首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A silica-based monolithic stationary phase with mixed-mode of reversed phase (RP) and weak anion-exchange (WAX) for capillary electrochromatography (CEC) has been prepared. The mixed-mode monolithic silica column was prepared using the sol–gel technique and followed by a post-modification with hexadecyltrimethoxysilane (HDTMS) and aminopropyltrimethoxysilane (APTMS). The amino groups on the surface of the stationary phase were used to generate a substantial anodic EOF as well as to provide electrostatic interaction sites for charged compounds at low pH. A cathodic EOF was observed at pH above 7.3 due to the full ionization of residual silanol groups and the suppression in the ionization of amino groups. A variety of analytes were used to evaluate the electrochromatographic characterization and column performance. The monolithic stationary phase exhibited RP chromatographic behavior toward neutral solutes. The model anionic solutes were separated by the mixed-mode mechanism, which comprised RP interaction, WAX, and electrophoresis. Symmetrical peaks can be obtained for basic solutes because positively charged amino groups can effectively minimize the adsorption of positively charged analytes to the stationary phase.  相似文献   

2.
伊瑞霉素键合手性毛细管整体柱的制备与对映体分离   总被引:1,自引:0,他引:1  
雷雯  张凌怡  万莉  朱亚仙  覃飒飒  张维冰 《色谱》2010,28(10):977-983
以具有22个不同种类手性中心的新型大环抗生素伊瑞霉素为手性选择器,基于环氧基团高反应活性的特征,将伊瑞霉素用一步法键合到甲基丙烯酸酯整体柱表面制备伊瑞霉素键合手性毛细管整体柱。通过对制备条件进行优化,证实该制备方法可在较宽的pH范围(6.0~9.0)内进行,方法简单易行,反应条件温和。应用制备的手性毛细管整体柱在毛细管电色谱模式下,对5种手性氨基酸对映体和手性药物罗格列酮对映体进行拆分,均得到了基线分离,说明伊瑞霉素手性固定相具有较强的手性拆分能力。在优化的色谱条件下,6种对映体的分析时间均小于4 min,分析速度快。通过对有机调节剂、缓冲液pH值和缓冲盐浓度等分离条件进行系统考察,初步探讨了该手性毛细管整体柱对不同溶质的手性识别机理。  相似文献   

3.
A single-step approach has been used to prepare a monolithic electrochromatographic column by sol-gel processing of an organofunctional silicon alkoxide precursor that contains a propyl-N,N,N-trimethylammonium group. We have found that the time of adding the porogen, poly(ethylene glycol), during the sol-gel reaction affected the separation performance. Since the surface charge of this material is switchable in sign upon manipulation of solution pH, the direction and magnitude of the electroosmotic flow (EOF) can be controlled by adjusting the pH of the running electrolyte. By controlling the direction of the EOF from cathode to anode, inorganic anions can be separated in a short time. Because of the quaternary ammonium functional group, the resulting material is anion exchangeable. Interestingly, the anion-exchange selectivity of inorganic anions on this column changes with solution pH or applied voltage. The column shows excellent run to run reproducibility (R.S.D. < 0.4%), good day to day reproducibility (R.S.D. < 4%), and reasonable column to column reproducibility (R.S.D. < 9%).  相似文献   

4.
Various parameters have been evaluated to develop a process for optimization of column manufacture for packed capillary electrochromatography (CEC). Spherisorb ODS-1 was packed into 75 microm I.D. capillaries to establish a standard set of packing conditions to afford high-performance columns free of voids. Numerous silica-based packing materials including porous and non-porous reversed-phase and ion-exchange phases were employed to evaluate the applicability of the standard conditions. Success of column manufacture and performance demonstrate a relationship to the colligative properties of the packing materials under the applied conditions. Frequently encountered difficulties arising from inadequate column conditioning and void formation in the packed bed are identified and discussed.  相似文献   

5.
A monolithic silica based strong cation-exchange stationary phase was successfully prepared for capillary electrochromatography. The monolithic silica matrix from a sol-gel process was chemically modified by treatment with 3-mercaptopropyltrimethoxysilane followed by a chemical oxidation procedure to produce the desired function. The strong cation-exchange stationary phase was characterized by its substantial and stable electroosmotic flow (EOF), and it was observed that the EOF value of the prepared column remained almost unchanged at different buffer pH values and slowly decreased with increasing phosphate concentration in the mobile phase. The monolithic silica column with strong cation-exchange stationary phase has been successfully employed in the electrochromatographic separation of beta-blockers and alkaloids extracted from traditional Chinese medicines (TCMs). The column efficiencies for the tested beta-blockers varied from 210,000 to 340,000 plates/m. A peak compression effect was observed for atenolol with the mobile phase having a low phosphate concentration.  相似文献   

