首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Replica microchips for capillary array electrophoresis containing 10 separation channels (50 microm width, 50 microm depth and 100 microm pitch) and a network of sacrificial channels (100 microm width and 50 microm depth) were successfully fabricated on a poly(methyl methacrylate) (PMMA) substrate by injection molding. The strategy involved development of moving mask deep X-ray lithography to fabricate an array of channels with inclined channel sidewalls. A slight inclination of channel sidewalls, which can not be fabricated by conventional deep X-ray lithography, is highly required to ensure the release of replicated polymer chips from a mold. Moreover, the sealing of molded PMMA multichannel chips with a PMMA cover film was achieved by a novel bonding technique involving adhesive printing and a network of sacrificial channels. An adhesive printing process enables us to precisely control the thickness of an adhesive layer, and a network of sacrificial channels makes it possible to remove air bubbles and an excess adhesive, which are crucial to achieving perfect sealing of replica PMMA chips with well-defined channel and injection structures. A CCD camera equipped with an image intensifier was used to simultaneously monitor electrophoretic separations in ten micro-channels with laser-induced fluorescence detection. High-speed and high-throughput separations of a 100 bp DNA ladder and phi X174 Hae III DNA restriction fragments have been demonstrated using a 10-channel PMMA chip. The current work establishes the feasibility of mass production of PMMA multichannel chips at a cost-effective basis.  相似文献   

2.
微流控芯片技术因具有微量、快速、高效和高通量等特点,已成为分析化学领域中的研究热点之一.在微流控芯片中,最常见的可用作芯片的材料为玻璃、石英和各种塑料.玻璃和石英有很好的电渗性和光学性质,可采用标准的刻蚀工艺加工和用化学方法进行表面改性,但加工成本较高,封接难度较大.  相似文献   

3.
Tseng WL  Lin YW  Chen KC  Chang HT 《Electrophoresis》2002,23(15):2477-2484
Microfluidic devices with bubble cells have been fabricated on poly(methyl methacrylate) (PMMA) plates and have been employed for the analysis of DNA using polyethylene oxide (PEO) solutions. First, the separation channel was fabricated using a wire-imprinting method. Then, wires with greater sizes or a razor blade glued in a polycarbonate plate was used to fabricate bubble cells, with sizes of 190-650 microm. The improvements in resolution and sensitivity have been achieved for large DNA (> 603 base pair, bp) using such devices, which depend on the geometry of the bubble cell. The main contributor for optimal resolution is mainly due to DNA migration at lower electric field strengths inside the bubble cell. On the other hand, slight losses of resolution for small DNA fragments have been found mainly due to diffusion, supported by the loss of resolution when separating two small solutes. With a bubble cell of 75 microm (width) x 500 microm (depth), the sensitivity improvement up to 17-fold has been achieved for the 271 bp fragment in the separation of PhiX-174/HaeIII DNA restriction fragments. We have also found that a microfluidic device with a bubble cell of 360 microm x 360 microm is appropriate for DNA analysis. Such a device has been used for separating DNA ranging from 8 to 2176 bp and polymerase chain reaction (PCR) products amplified after 30 cycles, with rapidity and improvements in the sensitivity as well as resolution.  相似文献   

