首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Liquid chromatography with atmospheric pressure chemical ionisation mass spectrometry (LC/APCI-MS), using negative ion detection in a triple quadrupole instrument, was used for the determination of chlorophenols (CPs) in environmental samples. In-source collision-induced dissociation (CID) was compared with MS/MS fragmentation. In general, less fragmentation was observed in MS/MS as compared with in-source CID, with the latter providing more intense fragment ions due to chemical ionisation. Under MS/MS conditions [M - H - HCl](-) was the main fragment ion observed for all compounds except for pentachlorophenol, which showed no fragmentation. For multiple reaction monitoring (MRM) acquisition mode, the transition from [M - H](-) to [M - H - HCl](-) was selected, leading to detection limits down to 0.3 ng injected. Direct and headspace-solid-phase microextraction (HS-SPME) were used as preconcentration procedures for the analysis of CPs in wood and in industrially contaminated soils. CPs were quantified by standard addition, which led to good reproducibility (RSD between 4 and 11%) in both SIM and MRM modes, and detection limits down to ng/g. The combination of MS/MS and in-source CID allowed confirmation of the presence of CPs in environmental samples.  相似文献   

2.
3.
A methodology for the simultaneous analysis of eight polybrominated diphenyl ethers (PBDEs); eight methoxylated PBDEs (MeO-PBDEs); and three emerging flame retardants, hexabromobenzene (HBB), pentabromoethyl benzene (PBEB), and decabromodiphenyl ethane (DBDPE) by gas chromatography coupled to tandem mass spectrometry (GC-MS-MS) was developed for two environmental matrices (sediment and sludge) and three biological matrices (fish, dolphin blubber, and bird eggs). The use of selective reaction monitoring (SRM) allows a high selectivity, which is critical in the analysis of complex samples like blubber. Analytical parameters such as linearity, reproducibility, or accuracy were evaluated. Method limits of detection and quantification were evaluated and compared with GC-EI-MS and GC-NCI-MS. Method detection limits were valid for the environmental analysis in all cases, with values between 0.01 and 1.65 ng/g dw for sediment, 0.05 and 2.78 ng/g dw for sludge, 0.04 and 10.6 ng/g lw for fish, 0.01 and 1.11 ng/g lw for dolphin blubber, and 0.03 and 3.20 ng/g lw for bird eggs. The developed method was applied to five samples of each matrix. PBDEs were detected in all samples, while MeO-PBDEs were only detected in dolphin blubber. DBDPE was detected in sediment and sludge.  相似文献   

4.
An analytical method for screening, quantitation and confirmation of a group of 100 pesticides in vegetable and fruit samples was developed using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS). The pesticides studied belonged to different chemical families of herbicides, insecticides and fungicides; some degradation products were included as well. A thorough optimization was performed for each analyte to achieve individual optimum fragmentor and collision energy voltages. Two transitions per parent compound were monitored in a single chromatographic run containing two time segments. A small particle size C(18) column (1.8 microm) was used for the chromatographic separation of the mixture, providing very narrow peaks and allowing an excellent separation of all the analytes in a 30-min period for maximum peak capacity. The method was validated with blank matrices of green pepper, tomato and orange spiked from 0.1 to 100 microg/kg with the pesticide mix. Quantitation was carried out using matrix-matched standard calibration and linearity of response over 3 orders of magnitude was demonstrated (r > 0.99). Limits of detection based on two transitions and ion-ratio requirements ranged between 0.3 and 50 microg/kg. In general, the sensitivity obtained meets the maximum residue levels (MRLs) established by the European Union regulation for food monitoring programs. The analytical performance of the method was evaluated for different types of vegetables and fruits, showing little or no matrix effects, and examples of screening and confirmation of pesticides in these samples are shown here.  相似文献   

5.
A number of compounds belonging to five chemical classes of aromatic amines were identified by electron impact mass spectrometry, both in the vapor phase and in suspended particulate matter collected in an area subjected to heavy traffic. This paper presents the mass spectra of new aromatic amines, proposed mechanisms for formation of the major ions obtained by electron impact, concentrations of each class in 13 environmental samples, and the distribution of the individual compounds of the major chemical classes (greater than 80% by weight).  相似文献   

