1.
An established method for the determination of the disinfection by-product bromate is ion chromatography (IC). This paper presents a comparison of three IC methods based on either conductivity detection (IC-CD), a post-column-reaction (IC-PCR-VIS) or the on-line-coupling with inductively coupled plasma mass spectrometry (IC-ICP-MS). Main characteristics of the methods such as method detection limits (MDL), time of analysis and sample pretreatment are compared and applicability for routine analysis is critically discussed. The most sensitive and rugged method is IC-ICP-MS, followed by IC-PCR-VIS. The photometric detection is subject to a minor interference in real world samples, presumably caused by carbonate. The lowest sensitivity is shown by the IC-CD method as slowest method compared, which, in addition, requires a sample pretreatment. The highest amount of information is delivered by IC-PCR-VIS, which allows the simultaneous determination of the seven standard anions and bromate.  相似文献   

2.
The on-line-coupling of ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) is a powerful tool for the determination of bromate in drinking waters. The use of a high-capacity and high-performance anion-exchanger combined with an NH4NO3-based elution system allows the determination of bromate in almost every water sample without any sample pretreatment. The method detection limits in the water samples investigated are 50 to 65 ng/L or 44 to 58 pg bromate, respectively. Considering sensivity as well as imprecision (5% at 500 ng/L bromate) and short analysis times (8 to 15 min per sample including sample uptake), the described IC-ICP-MS coupling is well suited for precise routine analyses of bromate in drinking waters at the sub μg/L level.  相似文献   

3.
Ion chromatography in combination with atmospheric pressure ionization mass spectrometry (API-MS) as well as with inductively coupled plasma mass spectrometry (ICP-MS) had been compared for trace analysis of bromate. The results indicate that both techniques yield comparable results, which are in excellent agreement with standard methods for bromate determination. Furthermore, both techniques showed almost equal absolute detection limits (approximately 50 pg bromate injected). Contrary to IC-API-MS, IC-ICP-MS can tolerate a higher salt concentration in the mobile phase. This allows the use of high-capacity columns combined with large sample volumes. This lowered the concentration based detection limits by one order of magnitude for IC-ICP-MS compared to IC-API-MS (0.06 microg/l vs. 0.5 microg/l). On the other hand, IC-API-MS is able to allow a positive identification of bromate even in cases when IC does not fully separate bromate from other bromine-containing species. The performance data of both IC-MS techniques have been established by participation in an international round robin test.  相似文献   

4.
The choice of the analytical method for the determination of actinide isotopes in leachate solutions has to be made considering several parameters: detection limit for each isotope, sample preparation procedure in terms of duration and complexity, counting time and interferences. A leachate solution obtained by keeping a pellet of UO2 doped with 238Pu in contact with distilled water was investigated for the content of U and Pu isotopes by radiometric methods (alpha-, gamma-spectrometry and liquid scintillation counting). The results of the radiometric methods were compared with those obtained from the analysis performed by inductively coupled plasma mass spectrometry on-line to a system for chromatographic separation (IC-ICP-MS). The comparison confirmed that IC-ICP-MS is a powerful method for the detection of long-lived radionuclides. The radiometric methods have a detection limit two orders of magnitude lower than IC-ICP-MS in the case of short-lived radioisotopes mostly due to the low background in the detector. On the other hand, the sample preparation and the analysis duration are more time-consuming compared to IC-ICP-MS; moreover, not all isotopes can be determined by using only one radiometric technique.  相似文献   

5.
The choice of the analytical method for the determination of actinide isotopes in leachate solutions has to be made considering several parameters: detection limit for each isotope, sample preparation procedure in terms of duration and complexity, counting time and interferences. A leachate solution obtained by keeping a pellet of UO2 doped with 238Pu in contact with distilled water was investigated for the content of U and Pu isotopes by radiometric methods (α-, γ-spectrometry and liquid scintillation counting). The results of the radiometric methods were compared with those obtained from the analysis performed by inductively coupled plasma mass spectrometry on-line to a system for chromatographic separation (IC-ICP-MS). The comparison confirmed that IC-ICP-MS is a powerful method for the detection of long-lived radionuclides. The radiometric methods have a detection limit two orders of magnitude lower than IC-ICP-MS in the case of short-lived radioisotopes mostly due to the low background in the detector. On the other hand, the sample preparation and the analysis duration are more time-consuming compared to IC-ICP-MS; moreover, not all isotopes can be determined by using only one radiometric technique.  相似文献   

