共查询到20条相似文献,搜索用时 15 毫秒
1.
Quantification of taraxasterol in rat plasma by LC/MS/MS: application to a pharmacokinetic study 下载免费PDF全文
Taraxasterol, a pentacyclic triterpene from Taraxacum officinale, is one of the main active constituents of the herb. This study developed and validated a highly selective and sensitive liquid chromatography/tandem mass spectrometry for the determination of taraxasterol in rat plasma over the range of 9.0–5000 ng/mL. Chromatographic separation was achieved on a C18 (4.6 × 50 mm, 5.0 µm) column with methanol–isopropanol–water–formic acid (80:10:10:0.1, v/v/v/v) as mobile phase with an isocratic elution. The flow rate was 0.7 mL/min. After adding cucurbitacin IIa as an internal standard (IS), liquid–liquid extraction was used for sample preparation using ethyl acetate. The atmospheric pressure chemical ionization source was applied and operated in positive ion mode. Selected reaction monitoring mode was used for the quantification of transition ions m/z 409.4 → 137.1 for taraxasterol and m/z 503.4 → 113.1 for IS. The mean recoveries of taraxasterol in rat plasma ranged from 85.3 to 87.2%. The matrix effects for taraxasterol were between 98.5 and 104.0%. Intra‐ and inter‐day precision were both <11.8%, and the accuracy of the method ranged from ?7.0 to 12.9%. The method was successfully applied to a pharmacokinetic study of taraxasterol after oral administration of 7.75, 15.5 and 31.0 mg/kg in rats. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
2.
Quanfei Zou Yuan Gu Rong Lu Tiejun Zhang Guang‐Rong Zhao Changxiao Liu Duanyun Si 《Biomedical chromatography : BMC》2013,27(9):1123-1128
In this study, a simple and sensitive LC/MS/MS method was developed and validated for the determination of arctigenin in rat plasma. The MS detection was performed using multiple reaction monitoring at the transitions of m/z 373.2 → 137.3 for arctigenin and m/z 187.1 → 131.0 for psoralen (internal standard) with a Turbo IonSpray electrospray in positive mode. The calibration curves fitted a good linear relationship over the concentration range of 0.2–500 ng/mL. It was found that arctigenin is not stable enough at both room temperature and ?80 °C unless mixed with methanol before storage. The validated LC/MS/MS method was successfully applied for the pharmacokinetic study of arctigenin in rats. After intravenous injection of 0.3 mg/kg arctigenin injection to rats, the maximum concentration, half‐life and area under the concentration–time curve were 323 ± 65.2 ng/mL, 0.830 ± 0.166 and 81.0 ± 22.1 h ng/mL, respectively. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
3.
Complanatoside A is a flavonol glycoside isolated from Astragalus complanatus, and currently it is used as a quality control index for A. complanatus in the 2010 edition of the Chinese Pharmacopoeia. For the first time, a simple and sensitive LC‐MS/MS method was developed for the determination of complanatoside A in rat plasma over the range of 2.3–575 ng/mL. Complanatoside A was extracted from plasma by a protein precipitation procedure, separated by LC and detected by MS/MS in positive electrospray ionization mode. The method was validated for selectivity, carryover, sensitivity, linearity, extraction recovery, matrix effect, accuracy, precision and stability studies. The lower limit of quantification was established at 2.3 ng/mL. Intra‐ and inter‐day precisions (LLOQ, low‐QC, med‐QC and high‐QC) were <7.9%, and accuracies were between 94.0 and 105.1%. Matrix effect was acceptable (97.9–103.0%) and extraction recovery was reproducible (88.5–94.4%). Complanatoside A was stable in the investigated conditions. The method was applied to the pharmacokinetics of complanatoside A in rats. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
4.
