首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel UPLC‐DAD method was developed and validated for the simultaneous determination of baicalin (baicalein‐7‐glucuronide, BG), oroxylin A‐7‐O‐glucuronide (OAG) and wogonoside (WG) in rat plasma using rutin as the internal standard. Plasma samples were precipitated using acetonitrile containing 0.1% formic acid. Separation was performed on an Agilent Eclipse Plus C18 column (2.1 × 50 mm, 1.8 µm) using gradient acetonitrile and 0.2% formic acid water solution as mobile phase. The flow‐rate was set at 0.4 mL/min and the eluate was detected at 275 nm. The method was linear over the ranges of 0.075–17.50, 0.050–12.60 and 0.056–14.10 µg/mL for BG, OAG and WG, respectively. The intra‐ and inter‐day precisions were respectively <4.8% and 6.4%. All of the limits of detection of three analytes in rat plasma were 0.01 µg/mL, whereas the limits of quantification were, respectively, 0.035, 0.025 and, 0.025 µg/mL. This assay has been successfully applied to pharmacokinetics of BG, OAG and WG in rats after oral administration of Yinhuang granule (YHG) and comparative pharmacokinetics of BG in rats following oral administration of the pure BG, Radix Scutellariae (RS) or YHG. We speculate that some co‐existing ingredients in RS or YHG may increase the absorption and elimination of BG in rat. This work may be helpful for the quality control of Yinhuang granule. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
A sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS‐MS) method for quantification of a newly developed anticancer agent NPD‐103 has been established. An aliquot of human plasma sample (200 µL) was spiked with 13C‐labeled paclitaxel (internal standard) and extracted with 1.3 mL of tert‐butyl methyl ether. NPD‐103 was quantitated on a C18 column with methanol–0.1% formic acid (75:25, v/v) as mobile phase using UPLC‐MS‐MS operating in positive electrospray ionization mode with a total run time of 3.0 min. For NPD‐103 at the concentrations of 1.0, 5.0 and 10.0 µg/mL in human plasma, the absolute extraction recoveries were 95.58, 102.43 and 97.77%, respectively. The linear quantification range of the method was 0.1–20.0 µg/mL in human plasma with linear correlation coefficients greater than 0.999. The intra‐ and inter‐day accuracy for NPD‐103 at 1.0, 5.0 and 10.0 µg/mL levels in human plasma fell into the ranges of 95.29–100.00% and 91.04–94.21%, and the intra‐ and inter‐day precisions were in the ranges of 8.96–11.79% and 7.25–10.63%, respectively. This assay is applied to determination of half‐life of NPD‐103 in human plasma. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
A novel and automated, stability-indicating, reversed phase ultra performance liquid chromatography (UPLC) method was developed and validated for the quantitative determination of erdosteine, its known impurities and two novel degradation products in a new pharmaceutical dosage form (effervescent tablets). The chromatographic separations were performed on a Waters Acquity UPLC HSS T3, 1.8 µm (2.1 mm?×?150 mm, I.D.) stainless steel column. The mobile phase consisted of 0.1% TFA in water and methanol under gradient elution conditions, at a flow rate of 0.29 mL/min, for the assay and impurities analysis. UV detection was set at a wavelength of 238 nm. Erdosteine raw material, placebo and effervescent tablets were subjected to forced degradation. The new degradation products (labeled OX1 and OX2) were found after oxidative treatment and characterized by ultra performance liquid chromatography mass spectrometry. The validation parameters such as linearity, limit of detection (LOD) and quantification (LOQ), accuracy, precision, specificity and robustness were highly satisfactory for all analyzed compounds. LOD (0.020 and 0.011–0.385 µg/mL for erdosteine and impurities, respectively) and LOQ values show the high sensibility of the method. Specificity of the method was confirmed by testing the matrix components. The validated method demonstrated to be suitable for routine quality control purposes and for routine stability studies of erdosteine in effervescent formulations.  相似文献   

4.
