首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary An electrodialytic sample treatment method coupled on-line with high-performance liquid chromatography (EDIST-HPLC) is discussed in this paper. The performance of EDIST as a function of the donor-phase (sample solution) flow rate, the voltage applied over the electrodialysis block, and the time of dialysis has been studied using the basic drug ephedrine as a model compound. Enrichment of the analyte by a factor of 10–20 was possible. The determination of human plasma spiked with ephedrine is briefly discussed.  相似文献   

2.
Recently, a new fully endcapped reversed-phase packing material, Inertsil, was introduced, especially suitable for the determination of basic compounds. We used this packing material to separate o-phthaldialdehyde (OPA) derivatives of amino acid derivatives completely from the OPA derivatives of spermine (SPM), spermidine (SPD), putrescine (PUT) and cadaverine (CAD). The obtained separation made the commonly used off-line extraction procedure redundant and thus an on-line sample clean-up was introduced. This enabled automation of the procedure resulting in a better reproducibility and a more efficient use of equipment. Furthermore, no studies are required to determine the extraction recovery.

The present method has a cycle time of 30 min. A linear response for each polyamine was found up to 250 pmol, with an R2 ranging from 0.9981 (SPM) to 0.9998 (CAD). The limit of detection, calculated at a signal-to-noise ratio of 3, was 0.1 pmol, corresponding to a plasma concentration of 0.1 μmol/l. The coefficient of variation (CV) for the peak area was below 3% and for retention times below 0.5% (n=15).

In order to evaluate the applicability of the method, three different types of sample were chromatographed, e.g. urine (obtained from healthy human volunteers), pig plasma and sulfosalicylic acid homogenates of pig intestine biopsies. Tissue homogenates and urine-specimen could easily be quantitated, while plasma concentrations were just above the limit of detection, resulting in a plasma CV ranging from 4.8% (SPM) to 13.6% (SPD) and a tissue CV ranging from 2.1% (SPM) to 8.5% (CAD), The urinary CVs were not determined.

In conclusion, the present method provides an easy way to measure polyamine concentrations for most applications.  相似文献   


3.
The automation of zone-electrophoretic sample treatment for liquid chromatography is described. The procedure is completely controlled from a liquid chromatograph. The carry-over of proteins from human serum under different experimental conditions was studied. The influence of the presence of proteins in the sample is illustrated with the anionic compound salicylic acid and the increase in selectivity for cationic compounds is demonstrated with the determination of ephedrine, norephedrine and amphetamine in urine.  相似文献   

4.
While LC finds enormously widespread use in almost all areas of chemical science, the technique is limited as a means of identification because compounds do not elute with unique retention times. This limitation spurred the growth of hyphenated instrumental methods of analysis, such as LC-MS/MS, which because of the MS/ MS detection became a method of identification. However, techniques like LC-MS/ MS are specialised and require high initial purchase and running costs, inhibiting the more widespread growth of the technique. In an attempt to increase the separation power of LC, multi-dimensional LC was developed. This expanded the separation space and subsequently has allowed the development of methods with fingerprinting ability due to the lower probability of component overlap. The work in this study illustrates the application of 2-D LC as a means of chemical fingerprinting. We employed a sample base of various low molecular weight oligostyrenes and their diastereomers that represent a population of compounds whose selectivities in a one-dimensional separation are almost unity and hence essentially impossible to separate. Yet in a 2-D domain almost all individual components occupy unique 2-D retention times.  相似文献   

5.
D. Berek  A. Russ 《Chemical Papers》2006,60(3):249-252
Complex polymer systems, which exhibit multiple distributions in their molecular parameters can be characterized by coupled liquid chromatographic methods. The latter combine entropic (exclusion) and enthalpic (interaction) retention mechanisms. However, recent experimental results suggest that some coupled liquid chromatographic methods may suffer from incomplete sample recovery. This refers, for example, to liquid chromatography under critical conditions of enthalpic interactions and to eluent gradient liquid chromatography. Sample recovery in both latter methods was investigated for selected model systems applying adsorption retention mechanism. Reduced sample recovery was confirmed for both methods. It was revealed that even very high final strength of mobile phase may be insufficient for complete elution of polymer samples in eluent gradient polymer liquid chromatography.  相似文献   