6.
7.
Trietazine was selectively separated from aqueous solution containing the competitor molecule cyanazine, which is similar in size and shape to the template molecule. Structural features of the molecularly imprinted column were figured out by SEM. The influence of the mobile‐phase composition, applied electrical field, and pH of the mobile phase on the recognition of trietazine by the imprinted monolithic polymer has been evaluated, and the imprint effect in the trietazine‐imprinted monolithic polymer was demonstrated by an imprinting factor. The optimized monolithic column resulted in separation of trietazine from a structurally related competitor molecule, cyanazine. In addition, fast separation was obtained within 6 min by applying higher electrical field, with the electrophoretic mobility of 2.97 × 10?8 m2V?1s?1 at pH 11.0.  相似文献   

8.
Yan L  Zhang Q  Zhang W  Feng Y  Zhang L  Li T  Zhang Y 《Electrophoresis》2005,26(15):2935-2941
A novel hybrid organic-inorganic silica-based monolithic column possessing phenyl ligands for reversed-phase (RP) capillary electrochromatography (CEC) is described. The monolithic stationary phase was prepared by in situ co-condensation of tetraethoxysilane (TEOS) with phenyltriethoxysilane (PTES) via a two-step catalytic sol-gel procedure to introduce phenyl groups distributed throughout the silica matrix for chromatographic interaction. The hydrolysis and condensation reactions of precursors were chemically controlled through pH variation by adding hydrochloric acid and dodecylamine, respectively. The structural property of the monolithic column can be easily tailored through adjusting the composition of starting sol solution. The effect of PTES/TEOS ratios on the morphology of the created stationary phases was investigated. A variety of neutral and basic analytes were used to evaluate the column performance. The CEC columns exhibited typical RP chromatographic retention mechanism for neutral compounds and had improved peak shape for basic solutes.  相似文献   

9.
Sakaki T  Kitagawa S  Tsuda T 《Electrophoresis》2000,21(15):3088-3092
The instrumentation for miniaturization of capillary electrochromatography was devised and an injection method for this apparatus was proposed. By using an ultra short capillary column (15 mm packed length, 36 mm total length, 75 microm inner diameter, packed with cation exchange supports), the separation of five biochemical compounds was performed within 1 min. The high separation efficiency of 9780 plates was achieved by using an ultrashort capillary column. The miniaturized instrumentation for capillary electrochromatography might be utilized as one of the possible methods in microfabricated analysis or in an alternative approach to it.  相似文献   

10.
黄桂华  陈思谨  林旭聪  谢增鸿 《色谱》2010,28(12):1173-1178
以2-羟基乙基甲基丙烯酸酯(HEMA)为单体,乙二醇二甲基丙烯酸酯(EDMA)为交联剂,制备了亲水分离模式的聚HEMA-co-EDMA新型毛细管电色谱(CEC)整体柱。考察了整体柱的结构特征及其CEC性能,研究了极性物质的保留行为,并对其可能的保留机理进行了探讨。所制备的整体柱稳定性好,固定相表面带有极性羟基功能团,不仅能提供亲水相互作用位点,且能吸附流动相中的阴离子产生阳极电渗流(EOF)。在流动相中乙腈含量较高(>62%,体积分数)的条件下,整体柱表现出典型的亲水作用,实现了对核苷、碱基和苯胺类带有碱性的强极性化合物的高效分离,并成功分离了苯酚类、苯甲酸类等中性或酸性的极性化合物。  相似文献   