An ultra performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the determination of nifedipine in human plasma using nifedipine‐d6 as the internal standard (IS). The plasma samples were prepared by solid‐phase extraction on Phenomenex Strata‐X cartridges employing 200 μL human plasma. Chromatography was carried out on Waters Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 µm particle size) analytical column under isocratic conditions using a mobile phase consisting of 4.0 mm ammonium acetate‐acetonitrile (15:85, v/v). The precursor → product ion transitions for nifedipine (m/z 347.2 → 315.2) and IS (m/z 353.1 → 318.1) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring and positive‐ion mode. The method was validated over a wide dynamic concentration range of 0.050–150 ng/mL. Matrix effect was assessed by post‐column analyte infusion and the mean extraction recovery was 95.6% across four quality control levels. The method is rugged and rapid with a total run time of 1.2 min and was applied to a bioequivalence study of 20 mg nifedipine tablet formulation in 30 healthy Indian subjects under fasting condition. Assay reproducibility was confirmed by reanalysis of 116 incurred samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
Thymoquinone (THQ) is known for its neuroprotective and anti‐convulsant properties in preclinical studies. We herewith describe a simple, rapid, selective, sensitive and stability‐indicating UPLC method for the estimation of THQ and its application to biopharmaceutical studies such as in vitro release from nanoparticulate system and in vivo pharmacokinetic study. The method employed gradient elution using a Waters Acquity HSS‐T3 C18 (100 × 2.1 mm, 1.8 µm) UPLC column. The mobile phase consisted of water and acetonitrile, pumped at a flow rate of 0.5 mL/min. The injection volume was 5 µL and THQ was monitored at 294 nm wavelength with a total run time of 6 min. In solution as well as in plasma, the method was found to be linear (r ≥ 0.998), precise (CV ≤ 2.45%) and accurate (recovery ≥ 84.8%) in the selected concentration range of 0.1–0.8 µg/mL. Forced degradation studies revealed that THQ undergoes degradation under acidic, basic, oxidation and UV light stress conditions. However, the developed UPLC method could effectively resolve degradation product peaks from THQ. Further, no interference was found at the retention time of THQ from any plasma components, indicating selectivity of the developed method. For solutions, the limits of detection and quantitation of the method were found to be 0.001 and 0.0033 µg/mL, respectively; while in plasma they were 0.006 and 0.02 µg/mL, respectively. The validated method was successfully applied to quantify THQ in dissolution medium as well as oral in vivo pharmacokinetic study of THQ suspension and THQ‐ solid lipid nanoparticle (THQ‐SLN) formulation. A 2‐fold increase in the relative bioavailability was observed with the THQ‐SLN compared with THQ. The results indicate that the SLN significantly increased plasma concentrations and retention within the systemic circulation. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
A simple, sensitive, and accurate stability‐indicating analytical method has been developed and validated using ultra high performance liquid chromatography. The developed method is used to evaluate the related substances of eplerenone (EP). The degradation behavior of EP under stress conditions was determined, and the major degradants were identified by ultra high performance liquid chromatography with tandem mass spectrometry. The chromatographic conditions were optimized using an impurity‐spiked solution, and the samples, generated from forced degradation studies. The resolution of EP, its potential impurities, and its degradation products was performed on a Waters UPLC BEH C18 column (50 × 2.1 mm, 1.7 μm) by linear gradient elution using a mobile phase consisting of 10 mmol/L ammonium acetate adjusted to pH 4.5, methanol and acetonitrile. A photo‐diode array detector set at 245 nm was used for detection. The flow rate was set at 0.3 mL/min. The procedure had good specificity, linearity (0.02–3.14 μg/mL), recovery (96.1–103.9%), limit of detection (0.01–0.02 μg/mL), limit of quantitation (0.03–0.05 μg/mL), and robustness. The correction factors of the process‐related substances were calculated.  相似文献   

7.