6.
Ion chromatography (IC) is now a well established methodology for the analysis of ionic species. The technique is applicable to the determination of a wide range of solutes in many sample types, although the determination of inorganic ions in drinking water continues to be the most widely used application of ion chromatography. Many regulatory and standard organizations, such as ASTM, AOAC, ISO, and US EPA, have approved methods of analysis based upon IC, most of which have been published within the last 10 years. Recent developments in the field of IC, such as the use of higher capacity columns, larger loop injections, more complex sample preparation and detection schemes, have been incorporated into new approved methods to allow the determination of inorganic contaminants, such as bromate, perchlorate, and chromate, at low μg/l levels in drinking waters. IC appears certain to remain an important technique for drinking water analysis and new methods based on IC will continue to be developed as more inorganic contaminants become regulated at lower limits in the future.  相似文献   

7.
 Two different mass spectrometric methods, negative thermal ionization isotope dilution mass spectrometry (NTI-IDMS) and inductively coupled plasma mass spectrometry (ICP-MS), off-line and on-line coupled with anion exchange chromatography, have been developed for simultaneous bromide and bromate determinations in water samples. The detection limits of these methods are in the range of 0.03–0.09 μg/L using a 50 mL sample.The results are independent of the content of other anions, which could be demonstrated by the analyses of six mineral waters containing chloride and sulfate of up to 160 mg/L and 1500 mg/L, respectively. Bromide has been analyzed by the NTI-IDMS method in the range of 10–500 μg/L and bromate in the range of 1–50 μg/L with relative standard deviations of 0.3–1.2% and 0.4–6%. Quantification for the ICP-MS method was carried out by the standard addition technique, which resulted in relative standard deviations of 5.5% for bromide at the 500 μg/L level and of 13% for bromate at the level of about 3 μg/L. These results are compared with those described in the literature for ion chromatographic (IC) and other methods and those obtained in this work by IC using UV detection, which allows high concentrations of chloride in the bromate fraction. The detection limits of this IC method are 6 μg/L for bromide and 30 μg/L for bromate. NTI-IDMS and ICP-MS therefore fit the recommendations of the European Union (detection limit<2.5 μg/L; precision and accuracy better than 25% at the 10 μg/L level) for methods analyzing the carcinogenic bromate much better than IC and other methods applied up to now. As a definitive but time consuming method, NTI-IDMS is preferably applicable as a calibration technique, whereas ICP-MS, with relatively short analysis times, due to on-line coupling with chromatography, can be used as a sensitive and powerful routine method for trace bromide and bromate species in water samples. Received: 5 July 1996/Accepted: 7 August 1996  相似文献   

8.
For the first time, an ion chromatographic method for the simultaneous determination of the disinfection by-products bromate, chlorite, chlorate, and the so-called seven standard anions, fluoride, chloride, nitrite, sulfate, bromide, nitrate and orthophosphate is presented. The separation of the ten anions was carried out using a laboratory-made high-capacity anion-exchanger. The high capacity anion-exchanger allowed the direct injection of large sample volumes without any sample pretreatment, even in the case of hard water samples. For quantification of fluoride, chloride, nitrite, sulfate, bromide, nitrate, orthophosphate and chlorate, a conductivity detection method was applied after chemical suppression. The post-column reaction, based on chlorpromazine, was optimized for the determination of chlorite and bromate. The method detection limit for bromate measured in deionized water is 100 ng/l and for chlorite, it is 700 ng/l. In hard drinking water, the method’s detection limits are 700 ng/l (bromate) and 3.5 μg/l (chlorite). The method’s detection limits for the other eight anions, determined by conductivity detection, are between 100 μg/l (nitrite) and 1.6 mg/l (chlorate).  相似文献   

