首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
Ultra-fast magnetic resonance imaging techniques are used to image liquid distribution in two and three dimensions during air-water co-current down flow through a fixed bed of cylindrical porous pellets of length and diameter 3 mm, packed within a 43 mm internal diameter column in both the trickle- and pulsing-flow regimes. The data acquisition times used were 20 and 280 ms, giving 2-D and 3-D spatial resolutions of 1.4 mm x 2.8 mm and 3.75 mm x 3.75 mm x 1.87 mm, respectively. This work reports images of local pulsing events within the bed occurring during the trickle-to-pulse flow transition. The evolution of the local instabilities is studied as a function of increasing liquid velocity at constant gas velocity.  相似文献   

2.
Localized holographic recording in doubly doped lithium niobate   总被引:1,自引:0,他引:1  
Persistent holograms are recorded locally with red light in a LiNbO>(3) crystal doped with Mg and Fe. Selective erasure is realized by use of a focused UV sensitizing light. We demonstrate the recording of 50 localized images as well as selective erasure in a 4 mm x 4 mm x 4 mm crystal. A comparison of the total recording time for M holograms obtained with the conventional distributed-volume recording and the localized methods is presented.  相似文献   

3.
Er3+/Yb3+:KG(WO4)2的熔盐提拉法生长及光谱性能   总被引:2,自引:0,他引:2  
采用熔盐提拉法生长了尺寸达30 mm×25 mm×15 mm的Er3+/yb3+KGd(WO4)2透明晶体,从中切出5 mm×5 mm×3mm大小的激光器件,在室温下测试了吸收光谱,可以观察到晶体存在366,380,489,522,651,811,980 nm等吸收峰,并对之进行了能级归属.同时在980 nm激光激发下测试了荧光光谱,可以发现在1 024,1 535 nm处存在较宽的强发射峰,其半高宽分别为60和36 nm.研究结果表明,Er3+/yb3+KG(WO4)2适合于InGaAs LD(980 nm)泵浦,有可能产生1 024 nm波段及人眼安全的1 535 nm波段的可调谐激光.  相似文献   

4.
Methods for examinations of diffusion of large molecules of the size of fatty acids or triglycerides were developed for whole body MR units. Samples of aliphatic molecules were examined to study the influence of chain length. Feasibility under in vivo conditions was tested on lard samples at 37 degrees C and on human subjects Three stimulated echo sequences with maximum b-values of 2000 s/mm(2), 20000 s/mm(2), and 80000 s/mm(2) were used to assess a wide range of mobility. Sequence timing was optimized to minimize relaxation losses of fatty tissue. Apparent diffusion coefficients (ADC) were determined from five spectra with different diffusion weighting. In-vitro experiments were performed on butanol, decanol, and oleic acid to study the influence of chain length. In vivo conditions were mimicked using lard at 37 degrees C representing a composition of substances of various chain lengths. Subcutaneous fat and tibial bone marrow were studied in three healthy volunteers. ADC of muscular lipids of the lower leg was determined in two subjects. ADC values of pure aliphatic substances were in the range between 3.2 x 10(-5) mm(2)/s for oleic acid and 37.8 x 10(-5) mm(2)/s for butanol. In vivo investigations revealed ADC values of 1.11-1.24 x 10(-5) mm(2)/s for tibial bone marrow and 1.21-2.05 x 10(-5) mm(2)/s for subcutaneous fat. Diffusion coefficients of extra- and intramyocellular lipids were 1.83-3.65 x 10(-5) mm(2)/s and 2.22-3.60 x 10(-5) mm(2)/s, respectively. The proposed technique enables determination of ADC values of relatively large molecules and of lipid tissue compartments under in vivo conditions. Diffusion properties in several human lipid compartments are reported for the first time. Incoherent voxel motion influences the in vivo results to an unknown degree because of high motion sensitivity. In vitro experiments revealed ADC values depending on the chain length of the substances, indicating a residual dependence of measured ADC's on sequence timing.  相似文献   