An efficient HPLC method was developed and validated for the simultaneous determination of ergosterol and 22,23‐dihydroergosterol in Flammulina velutipes sterol‐loaded microemulsions (FVSMs). The different chromatographic conditions for in vitro and in vivo determinations were investigated, with the application examined by tissue distribution. Chromatographic separation was achieved on an Inertsil ODS‐SP (250 × 4.6 mm, 5 µm) analytical column using a mobile phase of 98% methanol (in vitro), and 93% methanol for stomach samples and 96% methanol for other samples (in vivo) at 1.0 mL/min. The sterol content was detected at 282 nm. The established in vitro linearity ranges for ergosterol and 22,23‐dihydroergosterol were 0.58–72.77 µg/mL (r1 = 0.9999) and 0.59–73.25 µg/mL (r2 = 0.9999), respectively, with the biological (in vivo) samples following the same trend. The accuracy of the method was >99% (in vitro) and between 93%–108% (in vivo). The LOQ was 2.15 µg/L for ergosterol and 2.41 µg/L for 22,23‐dihydroergosterol in the in vitro studies. Also, the precisions met the acceptance criterion. These results indicate that the established HPLC method was specific, linear, accurate, precise and sensitive for the separation and simultaneous determination of ergosterol and 22,23‐dihydroergosterol. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
An environmentally friendly ionic liquids dispersive liquid–liquid microextraction (IL‐DLLME) method coupled with high‐performance liquid chromatography (HPLC) for the determination of antihypertensive drugs irbesartan and valsartan in human urine samples was developed. The HPLC separations were accomplished in less than 10 min using a reversed‐phase C18 column (250 × 4.60 mm i.d., 5 µm) with a mobile phase containing 0.3 % formic acid solution and methanol (v/v, 3:7; flow rate, 1.0 mL/min). UV absorption responses at 236 nm were linear over a wide concentration range from 50 µg/mL to the detection limits of 3.3 µg/L for valsartan and 1.5 µg/L for irbesartan. The effective parameters on IL‐DLLME, such as ionic liquid types and their amounts, disperser solvent types and their volume, pH of the sample and extraction time were studied and optimized. The developed IL‐DLLME‐HPLC was successfully applied for evaluation of the urine irbesartan and valsartan profile following oral capsules administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
A qualitative and quantitative analytical method was developed for the simultaneous determination of Δ9‐tetrahydrocannabinol (THC), 11‐hydroxy‐Δ9‐tetrahydrocannabinol (11‐OH‐THC) and l1‐nor‐9‐carboxy‐Δ9‐tetrahydrocannabinol (THC‐COOH) in whole blood. The samples were prepared by solid‐phase extraction followed by ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) analysis using positive ion electrospray ionization and multiple reaction monitoring. The chromatographic separation was performed with an Acquity UPLC® HSS T3 (50 × 2.1 mm i.d., 1.8 µm) reversed‐phase column using a methanol/2 mM ammonium formate (formic acid 0.1%) gradient in a total run time of 9.5 min. MS/MS detection was achieved with two precursor‐product ion transitions per substance. The method was fully validated, including selectivity and capacity of identification, according to the identification criteria (two transitions per substance, signal‐to‐noise ratio, relative retention time and ion ratio) without the presence of interferences, limit of detection (0.2 µg/L for THC and 0.5 µg/L for 11‐OH‐THC and THC‐COOH), limit of quantitation (0.5 µg/L for all cannabinoids), recovery (53–115%), carryover, matrix effect (34‐43%), linearity (0.5‐100 µg/L), intra‐assay precision (CV < 10% for the relative peak area ratios and <0.1% for the relative retention time), inter‐assay accuracy (mean relative error <10%) and precision (CV <11%). The method has already been successfully used in proficiency tests and subsequently applied to authentic samples in routine forensic analysis. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
A novel, specific and sensitive ultraperformance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was developed for the simultaneous determination of quinapril and its active metabolite quinaprilat in human plasma. The method involves a simple, one‐step extraction procedure coupled with an Acquity UPLC? BEH C18 column (100 × 2.1 mm, i.d., 1.7 µm) with isocratic elution at a flow‐rate of 0.2 mL/min and lisinopril as the internal standard. Detection was performed on a triple‐quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionization. Using 250 µL plasma, the methods were validated over the concentration range 5.010–500.374 ng/mL for quinapril and 10.012–1000 ng/mL for quinaprilat, with a lower limit of quantification of 5.010 ng/mL for quinapril and 10.012 ng/mL for quinaprilat. The intra‐ and inter‐day precision and accuracy were within 10.0%. The recovery was 85.8, 62.6 and 61.3% for quinapril, quinaprilat and lisinopril, respectively. Total run time was 3.0 min only. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

11.