6.
The accurate determination of deoxyribonucleoside triphosphates in cells is difficult owing to the high concentrations of interfering ribonucleoside triphosphates. The latter can be degraded to their respective bases by periodate oxidation of cell extracts. However, the large amount of bases so produced can interfere with subsequent high-performance liquid chromatographic (HPLC) analysis. The use of a weak ion-exchange cartridge to partially purify and concentrate deoxyribonucleoside triphosphates in periodate-treated cell extracts, prior to HPLC, thus allowing accurate determination is described. The recovery of the deoxyribonucleoside triphosphates is greater than 95%, and greater than 90% of the interfering bases are removed.  相似文献   

7.
This article presents a systematic approach to investigate, document, and eliminate pharmaceutical HPLC assay bias using experimental design. This is the first article to describe the application of experimental design in the area of assay bias. It is found that both formulation and analytical variables can contribute to pharmaceutical HPLC assay bias using model compounds and formulations.  相似文献   

8.
Liu SS  Yang CX  Wang SW  Yan XP 《The Analyst》2012,137(4):816-818
Metal-organic framework MIL-53(Al) is explored for reverse-phase high-performance liquid chromatographic separation of a wide range of analytes from non-polar to polar, and acidic to basic solutes with high resolution, good selectivity, stability and reproducibility.  相似文献   

9.
A theoretical model is developed for the response of permittivity detectors working at radiofrequency for h.p.l.c. applications. Three types of cell were tested: a coil cell, a parallel-ring cell and a two-wire intrusive cell. All offer small cell volumes (ca. 700 nl for the coil cell, 9 nl for the parallel-ring cell and 40 nl for the intrusive two-wire cell). The last cell, with a 20-MHz Franklin oscillator, is shown to be most useful for conventional and microbore h.p.l.c., offering low instrument noise and reasonable sensitivity. The model is shown qualitatively to describe the observed response well. The coil cell also offers the possibility of monitoring conductivity changes in electrolyte solutions through frequency-change measurements. The theoretical response function indicates that the oscillator frequency is proportional to the square root of the eluate conductivity.  相似文献   

10.
The purpose of this review is to discuss the strategic problems of automating sample preparation (SP) for high performance liquid chromatography (HPLC). There is a general feeling that SP is the bottleneck of many HPLC procedures. Despite numerous reports of successful automation of SP, there are still many laboratories using manual or semiautomated SP procedures. This calls for a reevaluation of the present situation.  相似文献   

11.
A simple and rapid sample preparation method for the determination of chloramphenicol in swine muscle tissue at the 10 micrograms/kg level is described. The method comprises sonication-aided extraction with ethyl acetate, addition of hexane to the extract and cleaning up and concentration of the extract on a small column packed with silica gel. Analysis was performed by high-performance liquid chromatography on a ChromSep column with ChromSpher C8 using acetonitrile-sodium acetate buffer as the mobile phase. Detection was performed at 280 nm. Mean recoveries from spiked muscle samples were 79 +/- 3% (10-50 micrograms/kg). The distribution of chloramphenicol in different muscle and fatty tissues from a pig to which a single dose of chloramphenicol was administered was also investigated.  相似文献   

12.
A new calibration method for high-performance liquid chromatography was validated. The method was called single-injection calibration approach (SICA) because it allowed to obtain a complete calibration curve by means of a single injection of a standard solution containing several non-volatile and semi-volatile organic compounds at different concentration levels. The compounds studied included carboxylic acids, polyalcohols, carbohydrates and water-soluble vitamins. This method allowed a 1-7-fold reduction in the analysis time with regard to conventional calibration methods. The method was applied to three different chromatographic detection methods: refractive index (RI) detection, diode array detection (DAD) and inductively coupled plasma atomic emission detection (ICP-AED). Good linearity was achieved (r(2)>0.999) for the three detection methods but signal correction was required for RI detection and DAD. This fact demonstrated that ICP-AES was the most universal because the signal obtained for non-volatile and semi-volatile organic compounds was not a function of the chemical nature of the compound and only depended on the mass content of carbon. The method was validated by analyzing a reference non-fat milk powder sample as well as several real food samples (three fruit juices, four wines, three candies and a multivitamin complex).  相似文献   

13.
14.
The experimental anti-AIDS glycerophosphatidic acid: nucleoside (sn-1/sn-2 diacylglycerol:dideoxynucleotide) drugs 3'-azido-3'-deoxythymidine monophosphate diglyceride (AZT-MP-DG) and 2',3'-dideoxycytidine monophosphate diglyceride (ddC-MP-DG) were isolated and purified by reversed-phase high-performance liquid chromatography (HPLC). The chromatographic separation was based on the glycerophospholipid moiety of the drugs and detection of the nucleoside component. The separations were optimized on method development columns packed with the stationary phase to be used in the micro-preparative column and monitored by a UV detector. Fractions were collected and analyzed for purity by analytical-scale HPLC and by thin-layer chromatography (TLC). The purity of the recovered drugs based on UV and light-scattering detection and on TLC was greater than 99%. The purified compounds were isolated for studies on structure confirmation, physical, biophysical and formulation properties and anti-HIV efficacy in culture.  相似文献   