4.
Single photon burst techniques were used to detect double-stranded DNA molecules in poly(methylmethacrylate) (PM MA) and polycarbonate (PC) microfluidic devices. A confocal epi-illumination detection system was constructed to monitor the fluorescence signature from single DNA molecules that were multiply labeled with the mono-intercalating dye, TOPRO-5, which possessed an absorption maximum at 765 nm allowing excitation with a solid-state diode laser and fluorescence monitoring in the near-infrared (IR). Near-IR excitation minimized autofluorescence produced from the polymer substrate, which was found to be significantly greater when excitation was provided in the visible range (488 nm). A solution containing lambda-DNA (48.5 kbp) was electrokinetically transported through the microfluidic devices at different applied voltages and solution pH values to investigate the effects of polymer substrate on the transport rate and detection efficiency of single molecular events. By applying an autocorrelation analysis to the data, we were able to obtain the molecular transit time of the individual molecules as they passed through the 7 microm laser beam. It was observed that the applied voltage for both devices affected the transport rate. However, solution pH did not alter the transit time for PM MA-based devices since the electroosmotic flow of PMMA was independent of solution pH. In addition, efforts were directed toward optimizing the sampling efficiency (number of molecules passing through the probe volume) by using either hydrodynamically focused flows from a sheath generated by electrokinetic pumping from side channels or reducing the channel width of the microfluidic device. Due to the low electroosmotic flows generated by both PMMA and PC, tight focusing of the sample stream was not possible. However, in PMMA devices, flow gating was observed by applying field strengths > -120 V/cm to the sheath flow channels. By narrowing the microchannel width, the number of molecular events detected per unit time was found to be four times higher in channels with 10 microm widths compared to those of 50 microm, indicating improved sampling efficiency for the narrower channels without significantly deteriorating detection efficiency. Attempts were made to do single molecule sizing of lambda-DNA, M13 (7.2 kbp) and pUC19 (2.7 kbp) using photon burst detection. While the average number of photons for each DNA type were different, the standard deviations were large due to the Gaussian intensity profile of the excitation beam. To demonstrate the sensitivity of single molecule analysis in the near-IR using polymer microfluidic devices, the near-IR chromophore, NN382, wasanalyzed using ourconfocal imager. A detection efficiency of 94% for single NN382 molecules was observed in the PC devices.  相似文献   

5.
The development of rapid and simple wall coating strategies for high-efficiency electrophoretic separation of DNA is of crucial importance for the successful implementation of miniaturized polymeric DNA analysis systems. In this report, we characterize and compare different methods for the chemical modification of poly(methyl methacrylate) (PMMA) surfaces for the application of wall coating polymers. PMMA surfaces coated with 40 mol% diethylacrylamide and 60 mol% dimethylacrylamide are compared to the PMMA surfaces first oxidized and then coated with hydroxypropylmethyl-cellulose or poly(vinyl alcohol) (PVA). PMMA oxidation was accomplished with UV/ozone or an aqueous solution of HNO(3) to yield hydrogen-bond donors for the spontaneous adsorption of the coating polymers. Contact angle measurements of UV/ozone exposed PMMA surfaces indicate increase in hydrophilicity, and polymer coated surfaces show a strong dependence on the coating polymer and the oxidation method. Fast and repeatable electrophoretic separations of a 10-base and 20-base DNA ladder were performed in PMMA micro CE devices. All analyses were completed in less than 10 min, resulting in the number of theoretical plates as high as 583 000 in a 7.7 cm long separation channel. The duration of UV/ozone treatment was found to have a considerable impact on separation performance. The microchips irradiated with UV for 10 min and coated with PVA as well as the microchips treated with HNO(3) and coated with HPMC were found to have the best separation performance. These results demonstrate facile and robust methods for the surface modification of PMMA enabling low-cost single use devices for electrophoretic DNA separations.  相似文献   

6.
Li HF  Lin JM  Su RG  Cai ZW  Uchiyama K 《Electrophoresis》2005,26(9):1825-1833
A protocol of producing multiple polymeric masters from an original glass master mold has been developed, which enables the production of multiple poly(dimethylsiloxane) (PDMS)-based microfluidic devices in a low-cost and efficient manner. Standard wet-etching techniques were used to fabricate an original glass master with negative features, from which more than 50 polymethylmethacrylate (PMMA) positive replica masters were rapidly created using the thermal printing technique. The time to replicate each PMMA master was as short as 20 min. The PMMA replica masters have excellent structural features and could be used to cast PDMS devices for many times. An integration geometry designed for laser-induced fluorescence (LIF) detection, which contains normal deep microfluidic channels and a much deeper optical fiber channel, was successfully transferred into PDMS devices. The positive relief on seven PMMA replica masters is replicated with regard to the negative original glass master, with a depth average variation of 0.89% for 26-microm deep microfluidic channels and 1.16% for the 90 mum deep fiber channel. The imprinted positive relief in PMMA from master-to-master is reproducible with relative standard deviations (RSDs) of 1.06% for the maximum width and 0.46% for depth in terms of the separation channel. The PDMS devices fabricated from the PMMA replica masters were characterized and applied to the separation of a fluorescein isothiocyanate (FITC)-labeled epinephrine sample.  相似文献   