A rapid, simple, sensitive and selective ultraperformance liquid chromatography–tandem spectrometry (UPLC‐MS/MS) method for the determination of nalbuphine and its prodrug sebacoly dinalbuphine ester (SDE) was developed and validated in human plasma. The sample pretreatment involves basification and iterative liquid–liquid extraction with ethyl‐ether–dichloromethane (7:3, v/v) solution, followed by LC separation and positive electrospray ionization (ESI) API‐3000 mass spectrometry detection. The chromatography was on a Waters Acquity UPLC BEH HILIC column (2.1 × 100 mm, 1.7 µm). The mobile phase was composed of acetonitrile and water (83:17, v/v) that contained 0.2% formic acid and 4 mm ammonium formate at a flow rate of 0.25 mL/min. Ethylmorphine and naloxine were selected as the SDE and nalbuphine internal standard (IS), respectively. The calibration curve for both was linear over the range from 0.05 to 20 ng/mL, with correlation coefficients ≥0.995. The lower limit of quantification was set at 0.05 ng/mL. The intra‐ and inter‐day precision values for nalbuphine and SDE were acceptable as per FDA guidelines. The method was applied successfully to determine nalbuphine concentration in human plasma samples obtained from four Taiwanese volunteers receiving intramuscularly administration of sebacoyl dinalbuphine ester. The method is sensitive, selective and directly applicable to human pharmacokinetic studies involving nalbuphine. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
An ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the simultaneous determination of carvedilol and its pharmacologically active metabolite 4′‐hydroxyphenyl carvedilol in human plasma using their deuterated internal standards (IS). Samples were prepared by solid‐phase extraction using 100 μL human plasma. Chromatographic separation of analytes was achieved on UPLC C18 (50 × 2.1 mm, 1.7 µm) column using acetonitrile‐4.0 mm ammonium formate, pH 3.0 adjusted with 0.1% formic acid (78:22, v/v) as the mobile phase. The multiple reaction monitoring transitions for both the analytes and IS were monitored in the positive electrospray ionization mode. The method was validated over a concentration range of 0.05–50 ng/mL for carvedilol and 0.01‐10 ng/mL for 4′‐hydroxyphenyl carvedilol. Intra‐ and inter‐batch precision (% CV) and accuracy for the analytes varied from 0.74 to 3.88 and 96.4 to 103.3% respectively. Matrix effect was assessed by post‐column analyte infusion and by calculation of precision values (coefficient of variation) in the measurement of the slope of calibration curves from eight plasma batches. The assay recovery was within 94–99% for both the analytes and IS. The method was successfully applied to support a bioequivalence study of 12.5 mg carvedilol tablets in 34 healthy subjects. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
A rapid, selective and sensitive method using UPLC‐MS/MS was first developed and validated for quantitative analysis of koumine in rat plasma. A one‐step protein precipitation with methanol was employed as a sample preparation technique. Plasma samples were separated on an Acquity UPLC BEH C18 column (50 × 2.1 mm, i.d. 1.7 µm) with a gradient mobile phase consisting of methanol with 0.1% (v/v) formic acid and water containing 0.1% (v/v) formic acid at a flow rate of 0.3 mL/min. Detection and quantification were performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via positive eletrospray ionization. Good linearity (r > 0.9997) was achieved using weighted (1/x2) least squares linear regression over a concentration range of 0.025–15 µg/mL with a lower limit of quantification of 0.025 µg/mL for koumine. The intra‐ and inter‐ precisions (relative standard deviation) of the assay at all three quality control samples were 5.6–14.1% with an accuracy (relative error) of 5.0–14.0%, which meets the requirements of the US Food and Drug Administration guidance. This developed method was successfully applied to an in vivo pharmacokinetic study in rats after a single intravenous dose of 20 mg/kg koumine. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