5.
Linear arrays of damped multistable systems in a constant driving fieldF are considered in the tight coupling limit. The existence of a localized relaxation mode (inertia mode) of the driven kinks is pointed out. This mode, whose frequency on the time scale of theL-system is a universal (model independent) quantity, describes the accomodation of the kink to a new shape and terminal velocity when the driving field is changed infinitestimally. In a chain without inertia the accommodation is instantaneous. Whence the name inertia mode (IM). The IM is generated by the translation invariance of the kink equation, in addition to the Goldstone mode (GM). In the absence of the driving force and dissipation, the IM becomes defectively degenerate with the GM and represents a pure algebraic mode of the free kink, describing another free kink moving with infinitesimally changed velocity.Work supported by the Swiss National Science Foundation.  相似文献   

6.
Modifications of the pulse sequence for spectroscopic U-FLARE imaging are discussed to detect not only the predominant singlet signals of N-acetylaspartate, total creatine, and choline containing compounds or the doublet signal of lactate, but also the coupled resonances of glutamate, glutamine, taurine and myo-inositol. Effective homonuclear decoupling is achieved by use of constant time chemical shift encoding. A maximum signal-to-noise ratio (SNR) can be obtained for a certain coupled resonance of interest by optimizing the evolution period t(c) of the J modulated spin echo. Good reproducibility and a high SNR were achieved by combining several methods for water suppression and by using the displaced variant of U-FLARE. Measurements of a 3 mm slice of the rat brain were performed in vivo within 4 min, giving a nominal voxel size of 1.5 x 1.5 x 3.0 mm3 or 1.5 x 0.75 x 3.0 mm3. Thus, optimized spectroscopic U-FLARE is a powerful tool for proton spectroscopic imaging with high spectral, spatial and temporal resolution.  相似文献   

7.
Very thin and small (45 mm x 35 mm x 0.35 mm) piezoelectric radiators have been developed in this research. The system is modeled by using the energy method in conjunction with the assumed-modes method. Electrical system, mechanical system, and acoustic loading have all been accounted for during the modeling stage. On the basis of the simulation model, the genetic algorithm (GA) is employed to optimize the overall configurations for a low resonance frequency and a large gain. The resulting designs are then implemented and evaluated experimentally. Performance indices for the experimental evaluation include the frequency response, the directional response, the sensitivity, and the efficiency. It is found in the experimental results that the piezoelectric radiators are able to produce comparable acoustical output with significantly less electrical input than the voice-coil panel speakers.  相似文献   

8.
A measure of the sharpness of vessel wall interfaces in carotid artery MRI may be useful for assessing the conspicuity of the wall's features. An edge detection technique was used to measure the signal intensity gradients in 2D time-of-flight (2D-TOF) and double-inversion recovery black-blood (DIR-BB) carotid artery images of normal subjects that were acquired at 1.5 T with 0.55 x 0.55 x 2.0-mm (0.6 mm3) acquisition voxels and zero filled to reduce the in-plane reconstructed voxel size by one half in each dimension as well as with 0.27 x 0.27 x 2.0-mm (0.15 mm3) acquisition voxels and at 3.0 T with 0.27 x 0.27 x 2.0-mm (0.15 mm3) acquisition voxels using surface coils. The gradient intensities of the lumen-to-background interface varied closely with the contrast-to-noise ratio of the 2D-TOF imaging. For the DIR-BB imaging, in which higher spatial frequency artery structures are visible, the gradient intensities at the interfaces were higher than theoretically predicted at both field strengths with smaller acquisition voxels. The use of acquisition voxels smaller than those previously used at 1.5 T can improve the visualization of carotid artery structures at 1.5 and 3.0 T with surface coil reception.  相似文献   

9.
One thousand volume holographic data pages, each containing 1x10(6)pixels , are stored in a common volume of LiNbO(3) :Fe by use of the 90 degrees geometry. An effective transverse aperture of 1.6 mm x 1.6mm , realized by repetition of this experiment at each of the eight surrounding locations, results in a demonstrated areal density of 394pixels/mum (2) (254 Gpixels/in. (2)) . Short-focal-length Fourier optics provide a tightly confined object beam at the crystal; the reference beam is angle multiplexed. Data pages retrieved with a 1024 x 1024 CCD camera are processed to remap bad spatial light modulator pixels and to compensate for global and local pixel misregistration and are then decoded with a strong 8-bits-from-12-pixels modulation code. The worst-case raw bit-error rate (BER) before error correction was 1.1x10(-3) , sufficient to deliver a user BER of 10(-12) at an overall code rate of 0.61 user bits per detector pixel. This result corresponds to 1.08% of the well-known theoretical volumetric density limit of 1/lambda(3) .  相似文献   