7.
The fabrication of polymer microchips allows inexpensive, durable, high-throughput and disposable devices to be made. Poly(methylmethacrylate) (PMMA) microchips have been fabricated by hot embossing microstructures into the substrate followed by bonding a cover plate. Different surface modifications have been examined to enhance substrate and cover plate adhesion, including: air plasma treatment, and both acid catalyzed hydrolysis and aminolysis of the acrylate to yield carboxyl and amine-terminated PMMA surfaces. Unmodified PMMA surfaces were also studied. The substrate and cover plate adhesion strengths were found to increase with the hydrophilicity of the PMMA surface and reached a peak at 600 kN m(-2) for plasma treated PMMA. A solvent assisted system has also been designed to soften less than 50 nm of the surface of PMMA during bonding, while still maintaining microchannel integrity. The extent to which both surface modifications and solvent treatment affected the adhesion of the substrate to the cover plate was examined using nanoindentation methods. The solvent bonding system greatly increased the adhesion strengths for both unmodified and modified PMMA, with a maximum adhesion force of 5500 kN m(-2) achieved for unmodified PMMA substrates. The bond strength decreased with increasing surface hydrophilicity after solvent bonding, a trend that was opposite to what was observed for non-solvent thermal bonding.  相似文献   

8.
Direct immobilisation of modified DNA oligonucleotides (aminated or thiolated) onto a plastic substrate, poly(methylmethacrylate), (PMMA) is described. Using the methyl esters present on non-modified PMMA, it was possible to establish a covalent bond between the electron donor of a DNA probe and the C terminal ester of the PMMA substrate. Since the procedure consists of a single brief wash in isopropanol or ethanol, the procedure is simple and environmentally friendly. The new immobilization strategy was characterized by analysing DNA microarray performance. The new procedure resulted in probe- and hybridization densities that were greater or equivalent to those obtained with commercially available surfaces and other procedures to immobilize DNA onto PMMA. The described chemistry selectively immobilized the DNA via terminal thiol or amine groups indicating that probe orientation could be controlled. Furthermore, the chemical bond between the immobilized DNA and the PMMA could endure repeated heat cycling with only 50% probe loss after 20 cycles, indicating that the chemistry could be used in integrated PCR/microarray devices.  相似文献   

9.
A simple method based on electric heating wires has been developed for the rapid fabrication of poly(methyl methacrylate) (PMMA) electrophoresis microchips in ordinary laboratories without the need for microfabrication facilities. A piece of stretched electric heating wire placed across the length of a PMMA plate along its midline was sandwiched between two microscope slides under pressure. Subsequently, alternating current was allowed to pass through the wire to generate heat to emboss a separation microchannel on the PMMA separation channel plate at room temperature. The injection channel was fabricated using the same procedure on a PMMA sheet that was perpendicular to the separation channel. The complete microchip was obtained by bonding the separation channel plate to the injection channel sheet, sealing the channels inside. The electric heating wires used in this work not only generated heat; they also served as templates for embossing the microchannels. The prepared microfluidic microchips have been successfully employed in the electrophoresis separation and detection of ions in connection with contactless conductivity detection.  相似文献   

10.
We report an ultra-rapid prototyping technique for forming microchannel networks for lab-on-a-chip applications, called masters on-demand. Channels are produced by replica molding on masters formed by laser printing on flexible copper printed circuit board (PCB) substrates. Masters of various designs and dimensions can be individually or mass produced in less than 10 minutes. Using this technique, we have fabricated channels as narrow as 100 microm with heights ranging between 9 microm and 70 microm. Multi-depth channel fabrication is also reported, using a two-step printing process. The functionality of devices formed in this manner is verified by performing in-channel electrophoretic separations and culture and analysis of primary mammalian cells.  相似文献   