Development and validation of an LC‐MS/MS method for the determination of bullatine A in rat plasma: application to a pharmacokinetic study 下载免费PDF全文
Shi‐Yong Teng Si‐Xi Zhang Kai Niu Li‐Jie Zhai Shi‐Ji Wang 《Biomedical chromatography : BMC》2015,29(12):1798-1804
Bullatine A is a diterpenoid alkaloid of Xue‐Shang‐Yi‐Zhi‐Hao (Aconitum brachypodum), which is widely used in traditional Chinese medicine for the treatment of rheumatism and pain. The plasma levels of bullatine A were measured by a rapid and sensitive LC‐MS/MS method. Samples were prepared using acetonitrile precipitation and the separation of bullatine A was achieved on a Capcell Pak MG‐C18 column by isocratic elution using acetonitrile (phase A) and 0.1% formic acid (phase B, pH 4.0; A:B, 30:70, v/v) as the mobile phase at a flow rate of 0.5 mL/min. Detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple‐reaction monitoring of the transitions at m/z 344.2 → 105.2 for bullatine A and m/z 256.2 → 167.1 for the internal standard. The linearity was found to be within the concentration range of 1.32–440 ng/mL with a lower limit of quantification of 1.32 ng/mL. Only 1.3 min was needed for an each analytical run. This method was successfully applied in the determination of the active component bullatine A in rat plasma after intramuscular administration of A. brachypodum injection. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
5.
Quantitative determination of euphol in rat plasma by LC‐MS/MS and its application to a pharmacokinetic study 下载免费PDF全文
Xu Xie Yongning Li Dongna Gao Yu Zhang Yanbo Ren 《Biomedical chromatography : BMC》2014,28(9):1229-1234
Euphol is a potential pharmacologically active ingredient isolated from Euphorbia kansui. A simple, rapid, and sensitive method to determine euphol in rat plasma was developed based on liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) for the first time. The analyte and internal standard (IS), oleanic acid, were extracted from plasma with methanol and chromatographied on a C18 short column eluted with a mobile phase of methanol–water–formic acid (95:5:0.1, v/v/v). Detection was performed by positive ion atmospheric pressure chemical ionization in selective reaction monitoring mode. This method monitored the transitions m/z 409.0 → 109.2 and m/z 439.4 → 203.2 for euphol and IS, respectively. The assay was linear over the concentration range 27–9000 ng/mL, with a limit of quantitation of 27 ng/mL. The accuracy was between –7.04 and 4.11%, and the precision was <10.83%. This LC‐MS/MS method was successfully applied to investigate the pharmacokinetic study of euphol in rats after intravenous (6 mg/kg) and oral (48 mg/kg) administration. Results showed that the absolute bioavailability of euphol was approximately 46.01%. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
6.
Xiaoli Wu Chuwen Li Qingguo Li Zhen Qin Yuyang Yi Jiannan Chen Xiaoping Lai Ziren Su 《Biomedical chromatography : BMC》2013,27(9):1092-1099
Pogostone is an important constituent of Pogostemon cablin (Blanco) Benth., and possesses various known bioactivities. A rapid, simple and sensitive liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed for the analysis of pogostone in rat plasma using chrysophanol as internal standard (IS). The analytes were extracted with methanol and separated using a reversed‐phase YMC‐UltraHT Pro C18 column. Elution was achieved with a mobile phase consisting of methanol–water (75:25, v/v) for 5 min at a flow rate of 400 μL/min. The precursor/product transitions (m/z) under MS/MS detection with negative electrospray ionization (ESI) were 223.0 → 139.0 and 253.1 → 224.9 for pogostone and IS, respectively. The calibration curve was linear over the concentration range 0.05–160 µg/mL (r = 0.9996). The intra‐ and inter‐day accuracy and precision were within ±10%. The validated method was successfully applied to the preclinical pharmacokinetic investigation of pogostone in rats after intravenous (5, 10 and 20 mg/kg) and oral administration (5, 10 and 20 mg/kg). Finally, the oral absolute bioavailability of pogostone in rats was calculated to be 70.39, 78.18 and 83.99% for 5, 10 and 20 mg/kg, respectively. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
7.
