 0.99), up to 20 μg/mL (40 μg/mL for MHD). The limit of quantification was 0.20 μg/mL (0.40 μg/mL for MHD) with precision and accuracy ranging from 1.0 to 2.1% and from 96.7 to 110.8%, respectively. Intra‐ and inter‐day precision and accuracy values were within 15%. No significant matrix effect was observed for all analytes. Clinical application was successfully evaluated in 259 samples from patients treated for epilepsy or bipolar disorders. In conclusion, a rapid, specific and sensitive UHPLC/MS/MS method was developed and validated for simultaneous quantification of antiepileptic drugs, suitable for therapeutic drug monitoring in neurology and psychiatry.  相似文献   

7.
A simultaneous, selective, sensitive and rapid liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of gefitinib, erlotinib and afatinib in 250 μL samples of human blood plasma. Diluted plasma samples were extracted using a liquid‐phase extraction procedure with tert‐butyl methyl ether. The three drugs were separated by high‐performance liquid chromatography using a C18 column and an isocratic mobile phase running at a flow rate of 0.2 mL/min for 5 min. The drugs were detected using a tandem mass spectrometer with electrospray ionization using imatinib as an internal standard. Calibration curves were generated over the linear concentration range of 0.05–100 nm in plasma with a lower limit of quantification of 0.01 or 0.05 nm for all compounds. Finally, the validated method was applied to a clinical pharmacokinetic study in patients with nonsmall‐cell lung cancer (NSCLC) following the oral administration of afatinib. These results indicate that this method is suitable for assessing the risks and benefits of chemotherapy in patients with NSCLC and is useful for therapeutic drug monitoring for NSCLC treatment. As far as we know, this is the first report on LC‐MS/MS method for the simultaneous quantification of NSCLC tyrosine kinase inhibitor plasma concentrations including afatinib. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
The purpose of this study was to develop an ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method of 22 antiepileptics for routine therapeutic monitoring. The antiepileptics used in the analyses were carbamazepine, carbamazepine‐10,11‐epoxide, clobazam, N‐desmethylclobazam, clonazepam, diazepam, N‐desmethyldiazepam, ethosuximide, felbamate, gabapentin, lamotrigine, levetiracetam, N‐desmethylmesuximide, nitrazepam, phenobarbital, phenytoin, primidone, tiagabine, topiramate, valproic acid, vigabatrin and zonisamide. After protein precipitation of 50 μL plasma with methanol, the supernatant was diluted with water or was evaporated to dryness and reconstituted with mobile phase in the case of benzodiazepines. Separation was achieved on an Acquity UPLC BEH C18 column with a gradient mobile phase of 10 mm ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.4 mL/min. An Acquity TQD instrument in multiple reaction monitoring mode with ion mode switching was used for detection. All antiepileptics were detected and quantified within 10 min, with no endogenous interference. All the calibration curves showed good linearity in the therapeutic range (r2 < 0.99). The precision and accuracy values for intra‐ and inter‐assays were within ±15% except for phenobarbital and tiagabine. A good correlation was observed between the concentration of clinical samples measured by the new method described here and the conventional methods. The values of carbamazepine and phenytoin by UPLC‐MS/MS were lower than those detected by the immunoassays, which might be caused by the cross‐reaction of antibodies with their metabolites. In conclusion, we developed a simple and selective UPLC‐MS/MS method suitable for routine therapeutic monitoring of antiepileptics. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
To support pharmacokinetic‐guided dosing in individual patients, a fast and accurate method for simultaneous determination of anticancer tyrosine kinase inhibitors (TKIs) dasatinib, erlotinib, gefitinib, imatinib, lapatinib, nilotinib, sorafenib and sunitinib in human plasma was developed using high‐performance liquid chromatography and detection with tandem mass spectrometry (HPLC‐MS/MS). Stable isotopically labeled compounds of the eight different TKIs were used as internal standards. Plasma proteins were precipitated and an aliquot of supernatant was directly injected onto a reversed phase chromatography system consisting of a Gemini C18 column (50 × 2.0 mm i.d., 5.0 µm particle size) and then compounds were eluted with a gradient. The outlet of the column was connected to a triple quadrupole mass spectrometer with electrospray interface. Ions were detected in the positive multiple reaction monitoring mode. This method was validated over a linear range from 20.0 to 10,000 ng/mL for erlotinib, gefitinib, imatinib, lapatinib, nilotinib and sorafenib, and from 5.00 to 2500 ng/mL for dasatinib and sunitinib. Results from the validation study demonstrated good intra‐ and inter‐assay accuracy (<13.1%) and precision (10.0%) for all analytes. This method was successfully applied for routine therapeutic drug monitoring purposes in patients treated with the investigated TKIs. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
An analytical method using high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry has been developed and validated for simultaneous measurement of four tyrosine kinase inhibitors used for renal cell carcinoma and their metabolites in human plasma. Despite their similar structures, it is difficult to measure plasma levels of these compounds simultaneously using optimal MS parameters for each compound because a quantitative range exceeding 50,000‐fold is required. To overcome this problem, we used a linear range shift technique using in‐source collision‐induced dissociation. Linearity ranges of sorafenib, sorafenib N‐oxide, sunitinib, N‐desethyl sunitinib, axitinib and pazopanib were 100–10,000, 10–1,000, 1–100, 1–100, 1–100 and 500–50,000 ng/mL, respectively. The intra‐ and inter‐day precision and accuracy were high, and coefficients of variation and relative error were <10.3% and within ±11.8%, respectively. The matrix effects of all analytes ranged from 87.7 to 114.8%. Extraction recoveries and overall recoveries showed small extraction loss (<15.0%) for all analytes. Moreover, all cancer patient samples used in this study were successfully quantified and fell within the linear range of measurement. Therefore, this novel analytical system using in‐source collision‐induced dissociation has sufficient performance to measure plasma concentrations of these four tyrosine kinase inhibitors and their metabolites for therapeutic drug monitoring.  相似文献   