11.
An integrated and modular DNA analysis system is reported that consists of two modules: (i) A continuous flow polymerase chain reaction (CFPCR) module fabricated in a high T(g) (150°C) polycarbonate substrate in which selected gene fragments were amplified using biotin and fluorescently labeled primers accomplished by continuously shuttling small packets of PCR reagents and template through isothermal zones as opposed to heating and cooling large thermal masses typically performed in batch-type thermal reactors. (ii) μCE (micro-capillary electrophoresis) module fabricated in poly(methylmethacrylate) (PMMA), which utilized a bioaffinity selection and purification bed (2.9 μL) to preconcentrate and purify the PCR products generated from the CFPCR module prior to electrophoretic sorting. Biotin-labeled CFPCR products were hydrostatically pumped through the streptavidin-modified bed, where they were extracted onto the surface of micropillars. The affinity bed was also fabricated in PMMA and was populated with an array of microposts (50 μm width; 100 μm height) yielding a total surface area of ~117 mm(2). This solid-phase extraction (SPE) process demonstrated high selectivity for biotinylated amplicons and utilized the strong streptavidin/biotin interaction (K(d) = 10(-15) M) to generate high recoveries. The SPE selected CFPCR products were thermally denatured and single-stranded DNA released for injection into a 7-cm-long μCE channel for size-based separations and fluorescence detection. The utility of the system was demonstrated using Alu DNA typing for gender and ethnicity determinations as a model. Compared with the traditional cross-T injection procedure typically used for μCE, the affinity pre-concentration and injection procedure generated signal enhancements of 17- to 40-fold, critical for CFPCR thermal cyclers due to Taylor dispersion associated with their operation.  相似文献   

12.
The design, fabrication and testing of a photolithographically fabricated, glass-based multireflection absorbance cell for microfluidic devices, in particular microchip-based capillary electrophoresis (CE) systems is described. A multireflection cell was fabricated lithographically using a three-mask process to pattern aluminum mirrors above and below a flow channel in a chip, with 30 microm diameter optical entrance or exit apertures (one in each mirror) positioned 200 microm apart. Source and detector were positioned on opposite sides, and the metal mirrors were made 1 cm square, to reduce stray light effects. Calibration curves using bromothymol blue (BTB) with a 633 nm source (He:Ne laser) were linear to at least 0.5 absorbance units, with typical r2 values of 0.9997, relative standard deviations in the slopes of +/- 1.3%, and intercepts of zero within experimental error. Effective optical pathlengths of 50-272 microm were achieved, compared to single-pass pathlengths of 10-30 microm, corresponding to sensitivity enhancements (i.e., optical path length increase) of 5 to 10-fold over single-pass devices. Baseline absorbance noise varied within a factor of two in almost all devices, depending only weakly on path length. This device can give much higher absorbance sensitivity, and should be much easier to manufacture than planar, glass-based devices previously reported.  相似文献   

13.
Stem and progenitor cells can be combined with polymer substrates to generate tissue equivalents in culture. The replacement of retinal tissue lost to disease or trauma using retinal progenitor cells (RPCs) delivered on polymer scaffolds and transplanted into the sub-retinal space of the damaged retina is a promising therapeutic strategy. Micromachining-based, ultra-thin PMMA poly(methyl methacrylate) scaffolds may provide a suitable cytoarchitectural environment for tissue engineering and transplantation to the diseased eye. Here, adhesion of RPCs to polymer, as well as migration and differentiation in the host retina were compared for PMMA scaffolds (6 microm thickness) with either smooth or porous (11 microm diameter) surface topography. RPCs were cultured under identical conditions on smooth or porous laminin-coated polymer scaffolds and transplanted into the subretinal space of C57BL/6 mice. RPCs could be cultured on both scaffolds with similar results, although transplantation with non-porous scaffolds showed limited RPC retention. Porous scaffolds demonstrated enhanced RPC adherence during transplantation and allowed for greater process outgrowth and cell migration into the host retinal layers. Integrated cells expressed the mature neuronal marker neurofilament-200 (nf-200), the glial marker glial fibrillary acidic protein (GFAP) and the retinal-specific marker recoverin. No host foreign body response was seen. In conclusion, ultra-thin film PMMA scaffolds micromachined to contain through pores retain adherent RPCs to a considerably greater extent than unmachined versions during the transplantation process and can serve as a biocompatible substrate for cell delivery in vivo.  相似文献   