9.
 Two different mass spectrometric methods, negative thermal ionization isotope dilution mass spectrometry (NTI-IDMS) and inductively coupled plasma mass spectrometry (ICP-MS), off-line and on-line coupled with anion exchange chromatography, have been developed for simultaneous bromide and bromate determinations in water samples. The detection limits of these methods are in the range of 0.03–0.09 μg/L using a 50 mL sample.The results are independent of the content of other anions, which could be demonstrated by the analyses of six mineral waters containing chloride and sulfate of up to 160 mg/L and 1500 mg/L, respectively. Bromide has been analyzed by the NTI-IDMS method in the range of 10–500 μg/L and bromate in the range of 1–50 μg/L with relative standard deviations of 0.3–1.2% and 0.4–6%. Quantification for the ICP-MS method was carried out by the standard addition technique, which resulted in relative standard deviations of 5.5% for bromide at the 500 μg/L level and of 13% for bromate at the level of about 3 μg/L. These results are compared with those described in the literature for ion chromatographic (IC) and other methods and those obtained in this work by IC using UV detection, which allows high concentrations of chloride in the bromate fraction. The detection limits of this IC method are 6 μg/L for bromide and 30 μg/L for bromate. NTI-IDMS and ICP-MS therefore fit the recommendations of the European Union (detection limit<2.5 μg/L; precision and accuracy better than 25% at the 10 μg/L level) for methods analyzing the carcinogenic bromate much better than IC and other methods applied up to now. As a definitive but time consuming method, NTI-IDMS is preferably applicable as a calibration technique, whereas ICP-MS, with relatively short analysis times, due to on-line coupling with chromatography, can be used as a sensitive and powerful routine method for trace bromide and bromate species in water samples. Received: 5 July 1996/Accepted: 7 August 1996  相似文献   

10.
刘晶  何青青  杨丽莉  胡恩宇  王美飞 《色谱》2015,33(10):1110-1114
建立了一种测定水中痕量及超痕量溴酸盐的在线富集大体积进样离子色谱法。采用实验室常备的柱容量较高的Dionex IonPac AG23保护柱作为浓缩柱,连接在定量环处富集溴酸盐。淋洗液自动发生装置在线生成高纯度氢氧化钾淋洗液进行梯度洗脱,抑制电导检测。实验结果表明:溴酸盐质量浓度范围在0.05~51.2 μg/L之间时线性关系良好,相关系数r≥0.9995,方法检出限为0.01 μg/L。与常规进样相比,进样量可高达5 mL,浓缩因子约为240倍。本方法成功应用于市售纯净水中溴酸盐的测定,2个加标水平的回收率在90%~100%之间,RSD(n=6)为2.1%~6.4%。该方法无需前处理,操作简单,准确度和精密度良好。通过大体积进样实现高倍富集,适用于痕量及超痕量溴酸盐的分析。  相似文献   

11.
Quantitative determination of trace glyphosate and phosphate in waters was achieved by coupling ion chromatography (IC) separation with inductively coupled plasma mass spectrometry (ICP-MS) detection. The separation of glyphosate and phosphate on a polymer anion-exchange column (Dionex IonPac AS16, 4.0 mm x 250 mm) was obtained by eluting them with 20 mM citric acid at 0.50 mL min(-1), and the analytes were detected directly and selectively by ICP-MS at m/z = 31. Parameters affecting their chromatographic behaviors and ICP-MS characteristics were systematically examined. Based on a 500-microL sample injection volume, the detection limits were 0.7 microgL(-1) for both glyphosate and phosphate, and the calibrations were linear up to 400 microgL(-1). Polyphosphates, aminomethylphosphonic acid (the major metabolite of glyphosate), non-polar and other polar phosphorus-containing pesticides showed different chromatographic behaviors from the analytes of interest and therefore did not interference. The determination was also interference free from the matrix anions (nitrate, nitrite, sulphate, chloride, etc.) and metallic ions. The analysis of certified reference material, drinking water, reservoir water and Newater yielded satisfactory results with spiked recoveries of 97.1-107.0% and relative standard deviations of < or = 7.4% (n = 3). Compared to other reported methods for glyphosate and phosphate, the developed IC-ICP-MS method is sensitive and simple, and does not require any chemical derivatization, sample preconcentration and mobile phase conductivity suppression.  相似文献   

12.
Flow injection analysis (FIA) with ESI-MS and ion chromatography (IC) with inductively coupled plasma-MS (ICP-MS) as the complementary technique have been explored for the determination of metal ions as their metal-EDTA complexes. ESI-MS enabled the identification of metal-EDTA complexes such as [Mn(EDTA)](2-), [Co(EDTA)](2-), [Ni(EDTA)](2-), [Cu(EDTA)](2-), [Zn(EDTA)](2-), [Pb(EDTA)](2-), and [Fe(EDTA)](1-) and their MS spectral showed that these metal-EDTA complexes were present in solution. Based on the ESI-MS, ion chromatographic separation and ICP-MS detection of these complexes are possible because IC-ICP-MS requires stable metal-EDTA complex during the chromatographic separation. The separation of these metal-EDTA complexes was achieved on an anion-exchange column with a mobile phase containing 30 mM NH(4)(HPO(4))(2) at pH 7.5 within 7 min with ICP-MS providing element specific detection. The ICP-MS LODs for the metal-EDTA were in the range of 0.1-0.5 microg/L with the exception of Fe (15 microg/L). The proposed method was a simple procedure for sample processing, using direct injection of sample without removal of sample matrix and was successfully applied to the determination of metal-EDTA complexes in real samples.  相似文献   

