首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this wo rk,the phase-transitioned BSA(PTB) film using the mild and fast fabrication process adhered to the capillary inner wall uniformly,and the fabricated PTB film-coated capillary column was applied to realize open tubular capillary electrochromatography(OT-CEC) enantioseparation.The enantioseparation ability of PTB film-coated capillary was evaluated with eight pairs of chiral analytes including drugs and neurotransmitters,all achieving good resolution and symmetrical peak shape.For three consecutive runs,the relative standard deviations(RSD) of migration time for intra-day,inter-day,and column-tocolumn repeatability were in the range of 0.3%-3.5%,0.2%-4.9% and 2.1%-7.7%,respectively.Moreover,the PTB film-coated capillary column ran continuously over 300 times with high separation efficiency.Therefore,the coating method based on BSA self-assembly supramolecular film can be extended to the preparation of other proteinaceous capillary columns.  相似文献   

2.
Jin W  Fu H  Huang X  Xiao H  Zou H 《Electrophoresis》2003,24(18):3172-3180
Preparation of a poly(styrene-co-divinylbenzene-co-methacrylic acid) monolithic stationary phase for the use in capillary electrochromatography (CEC) has been improved by optimizing the polymerization conditions. It is observed that the reaction time strongly affects column efficiency, while the proportion of isooctane in porogen influences peak symmetry of some solutes seriously. The lifetime of the monolithic columns prepared mainly depends on the pH of buffers used. Reproducibility of electroosmotic flow (EOF) from batch to batch columns are lower than 2.8% relative standard deviation. Unlike other types of capillary electrochromatographic monoliths, a pH-dependent EOF was observed on this type of column. Separation of various types of compounds including aromatic hydrocarbons, hormones, anilines, basic pharmaceuticals, and peptides was achieved. The facile preparation and wide application of this monolithic column may make styrene-based polymer a potential stationary phase in CEC.  相似文献   

3.
Improved preparative electrochromatography column design   总被引:2,自引:0,他引:2  
Improved chromatography column fittings were developed for the efficient and reliable application of an electric field to a preparative chromatography column (a process termed electrochromatography). The improved fittings contained electrodes in close proximity to the column packing media and allowed uniform electric fields to be applied. Membranes in the fittings prevented mixing of the electrode and the column eluent buffers. The membranes prevented gases and electrolytic products generated in the electrode chamber from entering the column eluent buffer. An electrode buffer solution was pumped through the electrode chamber to a large external container. The circulation of buffer through the electrode chamber removed the gases and electrolytic products and ensured a uniform electric field by helping to maintain a constant buffer composition. The membranes prevented macromolecules being separated on the column from coming in contact with the electrodes.  相似文献   

4.
Capillary electrochromatography (CEC) is an emerging technique gaining increased interest. Improvement of instrumentation and column technology will be of prime importance for the further development of this technique and its use in validated methods. In this paper, developments in column technology and instrumentation for CEC are reviewed with emphasis on developments within the last 3 years. Attention is directed to the employment of stationary phases specifically designed for CEC, the use of soft and rigid gels in place of packings, fritless packed capillaries, column dimensions, the optimization of injection and detection parameters, and gradient elution CEC.  相似文献   

5.
Sakaki T  Kitagawa S  Tsuda T 《Electrophoresis》2000,21(15):3088-3092
The instrumentation for miniaturization of capillary electrochromatography was devised and an injection method for this apparatus was proposed. By using an ultra short capillary column (15 mm packed length, 36 mm total length, 75 microm inner diameter, packed with cation exchange supports), the separation of five biochemical compounds was performed within 1 min. The high separation efficiency of 9780 plates was achieved by using an ultrashort capillary column. The miniaturized instrumentation for capillary electrochromatography might be utilized as one of the possible methods in microfabricated analysis or in an alternative approach to it.  相似文献   