Fei Yun An Kang Jinjun Shan Xiaoli Zhao Xiaolin Bi Liuqing Di 《Biomedical chromatography : BMC》2013,27(5):676-680
Osthole, a major component isolated from the fruit of Cnidium monnieri (L.) Cusson, has been widely used in traditional Chinese medicine. We developed and validated a rapid and sensitive LC‐MS/MS method for the quantification of osthole in rat plasma. Sample preparation involved simple liquid–liquid extraction by ethyl acetate after addition of imperatorin as internal standard (IS). The analyte was separated using a C18 column with the mobile phase of methanol–0.1% formic acid (80:20, v/v) at a flow rate of 0.4 mL/min. The elutes were detected under positive electrospray ionization in multiple reaction monitoring mode. The method was sensitive with 0.5 ng/mL as the lower limit of detection. Good linearity was obtained over the range of 1.0–500.0 ng/mL. The intra and inter‐batch accuracy for osthole in rat plasma samples ranged from 99.5 to 108.1% and the variation was <8.9%. The stability, extraction efficiency and matrix effect were also acceptable. This method was successfully applied to the pharmacokinetic study of osthole in rat after intravenous and oral administration. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
8.
《Biomedical chromatography : BMC》2017,31(3)
Hinokiflavone has drawn a lot of attention for its multiple biological activities. In this study, a sensitive and selective method for determination of hinokiflavone in rat plasma was developed for the first time, using liquid chromatography–tandem mass spectrometry (LC–MS/MS). Amentoflavone was used as an internal standard. Separation was achieved on a Hypersil Gold C18 column with isocratic elution using methanol–water (65:35, v /v) as mobile phase at a flow rate of 0.3 mL/min. A triple quadrupole mass spectrometer operating in the negative electrospray mode with selected reaction monitoring was used to detect the transitions of m/z 537 → 284 for hinokiflavone and m/z 537 → 375 for IS. The LOQ was 0.9 ng/mL with a linear range of 0.9–1000 ng/mL. The intra‐ and inter‐day accuracy (RE%) ranged from −3.75 to 6.91% and from −9.20 to 2.51% and the intra‐ and inter‐day precision (RSD) was between 0.32–14.11 and 2.85–10.04%. The validated assay was successfully applied to a pharmacokinetic study of hinokiflavone in rats. The half‐life of drug elimination at the terminal phase was 6.10 ± 1.86 h, and the area under the plasma concentration‐time curve from time zero to the time of last measurable concentration and to infinity values obtained were 2394.42 ± 466.86 and 2541.93 ± 529.85 h ng/mL, respectively. 相似文献
9.
Wang D Li F Li P Zhang J Liu L Xu P Zhou L Liu X 《Biomedical chromatography : BMC》2012,26(10):1282-1285
This study aimed to develop and validate a liquid chromatography tandem mass spectrometry method for measuring clematichinenoside AR in rat plasma. Clematichinenoside AR was extracted by solid‐phase extraction and chromatographed on an XTerra MS C8 column. Pulchinenoside B4 was used as the internal standard. Elution was achieved using an isocratic mobile phase of acetonitrile with 0.1% acetic acid (21:79, v/v) at a flow‐rate of 0.2 mL/min. The detection was performed by multiple reaction monitoring mode via a negative electrospray ionization interface. Standard curves were linear, ranging from 2.5 to 500 ng/mL. The intra‐ and inter‐day precision values were <14.0% and the accuracy was within ±13%. Extraction recovery ranged from 93.2 to 93.9%. This proposed method was successfully applied to a pharmacokinetic study on clematichinenoside AR in rats after oral administration. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
10.
An LC‐MS/MS method for determination of calceorioside B with cardiomyocyte protective activity in rat plasma and application to a pharmacokinetic study 下载免费PDF全文
A simple, sensitive and rapid liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the determination of calceorioside B (CLB) in rat plasma. Detection was performed on a Thermo Scientific Hypersil Gold chromatography column using isocratic elution with a mobile phase of methanol–5 m m ammonium acetate–formic acid (70:30:0.1, v/v/v). Mass spectrometry was performed in selection reaction monitoring mode using a positive electrospray ionization interface. Good linearity was found for CLB in plasma in the linear range of 1.00–500 ng/mL (r > 0.9960). The validated method was successfully applied to the pharmacokinetic study of CLB in rats. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
11.
