1.
Feng J  Yang XJ  Li XC  Yang H  Chen ZG 《Analytical sciences》2011,27(10):1057-1060
An automated fluid-transport device for a chip-based capillary electrophoresis system has been developed. The device mainly consists of six peristaltic micropumps, two vacuum micropumps, microvalves, multi-way joints, titanium tubes, and a macro-to-micro connector. Various solutions used for the cleaning and activation of chip channels, and electrophoresis separation, are allowed to automatically transport to chip reservoirs by the electric control module. The performance of the whole system was characterized by the analysis of fluorescein sodium using chip electrophoresis with LED-induced fluorescence detection. The peak-height variation (RSD) was 3.8% in six cycles of analyses. Additionally, compared with conventional manual operation, the developed device can spare 60% time for chip pretreatment. This microdevice offers high-efficiency pretreatment for microchips, thereby resulting in a remarkable improvement of analytical capacity for batch samples.  相似文献   

2.
3.
Duong CT  Roper MG 《The Analyst》2012,137(4):840-846
Free fatty acid (FFA) compositions are examined in feedstock for biodiesel production, as source-specific markers in soil, and because of their role in cellular signaling. However, sample preparation of FFAs for gas chromatography-mass spectrometry (GC-MS) analysis can be time and labor intensive. Therefore, to increase sample preparation throughput, a glass microfluidic device was developed to automate derivatization of FFAs to fatty acid methyl esters (FAMEs). FFAs were delivered to one input of the device and methanolic-HCl was delivered to a second input. FAME products were produced as the reagents traversed a 29 μL reaction channel held at 55 °C. A Design of Experiment protocol was used to determine the combination of derivatization time (T(der)) and ratio of methanolic-HCl:FFA (R(der)) that maximized the derivatization efficiencies of tridecanoic acid and stearic acid to their methyl ester forms. The combination of T(der) = 0.8 min and R(der) = 4.9 that produced optimal derivatization conditions for both FFAs within a 5 min total sample preparation time was determined. This combination of T(der) and R(der) was used to derivatize 12 FFAs with a range of derivatization efficiencies from 18% to 93% with efficiencies of 61% for tridecanoic acid and 84% for stearic acid. As compared to a conventional macroscale derivatization of FFA to FAME, the microfluidic device decreased the volume of methanolic-HCl and FFA by 20- and 1300-fold, respectively. The developed microfluidic device can be used for automated preparation of FAMEs to analyze the FFA compositions of volume-limited samples.  相似文献   

4.
This paper describes the design, fabrication, and test of a PDMS/PMMA-laminated microfluidic device for an immunosensing biochip. A poly(dimethyl siloxane)(PDMS) top substrate molded by polymer casting and a poly(methyl methacrylate)(PMMA) bottom substrate fabricated by hot embossing are bonded with pressure and hermetically sealed. Two inlet ports and an air vent are opened through the PDMS top substrate, while gold electrodes for electrochemical biosensing are patterned onto the PMMA bottom substrate. The analyte sample is loaded from the sample inlet port to the detection chamber by capillary force, without any external intervening forces. For this and to control the time duration of sample fluid in each compartment of the device, including the inlet port, diffusion barrier, reaction chamber, flow-delay neck, and detection chamber, the fluid conduit has been designed with various geometries of channel width, depth, and shape. Especially, the fluid path has been designed so that the sample flow naturally stops after filling the detection chamber to allow sufficient time for biochemical reaction and subsequent washing steps. As model immunosensing tests for the microfluidic device, functionalizations of ferritin and biotin to the sensing surfaces on gold electrodes and their biospecific interactions with antiferritin antiserum and streptavidin have been investigated. An electrochemical detection method for immunosensing by biocatalyzed precipitation has been developed and applied for signal registration. With the biochip, the whole immunosensing processes could be completed within 30 min.  相似文献   