6.
A single-step approach has been used to prepare a monolithic electrochromatographic column by sol-gel processing of an organofunctional silicon alkoxide precursor that contains a propyl-N,N,N-trimethylammonium group. We have found that the time of adding the porogen, poly(ethylene glycol), during the sol-gel reaction affected the separation performance. Since the surface charge of this material is switchable in sign upon manipulation of solution pH, the direction and magnitude of the electroosmotic flow (EOF) can be controlled by adjusting the pH of the running electrolyte. By controlling the direction of the EOF from cathode to anode, inorganic anions can be separated in a short time. Because of the quaternary ammonium functional group, the resulting material is anion exchangeable. Interestingly, the anion-exchange selectivity of inorganic anions on this column changes with solution pH or applied voltage. The column shows excellent run to run reproducibility (R.S.D. < 0.4%), good day to day reproducibility (R.S.D. < 4%), and reasonable column to column reproducibility (R.S.D. < 9%).  相似文献   

7.
亲水作用毛细管电色谱是当前微分离技术的研究热点之一,其固定相的研究受到了广泛的关注。本文介绍了亲水作用毛细管电色谱开管柱、填充柱和整体柱的研究进展,重点对近年来发展的亲水作用电色谱整体柱的制备技术进行了系统阐述。引用文献68篇。  相似文献   

8.
Yan L  Zhang Q  Zhang W  Feng Y  Zhang L  Li T  Zhang Y 《Electrophoresis》2005,26(15):2935-2941
A novel hybrid organic-inorganic silica-based monolithic column possessing phenyl ligands for reversed-phase (RP) capillary electrochromatography (CEC) is described. The monolithic stationary phase was prepared by in situ co-condensation of tetraethoxysilane (TEOS) with phenyltriethoxysilane (PTES) via a two-step catalytic sol-gel procedure to introduce phenyl groups distributed throughout the silica matrix for chromatographic interaction. The hydrolysis and condensation reactions of precursors were chemically controlled through pH variation by adding hydrochloric acid and dodecylamine, respectively. The structural property of the monolithic column can be easily tailored through adjusting the composition of starting sol solution. The effect of PTES/TEOS ratios on the morphology of the created stationary phases was investigated. A variety of neutral and basic analytes were used to evaluate the column performance. The CEC columns exhibited typical RP chromatographic retention mechanism for neutral compounds and had improved peak shape for basic solutes.  相似文献   

9.
10.
Various parameters have been evaluated to develop a process for optimization of column manufacture for packed capillary electrochromatography (CEC). Spherisorb ODS-1 was packed into 75 microm I.D. capillaries to establish a standard set of packing conditions to afford high-performance columns free of voids. Numerous silica-based packing materials including porous and non-porous reversed-phase and ion-exchange phases were employed to evaluate the applicability of the standard conditions. Success of column manufacture and performance demonstrate a relationship to the colligative properties of the packing materials under the applied conditions. Frequently encountered difficulties arising from inadequate column conditioning and void formation in the packed bed are identified and discussed.  相似文献   

11.
Trietazine was selectively separated from aqueous solution containing the competitor molecule cyanazine, which is similar in size and shape to the template molecule. Structural features of the molecularly imprinted column were figured out by SEM. The influence of the mobile‐phase composition, applied electrical field, and pH of the mobile phase on the recognition of trietazine by the imprinted monolithic polymer has been evaluated, and the imprint effect in the trietazine‐imprinted monolithic polymer was demonstrated by an imprinting factor. The optimized monolithic column resulted in separation of trietazine from a structurally related competitor molecule, cyanazine. In addition, fast separation was obtained within 6 min by applying higher electrical field, with the electrophoretic mobility of 2.97 × 10?8 m2V?1s?1 at pH 11.0.  相似文献   

12.
Ye F  Xie Z  Wu X  Lin X  Chen G 《Journal of chromatography. A》2006,1117(2):170-175
A novel stationary phase phenylaminopropyl silica (PhA-silica) monolith was successfully prepared for pressure assisted capillary electrochromatography (pCEC). The monolithic silica matrix from a sol-gel process was chemically modified by using [3-(phenylamino)propyl]trimethoxysilane as surface modification reagent to produce the phenylaminoporpyl function. The secondary amino groups on the surface of the monolithic stationary phase contributed to the generation of anodic electroosmotic flow (EOF) under acidic conditions. The phenyl group together with the spacer (-(CH(2))(3)-) in PhA-silica provides sufficient hydrophobic properties. To evaluate the column performance, effects of buffer pH and mobile phase composition on the mobile phase linear velocity and the retention factors of alkylbenzenes, phenols and anilines were investigated in pCEC mode. The monolithic stationary phases exhibit typical reversed-phase (RP) electrochromatographic behavior toward neutral solutes. Hydrophobic as well as electrophoretic migration process within the monoliths was observed for the separation of basic solutes such as anilines without peak tailing.  相似文献   