11.
To support therapeutic drug monitoring of patients with cancer, a fast and accurate method for simultaneous quantification of the registered anticancer drugs afatinib, axitinib, ceritinib, crizotinib, dabrafenib, enzalutamide, regorafenib and trametinib in human plasma using liquid chromatography tandem mass spectrometry was developed and validated. Human plasma samples were collected from treated patients and stored at −20°C. Analytes and internal standards (stable isotopically labeled analytes) were extracted with acetonitrile. An equal amount of 10 mm NH4CO3 was added to the supernatant to yield the final extract. A 2 μL aliquot of this extract was injected onto a C18‐column, gradient elution was applied and triple‐quadrupole mass spectrometry in positive‐ion mode was used for detection. All results were within the acceptance criteria of the latest US Food and Drug Administration guidance and European Medicines Agency guidelines on method validation, except for the carry‐over of ceritinib and crizotinib. These were corrected for by the injection order of samples. Additional stability tests were carried out for axitinib and dabrafenib in relation to their reported photostability. In conclusion, the described method to simultaneously quantify the eight selected anticancer drugs in human plasma was successfully validated and applied for therapeutic drug monitoring in cancer patients treated with these drugs.  相似文献   

12.
Hu W  Xu Y  Liu F  Liu A  Guo Q 《Biomedical chromatography : BMC》2008,22(10):1108-1114
A sensitive, specific and rapid high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was described and validated for the quantification of ambroxol in human plasma using enalaprilat as the internal standard (IS). Chromatographic separation was performed on a Lichrospher CN column with a mobile phase of methanol and water (containing 0.1% formic acid) (70:30, v/v). The total run time was 5.0 min for each sample. The analytes was detected by mass spectrometry with electrospray ionization source in positive selected reaction monitoring mode. The precursor-fragment ion reaction for ambroxol was m/z 378.9 --> 263.8, and for IS was m/z 349.0 --> 205.9. The linearity was established over the concentration range of 1.56-400.00 ng/mL. The inter-day and the intra-day precisions were all within 10%. A simple protein precipitation with methanol was adopted for sample preparation. The extraction recoveries of ambroxol and IS were higher than 90.80%. The validated method was successfully applied in pharmacokinetic study after oral administration of 90 mg ambroxol to 24 healthy volunteers.  相似文献   