A novel, sensitive and rapid ultra‐performance liquid chromatography–tandem mass spectrometric method for the quantification of chikusetsusaponin IVa (CHS‐IVa) in rat plasma was established and validated. Plasma samples were pre‐treated by precipitation of protein with acetonitrile and chromatographed on a Waters Symmetry C18 analytical column (4.6 × 50 mm, i.d., 3.5 μm) using a mobile phase consisting of methanol and water containing 0.05% formic acid (55:45, v/v) at a flow rate of 0.4 mL/min. The deprotonated molecular ions [M ? H]– were employed in electrospray negative ionization mode and selected reaction monitoring transitions were performed for detection. The calibration curves exhibited good linearity (r > 0.99) over the range of 0.5–1000 ng/mL for CHS‐IVa. The recoveries of CHS‐IVa were >92.5% and exhibited no severe matrix effect. This method was successfully applied in the pharmacokinetic study of CHS‐IVa in rats. For oral administration, the plasma concentrations of CHS‐IVa increased to a peak value at 0.35 ± 0.14 h, followed by a gradual decrease to the lower limit of quantitation in 24 h. For intravenous administration, the plasma concentrations of CHS‐IVa decreased quickly (t1/2, 1.59 ± 0.25 h). The absolute bioavailability of CHS‐IVa in rats was 8.63%. Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
12.
Development and validation of an LC‐MS/MS method for the determination of mesalazine in beagle dog plasma and its application to a pharmacokinetic study 下载免费PDF全文
A simple, specific and sensitive LC‐MS/MS method was developed and validated for the determination of mesalazine in beagle dog plasma. The plasma samples were prepared by protein precipitation, then the separation of the analyte was achieved on a Waters Spherisorb C6 column (150 × 4.6 mm, 5 µm) with a mobile phase consisting of 0.2% formic acid in water–methanol (20:80, v/v). The flow rate was set at 1.0 mL/min with a split ratio of 3:2. Mass spectrometric detection was achieved by a triple‐quadrupole mass spectrometer equipped with an electrospray source interface in positive ionization mode. Quantitation was performed using selected reaction monitoring of precursor–product ion transitions at m/z 154 → m/z 108 for mesalazine and m/z 285 → m/z 193 for diazepam (internal standard). The linear calibration curve of mesalazine was obtained over the concentration range 50–30,000 ng/mL. The matrix effect of mesalazine was within ±9.8%. The intra‐ and inter‐day precisions were <7.9% and the accuracy (relative error) was within ±3.5%. The validated method was successfully applied to investigate the pharmacokinetics of mesalazine in healthy beagle dogs after rectal administration of mesalazine suppository. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
13.
LC‐MS/MS method for the determination of agomelatine in human plasma and its application to a pharmacokinetic study 下载免费PDF全文
Xiaolin Wang Dan Zhang Man Liu Hongna Zhao Aihua Du Lingjie Meng Huichen Liu 《Biomedical chromatography : BMC》2014,28(2):218-222
A sensitive and selective LC‐MS/MS method for the determination of agomelatine in human plasma was developed and validated. After simple liquid–liquid extraction, the analytes were separated on a Zorbax SB‐C18 column (150 × 2.1 mm i.d., 5 µm) with an isocratic mobile phase consisting of 5 mm ammonium acetate solution (containing 0.1% formic acid) and methanol (30:70, v/v) at a flow‐rate of 0.3 mL/min. The MS acquisition was performed in multiple reaction monitoring mode with a positive electrospray ionization source. The mass transitions monitored were m/z 244.1 → 185.3 and m/z 285.2 → 193.2 for agomelatine and internal standard, respectively. The methods were validated for selectivity, carry‐over, matrix effects, calibration curves, accuracy and precision, extraction recoveries, dilution integrity and stability. The validated method was successfully applied to a pharmacokinetic study of agomelatine in Chinese volunteers following a single oral dose of 25 mg agomelatine tablet. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
14.