13.
Hybrid silica monolithic stationary phase functionalized with octyl groups was synthesized by a two-step acid/base-catalyzed hydrolysis/co-condensation of tetraethoxysilane (TEOS) and n-octyltriethoxysilane (C(8)-TEOS). The influences of determining factors in the sol-gel process such as the monomer ratio and water content on the monolith formation were systematically investigated. An increase in the TEOS/C(8)-TEOS ratio in the polymerization mixture shifted the pore size distribution towards smaller pore diameter with larger pore volume. The optimal TEOS/C(8)-TEOS volume ratio was found to be 90/50, under which condition the median pore diameter of the monolith was around 1.0 microm with pore volume of 3.25 cm(3)/g. The chromatographic characteristics of the monolithic column prepared with the optimized fabrication condition were studied. Some aromatic compounds including alkylbenzenes, polycyclic aromatic hydrocarbons (PAHs) and phenols were successfully separated on the octyl-functionalized silica monolithic column with high column efficiency up to 180,000 plates/m.  相似文献   

14.
A new type of capillary column for open-tubular electrochromatography   总被引:1,自引:0,他引:1  
Zhao Y  Zhao R  Shangguan D  Liu G 《Electrophoresis》2002,23(17):2990-2995
A new type of open-tubular C(18) ester-bonded electrochromatographic column was prepared with sol-gel technology, followed by an on-column octadecyl silylation reaction. Glycidoxypropyltrimethoxysilane, a widely used and important silane agent, was used as the sol-gel precursor to form a thin coating layer on the wall of the fused-silica capillary. The C(18) groups were introduced into the coating layer by on-column esterification reaction with stearic acid. The electrochromatography behavior of the column was evaluated in terms of the separation of peptides. A high efficiency of 4.8x10(5) plates/m was achieved for a basic pentapeptide using the C(18 )ester-bonded column. In comparison with bare capillaries and glycidoxypropyltrimethoxysilane sol-gel-coated capillaries, the C(18) ester-bonded column showed the best separation of a mixture of seven pentapeptides under identical conditions of buffer, pH, and applied voltage.  相似文献   

15.
Polymethacrylate-based monolith with weak cation exchange functionalities was prepared in capillary column (i.d. 100 μm, o.d. 375 μm) by in situ polymerization of butyl methacrylate, ethylene dimethacrylate and N-methacryloyl-L-glutamic acid in presence of porogens. The porogen mixture included N,N-dimethyl formamide and phosphate buffer. The preparation procedure of stationary phase contained the synthesis of monomer, silanization of capillary inner wall and in situ polymerization. The use of amino acid based monomer for the monolith synthesis is one of the originalities of this novel approach. N-methacryloyl-L-glutamic acid has two carboxyl functionalities. The separation of the solutes were performed at different acetonitrile/phosphate buffer and acetonitrile/sodium hydroxide contents. The applied voltage for the alkyl benzenes was changed between +5 and +30 kV. CEC separations of alkyl benzenes, acidic, basic, phenolic and some polycylic aromatic compounds were succesfully performed under capillary-electrochromatography mode with cathodic electroosmotic flow.  相似文献   

16.
In capillary electrochromatography (CEC) the flow of the mobile phase is generated by electrosmotic means in high electric field. This work compares band spreading measured experimentally in several packed capillaries with electrosmotic flow (EOF) and viscous flow under otherwise identical conditions. The data were fitted to the simplified van Deemter equation for the theoretical plate height, H = A + B/u + Cu, in order to evaluate parameters A and C in each mode of flow in the different columns. The ratio of these two parameters obtained with the same column in microscale HPLC (mu-HPLC) and CEC was used to quantify the attenuation of their contribution to band spreading upon changing from viscous flow (in mu-HPLC) to electrosmotic flow (in CEC). The capillary columns used in this study were packed with stationary phases of different pore sizes as well as retentive properties and measurements were carried out under different mobile phase conditions to examine the effects of the retention factor and buffer concentration. In the CEC mode, the value of both column parameters A and C was invariably by a factor of two to four lower than in the mu-HPLC mode. This effect may be attributed to the peculiarities of the EOF flow profile in the interstitial space and to the generation of intraparticle EOF inside the porous particles of the column packing. Thus, band spreading due to flow maldistribution and mass transfer resistances is significantly lower when the mobile phase flow is driven by voltage as in CEC, rather than by pressure as in mu-HPLC.  相似文献   