6.
A headspace solid-phase microextraction gas chromatography coupled with tandem mass spectrometry (HSSPME-GC-MS-MS) methodology for determination of brominated flame retardants in sediment and soil samples is presented. To the best of our knowledge, this is the first time that SPME has been applied to analyze polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in environmental solid samples. Analyses were performed using 0.5-g solid samples moisturized with 2 mL water, employing a polydimethylsiloxane (PDMS) fiber coating, exposed to the headspace at 100 °C for 60 min. Several types of environmental solid samples were included in this study and the extraction efficiency was related to the organic matter content of the sample. Calibration was performed using real samples, and the method showed good linearity over a wide concentration range, precision, and afforded quantitative recoveries. The obtained detection limits were in the sub-ng g−1 for all the target analytes in both samples. The proposed procedure was applied to several marine and river sediments and soils, some of which were found to contain PBDEs at concentrations in the ng g−1 level; BDE-47, BDE-100, and BDE-99 were the major congeners detected. The proposed method constitutes a rapid and low-cost alternative for the analysis of the target brominated flame retardants in environmental solid samples, since the clean-up steps, fractionation, and preconcentration of extracts inherent to the classical multi-step solvent extraction procedures are avoided.   相似文献   

7.
We report the linear retention indices of the 14 methylnitro-naphthalenes on three high resolution capillary columns and their electron impact mass spectra. The analyses of the methylnitro-naphthalenes in an ambient air sample by gas chromatography/mass spectrometry with multiple ion detection utilizing 5% phenylmethylsilicone, 50% phenylmethylsilicone, and smectic columns are shown.  相似文献   

8.
Summary Turbulent flow chromatography coupled to tandem mass spectrometry (TFC-MS-MS) has recently emerged as a potentially fast, sensitive and specific technique for the direct analysis of pharmaceutical compounds from crude plasma. TFC-MS-MS removes the need for time-consuming sample preparation procedures such as solid-phase extraction (SPE) or liquid-liquid extraction (LLE). A relatively high flow rate combined with the use, of an HPLC column with large porous particles allows the on-line clean up and quantification of compounds in plasma samples. Until, now, the amount of plasma directly injected into TFC systems has rarely exceeded 30 μL in order to prevent rapid column degradation. Increasing the injection volume also induces high carry-over levels, particularly for drugs with basic and/or lipophilic properties. This paper describes the first genetic TFC-MS-MS method developed in a 96-well format, which allows the direct injection of 200 μL of 1∶1 diluted plasma (equivalent to 100 μL neat plasma). An average, of 390 injections was carried out with each extraction column. More than 2000 dog plasma samples were injected into the system without any sign of carryover. The method was fully validated over a 5–500 ng mL−1 range for three basic compounds: doxazosin, CP122,288 and dofetilide. The imprecision was 1.2 to 8.3% for doxazosin, 1.5 to 4% for CP122,288 and 1.6 to 9.2% for dofetilide. The inaccuracy ranged from 6% to 7.9%. This generic methodology was then used to assay two structurally unrelated development compounds, showing that the method accuracy and sensitivity were adequate for the early pharmacokinetic (PK) studies in animals.  相似文献   

9.
The explosive triacetone triperoxide (TATP) has been analyzed by gas chromatography/mass spectrometry (GC/MS) and sub-nanogram detection limits are reported by ammonia positive ion chemical ionization (PICI), electron ionization (EI) and methane negative ion chemical ionization (NICI). Analysis by methane PICI and ammonia NICI gave detection limits in the low nanogram range. Analyses were carried out on (linear) quadrupole and ion trap instruments. Analysis of TATP by PICI using ammonia reagent gas is the preferred analytical method, producing low limits of detection as well as an abundant (greater than 60% of base peak) diagnostic adduct ion at m/z 240 corresponding to [TATP + NH4]+. Isolation of the [TATP + NH4]+ ion with subsequent collision-induced dissociation (CID) produces extremely low abundance product ions at m/z values greater than 60, and the m/z 223 ion corresponding to [TATP + H]+ was not observed. Density functional theory (DFT) calculations at the B88LYP/DVZP level indicate that dissociation of the complex to form NH4+ and TATP occurs at energies lower than peroxide bond dissociation, while protonation of TATP leads to cleavage of the ring structure. These results provide a method for pico-gram detection levels of TATP using commercial instrumentation commonly available in forensic laboratories. As a point of comparison, a detection limit of 15 ng was obtained by flame ionization detection.  相似文献   