11.
A new type of capillary column for open-tubular electrochromatography   总被引:1,自引:0,他引:1  
Zhao Y  Zhao R  Shangguan D  Liu G 《Electrophoresis》2002,23(17):2990-2995
A new type of open-tubular C(18) ester-bonded electrochromatographic column was prepared with sol-gel technology, followed by an on-column octadecyl silylation reaction. Glycidoxypropyltrimethoxysilane, a widely used and important silane agent, was used as the sol-gel precursor to form a thin coating layer on the wall of the fused-silica capillary. The C(18) groups were introduced into the coating layer by on-column esterification reaction with stearic acid. The electrochromatography behavior of the column was evaluated in terms of the separation of peptides. A high efficiency of 4.8x10(5) plates/m was achieved for a basic pentapeptide using the C(18 )ester-bonded column. In comparison with bare capillaries and glycidoxypropyltrimethoxysilane sol-gel-coated capillaries, the C(18) ester-bonded column showed the best separation of a mixture of seven pentapeptides under identical conditions of buffer, pH, and applied voltage.  相似文献   

12.
Hybrid silica monolithic stationary phase functionalized with octyl groups was synthesized by a two-step acid/base-catalyzed hydrolysis/co-condensation of tetraethoxysilane (TEOS) and n-octyltriethoxysilane (C(8)-TEOS). The influences of determining factors in the sol-gel process such as the monomer ratio and water content on the monolith formation were systematically investigated. An increase in the TEOS/C(8)-TEOS ratio in the polymerization mixture shifted the pore size distribution towards smaller pore diameter with larger pore volume. The optimal TEOS/C(8)-TEOS volume ratio was found to be 90/50, under which condition the median pore diameter of the monolith was around 1.0 microm with pore volume of 3.25 cm(3)/g. The chromatographic characteristics of the monolithic column prepared with the optimized fabrication condition were studied. Some aromatic compounds including alkylbenzenes, polycyclic aromatic hydrocarbons (PAHs) and phenols were successfully separated on the octyl-functionalized silica monolithic column with high column efficiency up to 180,000 plates/m.  相似文献   

13.
亲水作用毛细管电色谱是当前微分离技术的研究热点之一,其固定相的研究受到了广泛的关注。本文介绍了亲水作用毛细管电色谱开管柱、填充柱和整体柱的研究进展,重点对近年来发展的亲水作用电色谱整体柱的制备技术进行了系统阐述。引用文献68篇。  相似文献   

14.
Ye F  Xie Z  Wu X  Lin X  Chen G 《Journal of chromatography. A》2006,1117(2):170-175
A novel stationary phase phenylaminopropyl silica (PhA-silica) monolith was successfully prepared for pressure assisted capillary electrochromatography (pCEC). The monolithic silica matrix from a sol-gel process was chemically modified by using [3-(phenylamino)propyl]trimethoxysilane as surface modification reagent to produce the phenylaminoporpyl function. The secondary amino groups on the surface of the monolithic stationary phase contributed to the generation of anodic electroosmotic flow (EOF) under acidic conditions. The phenyl group together with the spacer (-(CH(2))(3)-) in PhA-silica provides sufficient hydrophobic properties. To evaluate the column performance, effects of buffer pH and mobile phase composition on the mobile phase linear velocity and the retention factors of alkylbenzenes, phenols and anilines were investigated in pCEC mode. The monolithic stationary phases exhibit typical reversed-phase (RP) electrochromatographic behavior toward neutral solutes. Hydrophobic as well as electrophoretic migration process within the monoliths was observed for the separation of basic solutes such as anilines without peak tailing.  相似文献   

15.
In capillary electrochromatography (CEC) the flow of the mobile phase is generated by electrosmotic means in high electric field. This work compares band spreading measured experimentally in several packed capillaries with electrosmotic flow (EOF) and viscous flow under otherwise identical conditions. The data were fitted to the simplified van Deemter equation for the theoretical plate height, H = A + B/u + Cu, in order to evaluate parameters A and C in each mode of flow in the different columns. The ratio of these two parameters obtained with the same column in microscale HPLC (mu-HPLC) and CEC was used to quantify the attenuation of their contribution to band spreading upon changing from viscous flow (in mu-HPLC) to electrosmotic flow (in CEC). The capillary columns used in this study were packed with stationary phases of different pore sizes as well as retentive properties and measurements were carried out under different mobile phase conditions to examine the effects of the retention factor and buffer concentration. In the CEC mode, the value of both column parameters A and C was invariably by a factor of two to four lower than in the mu-HPLC mode. This effect may be attributed to the peculiarities of the EOF flow profile in the interstitial space and to the generation of intraparticle EOF inside the porous particles of the column packing. Thus, band spreading due to flow maldistribution and mass transfer resistances is significantly lower when the mobile phase flow is driven by voltage as in CEC, rather than by pressure as in mu-HPLC.  相似文献   