In the present investigation, a simple and isocratic HPLC‐UV method was developed and validated for determination of rilpivirine (RPV) from dosage forms (tablets and nanoparticles) and biological matrices like HeLa cell lysates. The separation and analysis of RPV was carried out under isocratic conditions using (a) a Gemini reversed‐phase C18 column (5 µm; 4.6 × 150 mm) maintained at 35°C, (b) a mobile phase consisting of a mixture of acetonitrile and 25 m m potassium dihydrogen phosphate (in the ratio 50:50 v/v) at a flow rate of 0.6 mL/min and (c) atazanavir as an internal standard. The total run time was 17 min and the analysis of RPV and internal standard was carried out at 290 nm. The method was found to be linear (r2 value > 0.998), specific, accurate and precise over the concentration range of 0.025–2 µg/mL. The lower limit of quantification was 0.025 µg/mL, the limit of detection was 0.008 µg/mL and the recovery of RPV was >90%. The stability of the RPV analytical method was confirmed at various conditions such as room temperature (24 h), ?20°C (7 days), three freeze?thaw cycles and storage in an autosampler (4°C for 48 h). The method was successfully applied for the determination of RPV from conventional dosage forms like tablets, from polymeric nanoparticles and from biological matrices like HeLa cell lysates. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
Norisoboldine (NIB) is one of the main bioactive isoquinoline alkaloids in Linderae Radix. A rapid, selective and sensitive method using UPLC‐ESI/MS was first developed for simultaneous determination of NIB and norisoboldine‐9‐Oα‐glucuronide (NIB‐Glu), its major metabolite in rat plasma. A one‐step protein precipitation with methanol was employed as sample preparation technique. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column (50 × 2.1 mm, i.d. 1.7 µm) with a gradient mobile phase consisting of acetonitrile and water containing 0.1% formic acid. Detection and quantification were performed using a quadrupole mass spectrometer by selective ion reaction‐monitoring mode. Good linearity was achieved using weighted (1/x2) least squares linear regression over the concentration ranges 0.01–2 µg/mL for NIB and 0.025–25 µg/mL for NIB‐Glu. The lower limit of quantification of NIB and NIB‐Glu was 0.01 and 0.025 µg/mL, respectively. The intra‐ and inter‐day precisions (relative standard deviations) of the assay at all three quality control levels were 4.6–14.1% for NIB, and 5.0–12.2% for NIB‐Glu. The accuracies (relative error) were −13.5–8.1% for NIB and −12.8–7.6% for NIB‐Glu, respectively. This developed method was successfully applied to an in vivo pharmacokinetic study in rats after a single intravenous dose of 10 mg/kg NIB. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
In this study, a stability‐indicating reversed‐phase liquid chromatographic electrospray mass spectrometric method was developed and validated for the determination of process‐related impurities and forced degradants of Efavirenz in bulk drugs. Efavirenz was subjected to acid, alkaline hydrolysis, H2O2 oxidation, photolysis, and thermal stress. Significant degradation was observed during alkaline hydrolysis, and the degradants were isolated on a mass‐based purification system and characterized by high‐resolution mass spectrometry, positive electrospray ionization tandem mass spectrometry, and 1H and 13C NMR spectroscopy. Accurate mass measurement and NMR spectroscopy revealed the possible structure of process‐related impurities and degradant under stress conditions. The acceptable separation was accomplished on Waters bondapak C18 column (250 mm × 4.6 mm; 5 μm), using 5 mM ammonium acetate and acetonitrile as a mobile phase in a gradient elution mode at a flow rate of 1.0 mL/min. The eluents were monitored by diode array detector at 247 nm and quantitation limits were obtained in the range of 0.1–2.5 μg/mL for Efavirenz, degradants, and process‐related impurities. The liquid chromatography method was validated with respect to accuracy, precision, linearity, robustness, and limits of detection and quantification as per International Conference on Harmonization guidelines.  相似文献   

17.