Kumar A Devaraj VC Giri KC Giri S Rajagopal S Mullangi R 《Biomedical chromatography : BMC》2012,26(12):1464-1471
A highly sensitive, rapid assay method has been developed and validated for the estimation of nobiletin in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves extraction of nobiletin and citalopram (internal standard, IS) from rat plasma with liquid–liquid extraction. Chromatographic separation wa s achieved using an isocratic mobile phase (0.2% formic acid–acetonitrile, 20:80, v/v) at a flow rate of 0.6 mL/min on an Atlantis dC18 column (maintained at 40 ± 1 °C) with a total run time of 2.0 min. The MS/MS ion transitions monitored were 403.2 → 373.0 for nobiletin and 325.2 → 109.0 for IS. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.05 ng/mL and the linearity range extended from 0.05 to 51.98 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.96–14.3 and 6.21–12.1, respectively. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
15.
Su Liang Xiaomei Bian Jing Ma Motolani Arogunjo Amit A. Deorukhkar Sunil Krishnan Huan Xie 《Biomedical chromatography : BMC》2013,27(1):58-66
γ‐Tocotrienol has attracted much attention owing to its multiple health benefits. This study developed and validated a simple, specific, sensitive and reliable LC/MS/MS method to analyze γ‐tocotrienol in rat plasma. Plasma samples (50 μL) were extracted with internal standard solution (25 ng/mL of itraconazole) in acetonitrile (200 μL) with an average recovery of 44.7% and an average matrix effect of ?2.9%. The separation of γ‐tocotrienol and internal standard from the plasma components was achieved with a Waters XTerra® MS C18 column with acetonitrile–water as mobile phase. Analysis was performed under positive ionization electrospray mass spectrometer via the multiple reaction monitoring. The standard curve was linear over a concentration range of 10–1000 ng/mL with correlation coefficient values >0.997. The method was validated with intra‐ and inter‐day accuracy (relative error) ranging from 1.79 to 9.17% and from 2.16 to 9.66%, respectively, and precision (coefficient of variation) ranged from 1.94 to 9.25% and from 2.37 to 10.08%, respectively. Short‐term stability, freeze–thaw stability and the processed sample stability tests were performed. This method was further applied to analyze γ‐tocotrienol plasma concentrations in rats at various time points after administration of a 2 mg/kg single intravenous dose, and a pharmacokinetic profile was successfully obtained. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
16.
A rapid and sensitive LC‐MS/MS method for the determination of Pulsatilla saponin D in rat plasma and its application in a rat pharmacokinetic and bioavailability study 下载免费PDF全文
Hui Ouyang Yicheng Guo Mingzhen He Jinlian Zhang Xiaofang Huang Xin Zhou Hongliang Jiang Yulin Feng Shilin Yang 《Biomedical chromatography : BMC》2015,29(3):373-378
A simple, sensitive and specific liquid chromatography–tandem mass spectrometry method was developed and validated for the determination of Pulsatilla saponin D, a potential antitumor constituent isolated from Pulsatilla chinensis in rat plasma. Rat plasma samples were pretreated by protein precipitation with methanol. The method validation was performed in accordance with US Food and Drug Administration guidelines and the results met the acceptance criteria. The method was successfully applied to assess the pharmacokinetics and oral bioavailability of Pulsatilla saponin D in rats. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
17.