10.
Sodium density maps acquired with three SPRITE-based methods have been compared in terms of the resulting quantitative information as well as image quality and acquisition times. Consideration of factors relevant for the clinical implementation of SPRITE shows that the Conical-SPRITE variant is preferred because of a 20-fold reduction in acquisition time, slightly improved image quality, and no loss of quantitative information. The acquisition of a 3D data set (32x32x16; FOV=256x256x160 mm) for the quantitative determination of sodium density is demonstrated. In vivo Conical-SPRITE 23Na images of the brain of a healthy volunteer were acquired in 30 min with a resolution of 7.5x7.5x7.5 mm and a signal-to-noise ratio of 23 in cerebrospinal fluid and 17 in brain tissue.  相似文献   

11.
The response of the cavity to the rotation of a point-like sample in the horizontal (y-z) plane passing through the center of the Bruker double TE(104) and single TE(102) rectangular cavities in concentric circles of radii rho = 0, 1, 2, 3, 4, and 5 mm from the cavity center (radial effect) has been analyzed. The experimentally observed dependencies of the EPR signal intensity, I(pp), showed the following: (i) for rho = 0 mm (a sample position in the cavity center), I(pp) is independent of the angle of rotation; (ii) for rho = 1, 2, and 3 mm, the I(pp) dependence progressively changes from circular to oval; (iii) when the radius is further increased to rho = 4 and 5 mm, the I(pp) dependence changes dramatically, giving a figure eight shape. These experimental observations are in very good agreement with the theoretical calculations, in which the response is modeled using modified Cassinian curves, K(rho, phi). Similar trends were observed for any position of the horizontal (y-z) plane at which the sample is situated along the vertical x axis of the cavity; however, the amplitude of the signal decreases with increase in the absolute value of the x coordinate, ||x ||. The variation in the signal amplitude along the cavity x axis (longitudinal effect) can be calculated theoretically using a modified sine-squared curve, G(x). In general, the response of the cavity to a point-like sample situated at any position, P(rho, phi, x), can be represented as a product of the mentioned Cassinian curve, K(rho, phi), and sine-squared curve, G(x), giving for the signal intensity I(pp)(rho, phi, x) approximately K(rho, phi)G(x). The response to a large cylindrical sample which is concentrically situated on the cavity x axis can then be obtained by integrating the above product, K(rho, phi)G(x), over the sample volume. The nonlinear radial effect may give rise to a serious source of systematic error in quantitative EPR spectroscopy and shows that accurate and precise positioning of the sample in the microwave cavity is essential.  相似文献   

12.
A shaped-based ultrasound tomography method is proposed to reconstruct ellipsoidal objects using a linearized scattering model. The method is motivated by the desire to detect the presence of lesions created by high intensity focused ultrasound (HIFU) in applications of cancer therapy. The computational size and limited view nature of the relevant three-dimensional inverse problem renders impractical the use of traditional pixel-based reconstruction methods. However, by employing a shape-based parametrization it is only necessary to estimate a small number of unknowns describing the geometry of the lesion, in this paper assumed to be ellipsoidal. The details of the shape-based nonlinear inversion method are provided. Results obtained from a commercial ultrasound scanner and a tissue phantom containing a HIFU-like lesion demonstrate the feasibility of the approach where a 20 mm x 5 mm x 6 mm ellipsoidal inclusion was detected with an accuracy of around 5%.  相似文献   

13.
A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 × 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laserproduced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/△E - 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas.  相似文献   

14.
冷却水中异味污染物的LC-GC/FTIR联用分析   总被引:2,自引:0,他引:2  
利用在线式高效液相色谱-毛细管气相色谱/傅里叶变换红光谱联用方法分析了某冷却水中的异味污染物。结果表明,污染系苯酚类化合物所致。  相似文献   