5.
We demonstrate a micro-electroporation device for cell lysis prior to subcellular analysis. Simple circuit models show that electrical lysis method is advantageous because it is selective towards plasma membrane while leaving organelle membrane undamaged. In addition, miniaturization of this concept leads to negligible heat generation and bubble formation. The designed microdevices were fabricated using a combination of photolithography, metal-film deposition, and electroplating. We demonstrate the electro-lysis of human carcinoma cells in these devices to release the subcellular materials.  相似文献   

6.
Dutta D  Ramsey JM 《Lab on a chip》2011,11(18):3081-3088
Microchannels in microfluidic devices are frequently chemically modified to introduce specific functional elements or operational modalities. In this work, we describe a miniaturized hydraulic pump created by coating selective channels in a glass microfluidic manifold with a polyelectrolyte multilayer (PEM) that alters the surface charge of the substrate. Pressure-driven flow is generated due to a mismatch in the electroosmotic flow (EOF) rates induced upon the application of an electric field to a tee channel junction that has one arm coated with a positively charged PEM and the other arm left uncoated in its native state. In this design, the channels that generate the hydraulic pressure are interconnected via the third arm of the tee to a field-free analysis channel for performing pressure-driven separations. We have also shown that modifications in the cross-sectional area of the channels in the pumping unit can enhance the hydrodynamic flow through the separation section of the manifold. The integrated device has been demonstrated by separating Coumarin dyes in the field-free analysis channel using open-channel liquid chromatography under pressure-driven flow conditions.  相似文献   

7.
The primary requirement for a mixing operation in droplet-based microfluidic devices is an accurate pairing of droplets of reaction fluids over an extended period of time. In this paper, a novel device for self-synchronous production of droplets has been demonstrated. The device uses a change in impedance across a pair of electrodes introduced due to the passage of a pre-formed droplet to generate a second droplet at a second pair of electrodes. The device was characterised using image analysis. Droplets with a volume of ~23.5 ± 3.1 nl (i.e.~93% of the volume of pre-formed droplets) were produced on applying a voltage of 500 V. The synchronisation efficiency of the device was 83%. As the device enables self-synchronised production of droplets, it has a potential to increase the reliability and robustness of mixing operations in droplet-based microfluidic devices.  相似文献   

8.
Zheng Y  Zhao S  Liu YM 《The Analyst》2011,136(14):2890-2892
Highly active horseradish peroxidase functionalized magnetic nanoparticles were prepared and packed into a microfluidic channel, producing an in-line bioreactor that enabled a sensitive chemiluminescence assay of H(2)O(2). The proposed magnetically active microfluidic device proved useful for chemiluminescence assays of biomedically interesting compounds.  相似文献   

9.
This device is aimed at ensuring that the sample is uniformly and equivalently reacted with the antibody on the NC membrane in each test when the microfluidic liquid system is introduced to the chip. In this study, the developed microfluidic chip can avoid the presence of the sample and conjugate pads in the chip, while the precision of the chromatography system can be greatly improved using the same particles, NC membrane and antibody alongside the traditional strip. The results, taking the detection of cTnI as an example, revealed that the coefficient of variation (CV) is controlled within 4%, while the maximum record of the contrast chromatographic reagent strip can reach 15%. Additionally, the detection sensitivity can maintain the same order of magnitudes with that of the traditional chromatographic strip. With the results, the determination correlation of the developed microfluidic chip has been greatly improved. In addition, the CV of the chip in this study is greatly improved in comparison with that of the traditional strip. The biggest improvement lies in the mixing between the sample and the microspheres, indicating that this is a new approach to improve the CV of the traditional strip.  相似文献   

10.
A two-layer polymer microfluidic device is presented which creates nine linear dilutions from two input fluid streams mixed in varying volumetric proportions. The linearity of the nine dilutions is conserved when the flow rate is held constant at 1.0 microl min(-1) (R(2) = 0.9995) and when it is varied from 0.5-16 microl min(-1) (R(2) = 0.9998). An analytical expression is presented for designing microfluidic devices with arbitrary numbers of linear dilutions. To demonstrate the efficacy of this device, primary human epidermal keratinocytes (HEK) were stained with nine dilutions of calcein, resulting in a linear spread of fluorescent intensities (R(2) = 0.94). The operating principles of the device can be scaled up to incorporate any number of linear dilutions. This scalability, coupled with an intrinsic ability to create linear dilutions under a variety of operating conditions, makes the device applicable to high throughput screening applications such as combinatorial chemistry or cytotoxicity assays.  相似文献   