15.
This report describes a new microfluidic device called the H Filter for sample preparation prior to HPLC. The H Filters make possible a diffusional transfer of an analyte from a sample stream into a stream of a "receiver" fluid. Existing mathematical models can be used for optimizing experimental conditions. The authors have selected the extraction of the antibiotic cephradine from blood to demonstrate the utility of the new device. The extracts of blood samples spiked with cephradine levels between 0.2 and 100 microg/ml were analyzed using a C8 reversed-phase column and UV detection at 260 nm. The HPLC results were in good agreement with theory. The recovery of 32.2+/-2.8% was uniform over the entire range of cephradine concentrations. The new method completely avoids the use of centrifuges, that is otherwise typical for most current methodologies for the preparation of blood samples prior to HPLC analysis.  相似文献   

16.
17.
The protamines from the gonads of the sturgeonAcipenser stellatus have been separated by high-performance liquid chromatography. The proteins were eluted with mixtures of water and ethanol having a gradient of ethanol concentrations in the presence of trifluoroacetic acid (TFA). The influence of the concentration of TFA and the temperature of the column on separation was studied. The quantitative (95–98%) isolation of the protamines from the column was achieved at a temperature of 30°C and a 0.15% concentration of TFA.Moscow Technological Institute of the Meat and Dairy Industry. Translated from Khimiya Prirodnykh Soedinenii, No. 6, pp. 744–748, November–December, 1986.  相似文献   

18.
In this paper, the preparation of a new anion-exchange phase based on N-methylimidazolium immobilized on silica is described. HPLC separations of common inorganic anions, including an iodate, chloride, bromide, nitrate, iodide, and thiocyanate, were performed using a HPLC column (200 x 4.6mm I.D.) packed with the said phase, and phosphate buffer solution and acetate buffer solution as the mobile phases respectively, with UV detection at 200 nm. The effects of pH and the concentration of the eluent on the separation of anions were studied. With the efficiency and resolution of the column calculated, the results showed that this new phase can be used in the analysis of these in organic anions with great prospects. At the same time, successful separations of some organic anions, amines and nucleotides have also been obtained respectively using this new phase. The phase displayed a main strong anion-exchange mechanism and a coexistent reverse-phase interaction, etc.  相似文献   

19.
A novel multi-beam polarized photometric detector (PPD) for high-performance liquid chromatography (HPLC) is described. By pairing a polarizing prism with a thin quartz plate as a retarder, many linear polarized beams are produced at every 1/2 wavelength of the plate, and the polarizing axes of the adjacent beams intersect each other. The addition of another prism inclining its polarizing axis by π/4 against the first one enables the simultaneous measurement of optical rotations based on the PPD at many wavelengths. The combination of these optics with a photo-diode array detector can be used to construct a modulated type polarimeter. This detector is designed to measure the optical rotation of an analyte at its absorption band. The spline function connecting the points at 1/4 wavelengths of the plate was used as a baseline to extract the PPD waves. The use of the similarity factor as a noise filter gave high sensitivity. Application of the proposed technique to an analyte carrying the Cotton absorption band provided good results.  相似文献   

20.
Nepsilon-Monomethyllysine was identified in the serum, urine, brain, and liver samples of rats treated per os with L-deprenyl. The identification procedure included reaction with Fmoc chloride, clean-up, and analysis using HPLC-UV-MS. Oral administration of (-)-N-14C-methyl-N-propynyl(2-phenyl-1-methyl)ethylammonium hydrochloride L-deprenyl) to rats resulted in transfer of the radiolabelled methyl group to the Nepsilon-amino group of the endogenous lysine. The radiolabelled Nepsilon-monomethyllysine was urinary eliminated together with the other radiolabelled deprenyl metabolites, such as deprenyl-N-oxide and methamphetamine. The presence of Nepsilon-monomethyllysine has also been traced, and its concentrations were compared in the serum, liver and brain of rats subjected to L-deprenyl treatment. Methyl group transfer from the L-deprenyl to endogenous compounds; and the urinary elimination of their products may offer a vital way to eliminate or to decrease the degree of drug transmethylation to the lysine constituents of blood vessels' proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号