16.
Polymethacrylate-based monolith with weak cation exchange functionalities was prepared in capillary column (i.d. 100 μm, o.d. 375 μm) by in situ polymerization of butyl methacrylate, ethylene dimethacrylate and N-methacryloyl-L-glutamic acid in presence of porogens. The porogen mixture included N,N-dimethyl formamide and phosphate buffer. The preparation procedure of stationary phase contained the synthesis of monomer, silanization of capillary inner wall and in situ polymerization. The use of amino acid based monomer for the monolith synthesis is one of the originalities of this novel approach. N-methacryloyl-L-glutamic acid has two carboxyl functionalities. The separation of the solutes were performed at different acetonitrile/phosphate buffer and acetonitrile/sodium hydroxide contents. The applied voltage for the alkyl benzenes was changed between +5 and +30 kV. CEC separations of alkyl benzenes, acidic, basic, phenolic and some polycylic aromatic compounds were succesfully performed under capillary-electrochromatography mode with cathodic electroosmotic flow.  相似文献   

17.
A novel and convenient protocol for the preparation of an open-tubular column coated with chitosan-silica hybrid using chitosan and silane-coupling agent (γ-glycidoxy-propyltrimethoxysilane) was developed for CEC, in which, chitosan was covalently bonded to the inner wall of a fused-silica capillary using γ-glycidoxy-propyltrimethoxysilane as a cross-linking agent. The stationary phase was hydrophilic due to the chitosan-silica hybrid with abundant amine and hydroxyl functional groups. The chromatographic characteristics of the column were evaluated by the separation of some organic acids and inorganic anions. The column showed good selectivity for nucleotides, aromatic acids, and inorganic anions. The mechanism for the separation of these compounds was primarily based on the hydrophilic and electrostatic interactions combined with the electrophoretic mechanism. The CEC method on the column for the separation of these compounds was compared with CE method in a bare capillary.  相似文献   

18.
讨论了分子印迹毛细管电色谱整体柱的制备.联二蔡酚作为印迹分子在热引发条件下聚合,其中甲基丙烯酸为功能单体,二甲基丙烯酸乙二醇酯为交联剂,甲苯和异辛烷为致孔剂.考察了聚合参数对整体柱通透性及手性分离的影响.联二萘酚对映体在印迹整体柱上得到了基线分离,Rs值可达1.8.  相似文献   

19.
Problems encountered in capillary electrochromatography, i.e. non-reproducible column manufacture, bubble formation during usage, short column lifetimes and limited choice of packing particles are addressed by the development of fritless or single-frit, internally tapered, segmented and dead-volume free coupled capillary columns. The Van Deemter plots measured demonstrate the performance of these high-quality capillaries which are suitable for capillary electrochromatography as well as for capillary high-performance liquid chromatographic applications.  相似文献   

20.
Tian Y  Li H  Zeng Z 《Electrophoresis》2006,27(17):3381-3390
A novel open-tubular CEC (OT-CEC) column was prepared by immobilized 5,11,17,23-tetra-tert-butyl-25,27-diethoxy-26,28-dihydroxy-calix[4]arene (Calix[4]) on fused-silica capillary column with sol-gel technology. Calix[4] was initially reacted with gamma-glycidoxypropyltrimethoxysilane (KH-560) to form a new sol-gel precursor (calix[4]-KH-560), and then mixed with another precursor, namely tetraethoxysilane (TEOS). After hydrolysis and condensation, a sol-gel matrix was obtained, in which calix[4] was incorporated. Successful calix[4]-modified sol-gel coating was suggested by infrared (IR) spectra and greatly decreased EOF. In comparison with OT columns prepared by the sol-gel method with TEOS and KH-560 only, the calix[4]-modified sol-gel column showed greatly improved separation of isomeric toluidines, nitrophenols, picolines and neurotransmitters with structural similarity. Migration time and theoretical plate number reproducibility were satisfactory with RSDs less than 1 and 6% each for within column runs and not more than 3 and 7% each for column-to-column measurements, using toluidine and nitrophenol isomers as test solutes on this column. High separation efficiencies (96,000-300,000 plates/m) for basic toluidine isomers were obtained. This column was also successfully employed to combine extraction procedure for the determination of dopamine (DA) and norepinephrine (NE) in Portulaca oleracea L. The recoveries of DA and NE were 93.3 and 94.2%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号