11.
A passive microfluidic device is reported for continuous microparticle enrichment. The microparticle is enriched based on the inertial effect in a microchannel with contracting‐expanding structures on one side where microparticles/cells are subjected to the inertial lift force and the momentum‐change‐induced inertial force induced by highly curved streamlines. Under the combined effect of the two forces, yeast cells and microparticles of different sizes were continuously focused in the present device over a range of Reynolds numbers from 16.7 to 125. ~68% of the particle‐free liquid was separated from the sample at Re = 66.7, and ~18 μL particle‐free liquid was fast obtained within 10 s. Results also showed that the geometry of the contracting‐expanding structure significantly influenced the lateral migration of the particle. Structures with a large angle induced strong inertial effect and weak disturbance effect of vortex on the particle, both of which enhanced the microparticle enrichment in microchannel. With simple structure, small footprint (18 × 0.35 mm), easy operation and cell‐friendly property, the present device has great potential in biomedical applications, such as the enrichment of cells and the fast extraction of plasma from blood for disease diagnose and therapy.  相似文献   

12.
Chip-to-world interface is a major issue in the field of microfluidics and its applications. We developed a plug and play microfluidic device composed of a fluid driving unit and a polymer chip containing microfluidic channels and reservoirs. The one and only connection of the device to the external world is a set of electric control lines for the driving unit. Just putting the reagents and samples onto the reservoirs, the chip can be operated for chemical or biochemical reaction and analysis. We demonstrate here that silicon-based micropumps embedded in the present device allow us to achieve flexible fluidic manipulations with minimum time delay and dead volume.  相似文献   

13.
Si G  Yang W  Bi S  Luo C  Ouyang Q 《Lab on a chip》2012,12(7):1389-1394
We developed a multiple-channel microfluidic device for bacterial chemotaxis detection. Some characteristics such as easy operation, parallel sample adding design and fast result readout make this device convenient for most biology labs. The characteristic feature of the design is the agarose gel channels, which serve as a semi-permeable membrane. They can stop the fluid flow and prevent bacteria getting across, but permit the diffusion of small molecules. In the device fabrication process a novel thermal-based method was used to control the shape of agarose gel in the microfluidic channel. The chemical gradient is established by diffusion which can be precisely controlled and measured. Combined with an 8-channel pipette, different attractants, repellent chemicals or different bacteria were analyzed by a two step operation with a readout time of one hour. This device may be useful in the high throughput detection of chemotaxis related molecules and genes.  相似文献   

14.
We describe an electrochemiluminescence (ECL) immunoarray incorporated into a prototype microfluidic device for highly sensitive protein detection and apply this system to accurate, sensitive measurements of prostate-specific antigen (PSA) and interleukin-6 (IL-6) in serum. The microfluidic system employed three molded polydimethylsiloxane (PDMS) channels on a conductive pyrolytic graphite chip (2.5?×?2.5 cm) inserted into a machined chamber and interfaced with a pump, switching valve, and sample injector. Each of the three PDMS channels encompasses three 3 μL analytical wells. Capture-antibody-decorated single-wall carbon nanotube forests are fabricated in the bottom of the wells. The antigen is captured by these antibodies on the well bottoms. Then, a RuBPY-silica-secondary antibody (Ab2) label is injected to bind to antigen on the array, followed by injection of sacrificial reductant tripropylamine (TPrA) to produce ECL. For detection, the chip is placed into an open-top ECL measuring cell, and the channels are in contact with electrolyte in the chamber. Potential applied at 0.95 V versus Ag/AgCl oxidizes TPrA to produce ECL by redox cycling the RuBPY species in the particles, and ECL light is measured by a charge-coupled device camera. This approach achieved ultralow detection limits of 100 fg?mL?1 for PSA (9 zeptomole) and 10 fg?mL?1 (1 zeptomole) for IL-6 in calf serum, a 10–25-fold improvement of a similar non-microfluidic array. PSA and IL-6 in synthetic cancer patient serum samples were detected in 1.1 h and results correlated well with single-protein enzyme-linked immunosorbent assays.  相似文献   