14.
An automated proteolytic digestion bioreactor and droplet deposition system was constructed with a plastic microfluidic device for off-line interfacing to matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The microfluidic chips were fabricated in poly(methyl methacrylate) (PMMA), using a micromilling machine and incorporated a bioreactor, which was 100 microm wide, 100 microm deep, and possessed a 4 cm effective channel length (400 nL volume). The chip was operated by pressure-driven flow and mounted on a robotic fraction collector system. The PMMA bioreactor contained surface immobilized trypsin, which was covalently attached to the UV-modified PMMA surface using coupling reagents N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and hydroxysulfosuccinimide (sulfo-NHS). The digested peptides were mixed with a MALDI matrix on-chip and deposited as discrete spots on MALDI targets. The bioreactor provided efficient digestion of a test protein, cytochrome c, at a flow rate of 1 microL/min, producing a reaction time of approximately 24 s to give adequate sequence coverage for protein identification. Other proteins were also evaluated using this solid-phase bioreactor. The efficiency of digestion was evaluated by monitoring the sequence coverage, which was 64%, 35%, 58%, and 47% for cytochrome c, bovine serum albumin (BSA), myoglobin, and phosphorylase b, respectively.  相似文献   

15.
The use of CO(2) laser ablation for the patterning of capillary electrophoresis (CE) microchannels in poly(dimethylsiloxane)(PDMS) is described. Low-cost polymer devices were produced using a relatively inexpensive CO(2) laser system that facilitated rapid patterning and ablation of microchannels. Device designs were created using a commercially available software package. The effects of PDMS thickness, laser focusing, power, and speed on the resulting channel dimensions were investigated. Using optimized settings, the smallest channels that could be produced averaged 33 microm in depth (11.1% RSD, N= 6) and 110 microm in width (5.7% RSD, N= 6). The use of a PDMS substrate allowed reversible sealing of microchip components at room temperature without the need for cleanroom facilities. Using a layer of pre-cured polymer, devices were designed, ablated, and assembled within minutes. The final devices were used for microchip CE separation and detection of the fluorescently labeled neurotransmitters aspartate and glutamate.  相似文献   

16.
This paper presents a new electrochemical method for the detection and characterisation of aqueous droplets in an organic carrier fluid (1,2-dichloroethane) formed in flow-focusing microfluidic devices. The devices consist of a conventional flow-focusing channel 250 microm wide and 250 microm deep cast out of poly(dimethylsiloxane) (PDMS) which is sealed onto a glass substrate containing a set of microelectrodes 100 microm long. Chronoamperometric analysis of a suitable electrolyte contained in the organic phase is presented for characterising the droplet frequency and size. This chronoamperometric method is then extended to a dual working electrode approach in order to determine the velocity of the droplet. Good agreement between experimental measurements and theory was observed.  相似文献   

17.
We demonstrate a new and flexible microfluidic based method for genotyping single nucleotide polymorphisms (SNPs). The method relies on size separation of selectively hybridized polystyrene microspheres in a microfluidic pinched flow fractionation (PFF) device. The microfluidic PFF devices with 13 mum deep channels were fabricated by thermal nanoimprint lithography (NIL) in a thin film of cyclic-olefin copolymer (mr-I T85) on a silicon wafer substrate, and the channels were sealed by thermal polymer bonding. Streptavidin coated polystyrene microspheres with a mean diameter of 3.09 microm and 5.6 microm were functionalized with biotin-labeled oligonucleotides for the detection of a mutant (Mt) or wild-type (Wt) DNA sequence in the HBB gene, respectively. Hybridization to functionalized beads was performed with fluorescent targets comprising synthetic DNA oligonucleotides or amplified RNA, synthesized using human DNA samples from individuals with point mutations in the HBB gene. Following a stringent wash, the beads were separated in a PFF device and the fluorescent signal from the beads was analyzed. Patients being wildtypes, heterozygotes or mutated respectively for the investigated mutation could reliably be diagnosed in the PFF device. This indicates that the PFF technique can be used for accurate and fast genotyping of SNPs.  相似文献   