13.
建立以大体积进样(250μL)–离子色谱测定水中溴酸盐(BrO_3~–)的方法。采用Ag柱离线去除样品中大量Cl~–以消除Cl~–干扰,同时保证痕量溴酸盐未沉淀,过滤后直接进样测定。BrO_3~–的质量浓度在2.0~25.0μg/L范围内与色谱峰面积呈良好的线性关系,线性相关系数r=0.999 2,方法检出限为0.8μg/L。自来水和矿泉水样品3浓度水平加标回收率为85.0%~101.0%,测定结果的相对标准偏差为3.6%~12.9%(n=6)。该方法样品处理简单,检出限低,准确度和精密度高,满足分析测试的要求。  相似文献   

14.
A simple,fast,precise and eco-friendly analytical method for the determination of uric acid(UA) in human urine by ion chromatography(IC) was established.The sample pretreatment was not required,only needed centrifugation and filtration.The separation was carried out on a cation exchange column with 2.0 mmol/L nitric acid as mobile phase at the flow-rate 1.0 mL/min.A non-suppressed conductivity detector was used.The IC analysis time for one run was within 10 min under the optimized IC condition.The detection limits were 0.5μg/L(S/N = 3) for uric acid.The recovery was 100.1%while the relative standard deviation (RSD) was 1.8%from 10 measurements.  相似文献   

15.
Based on selective sorption of bromide, bromoacetic acids (BAA) and bromomethanes on solid-phase extraction (SPE) cartridges, a sensitive and convenient method was developed for the determination of bromate in waters by inductively coupled plasma mass spectrometry (ICP–MS). Dionex OnGuard Ag and reversed-phase (RP) cartridges were tested for retention characteristics for bromide, BAA and bromomethanes. When a sample acidified with nitric acid was passed through an RP cartridge, BAA and bromomethanes were retained, afterwards bromide was absorbed as a precipitate of silver bromide and bromate was unretained when the nearly neutral sample passed a combination of Ag and H cartridges. After SPE pretreatment the recovery of bromate was 96–106%, and bromide remaining in the aqueous phase was found to be less than 0.06 g L–1 when the original bromide concentrations were less than 5 mg L–1. Effectiveness of stacked Ag and H cartridges in removing bromide from chloride-containing samples was also examined. Common cations and other anions did not interfere with bromate determination. The detection limit for bromate is 57 ng L–1. This method has been applied to analyse waters from various sources, and the recovery of the spiked bromate was in the range of 92–107%.  相似文献   

16.
The use of elemental mass spectrometry as detection for ion chromatography allows sensitive determination of several bromine and iodine species at a reasonable time scale. Lowest concentrations observable are 66 ng L(-1) for bromate, 45 ng L(-1) for iodate, 74 ng L(-1) for bromide and 151 ng L(-1) for iodide. A major drawback of previous IC-ICP-MS applications is the high consumption of time and thus the running costs. The use of GeO2 as internal standard not only allows improved external calibration, but also semiquantitative determination of bromate, bromide, iodate and iodide without any calibration procedure. Furthermore, GeO2 can be used for all known types of anion exchange columns regardless of their construction principles. It is shown, that the analyte-to-GeO2 ratio of four bromine and iodine species was nearly constant over 4 months and almost independent from the ICP-MS instrumental settings. The quantification by means of the analyte-to-GeO2 ratio for samples taken from a bromate round robin test shows that the values obtained are in excellent agreement with calibration curve and isotope dilution results.  相似文献   

17.
In this study, ion chromatography (IC) with suppressed conductivity detection was used for the determination of trace anions in 29% (w/w) ammonium hydroxide, 49% (w/w) hydrofluoric acid and slurries. For these samples, various sample pretreatment methods were applied to eliminate matrix interferences. For concentrated ammonium hydroxide, an on-line electrochemical neutralizer (SP10 AutoNeutralization module) was used to neutralize the base prior to the IC analysis. For concentrated hydrofluoric acid, a heart cutting technique with an ion-exclusion column was used to separate the anions of interest prior to an IC separation. A method was also developed to analyze chloride in silica slurries by IC.  相似文献   