15.
Static gradient electron spin echo projection reconstruction imaging is favourable for X-band material science applications requiring temperature variation with a metal cryostat. To prevent imaging artefacts due to the high conduction electron diffusion coefficient in the preferred conduction direction of quasi-one-dimensional conductors, only pulsed gradient phase encoding for that direction can be tolerated. We present results of an appropriate cylindrical imaging scheme combining both methods. Conduction electron spin density images with 13 x 13 x 17 microm(3) volume element size or spin-lattice relaxation time images with inversion recovery sequence and 13 x 13 x 68 microm(3) volume element size are presented for fluoranthene radical cation salt single crystals of typical sizes of 0.4 x 0.4 x 1 mm(3).  相似文献   

16.
A new high-contrast, high-gain optical parametric chirped-pulse amplifier (OPCPA) architecture is demonstrated in periodically poled KTiOPO4 (PPKTP). This architecture overcomes parametric fluorescence contrast limitations of the OPCPA in periodically poled materials. The scheme is based on two passes of a single relay-imaged pump pulse and a free-propagating signal pulse through a 1.5 mm x 5 mm x 7.5 mm PPKTP crystal. The output energy of 1.2 mJ is generated at a center wavelength of 1053 nm by 24 mJ of pump energy. A prepulse contrast level of > 3 x 10(7) was measured with > 10(6) saturated gain in the amplifier. Amplified pulses were compressed to 200 fs. This simple and versatile concept requires only a modest pump energy from a commercial pump laser and represents a possible high-contrast front end for high-energy Nd:glass-based petawatt-class lasers.  相似文献   

17.
Ito T  Shimobaba T  Godo H  Horiuchi M 《Optics letters》2002,27(16):1406-1408
We reconstructed an animation made from computer-generated holograms with a reflective LCD panel that had a pixel pitch of 10 mumx10 mum and resolution of 1400x1050 . Using a LED as the reference light, we could clearly observe three-dimensional images whose size was approximately 30 mmx10 mm x30 mm . Moreover, we reconstructed a color holograph by use of a simple system with a set of red, green, and blue LEDs as the reference light.  相似文献   

18.
便携式紫外-可见分光光度计的设计   总被引:8,自引:1,他引:7  
介绍了一种便携式紫外-可见分光光度计的设计方法,该方法采用平场凹面全息光栅及Hamamatsu图像传感器S3904-1024Q为核心设计了小型化的色散系统;将多股光纤的一端排列成长方形直接作为入射狭缝,解决了光谱带宽与光源能量利用率之间矛盾的问题;采用触摸屏作为仪器的输入与输出设备及集成化的小型光纤光源作为仪器的光源。实验结果表明,采用该种方法设计的紫外-可见分光光度计体积小(190 mm×170 mm×100 mm)、操作简单(触摸屏操作)、可以多波长同时在线测量、技术指标符合国家标准。  相似文献   

19.
A diffractive Alvarez lens is demonstrated that consists of two separate phase plates, each having complementary 16-level surface-relief profiles that contain cubic phase delays. Translation of these two components in the plane of the phase plates is shown to produce a variable astigmatic focus. Both spherical and cylindrical phase profiles are demonstrated with good accuracy, and the discrete surface-relief features are shown to cause less than lambda/10 wave-front aberration in the transmitted wave front over a 40 mm x 80 mm region.  相似文献   

20.
Demonstration of chalcogenide glass racetrack microresonators   总被引:1,自引:0,他引:1  
We have demonstrated what we believe to be the first chalcogenide glass racetrack microresonator using a complementary metal-oxide semiconductor-compatible lift-off technique with thermally evaporated As(2)S(3) films. The device simultaneously features a small footprint of 0.012 mm x 0.012 mm, a cavity Q (quality factor) of 10,000, and an extinction ratio of 32 dB. These resonators exhibit a very high sensitivity to refractive index changes with a demonstrated detection capability of Dn(As(2)S(3)=(4.5 x 10(-6)+/-10%) refractive index unit. The resonators were applied to derive a photorefractive response of As(2)S(3) to lambda=550 nm light. The resonator devices are a versatile platform for both sensing and glass material property investigation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号