首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We present a new approach for contactless conductivity detection for microchip-based capillary electrophoresis (CE). The detector integrates easily with well-known microfabrication techniques for glass-based microfluidic devices. Platinum electrodes are structured in recesses in-plane with the microchannel network after glass etching, which allows precise positioning and batch fabrication of the electrodes. A thin glass wall of 10-15 microm separates the electrodes and the buffer electrolyte in the separation channel to achieve the electrical insulation necessary for contactless operation. The effective separation length is 34 mm, with a channel width of 50 microm and depth of 12 microm. Microchip CE devices with conductivity detection were characterized in terms of sensitivity and linearity of response, and were tested using samples containing up to three small cations. The limit of detection for K+ (18 microM) is good, though an order of magnitude higher than for comparable capillary-based systems and one recently reported example of contactless conductivity on chip. However, an integrated field-amplified stacking step could be employed prior to CE to preconcentrate the sample ions by a factor of four.  相似文献   

2.
建立了微芯片毛细管电泳非接触电导检测法快速测定盐酸倍他洛尔滴眼液中盐酸倍他洛尔的含量。探讨了缓冲液类型、浓度、分离电压及进样时间等因素对分离检测的影响。实验采用1.5 mmol·L-1HAc-1.5mmol·L-1Na Ac(p H=4.69)为缓冲溶液,分离电压为2.1 k V,进样时间10.0 s。此条件下于0.7 min内实现了盐酸倍他洛尔的快速分离测定。盐酸倍他洛尔的浓度在5.0~200.0μg·m L-1线性良好(r=0.9997,n=6),检出限为1.0μg·m L-1(S/N=3),RSD为0.8%,样品的加标回收率为100.4%~102.0%。滴眼液中的辅料在该条件下不干扰测定,可成功测定盐酸倍他洛尔滴眼液中盐酸倍他洛尔的含量。  相似文献   

3.
A new end-column ‘hybrid’ contactless conductivity detector for microchip capillary electrophoresis (CE) was developed. It is based on a “hybrid” arrangement where the receiving electrode is insulated by a thin layer of insulator and placed in the bulk solution of the detection reservoir of the chip, whereas the emitting electrode is in contact with the solution eluted from the channel outlet in a wall-jet arrangement. The favorable features of the new detector including the high sensitivity and low noise, can be attributed to both the direct contact of the ‘emitting’ electrode with the analyte solution as well as to the insulation of the detection electrode from the high DC currents in the electrophoretic circuit. Such arrangement provides a 10-fold sensitivity enhancement compared to currently used on-column contactless conductivity CE microchip detector as well as low values of noise and easy operation. The new design of the wall-jet conductivity detector was tested for separation of explosive-related methylammonium, ammonium, and sodium cations. The new detector design reconsiders the wall-jet arrangement for microchip conductivity detection in scope of improved peak symmetry, simplified study of inter-electrode distance, isolation of the electrodes, position of the wall-jet electrode to the separation channel, baseline stability and low limits of detection.  相似文献   

4.
An integrated detection circuitry based on a lock-in amplifier was designed for contactless conductivity determination of heavy metals. Combined with a simple-structure electrophoresis microchip, the detection system is successfully utilized for the separation and determination of various heavy metals. The influences of the running buffer and detection conditions on the response of the detector have been investigated. Six millimole 2-morpholinoethanesulfonic acid + histidine were selected as buffer for its stable baseline and high sensitivity. The best signals were recorded with a frequency of 38 kHz and 20 V(pp). The results showed that Mn(2+), Cd(2+), Co(2+), and Cu(2+) can be successfully separated and detected within 100 s by our system. The detection limits for five heavy metals (Mn(2+), Pb(2+), Cd(2+), Co(2+), and Cu(2+)) were determined to range from about 0.7 to 5.4 μM. This microchip system performs a crucial step toward the realization of a simple, inexpensive, and portable analytical device for metal analysis.  相似文献   

5.
A microfabricated thin glass chip for contactless conductivity detection in chip capillary electrophoresis is presented in this contribution. Injection and separation channels were photolithographed and chemically etched on the surface of substrate glass, which was bonded with a thin cover glass (100 μm) to construct a new microchip. The chip was placed over an independent contactless electrode plate. Owing to the thinness between channel and electrodes, comparatively low excitation voltage (20–110 V in Vp–p) and frequency (40–65 kHz) were suitable, and favorable signal could be obtained. This microchip capillary electrophoresis device was used in separation and detection of inorganic ions, amino acids and alkaloids in amoorcorn tree bark and golden thread in different buffer solutions. The detection limit of potassium ion was down to 10 μmol/L. The advantages of this microchip system exist in the relative independence between the microchip and the detection electrodes. It is convenient to the replacement of chip and other operations. Detection in different position of the channel would also be available.  相似文献   