15.
Kim J  Hegde M  Kim SH  Wood TK  Jayaraman A 《Lab on a chip》2012,12(6):1157-1163
Bacteria are almost always found in ecological niches as matrix-encased, surface-associated, multi-species communities known as biofilms. It is well established that soluble chemical signals produced by the bacteria influence the organization and structure of the biofilm; therefore, there is significant interest in understanding how different chemical signals are coordinately utilized for community development. Conventional methods for investigating biofilm formation such as macro-scale flow cells are low-throughput, require large volumes, and do not allow spatial and temporal control of biofilm community formation. Here, we describe the development of a PDMS-based two-layer microfluidic flow cell (μFC) device for investigating bacterial biofilm formation and organization in response to different concentrations of soluble signals. The μFC device contains eight separate microchambers for cultivating biofilms exposed to eight different concentrations of signals through a single diffusive mixing-based concentration gradient generator. The presence of pneumatic valves and a separate cell seeding port that is independent from gradient-mixing channels offers complete isolation of the biofilm microchamber from the gradient mixer, and also performs well under continuous, batch or semi-batch conditions. We demonstrate the utility of the μFC by studying the effect of different concentrations of indole-like biofilm signals (7-hydroxyindole and isatin), either individually or in combination, on biofilm development of pathogenic E. coli. This model can be used for developing a fundamental understanding of events leading to bacterial attachment to surfaces that are important in infections and chemicals that influence the biofilm formation or inhibition.  相似文献   

16.
Xu J  Ahn B  Lee H  Xu L  Lee K  Panchapakesan R  Oh KW 《Lab on a chip》2012,12(4):725-730
We present a multiple-droplet clustering device that can perform sequential droplet trapping and storing. Shape-dependent droplet manipulation in forward and backward flows has been incorporated to achieve high trapping and storing efficiency in a 10 × 12 array of clustering structures (e.g., storing well, storing chamber, trapping well, and guiding track). In the forward flow, flattened droplets are trapped in each trapping well. In the backward flow, the trapped droplets are released from the trapping well and follow the guiding tracks to their corresponding storing wells. The guided droplets float up out of the confining channel to the super stratum of the storing chamber due to interfacial energy and buoyancy effects. This forward/backward flow-based trapping/storing process can be repeated several times to cluster droplets with different contents and samples in the storing chambers. We expect that the proposed platform will be a valuable tool to study complex droplet-based reactions in clustered droplets.  相似文献   

17.
Screen-printed microfluidic device for electrochemical immunoassay   总被引:2,自引:0,他引:2  
Dong H  Li CM  Zhang YF  Cao XD  Gan Y 《Lab on a chip》2007,7(12):1752-1758
In this paper, a new microfluidic array device has been fabricated with screen printing technology. In contrast to traditional microfabrication processes, our method is simple, inexpensive and also suitable for mass production. The device is used for sandwich-type electrochemical immunoassay, in which probes are covalently attached to the electrode surface via electropolymerized polypyrrole propylic acid (PPA) film. This novel microfluidic system enables the whole array preparation and detection processes, including the probe immobilization, sample injection, enzyme incubation and electrochemical detection, to be conducted in the sealed microchannels. For a demonstration, mouse IgG is selected as the target analyte and its detection is realized by sandwich ELISA with goat anti-mouse IgG, rat anti-mouse IgG (conjugated to alkaline phosphatase) and p-aminophenyl phosphate (PAPP) as the primary antibody, second antibody, and enzyme substrate, respectively. A detection limit of 10 ng mL(-1) (67 pM) is achieved with a dynamic range of 100 ng mL(-1)-10 microg mL(-1). In addition, anti-goat IgG is also immobilized as an alternative probe to test mouse IgG in the solution, in order to demonstrate the multiplexing capability as well as the specificity of the device. As expected, the electrochemical responses are much lower than that using anti-mouse IgG as the probe, indicating good selectivity of the immunoassay device. These results indicate a great promise toward the development of miniaturized, low-cost protein biochips for clinical, forensics, environmental, and pharmaceutical applications.  相似文献   