10.
Two fibre-optic interfaces were constructed for laser photodissociation/tandem mass spectrometry using an ion trap spectrometer. These interfaces allow sample introduction from a liquid reservoir, solids probe and gas chromatograph. The laser/ion trap configuration was applied to the analysis of a mixture of alkylbenenes separated by gas chromatography using 573 nm photons.  相似文献   

11.
12.
13.
An accurate method for the quantification of carboxymethyllysine (CML) in food samples is evaluated. CML, a stable advanced Maillard compound, is considered as an useful marker of protein damage in severely heated foods. The proposed GC-MS method stipulates double derivatisation of amino acids and quantification by selected ion monitoring. Relative error of repeatability was further improved from 5 to 1% by replacing internal standard by isotope dilution. Comparison with enzyme linked immunosorbent assay (ELISA) was performed on infant formulas, with satisfactory results in powdered but not in liquid formulas. Quantification of CML in several food matrices allowed evidencing CML formation in food products containing reducing sugar only.  相似文献   

14.
The determination of tetra- to octachlorodibenzo-p-dioxins and tetra- to octachlorodibenzofurans (PCCD/Fs) by high-resolution gas chromatography/tandem mass spectrometry (HRGC/MS/MS) and high-resolution gas chromatography/triple mass spectrometry (HRGC/MS(3)) in a quadrupole ion trap, equipped with an external ion source, is presented. MS/MS involves a typical four-step process, namely ionization, parent ion isolation, collision-induced dissociation (CID) and mass analysis of the daughter ions. For the MS(3) experiment, the MS/MS scan function is used with the addition of selected daughter ion isolation, their CID and the mass analysis of second-generation product ions called 'grand-daughter ions.' For both methods, the energies necessary for the CID of the 17 PCDD/Fs were determined and optimized using multiple scan functions with different CID amplitudes. The CID efficiency, defined as the signal ratio of fragment ions detected from the major dissociation channels to molecular ions isolated, was 1.15-2.40 V for parent ion dissociation (MS/MS) and 1.05-1.50 V for daughter ion dissociation (MS(3)) and for all the chloro congeners. The same sensitivity (1 pg microl(-1)) can be reached with both the MS/MS and MS(3) methods and linear responses were obtained between 1 and 100 pg microl(-1) injected.  相似文献   

15.
Due to safety concerns regarding dietary exposure to POPs, regulatory bodies are issuing detailed guidelines for testing for polychlorodibenzodioxins (PCDDs) and polychlorodibenzofurans (PCDFs) ('dioxins') and dioxin‐like (DL)‐PCBs in foods of animal origin. Determination of the aforesaid chemicals at regulatory levels requires highly selective and sensitive testing techniques. The new generation of low‐resolution mass spectrometers (triple quadrupoles) allows very low levels of quantification to be reached (in the order of tens of femtograms), thus suggesting a potential for their application in food and feed analysis. The performance of the low‐resolution tandem mass spectrometry (LRMS/MS) approach with triple quadrupoles was assessed on a qualified set of food samples from proficiency tests (PTs) and defense analysis. Accuracy was tested comparing the results with data from high‐resolution mass spectrometry (HRMS) and with consensus values from PTs. The cumulative TEQ results were characterized by deviations not exceeding 15% of PCDD + PCDF, DL‐PCB, and PCDD + PCDF + DL‐PCB (TEQTOT) reference consensus values (sample TEQTOT range, 2.29–25.1 pgWHO‐TEQ97/g fat). Congener analytical variabilities did not influence significantly the WHO‐TEQ97 outcome of the corresponding sample. This preliminary performance evaluation highlights the potential of LRMS/MS as a routine technique for quantitative analysis of PCDDs, PCDFs, and DL‐PCBs in food. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
A new method for the analysis of three ecological insecticides, namely azadyrachtin, spinosad (sum of spinosyn A and spinosyn D) and rotenone, in produce and soil samples is presented. Investigated compounds are one of the most significant insecticides authorized for organic farming crop protection in many countries. Extraction of the pesticides from plant and soil matrices was performed by using a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. The method entailed a single extraction of the investigated compounds with acidified acetonitrile followed by a dispersive solid-phase extraction cleanup step prior to the final determination by reverse-phase ultra-performance liquid chromatography/tandem quadrupole mass spectrometry (UPLC-MS/MS). Validation studies were carried out on cabbage, tomato and soil samples. Recoveries of the spiked samples were in the range between 67% and 108%, depending on the matrix and the spiking level. Relative standard deviations for all matrix–compound combinations did not exceed 12%. The limits of quantification were ≤0.01 mg kg−1 in all cases, except for azadirachtin. The developed method was applied to the analysis of real samples originating from organic farming production.  相似文献   

