首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sheathless electrospray at nL/min flow rates combined with Fourier-transform mass spectrometry has made possible high resolving power (\gr 50,000) mass spectra of subattomole samples of \gr 8 kDa proteins separated by capillary electrophoresis (Valaskovic, G. A.; Kelleher, N. L.; McLafferty, F. W. Science, 1996, 273, 1199-1202). However, for this new method the mechanical stability of the thin (35 to 100 nm) gold film electrodes has limited tip lifetime to 15 to 30 min. A technique for SiOx coating of the gold is described that provides a steady ion current (± 10 pA) for 1 to 2 h, even with arcs or interruptions of the electrospray voltage.  相似文献   

2.
When electrospray ionisation mass spectrometry (ESI-MS) is used on-line with capillary isoelectric focusing (CIEF), the presence of the carrier ampholytes creating the IEF pH gradient is not desirable. With the purpose of removing these ampholytes, we have developed a free-flow electrophoresis (FFE) device and coupled it to CIEF. The different parameters inherent to the resulting CIEF/FFE system were optimised using ultraviolet absorbance (UV) detection. The on-line coupling of this system with ESI-MS was successfully realised for three model proteins (myoglobin, carbonic anhydrase I and beta-lactoglobulin B).  相似文献   

3.
Capillary electrophoresis (CE) coupled to electrospray mass spectrometry via sheathless interfacing has been applied to the analysis of mammalian metallothionein (MT) extracts. In a rabbit-liver extract, four (MT-2C, MT-2A, MT-2D and MT-2E) out of six known MT sub-isoforms were unambiguously identified under three CE-resolved peaks. A fourth peak was found to contain MT-1A and/or MT-2B, whose molecular masses differ by only 1 Da. Traces of non-N-acetylated MT-2D and MT-2E were observed in a fifth, minor peak. In a rat-liver extract, both MT-1 and MT-2 were resolved and identified. Non-N-acetylated MT-2 was also identified in a resolved, minor peak. Minimum detectable amounts of MTs have been estimated to be approximately 0.6 fmol per sub-isoform.  相似文献   

4.
We describe the integration of a cyclo-olefin polymer based microchip with a sheathless capillary tip for electrospray ionization-mass spectrometry (ESI-MS). The microchip was fabricated by hot embossing and thermal bonding. Its design includes a side channel for adjusting the composition of the electrospray solution so that analytes in 100% water can be analyzed. The fused silica capillaries, used for sample introduction, and the electrospray tips for MS coupling were directly inserted into the microchannel before thermal bonding of the device. A microfabricated on-chip gold microelectrode was used to apply the electrospray voltage. Annealing the device after thermal bonding increased the pressure resistance of the microchip. The cross section of the microchannel was imaged by scanning electron microscopy to estimate the effects of the annealing step. The relationship between the applied electrospray voltages and MS signal was measured at different flow rates by coupling the device to an ion trap mass spectrometer. The performance of the microchip was evaluated by MS analysis of imipramine in ammonium acetate buffer solution by direct infusion. An alkylacrylate based monolith polymer bed for on-chip sample pretreatment and separation was polymerized in the microchannel and tested for ESI-MS applications.  相似文献   

5.
We describe a novel electrospray tip design for MS which is fabricated completely out of SU-8 photoepoxy. A three-layer SU-8 fabrication process provides fully enclosed channels and tips. The tip shape and alignment of all SU-8 layers is done lithographically and is therefore very accurate. Fabrication process enables easy integration of additional fluidic functions on the same chip. Separation channels can be made with exactly the same process. Fluidic inlets are made in SU-8 during the fabrication process and no drilling or other postprocessing is needed. Channels have been fabricated and tested in the size range of 10 microm x 10 microm-50 microm x 200 microm. Mass spectrometric performance of the tips has been demonstrated with both pressure-driven flow and EOF. SU-8 microtips have been shown to produce stable electrospray with EOF in a timescale of tens of minutes. With pressure driven flow stable spray is maintained for hours. Taylor cone was shown to be small in volume and well defined even with the largest channel cross section. The spray was also shown to be well directed with our tip design.  相似文献   