A sensitive and rapid liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for determination of bakkenolide D (BD), which was further applied to assess the pharmacokinetics of BD. In the LC‐MS/MS method, the multiple reaction monitoring mode was used and columbianadin was chosen as internal standard. The method was validated over the range of 1–800 ng/mL with a determination coefficient >0.999. The lower limit of quantification was 1 ng/mL in plasma. The intra‐ and inter‐day accuracies for BD were 91–113 and 100–104%, respectively, and the inter‐day precision was <15%. After a single oral dose of 10 mg/kg of BD, the mean peak plasma concentration of BD was 10.1 ± 9.8 ng/mL at 2 h. The area under the plasma concentration–time curve (AUC0–24 h) was 72.1 ± 8.59 h ng/mL, and the elimination half‐life (T1/2) was 11.8 ± 1.9 h. In case of intravenous administration of BD at a dosage of 1 mg/kg, the AUC0–24 h was 281 ± 98.4 h?ng/mL, and the T1/2 was 8.79 ± 0.63 h. Based on these results, the oral bioavailability of BD in rats at 10 mg/kg is 2.57%. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
18.
Junpei Fan Jie Sun Suhui Zhang Yue Hu Li Wei Chunhua Wu Xiuli Chang Liming Tang Zhijun Zhou 《Biomedical chromatography : BMC》2016,30(8):1190-1194
A precise, high‐throughput and sensitive ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the determination of fluorochloridone (FLC) in rat plasma. The extraction of analytes from plasma samples was carried out by protein precipitation procedure using acetonitrile prior to UPLC‐MS/MS analysis. Verapamil was proved as a proper internal standard (IS) among many candidates. The chromatographic separation based on UPLC was well optimized. Multiple reaction monitoring in positive electrospray ionization was used with the optimized MS transitions at: m/z 312.0 → 292.0 for FLC and m/z 456.4 → 165.2 for IS. This method was well validated with good linear response (r2 > 0.998) observed over the investigated range of 3–3000 ng/mL and with satisfactory stability. This method was also characterized with adequate intra‐ and inter‐day precision and accuracy (within 12%) in the quality control samples, and with high selectivity and less matrix effect observed. Total running time was only 1.5 min. This method has been successfully applied to a pilot FLC pharmacokinetic study after oral administration. Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
19.
Sengupta P Sarkar AK Bhaumik U Chatterjee B Roy B Chakraborty US Pal TK 《Biomedical chromatography : BMC》2010,24(12):1342-1349
A simple, high‐throughput and specific high‐performance liquid chromatography tandem mass spectrometry method has been developed and validated according to the FDA guidelines for simultaneous quantification of olmesartan and pioglitazone in rat plasma. The bioanalytical method consists of liquid–liquid extraction and quantitation by triple quadrupole mass spectrometry using electrospray ionization technique, operating in multiple reaction monitoring and positive ion modes. The compounds were eluted isocratically on a C18 column with a mobile phase consisting of a mixture of methanol and water (containing 0.5% formic acid) in a ratio of 9:1. The response to olmesartan and pioglitazone was linear over the range 0.01–10 µg/mL. The validation results demonstrated that the method had satisfactory precision and accuracy across the calibration range. Intra‐ and inter‐day precisions ranged from 0.66 to 3.32 and from 0.94 to 2.93% (%CV), respectively. The accuracy determined at three quality control levels was within 91.27–107.28%. There was no evidence of instability of the analytes in rat plasma following the stability studies. The method proved highly reproducible and sensitive and was successfully applied in a pharmacokinetic study after single dose oral administration of olmesartan and pioglitazone to the rat. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
20.
Rower JE Bushman LR Hammond KP Kadam RS Aquilante CL 《Biomedical chromatography : BMC》2010,24(12):1300-1308
Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug–drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA‐anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra‐assay precision between 1.6 and 10.7%, and inter‐assay precision ranging from 4.4 to 7.8%. The assay also showed good accuracy, with intra‐assay concentrations within 85.6–108.7% of the expected value, and inter‐assay concentrations within 89.4–104.0% of the expected value. The linear concentration range was between 0.5 and 50 µg/mL with a lower limit of quantitation of 0.5 µg/mL when 125 µL of plasma were extracted. This LC/MS method yielded a quick, simple and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献