17.
18.
A simple, rapid and sensitive method is described for the determination of omethoate, dimethoate, diazinon, chlorpyrifos, parathion‐ethyl, chlorfenvinphos, quinalphos and azinphos‐ethyl in postmortem whole blood samples. The analytes and internal standard (ethion) were isolated from the matrix by solid‐phase extraction, and were analysed by gas chromatography/mass spectrometry in the selected ion monitoring mode. The method has shown to be selective after analysis of postmortem samples of 40 different origins. Calibration curves were established between 0.05 (0.1 for omethoate) and 25 µg/mL, and the values obtained for intra‐ and interday precision and accuracy were within the criteria usually accepted for bioanalytical method validation. Lower limits of quantitation were 50 ng/mL for all compounds, except for omethoate (100 ng/mL); the limits of identification of the method were 25 ng/mL for all analytes, except for omethoate, for which 50 ng/mL was obtained. Absolute recovery was determined at three concentration levels, and ranged from 31 to 108%. The proposed method is simple and fast, and can be routinely applied in the determination of these compounds in postmortem whole blood samples within the scope of forensic toxicology. In addition, mass spectrometry has demonstrated to be a powerful and indispensable tool for the unequivocal identification of the analytes, since the acceptance criteria were accomplished even at very low levels, thus allowing obtaining forensically valid and sound results. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
In this work, two analytical methods based on liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC/ESI-TOFMS) and tandem mass spectrometry (LC/ESI-MS/MS) are described for the identification, confirmation and quantitation of three insecticides non-authorized in the European Union (nitenpyram, isocarbophos and isofenphos-methyl) but detected in recent monitoring programmes in pepper samples. The proposed methodologies involved a sample extraction procedure using liquid-liquid partition with acetonitrile followed by a cleanup step based on dispersive solid-phase extraction. Recovery studies performed on peppers spiked at different fortification levels (10 and 50 microg kg(-1)) yielded average recoveries in the range 76-100% with relative standard deviation (RSD) (%) values below 10%. Identification, confirmation and quantitation were carried out by LC/TOFMS and LC/MS/MS using a hybrid triple quadrupole linear ion trap (QqLIT) instrument in multiple-reaction monitoring (MRM) mode. The obtained limits of quantitation (LOQs) were in the range 0.1-5 microg kg(-1), depending on each individual technique. Finally, the proposed methods were successfully applied to the analysis of suspected pepper samples.  相似文献   

20.
A multiresidue method for the determination of more than 80 pesticides in water has been developed and validated. The proposed method is based on SPE followed by GC coupled to MS/MS. Different variables affecting SPE procedure, such as cartridges, sample volume and solvents were studied, and mass spectrometric conditions were optimised in order to increase selectivity and sensitivity. Calibration curves were linear over the range of 0.03-0.5 microg/L. Recoveries were in the range of 70-110% and repeatability was below 20% for the lowest calibration point. LODs ranged from 0.001 to 0.025 microg/L and LOQs from 0.003 to 0.076 microg/L. Finally, the method was successfully applied to the analysis of water samples from southeast of Spain.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号