18.
Hu N  Yang J  Yin ZQ  Ai Y  Qian S  Svir IB  Xia B  Yan JW  Hou WS  Zheng XL 《Electrophoresis》2011,32(18):2488-2495
A high-throughput cell electrofusion microfluidic chip has been designed, fabricated on a silicon-on-insulator wafer and tested for in vitro cell fusion under a low applied voltage. The developed chip consists of six individual straight microchannels with a 40-μm thickness conductive highly doped Si layer as the microchannel wall. In each microchannel, there are 75 pairs of counter protruding microelectrodes, between which the cell electrofusion is performed. The entire highly doped Si layer is covered by a 2-μm thickness aluminum film to maintain a consistent electric field between different protruding microelectrode pairs. A 150-nm thickness SiO? film is subsequently deposited on the top face of each protruding microelectrode for better biocompatibility. Owing to the short distance between two counter protruding microelectrodes, a high electric field can be generated for cell electrofusion with a low voltage imposed across the electrodes. Both mammalian cells and plant protoplasts were used to test the cell electrofusion. About 42-68% cells were aligned to form cell-cell pairs by the dielectrophoretic force. After cell alignment, cell pairs were fused to form hybrid cells under the control of cell electroporation and electrofusion signals. The averaged fusion efficiency in the paired cells is above 40% (the highest was about 60%), which is much higher than the traditional polyethylene glycol method (<5%) and traditional electrofusion methods (~12%). An individual cell electrofusion process could be completed within 10 min, indicating a capability of high throughput.  相似文献   

19.
A microfluidic device is presented that performs electrophoretic separation coupled with fraction collection. Effluent from the 3.5 cm separation channel was focused via two sheath flow channels into one of seven collection channels. By holding the collection channels at ground potential and varying the voltage ratio at the two sheath flow channels, the separation effluent was directed to either specific collection channels, or could be swept past all channels in a defined time period. As the sum of the voltages applied to the two sheath flow channels was constant, the electric field remained at 275 V/cm during the separation regardless of the collection channel used. The constant potential in the separation channel allowed uninterrupted separation for late-migrating peaks while early-migrating peaks were being collected. To minimize the potential for carryover between fractions, the device geometry was optimized using a three-level factorial model. The optimum conditions were a 22.5° angle between the sheath flow channels and the separation channel, and a 350 μm length of channel between the separation outlet and the fraction channels. Using these optimized dimensions, the device performance was evaluated by separation and fraction collection of a fluorescently labeled amino acid mixture. The ability to fraction collect on a microfluidic platform will be especially useful during automated or continuous operation of these devices or to collect precious samples.  相似文献   

20.
Aberrant glycosylation plays a pivotal role in a diverse set of diseases, including cancer. A microfluidic lectin blotting platform is introduced to enable and expedite the identification of protein glycosylation based on protein size and affinity for specific lectins. The integrated multistage assay eliminates manual intervention steps required for slab-gel lectin blotting, increases total assay throughput, limits reagent and sample consumption, and is completed using one instrument. The assay comprises non-reducing sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) followed by online post-sizing SDS filtration and lectin-based affinity blotting. Important functionality is conferred through both device and assay advances that enable integration of nanoporous membranes flanking a central microchamber to create sub-nanoliter volume compartments that trap SDS-protein complexes and allow electrophoretic SDS removal with buffer exchange. Recapitulation of protein binding for lectin was optimized through quantitative assessment of SDS-treated green fluorescent protein. Immunoglobulin A1 aberrantly glycosylated with galactose-deficient O-glycans was probed in ~6 min using ~3 μL of sample. This new microfluidic lectin blotting platform provides a rapid and automated assay for the assessment of aberrant glycosylation.  相似文献   