6.
This work describes the synchronized dual-polarity (DP) electrospray ionization (ESI) method and demonstrates the first DP ESI mass spectra obtained using two mass spectrometers. Stable double Taylor cones were produced by applying two counter electric voltages with opposite polarities to one electrosprayer. The development of double Taylor cones required higher extraction voltages than conventional ESI, but DP ESI worked effectively at liquid flow rate range three times wider than conventional ESI. Using pure methanol, the emission currents of the two cones were neutralized and no current was drawn from the sprayer. Synchronized DP mass spectra were obtained using electrospray calibrants dissolved in methanol solution of low water content. For bovine insulin with conventional electrospray solution, the gas-assisted electrospray delivered satisfactory sensitivity and stability for routine mass analyses.  相似文献   

7.
This work compares several different methods of site-specific analysis of glycoproteins using electrospray mass spectrometry. The glycoprotein, oLHalpha (ovine luteinizing hormone, alpha-subunit) was chosen as an appropriate example protein for these studies because of its biological relevance and extreme microheterogeneity. More than 20 unique glycoforms were detected for this glycoprotein at the Asn(56) site of oLHalpha. The carbohydrates present at this site affect receptor binding affinity, so understanding the great variety in the composition of these carbohydrates is important in studying ligand binding interactions. MS data was acquired on a quadrupole ion trap, a triple quadrupole, and a quadrupole time of flight mass spectrometer, and carbohydrate composition at the Asn(56) site of oLHalpha was determined using these instruments. Additionally, neutral loss and precursor ion scanning modes were also used to identify the glycoforms present, and these techniques were compared to the standard MS data. Of the three instruments compared in the study, the qTOF mass spectrometer achieved the lowest sample consumption, but all three instruments were useful in profiling the glycopeptide composition.  相似文献   

8.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   

9.
10.
Editorial Comment Last month we presented, as a Special Feature, a set of five articles that constituted a Commentary on the fundamentals and mechanism of electrospray ionization (ESI). These articles produced some lively discussion among the authors on the role of electrochemistry in ESI. Six authors participated in a detailed exchange of views on this topic, the final results of which constitute this month's Special Feature. We particularly hope that younger scientists will find value in this month's Special Feature, not only for the science that it teaches but also what it reveals about the processes by which scientific conclusions are drawn. To a degree, the contributions part the curtains on these processes and show science in action. We sincerely thank the contributors to this discussion. The give and take of intellectual debate is not always easy, and to a remarkable extent this set of authors has maintained good humor and friendships, even when disagreeing strongly on substance. Graham Cooks and Richard Caprioli Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

11.
Microfluidic electrocapture of peptides and proteins in an inert capillary with electric contacts via conductive membranes is useful for sample handling before mass spectrometry. The use of electrocapture has already been demonstrated for sample clean-up, pre-concentration, chemical modification and peptide separation, all without the need for supporting gels or chemical binding. This method allows multiple micro-reactions, extensive peptide separations and work with membrane proteins from detergent-solubilized samples. Until now, electrocapture has utilized MALDI mass spectrometry, but here we demonstrate that it can be interfaced with electrospray ionization and hence with on-line mass spectrometric analysis of peptides separated from protein digests. These applications combined with the present on-line approach show electrocapture to be a versatile technology with great potential.  相似文献   

12.
Rezenom YH  Dong J  Murray KK 《The Analyst》2008,133(2):226-232
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.  相似文献   

13.
Chip electrospray mass spectrometry for carbohydrate analysis   总被引:1,自引:0,他引:1  
Currently two types of chip systems are used in conjunction with MS: out-of-plane devices, where hundreds of nozzles, nanospray emitters are integrated onto a single silicon substrate from which electrospray is established perpendicular to the substrate, and planar microchips, embedding a microchannel at the end of which electrospray is generated in-plane, on the edge of the microchip. In the last two years, carbohydrate research greatly benefited from the introduction and implementation of the chip-based MS. In two laboratories the advantages of the chip electrospray in terms of ionization efficiency, sensitivity, reproducibility, quality of data in combination with high mass accuracy, and resolution of detection were systematically explored for several carbohydrate classes: O- and N-glycopeptides, oligosaccharides, gangliosides and glycoprotein-derived O- and N-glycans, and glycopeptides. The current state-of-the-art in interfacing the chip electrospray devices to high-performance MS for carbohydrate analysis, and the particular requirements for method optimization in both positive and negative ion modes are reviewed here. The recent applications of these miniaturized devices and their general potential for glycomic-based surveys are highlighted.  相似文献   