6.
A contactless conductivity detector integrated into a poly(dimethylsiloxane) microchip for electrophoresis is presented. It adopted the simplest configuration of electrodes commonly used in this detection mode for capillary electrophoresis microchips. Although the chip is based on a simple and effective design, it is able to obtain low detection levels due to the low noise of the detection circuit. A circuit based on a lock-in amplifier was designed on printed circuit boards to read out the signal. The property of the detection cell was studied by applying excitation signals of different frequencies and different amplitudes. It was found that the best detection limit could be achieved with a frequency of 50?kHz and amplitude of 20?V. The performance of the detector was demonstrated by successfully separating and detecting several inorganic ions and also a mixture of heavy metal ions. An average detection limit of 0.4?μM was obtained for inorganic cations. This value is significantly improved compared to similar microchip-based detectors. The presented detector could be promising for mass production due to its properties, such as simple construction, high degree of integration, high performance and low cost.  相似文献   

7.
Recent advances and key strategies in capillary electrophoresis and microchip CE with electrochemical detection (ECD) and electrochemiluminescence (ECL) detection are reviewed. This article consists of four main parts: CE-ECD; microchip CE-ECD; CE-ECL; and microchip CE-ECL. It is expected that ECD and ECL will become powerful tools for CE microchip systems and will lead to the creation of truly disposable devices. The focus is on papers published in the last two years (from 2005 to 2006).  相似文献   

8.
Herein, we summarize the current status of native fluorescence detection in microchannel electrophoresis, with a strong focus on chip-based systems. Fluorescence detection is a powerful technique with unsurpassed sensitivity down to the single-molecule level. Accordingly fluorescence detection is attractive in combination with miniaturised separation techniques. A drawback is, however, the need to derivatize most analytes prior to analysis. This can often be circumvented by utilising excitation light in the UV spectral range in order to excite intrinsic fluorescence. As sensitive absorbance detection is challenging in chip-based systems, deep-UV fluorescence detection is currently one of the most general optical detection techniques in microchip electrophoresis, which is especially attractive for the detection of unlabelled proteins. This review gives an overview of research on native fluorescence detection in capillary (CE) and microchip electrophoresis (MCE) between 1998 and 2008. It discusses material aspects of native fluorescence detection and the instrumentation used, with particular focus on the detector design. Newer developments, featured techniques, and their prospects in the future are also included. In the last section, applications in bioanalysis, drug determination, and environmental analysis are reviewed with regard to limits of detection.  相似文献   

9.
Clinical studies have linked irregular concentrations of uric acid in urine to several diseases. Conventional methods for the measurement of uric acid are however temperature-dependent, expensive, and require labile reagents. The miniaturization of analytical techniques, specifically capillary electrophoresis, offers an ideal alternative for clinical analyses such as uric acid determination. The added benefits include reduced reagent and analyte consumption, decreased maintenance costs, and increased throughput and portability. A microchip capillary electrophoresis-electrochemical system for the analysis of uric acid in urine is described. The poly(dimethylsiloxane) (PDMS)/glass microchip utilizes amperometric detection via an off-chip platinum working electrode. Linear responses from 1 to 165 microM and 15 to 110 microM were found for dopamine and uric acid, respectively. The limit of detection for both compounds was 1 microM. Once characterized, the system was used to measure the concentration of uric acid in a dilute urine sample in less than 30 s. The measured uric acid concentration was verified with the uricase reaction and found to be acceptable. Six additional urine samples were evaluated with the microchip device and the uric acid concentration for each sample was found to be in the expected clinical concentration range.  相似文献   

10.
A simple, rapid method using CE and microchip electrophoresis with C4D has been developed for the separation of four nonsteroidal anti-inflammatory drugs (NSAIDs) in the environmental sample. The investigated compounds were ibuprofen (IB), ketoprofen (KET), acetylsalicylic acid (ASA), and diclofenac sodium (DIC). In the present study, we applied for the first time microchip electrophoresis with C4D detection to the separation and detection of ASA, IB, DIC, and KET in the wastewater matrix. Under optimum conditions, the four NSAIDs compounds could be well separated in less than 1 min in a BGE composed of 20 mM His/15 mM Tris, pH 8.6, 2 mM hydroxypropyl-beta-cyclodextrin, and 10% methanol (v/v) at a separation voltage of 1000–1200 V. The proposed method showed excellent repeatability, good sensitivity (LODs ranging between 0.156 and 0.6 mg/L), low cost, high sample throughputs, portable instrumentation for mobile deployment, and extremely lower reagent and sample consumption. The developed method was applied to the analysis of pharmaceuticals in wastewater samples with satisfactory recoveries ranging from 62.5% to 118%.  相似文献   

