首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Quantitative determinations of ions in a variety of media have been performed traditionally via one of three approaches: optical instrumental methods (e.g., atomic absorption, and inductively-coupled plasma-optical emission or mass spectrometry), “wet” methods, or ion-selective sensors. Each of the approaches, though, possesses limitations including: power/reagent consumption and lack of portability for instrumental techniques; laborious sample-treatment steps for wet methods; and lack of selectivity and sensitivity with sensors when employed with complex samples. Microfluidic device have emerged as a solution to some of these challenges associated with ion analysis. Such systems can integrate multiple sample handling, calibration, and detection steps (“lab-on-a-chip” concept) into a footprint amenable to portability, while requiring small amounts of sample and power. Furthermore, devices can be constructed for multi-analyte detection, either through multiple parallel fluidic architectures or by using arrays of detection elements. This paper reviews recent progress in the development of total-analysis systems for ionic species. Fabrication techniques and various fluid-handling operations are discussed briefly, followed by a number of more mature strategies for microfluidic ion analysis. A variety of approaches expected to comprise the next generation of devices are also presented.  相似文献   

2.
Standard gases are used for quality control and quality assurance, development of analysis methods and novel air sampling devices. The use of solid-phase microextraction (SPME) and other novel technologies for research in the area of air sampling and analysis requires systems/devices for reliable standard gas generation and sampling. In this paper we describe a new gas standard generating system for volatile organic compounds (VOCs) and semi-VOCs that was designed, built, and tested to facilitate fundamental and applications research with SPME. The system provided for the generation of a wide range of VOC/semi-VOC concentrations and mixing various standard gases, estimation of detection limits, testing the effects of sampling time, air temperature and relative humidity, testing the effects of air velocity and ozone on sampling/extractions. The system can be also used for calibrations of analytical instrumentation, quality control and quality assurance checks, and cross-validations of SPME with/and other sampling techniques.  相似文献   

3.
Sample preparation is the procedure before instrumental analysis and significant to its effectiveness and efficiency. However, this procedure is usually time‐consuming, labor intensive, and prone to error. In the last decade, the development of sample preparation techniques has received increasing attention, especially in complex sample application. To pretreat samples faster and more effectively, advanced materials, instrumentation, and methods have been combined with typical techniques, including extraction, membrane separation, and chemical conversion techniques. Researchers in China focused on the development of simple, efficient sample preparation methods with selective enrichment and rapid separation capabilities for target analysis in complicated sample matrix and contribute almost a half of the publications in this specific field. In this review, a panorama of sample preparation techniques in China has been composed from more than 140 references, and we highlight some promising methods developed during recent years and introduce different separation materials with respect to these methods.  相似文献   

4.
Chiral separations facilitated using microchip devices are reviewed in this paper. The first research paper on this topic was published in 1999. It was seen that analysis times are greatly reduced compared with more conventional techniques such as liquid chromatography and capillary electrophoresis, and that these devices enable the separation of chiral molecules. Method optimization can be conducted in a rather easy manner, reducing the total method development time. Finally, minute amounts of sample and buffer are used during analysis, which makes the systems ultra-economical. Although the number of applications in the chiral separation field on these miniaturized systems is still rather limited, they exhibit much potential towards high-throughput screening. Some efforts are, however, still needed regarding detection modes, because derivatisation of the samples is often needed to enable their detection.  相似文献   

5.
The increasing demand for faster, more cost-effective and environmentally friendly analytical methods is a major incentive to improve the classical procedures used for sample treatment in environmental analysis. In most classical procedures, the use of rapid and powerful instrumental techniques for the final separation and detection of the analytes contrasts with the time-consuming and usually manual methods used for sample preparation, which slows down the total analytical process. The efforts made in this field in the past ten years have led to the adaptation of existing methods and the development of new techniques to save time and chemicals, and improve overall performance. One route has been to develop at-line or on-line and, frequently, automated systems. In these approaches, miniaturization has been a key factor in designing integrated analytical systems to provide higher sample throughput and/or unattended operation. Selected examples of novel developments in the field of miniaturized sample preparation for environmental analysis are used to evaluate the merits of the various techniques on the basis of published data on real-life analyses of trace-level organic pollutants. Perspectives and trends are briefly discussed.  相似文献   

6.
7.
Summary The automation of chromatographic systems is of increasing interest to industry and research laboratories in routine applications. Besides potentially saving time or making better use of available instrumentation, automation also improves the quality of results by producing more precise and more reproducible HPLC data. The need for the validation of methods and qualification of instruments is increasingly recognised in order to ensure compliance with legal requirements (e.g. in the pharmaceutical industry) and to ensure the reliability of analytical results. Possibilities and requirements for automated HPLC systems are elaborated. Emphasis is placed on defining the goals of validation and on discussing different aspects of the validation of LC methods, system suitability tests, ruggedness of methods and the transfer of LC methods from laboratory to laboratory. Adequate strategies of HPLC method development provide very useful information on the validation and ruggedness of LC methods.  相似文献   