13.
Baclofen is used to manage alcohol dependence. This study describes a simple method using liquid chromatography coupled to high‐resolution mass spectrometry (LC‐HR‐MS) developed in plasma samples. This method was optimized to allow quantification of baclofen and determination of metabolic ratio of its metabolites, an oxidative deaminated metabolite of baclofen (M1) and its glucuronide form (M2). The LC‐HR‐MS method on Exactive® apparatus is a newly developed method with all the advantages of high resolution in full‐scan mode for the quantification of baclofen and detection of its metabolites in plasma. The present assay provides a protein precipitation method starting with 100 μL plasma giving a wide polynomial dynamic range (R 2 > 0.999) between 10 and 2000 ng/mL and a lower limit of quantitation of 3 ng/mL for baclofen. Intra‐ and inter‐day precisions were <8.1% and accuracies were between 91.2 and 103.3% for baclofen. No matrix effect was observed. The assay was successfully applied to 36 patients following baclofen administration. Plasma concentrations of baclofen were determined between 12.2 and 1399.9 ng/mL and metabolic ratios were estimated between 0.4 and 81.8% for M1 metabolite and on the order of 0.3% for M2 in two samples.  相似文献   

14.
A rapid and sensitive ultraperformance liquid chromatography tandem mass spectrometry assay was developed for the simultaneous analysis of oxcarbazepine and its main metabolite in human plasma. The assay involves a simple solid‐phase extraction procedure of 0.3 mL of human plasma and analysis was performed on a triple‐quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionization. Separation was achieved on an Acquity UPLC™ BEH C18 column (50 × 2.1 mm, i.d., 1.7 µm) with isocratic elution at a flow‐rate of 0.25 mL/min and imipramine was used as the internal standard. The standard calibration curve was linear over the range 9.580–5070.205 ng/mL for oxcarbazepine (OXC) and 19.444–10290.800 ng/mL for 10,11‐dihydro‐10‐hydroxycarbamazepine (MHD), expressed by the linear correlation coefficient r2, which was better than 0.995 for OXC and MHD. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.0%. The recoveries were 81.0, 89.6 and 66.6% for OXC, MHD and imipramine, respectively. The total run time was 1.5 min only for each sample, which makes it possible to analyze more than 350 samples per day. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of amlodipine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase C(18) column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 409/238 for amlodipine and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 50-10,000 pg/mL for amlodipine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of amlodipine and the IS from spiked plasma samples were 74.7 +/- 4.6 and 72.1 +/- 2.0%, respectively. A run time of 1.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. The observed maximum plasma concentration (Cmax) of amlodipine (2.5 mg oral dose) was 1425 pg/mL, time to observed maximum plasma concentration (Tmax) was 8.1 h and elimination half-life (T(1/2)) was 50.1 h.  相似文献   

16.
Oral prochlorperazine (PCZ), an antiemetic, undergoes extensive first-pass metabolism. The study developed a simultaneous analytical method for PCZ and its major metabolites, prochlorperazine sulfoxide (PCZSO), N-demethylprochlorperazine (NDPCZ) and 7-hydroxyprochlorperazine (PCZOH), in human plasma using an isocratic liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Deproteinized plasma specimens were separated using a 3 μm particle size octadecylsilyl column, and the run time was 10 min. The calibration curves were linear over the concentration ranges of 0.01-40 μg/L for PCZ, NDPCZ and PCZOH, and 0.05-80 μg/L for PCZSO. The intra- and inter-assay precisions and accuracies were within 7.0 and 99-104% and within 9.0 and 99-105%, respectively. The lower limits of quantification in human plasma were 10 ng/L for PCZ, NDPCZ and PCZOH, and 50 ng/L for PCZSO. The validated method was applied to the determination of plasma samples in 37 cancer patients receiving PCZ. Large interindividual variations were observed in plasma concentrations of PCZ, PCZSO, NDPCZ and PCZOH (relative standard deviation, 89.4, 88.7, 86.4 and 78.2%, respectively). In conclusion, this simultaneous LC-MS/MS method with acceptable analytical performance can be helpful for evaluating the pharmacokinetics of PCZ, including the determination of its metabolites in cancer patients and in clinical research.  相似文献   