17.
Ding G  Da Z  Yuan R  Bao JJ 《Electrophoresis》2006,27(17):3363-3372
A silica-based CEC monolithic column with mixed modes of RP and weak anion-exchange (WAX) was successfully prepared by using the sol-gel technique at mild temperature. The synthesizing procedure was optimized by changing the ratios of tetraethoxysilane (TEOS), aminopropyltriethoxysilane (APTES), and octyltriethoxysilane (C(8)-TEOS) in the mixture. While serving as WAX group, the amino group dominated the charge on the surface of the capillary column and generated an EOF from cathode to anode at low pH. At pH above 7.5, a cathodic EOF was observed due to the full ionization of silanol group and the suppression in the ionization of amino group. The morphology of monolithic columns was examined by SEM, and the performance of column was evaluated in detail by separating different kinds of compounds. As expected, the monolithic column exhibited RP chromatographic behavior for neutral solutes. Fast and efficient separation of six aromatic acids was obtained using acidic mobile phase with column efficiency up to 160,000 plates/m. Symmetrical peaks can be obtained for aromatic amines because positively charged amino groups on the surface can effectively minimize the adsorption of positively charged analytes to the stationary phase.  相似文献   

18.
A silica-based monolithic stationary phase with mixed-mode of reversed phase (RP) and weak anion-exchange (WAX) for capillary electrochromatography (CEC) has been prepared. The mixed-mode monolithic silica column was prepared using the sol–gel technique and followed by a post-modification with hexadecyltrimethoxysilane (HDTMS) and aminopropyltrimethoxysilane (APTMS). The amino groups on the surface of the stationary phase were used to generate a substantial anodic EOF as well as to provide electrostatic interaction sites for charged compounds at low pH. A cathodic EOF was observed at pH above 7.3 due to the full ionization of residual silanol groups and the suppression in the ionization of amino groups. A variety of analytes were used to evaluate the electrochromatographic characterization and column performance. The monolithic stationary phase exhibited RP chromatographic behavior toward neutral solutes. The model anionic solutes were separated by the mixed-mode mechanism, which comprised RP interaction, WAX, and electrophoresis. Symmetrical peaks can be obtained for basic solutes because positively charged amino groups can effectively minimize the adsorption of positively charged analytes to the stationary phase.  相似文献   

19.
A novel and convenient protocol for the preparation of an open-tubular column coated with chitosan-silica hybrid using chitosan and silane-coupling agent (γ-glycidoxy-propyltrimethoxysilane) was developed for CEC, in which, chitosan was covalently bonded to the inner wall of a fused-silica capillary using γ-glycidoxy-propyltrimethoxysilane as a cross-linking agent. The stationary phase was hydrophilic due to the chitosan-silica hybrid with abundant amine and hydroxyl functional groups. The chromatographic characteristics of the column were evaluated by the separation of some organic acids and inorganic anions. The column showed good selectivity for nucleotides, aromatic acids, and inorganic anions. The mechanism for the separation of these compounds was primarily based on the hydrophilic and electrostatic interactions combined with the electrophoretic mechanism. The CEC method on the column for the separation of these compounds was compared with CE method in a bare capillary.  相似文献   

20.
A column packed with red blood cells (RBCs) was prepared for electrochromatography as a separation and reaction column. RBCs were kept inside a piece of fused silica capillary tubing with 2% agarose gel. In the column, RBCs were uniformly distributed in the agarose gel matrix and their electrophoretic movements due to an applied voltage were suppressed well. The durability of the biological function of the column under applied voltage was about 1 h, although it could remain for 2-3 days without applied voltage. The column could not be used when hemolysis of the RBCs was observed in the column. When the developed "RBC-gel column" was used, both pyridoxamine and serotonin were converted to other compounds through their direct contact with RBCs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号