14.
Analytical and Chemical Sciences, Research Triangle Institute, Research Triangle Park, North Carolina, USA Negative ion electrospray (ES) operating on a single quadrupole mass spectrometer for the detection of low-molecular-weight molecules is discussed. The ES interface was operated at a positive cylindrical electrode potential to produce negative ions, and the results obtained were compared to the positive ion mode. As in the case of operation in the more common positive mode, negative ions with varying degrees of solvation and structurally relevant fragments can be obtained from a variety of solute species, including β-lactam antibiotics, aminoglycosides, aminocyclitols, tetracyclines, sulfonamides, nucleotides, peptides, and explosives. No fragmentation of parent species, except those from some labile explosives, was provided because low potential differences are applied between the capillary and the first skimmer, and electrical discharge is avoided in the gas phase. An increase in the capillary voltage resulted in collision-induced decomposition to produce structurally relevant fragment ions in both operation modes. An evaluation of representative chromatographic solvents indicated that 2-propanol added with oxygen in the ES bath gas is best suited to suppress electrical (corona) discharge phenomena in negative ion operation, whereas it aids in solution nebulization, desolvation, and transfer of ions in solution to the gas phase. For positive ion mode, no such precaution was necessary. Conditions that promote the formation of ions in solution usually improve ES response. Therefore, an increase in the solvent pH can increase the sensitivity in negative ion ES ionization. Negative ion ES offers the advantage of providing complementary structural information to help in the characterization of an unknown compound or to confirm a certain tentatively proposed structure. Nucleotides and explosives were best characterized in negative ion mode owing to the ease with which they form anions in solution, and they could be detected down to the l-pg /gML level.  相似文献   

15.
16.
Positive ion electrospray ionization mass spectra have been obtained of deoxyribonucleic acids (DNA) and ribonucleic acids (RNA), including transfer RNAs (77-mer, ~ 25 kDa). For several different solution conditions, the charge state distributions of DNA and RNA molecules were determined. It is postulated that the production of the multiply charged positive ions results from gas phase dissociation of complexes between nitrogen-containing bases and oligonucleotides.  相似文献   

17.
Oxysterols are oxygenated derivatives of cholesterol. They are intermediates in cholesterol excretion pathways and may also be regarded as transport forms of cholesterol. The introduction of additional hydroxyl groups to the cholesterol skeleton facilitates the flux of oxysterols across the blood brain barrier, and oxysterols have been implicated in mediating a number of cholesterol-induced metabolic effects. Oxysterols are difficult to analyze by atmospheric pressure ionization mass spectrometry on account of the absence of basic or acidic functional groups in their structures. In this communication, we report a method for the derivatization and analysis of oxysterols by electrospray mass spectrometry. Oxysterols with a 3beta-hydroxy-Delta5 structure were converted by cholesterol oxidase to 3-oxo-Delta4 steroids and then derivatized with the Girard P reagent to give Girard P hydrazones, which were subsequently analyzed by tandem mass spectrometry. The improvement in sensitivity for the analysis of 25-hydroxycholesterol upon oxidation and derivatization was over 1000.  相似文献   

18.
Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix.  相似文献   

19.
MVIIA and MVIIB omega-conotoxins were chosen to investigate the effect of experimental conditions on their conformations, because of the presence of three disulfide bridges in these toxins. There were no significant effects of ion-source temperature, cone voltage, pH and percentage of cosolvent. We show that charge state distributions (CSDs) observed in their electrospray mass spectra are not a true reflection of the behaviour in the bulk solution because of electrostatic effects during the ion-evaporation process in the ion source. As a result it is not possible to deduce from the observed CSDs that some basic amino acids are hidden in the core of the peptide structure. This is important in view of the complementary finding that nearly all labile hydrogens are rapidly exchanged in deuterated solvents. The mass spectrometry results can be reconciled with results of NMR experiments and molecular calculations from the literature.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号