17.
The field‐assisted paper spray (FAPS) – mass spectrometric method has been employed to quantify the imatinib (IMT) plasma levels in treated patients. The quantitative measurements have been performed on the collisionally generated fragment at m/z 394 of the protonated molecules of IMT and deuterated IMT (d3‐IMT), used as internal standard. The FAPS‐tandem mass spectrometry (MS/MS) method exhibits some limitations, because of the high number of operative parameters that need to be carefully controlled. For this aim, papers of different geometry, thickness, and porosity were tested. To obtain a more focalized and intense electrical field, a stainless steel needle was mounted axially and placed at 4 kV voltage. The variability observed in the measurements was ascribed either to the inter‐individual variability (e.g. the concomitant presence of other compounds such as proteins, lipids, drugs and/or salts in the plasma of different patients) or to the uncontrollable variables in the instrumental set‐up (e.g. sample deposition, changes in paper spray conditions). Furthermore, the manual sample deposition and solvent dripping strongly affects the measure reproducibility. Despite this, it is interesting to observe that, once applied in blind on 24 real plasma samples, FAPS‐MS/MS led to results analogous to those obtained by the well‐consolidated liquid chromatography‐MS/MS, even if the mean coefficient of variation % (CV%) values of 20.4% and 2.6% were observed for the two methods, respectively. In conclusion, despite CV values are relatively high, it is worth noting that the FAPS‐MS/MS method is much more straightforward, rapid and economical than the liquid chromatography‐MS/MS one, and it appears therefore very promising for applications where a high precision is not always a required task, as e.g. in some cases of therapeutic drug monitoring. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

18.
A sensitive and simple liquid chromatography-tandem mass spectrometry method for the determination of midazolam and 1'-hydroxymidazolam in human plasma has been developed and validated with a dynamic range of 0.1-250 ng/mL. The analysis was based on semi-automated liquid-liquid extraction followed by evaporation of the extraction solvent, reconstitution and chromatography on a reversed-phase C(18) column. The mobile phase consists of 5 mm ammonium acetate and methanol and runs in gradient at a flow rate of 0.25 mL/min with column temperature of approximately 20 degrees C. The entire column effluent was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 4.3 min per injection, with retention times for midazolam, 1'-hydroxymidazolaml and the internal standard, triazolam, of 2.5, 2.3 and 2.1 min, respectively. The intra-day and inter-day precision (RSD %) and accuracy (bias %) of the quality control samples were <15.0% and within +/-13%, respectively. The current method has been applied to a clinical drug-drug interaction study in human.  相似文献   

19.
A sensitive, rapid and specific method for the simultaneous quantification of oxysophocarpine (OSC) and its active metabolite sophocarpine (SC) in rat plasma was developed and validated, using a liquid-liquid extraction procedure followed by liquid chromatography/electrospray ionization mass spectrometric (LC/ESI-MS) analysis. The separation was performed on a Zorbax Extend-C(18) column (2.1 mm i.d. x 50 mm, 5 microm) with a C(18) guard column using methanol-water containing 5 mm ammonium acetate (15:85, v/v) as mobile phase. Analysis was performed in selected ion monitoring (SIM) mode with an electrospray ionization (ESI) interface. [M + H](+) at m/z 263 for OSC, [M + H](+) at m/z 247 for SC and [M + H](+) at m/z 249 for matrine (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration ranges 10-1000 ng/mL for OSC and 5-500 ng/mL for SC. The intra- and inter-day precisions (coefficient of variation) were within 7% for both analytes. Their accuracy (relative error) ranged from -6.4 to 1.5%. The limits of detection for OSC and SC were 3 and 1.5 ng/mL, respectively. The limits of quantitation for OSC and SC were 10 and 5 ng/mL, respectively. Recoveries of both analytes were greater than 85% at the low, medium and high concentrations. Both analytes were stable during all sample storage, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of OSC to rats with a dose of 15 mg/kg.  相似文献   

20.
A simple and sensitive liquid chromatography tandem mass spectrometry method has been developed for the quantification of ambrisentan (AMB) in human plasma using midazolam (MID) as an internal standard (IS). Chromatographic separation was performed using a Beta Basic‐8 (50 × 4.6 mm, 5 µm) column with an isocratic mobile phase. AMB and MID were detected with proton adducts at m/z 379.09 → 303.12 and 326.15 → 291.14 in multiple reaction monitoring‐positive mode, respectively. A solid‐phase extraction method was used for extraction of the analyte and IS from the plasma samples. The method was shown to be reproducible and reliable with within‐run precision <11%, between‐run precision <14% and linear concentration range from 10.0 to 2000.2 ng/mL, with a correlation coefficient (r2) of >0.995. The method was successfully applied to a pharmacokinetic study of oral administration of AMB (10 mg) in 24 healthy Indian male human volunteers under fasting conditions. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号