11.
Kubán P  Hauser PC 《Lab on a chip》2008,8(11):1829-1836
The determination of inorganic ions in clinical samples in less than 90 seconds was demonstrated for microchip capillary electrophoresis using capacitively coupled contactless conductivity detection (C(4)D). Bare electrophoresis chips were used in combination with external electrodes which were part of the chip holder. In order to achieve the required selectivity and sensitivity, an optimization of the electrode layout was carried out. Limits of detection (LOD) of 1 microM for K(+), 1.5 microM for Ca(2+), 3 microM for Na(+), 1.75 microM for Mg(2+) and 7.5 microM for Li(+) were achieved. The determination of inorganic cations (NH(4)(+), K(+), Na(+), Ca(2+), Mg(2+)) and anions (Cl(-), NO(3)(-), SO(4)(2-), phosphate) in blood serum and urine samples was possible in one common electrolyte solution containing 15 mM L-arginine, 10.75 mM maleic acid and 1.5 mM 18-crown-6 at pH 5.90 by simply switching the separation voltage from positive to negative polarity. Lithium, present at significant levels when used for therapeutic purposes, can also be determined in blood serum using a slightly modified background electrolyte solution.  相似文献   

12.
Chen G  Lin Y  Wang J 《Talanta》2006,68(3):497-503
During the past decade, significant progress in the development of miniaturized microfluidic systems has occurred due to the numerous advantages of microchip analysis. This review focuses on recent advances and the key strategies in microchip capillary electrophoresis (CE) with electrochemical detection (ECD) for separating and detecting a variety of environmental pollutants. The subjects covered include the fabrication of microfluidic chips, ECD, typical applications of microchip CE with ECD in environmental analysis, and future prospects. It is expected that microchip CE-ECD will become a powerful tool in the environmental field and will lead to the creation of truly portable devices.  相似文献   

13.
The interest in microfluidic devices has increased considerably over the past decade due to the numerous advantages of working within a miniature, microfabricated format. This review focuses on recent advances in coupling amperometric detection with microchip capillary electrophoresis (CE). Advances in electrochemical cell design, isolation of the detector from the separation field, and integration of both pre- and postseparation reaction chambers are discussed. The use of microchip CE with amperometric detection for enzyme/immunoassays, clinical and environmental assays, and the determination of neurotransmitters is described.  相似文献   

14.
Phenol, 2,4-dichlorophenol (2,4-DCP), and 2,4,6-trichlorophenol (2,4,6-TCP) were baseline separated by using a homemade microchip CE with an end-channel amperometric detector where a 50 microm Pt microdisk working electrode (WE) and a Pt cathode were integrated onto the microchip itself. Separation parameters such as injection time and voltage, pH of the buffer, online pretreatment condition for WE, reproducibility, and detection potential were investigated. Under the selected separation conditions, the linear ranges for phenol, 2,4-DCP, and 2,4,6-TCP were 2-200, 4-400, and 4-400 microM, respectively. The LODs were 0.4, 0.5, and 0.7 microM for phenol, 2,4-DCP, and 2,4,6-TCP, respectively (S/N = 3). The standard addition method was successfully applied to the analysis of landfill leachate samples and the concentration of phenol in the landfill leachate samples was measured to be 0.32 and 0.21 mM, respectively. The recoveries were in the range of 85-103% and corresponding RSDs were less than 5.5%.  相似文献   

15.
Significant progress in the development of miniaturized microfluidic systems has occurred since their inception over a decade ago. This is primarily due to the numerous advantages of microchip analysis, including the ability to analyze minute samples, speed of analysis, reduced cost and waste, and portability. This review focuses on recent developments in integrating electrochemical (EC) detection with microchip capillary electrophoresis (CE). These detection modes include amperometry, conductimetry, and potentiometry. EC detection is ideal for use with microchip CE systems because it can be easily miniaturized with no diminution in analytical performance. Advances in microchip format, electrode material and design, decoupling of the detector from the separation field, and integration of sample preparation, separation, and detection on-chip are discussed. Microchip CEEC applications for enzyme/immunoassays, clinical and environmental assays, as well as the detection of neurotransmitters are also described.  相似文献   