A simple and sensitive method based on the combination of derivatization and high‐performance liquid chromatography with ultraviolet and fluorimetric detection was developed for the simultaneous determination of octreotide and gabexate mesylate metabolite in human pancreatic juice samples. Parameters of the derivatization procedure affecting extraction efficiency were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.1–15 µg/mL for octreotide and 0.20‐15 µg/mL for gabexate mesylate metabolite. Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The limits of detection were 0.025 and 0.05, respectively, for octreotide and gabexate mesylate metabolite. This paper reports the validation of a quantitative high performance liquid chromatography–photodiode array–fluorescence (HPLC‐PDA‐FL) method for the simultaneous analysis of octreotide and gabexate mesylate metabolite in pancreatic juice by protein precipitation using zinc sulfate–methanol–acetonitrile containing the derivatizing reagent, 4‐fluoro‐7‐nitro‐[2,1,3]‐benzoxadiazole (NBD‐F). Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The method was validated over the concentration ranges 0.1–15 and 0.2–15 µg/mL for octreotide and gabexate mesylate metabolite, respectively, in human pancreatic juice. Biphalin and methyl‐p‐hydroxybenzoate were used as the internal standards. This method was successfully utilized to support clinical studies in humans. The results from assay validations show that the method is selective, sensitive and robust. The limit of quantification of the method was 0.1 µg/mL for octreotide and 0.2 µg/mL for gabexate mesylate metabolite, and matrix matched standard curves showed a good linearity up to 15 µg/mL. In the entire analytical range the intra‐ and inter‐day precision (RSD%) values were respectively ≤5.9% and ≤3.1% for octreotide and ≤2.0% and ≤3.9% for gabexate mesylate metabolite. For both analytes the intra‐ and inter‐day accuracy (bias) values ranged respectively from ?6.8 to –2.5% and from ?4.6 to ?5.7%. This method utilizes derivatization with NBD‐F and provides adequate sensitivity for both drugs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A direct large volume injection high‐performance liquid chromatography (HPLC) method with homemade restricted‐access media (RAM) pre‐column and combined with a column‐switching valve was established and developed for determination rifampicin (RIP) in rat plasma. The rat plasma samples (100 μL) were injected directly onto pre‐column, where RIP was retained and pre‐concentrated, while proteins were washed to waste using a methanol–water (5:95) as the mobile phase at a flow rate of 1 mL/min. Then, by rotation of the switching valve at 5 min, the RIP were eluted from the pre‐column and transferred to an Luna C18 analytical column by the chromatographic mobile phase consisting of methanol–acetonitrile–10 mm ammonium format (60:5:35) at a flow rate of 1 mL/min. The total analytical run time was 15 min with UV detection wavelength at 254 nm. Carbamazepine was used as the internal standard. Excellent linear correlation (r = 0.9993) was obtained in the range of 0.25–8 µg/mL for rat plasma. The intra‐day and inter‐day precisions of RIP were all <5.0%. The recoveries were in the range of from 99.98–113.66% for plasma. This on‐line RAM‐HPLC method was successfully applied to the pharmacokinetic study of RIP in rat plasma. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
A simple and reproducible bioanalytical method for the determination of flecainide in human plasma was developed and validated using an ultra‐performance liquid chromatography with tandem mass spectrometry (UPLC‐MS/MS) to obtain higher sensitivity than the current available methods. After simple protein precipitation, flecainide and a stable isotope‐labeled internal standard (IS) were chromatographed on an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with isocratic elution of mobile phase consisting of 45% methanol containing 0.1% formic acid at a flow rate 0.25 mL/min. Detection was performed in positive electrospray ionization by monitoring the selected ion transitions at m/z 415.4/301.1 for flecainide and m/z 419.4/305.1 for the IS. The method was validated according to current bioanalytical method validation guidelines. The calibration standard curve was linear from 2.5 to 1000 ng/mL using 0.1 mL of plasma. No significant interferences were detected in blank human plasma. Accuracy and precision in the intra‐ and inter‐batch reproducibility study were within acceptance criteria. Neither hemolysis effects nor matrix effects were observed. The UPLC‐MS/MS method developed was successfully applied to determine plasma flecainide concentrations to support clinical studies and incurred sample reanalysis also ensured the reproducibility of the method. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
In this paper, we present a validated UPLC‐MS/MS assay for determination of ramipril and ramiprilat from human plasma samples. The assay is capable of isolating phase II metabolites (acylglucornides) of ramipril from in vivo study samples which is otherwise not possible using conventional HPLC conditions. Both analytes were extracted from human plasma using solid‐phase extraction technique. Chromatographic separation of analytes and their respective internal standards was carried out using an Acquity UPLC BEH C18 (2.1 × 100 mm), 1.7 µm column followed by mass spectrometric detection using an Waters Quattro Premier XE. The method was validated over the range 0.35–70.0 ng/mL for ramipril and 1.0–40.0 ng/mL for ramiprilat. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