18.
Polymers are important as materials for manufacturing microfluidic devices for electrodriven separations, in which Joule heating is an unavoidable phenomenon. Heating effects were investigated in polymer capillaries using a CE setup. This study is the first step toward the longer-term objective of the study of heating effects occurring in polymeric microfluidic devices. The thermal conductivity of polymers is much smaller than that of fused silica (FS), resulting in less efficient dissipation of heat in polymeric capillaries. This study used conductance measurements as a temperature probe to determine the mean electrolyte temperatures in CE capillaries of different materials. Values for mean electrolyte temperatures in capillaries made of New Generation FluoroPolymer (NGFP), poly-(methylmethacrylate) (PMMA), and poly(ether ether ketone) (PEEK) capillaries were compared with those obtained for FS capillaries. Extrapolation of plots of conductance versus power per unit length (P/L) to zero power was used to obtain conductance values free of Joule heating effects. The ratio of the measured conductance values at different power levels to the conductance at zero power was used to determine the mean temperature of the electrolyte. For each type of capillary material, it was found that the average increase in the mean temperature of the electrolyte (DeltaT(Mean)) was directly proportional to P/L and inversely proportional to the thermal conductivity (lambda) of the capillary material. At 7.5 W/m, values for DeltaT(Mean) for NGFP, PMMA, and PEEK were determined to be 36.6, 33.8, and 30.7 degrees C, respectively. Under identical conditions, DeltaT(Mean) for FS capillaries was 20.4 degrees C.  相似文献   

19.
Mixed-scale nano- and microfluidic networks were fabricated in thermoplastics using simple and robust methods that did not require the use of sophisticated equipment to produce the nanostructures. High-precision micromilling (HPMM) and photolithography were used to generate mixed-scale molding tools that were subsequently used for producing fluidic networks into thermoplastics such as poly(methyl methacrylate), PMMA, cyclic olefin copolymer, COC, and polycarbonate, PC. Nanoslit arrays were imprinted into the polymer using a nanoimprinting tool, which was composed of an optical mask with patterns that were 2-7 μm in width and a depth defined by the Cr layer (100 nm), which was deposited onto glass. The device also contained a microchannel network that was hot embossed into the polymer substrate using a metal molding tool prepared via HPMM. The mixed-scale device could also be used as a master to produce a polymer stamp, which was made from polydimethylsiloxane, PDMS, and used to generate the mixed-scale fluidic network in a single step. Thermal fusion bonding of the cover plate to the substrate at a temperature below their respective T(g) was accomplished by oxygen plasma treatment of both the substrate and cover plate, which significantly reduced thermally induced structural deformation during assembly: ~6% for PMMA and ~9% for COC nanoslits. The electrokinetic transport properties of double-stranded DNA (dsDNA) through the polymeric nanoslits (PMMA and COC) were carried out. In these polymer devices, the dsDNA demonstrated a field-dependent electrophoretic mobility with intermittent transport dynamics. DNA mobilities were found to be 8.2 ± 0.7 × 10(-4) cm(2) V(-1) s(-1) and 7.6 ± 0.6 × 10(-4) cm(2) V(-1) s(-1) for PMMA and COC, respectively, at a field strength of 25 V cm(-1). The extension factors for λ-DNA were 0.46 in PMMA and 0.53 in COC for the nanoslits (2-6% standard deviation).  相似文献   

20.
While polymer-based microfluidic devices offer some unique opportunities in developing low-cost systems for a variety of application areas, the ability to sort electrophoretically with high efficiency a number of different targets has remained somewhat elusive with an example consisting of achieving single base resolution as required for DNA sequencing. While the reasons for this are many-fold, it is clear that some type of coating is required on the polymer substrate to suppress the EOF and/or minimize potential solute/wall interactions. To this end, we report on a simple grafting procedure to allow the formation of polymer coats, which in this example used linear polyarcylamides (LPAs), onto a poly(methyl methacrylate) (PMMA) microfluidic device. The procedure involved creating an amine-terminated PMMA surface by appropriately functionalizing the PMMA through either a chemical or photochemical process. The aminated surface could then be used to covalently anchor methacrylic acid, which was used as a scaffold to produce LPAs on the surface through radical polymerization of acrylamide. The resulting surfaces demonstrated EOFs that were nearly an order of magnitude smaller than native PMMA. In addition, these LPA-coated devices could produce highly reproducible migration times of over approximately 20 runs with plate numbers exceeding 10(5) m(-1). Using gel electrophoretic analysis of a single base track generated from an M13mp18 template using Sanger cycle sequencing and dye-primer chemistry, the resolution value obtained for bases 199 and 200 was 0.18 while for bases 208 and 209 it was 0.21. For the native PMMA, these bands were found to comigrate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号