16.
Nanomaterials have drawn much attention because of their unique properties enabling them to play important roles in various applications in different areas. This review covers literature data in the Web of Science from January 2017 to August 2020, focusing on the applications of nanomaterials (nanoparticles, quantum dots, nanotubes, and graphene) in CE and MCE to achieve enhanced sensitivity of several detection techniques: fluorescence, colorimetry, amperometry, and chemiluminescence /electrochemiluminescence. For the articles surveyed, the types of nanomaterials used, detection mechanisms, analytical performance, and applications are presented and discussed.  相似文献   

17.
Law WS  Kubán P  Zhao JH  Li SF  Hauser PC 《Electrophoresis》2005,26(24):4648-4655
The separation and detection of commonly used preservatives (benzoate, sorbate) and vitamin C by both conventional CE and microchip electrophoresis with capacitively coupled contactless conductivity detection is presented. The separation was optimized by adjusting the pH-value of the buffer and the use of hydroxypropyl-beta-CD (HP-beta-CD) and CTAB as additives. For conventional CE, optimal separation conditions were achieved in a histidine/tartrate buffer at pH 6.5, containing 0.025% HP-beta-CD and 0.1 mM CTAB. LOD ranged from 0.5 to 3 mg/L (S/N = 3) and the RSDs for migration time and peak area were less than 0.1 and 2%, respectively. A considerable reduction of analysis time can be accomplished by using microchip electrophoresis without significant loss in sensitivity under optimal separation conditions. A histidine/tartrate buffer at pH 6.5, incorporating 0.06% HP-beta-CD and 0.25 mM CTAB, gave detection limits ranging between 3 and 10 mg/L and satisfactory reproducibilities of < or =0.4% for the migration time and < or =3.5% for the peak area. The methods developed are useful for the quantitative determination of food additives in real samples such as soft drinks and vitamin C tablets.  相似文献   

18.
Tanyanyiwa J  Hauser PC 《Electrophoresis》2004,25(17):3010-3016
The extension of contactless conductivity detection in electrophoresis to the determination of basic drugs is demonstrated using beta-adrenergic blocking agents (beta-blockers) and other physiologically active amines as examples. The high-voltage approach to conductivity detection was employed for conventional capillaries as well as microchip devices. Acidic buffers were used in all cases. A buffer consisting of 100 mM acetic acid and 1 mM histidine was deemed most optimal for the separation of six beta-blockers and best results for the analysis of the other amines were achieved with a 20 mM lactic acid buffer at low pH-value. The detection limits ranged from 0.06 to 5 microM. To demonstrate potential practical applications, a main component assay was conducted for three pharmaceutical formulations. On-chip, five pharmaceutical amines could be baseline-resolved in a 8 cm long microchannel in 90 s, albeit a reduced sensitivity and peak capacity compared to conventional capillary electrophoresis.  相似文献   

19.
The quantification of plasma lactate and evaluation of the lactate threshold by CE with capacitively coupled contactless conductivity is demonstrated. The only sample preparation needed was deproteinization with a ACN/methanol mixture. A solution of 10 mmol/L 2-morpholinoethanesulfonic acid monohydrate, 10 mmol/L DL-histidine, 70 μmol/L hexadecyltrimethylammonium bromide, pH 6.0 was found suitable as running buffer. Linearity was achieved for the concentration range of 10-1000 μmol/L with a correlation coefficient of 0.9994. The limit of detection (3 S/N) was determined as 3.2 μmol/L. Intra- and inter-day variabilities were less than 7% RSD. The suitability of the method could be demonstrated by analyzing various clinical samples, where the results correlated satisfactorily with those of an established enzymatic method.  相似文献   

20.
The sensitivity of contactless conductivity detection to amino acids, peptides and proteins in CE was studied for BGE solutions of different pH values. The LOD and analytical characteristics were compared for acidic and basic conditions and better results were in most cases found for buffers of low pH values. Linear dynamic ranges varied between two orders of magnitude for amino acids and peptides and three orders of magnitude for larger proteins. The concentration detection limits were found to be between 1.2 and 7.5 microM for the amino acids tested and for the larger molecules they varied between 2.6 microM for leucine enkephalin and 0.2 microM for HSA when using a buffer at pH 2.1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号