18.
An electrostatic ion chromatographic (IC) method for rapid and direct determination of iodide in seawater is reported. Separation was achieved using a reversed-phase ODS packed column (250x4.6 mm I.D.) modified by coating with Zwittergent-3-14 micelles, with an eluent comprising an aqueous solution containing 0.2 mM NaClO4 and 0.3 mM Zwittergent-3-14 and using UV detection at 210 nm. Samples prepared by dissolving NaIO3, NaNO2, NaBr, NaBrO3, NaNO3, NaI, and NaSCN in artificial or real seawaters were analyzed using this IC system. Nitrite, iodate, bromide, bromate, and nitrate showed very little or no retention, while iodide and thiocyanate were well separated, being eluted within 6 and 16 min, respectively. The detection limit for iodide obtained by injecting 400 microL of sample was 0.011 microM (S/N = 3), and the precision values obtained by analyzing samples containing 0.1 or 0.3 microM iodide in real seawater samples were 2.3% RSD and 1.2% RSD, respectively. Direct determination of iodide in real seawater samples was possible using this proposed IC system.  相似文献   

19.
Honglan Shi  Craig Adams 《Talanta》2009,79(2):523-183
Haloacetic acids (HAAs) and bromate are toxic water disinfection by-products (DBPs) that the U.S. Environmental Protection Agency has regulated in drinking water. Iodoacetic acids (IAAs) are the emerging DBPs that have been recently found in disinfected drinking waters with higher toxicity than their corresponding chloro- and bromo-acetic acids. This study has developed a new rapid and sensitive method for simultaneous analysis of six brominated and four iodinated acetic acids, bromate, iodate, bromide, and iodide using ion chromatography-inductively coupled plasma-mass spectrometry (IC-ICP-MS). Mono-, di- and tri-chloroacetic acids are not detected by this method because the sensitivity of ICP-MS analysis for chlorine is poor. Following IC separation, an Elan DRC-e ICP-MS was used for detection, with quantitation utilizing m/z of 79, 127, and 74 amu for Br, I, and Ge (optional internal standard) species, respectively. Although the primary method used was an external standard procedure, an internal standard method approach is discussed herein as well. Calibration and validation were done in a variety of natural and disinfection-treated water samples. The method detection limits (MDLs) in natural water ranged from 0.33 to 0.72 μg L−1 for iodine species, and from 1.36 to 3.28 μg L−1 for bromine species. Spiked recoveries were between 67% and 123%, while relative standard deviations ranged from 0.2% to 12.8% for replicate samples. This method was applied to detect the bromine and iodine species in drinking water, groundwater, surface water, and swimming pool water.  相似文献   

20.
On-line coupling of inductively coupled plasma (ICP) techniques such as ICP-AES and ICP-MS with ion chromatography (IC) offers unique features for ultra-trace analysis. An on-line preconcentration procedure based on cation exchange enables sub-ng/g analysis in complex matrices like molybdenum and tungsten. The best dissolution reagent for these matrices is hydrogen peroxide, which can be cleaned to ultra high purity with the same metal free chromatography equipment used for the preconcentration. Preconcentration is possible for elements that show cationic reactions within acidic peroxide containing solutions. In this study 28 elements detrimental for microelectronics applications are observed. A comparison of the combinations IC-ICP-AES and IC-ICP-MS with glow discharge mass spectrometry (GDMS) for the analysis of today's purest tungsten samples shows the analytical power and accuracy of the coupled devices. Graphite furnace atomic absorption spectrometry (GFAAS) as an extremely sensitive analytical technique is applied with and without the same sample pretreatment as used for the on-line coupling. Direct GFAAS measurements of alkali metals are complementary to IC-ICP techniques. The data evaluated with these wet chemical techniques are compared to the usual manufacturers characterisation technique GDMS. With respect to the low concentrations present in these high purity materials (ng/g level in the solid) the discrepancies between all methods are acceptable. The sensitivity of IC-ICP-MS is in most cases far superior to IC-ICP-AES and for some elements also to GDMS. Furthermore the specific advantages of on-line coupling such as the elimination of isobaric interferences in ICP-MS or spectral interferences in ICP-AES are shown for ICP-AES and ICP-MS determinations.  相似文献   