8.
Development of techniques for the analysis of the content of individual cells represents an important direction in modern bioanalytical chemistry. While the analysis of chromosomes, organelles, or location of selected proteins has been traditionally the domain of microscopic techniques, the advances in miniaturized analytical systems bring new possibilities for separations and detections of molecules inside the individual cells including smaller molecules such as hormones or metabolites. It should be stressed that the field of single cell analysis is very broad, covering advanced optical, electrochemical and mass spectrometry instrumentation, sensor technology and separation techniques. The number of papers published on single cell analysis has reached several hundred in recent years. Thus a complete literature coverage is beyond the limits of a journal article. The following text provides a critical overview of some of the latest developments with the main focus on mass spectrometry, microseparation methods, electrophoresis in capillaries and microfluidic devices and respective detection techniques for performing single cell analyses.  相似文献   

9.
Chromatomembrane (CM) cells operate in computer-aided FIA systems as unique manifolds for extraction and preconcentration procedures. By coupling with ion chromatography an instrumentation was obtained allowing sample preparation and detection of nitrogen oxides in air in a quick and automated way. The aim of this paper is to study the absorption of acid components from air inside the new devices.  相似文献   

10.
Nyholm L 《The Analyst》2005,130(5):599-605
During the last few years there has been a rapid increase in the use of electrochemical reactions in lab-on-a-chip devices. This development, which has so far mainly focussed on electrochemical detection in chip-based capillary electrophoresis, can be explained by the fact that electrochemical techniques and devices are particularly well-suited for inclusion in lab-on-a-chip systems. The most important reason for this is that the required electrodes can readily be manufactured and miniaturised without loss of analytical performance using conventional microfabrication methods. In this Research Highlight article, the developments during the last three years concerning electrochemical techniques for lab on-a-chip applications are discussed, with particular focus on emerging electrochemical methods for sample clean-up and preconcentration, electrochemical derivatisation and electrochemical detection in chip-based capillary electrophoresis.  相似文献   

11.
The development of novel and reliable technologies for the analysis of proteins and their post-translational modifications, in particular, has recently received much attention and interest. The implementation of a fully integrated microfluidic device interfaced with MS detection for the analysis of phosphoproteins is presented in this paper. The microfluidic platform (3'x1.5') comprises two individual sample processing systems: one for performing direct sample infusion and one for performing microfluidic LC separations. Various MS detection strategies, specific for the study of post-translational modifications, were conducted using alpha-casein as a model protein. Neutral loss ion mapping, data-dependent triple-play and neutral loss analysis, and in situ dephosphorylation followed by LC separation and MS detection were performed. Consistent results in identifying phosphopeptides with conventional and microfluidic instrumentation have been obtained. Unlike with conventional instrumentation, however, the microfluidic device enabled the completion of each analysis from only a few microliters of sample, in approximately 10-15 min, and on a bioanalytical platform that facilitates multiplexing and disposability, and thus high-throughput, contamination-free analysis.  相似文献   

12.
Recent developments in microcolumn liquid chromatography.   总被引:5,自引:0,他引:5  
An overview of the most recent developments in microcolumn liquid chromatography (LC) is presented. A short theoretical discussion on chromatographic dilution and extracolumn bandbroadening is given and also the recent progress and advances in column technology and instrumentation are reviewed. However, the emphasis of this review is on miniaturized sample clean-up, sample introduction techniques and on both established and more recent detection techniques for microcolumn LC. The hyphenation of miniaturized LC columns with other techniques, specifically on multidimensional chromatography and the coupling of microcolumn LC to mass spectrometry is discussed in detail. Both the on-line and automated off-line interfacing to other separation and detection techniques will also be addressed. Finally, a number of typical microcolumn LC applications are presented in order to demonstrate the potential of microcolumn LC methods in a variety of scientific areas.  相似文献   

13.
In the field of environmental analysis there is still great potential for development and application of immunoanalytical techniques (IT). Heterogeneous and homogeneous immunoassays (IA), flow-injection immunoanalysis (FIIA) and immunosensors (IS) with different detection principles have been developed. In this review we focus on fluorescence methods for pesticide monitoring published since 1992. These techniques offer a high degree of selectivity and, in principle, sensitivity. Restrictions on the limits of detection (LOD) due to background signals are minimized by development of solid-phase separation systems, new fluorescent probes, and new instrumentation.  相似文献   

14.
Besides atomic absorption spectrometry, the plasma techniques can be seen as state-of-the-art instrumentation in an industrial laboratory for the analysis of trace elements today. For the analysis of refractory metals, e.g. Mo and W, the determination limits which can be reached by ICP-AES techniques are mainly restricted by the spectral background of the matrix. Advantages and disadvantages of sequential and simultaneous detection as well as different methods of evaluation, such as Kaiman filtering and multiple component spectral fitting, are discussed. The results are compared with trace matrix separation techniques and on-line coupling of ion chromatography with ICP-AES and ICP-MS. Furthermore, the limitations of all techniques with respect to their applicability for routine analysis, especially the complexity of sample preparation, degree of automation, time consumption and cost are shown. With respect to the detection capability, TMS with ICP-MS end determination is the most powerful technique, but for routine analysis simultaneous multielement determination from the matrix is favourable.  相似文献   

15.
In the field of environmental analysis there is still great potential for development and application of immunoanalytical techniques (IT). Heterogeneous and homogeneous immunoassays (IA), flow-injection immunoanalysis (FIIA) and immunosensors (IS) with different detection principles have been developed. In this review we focus on fluorescence methods for pesticide monitoring published since 1992. These techniques offer a high degree of selectivity and, in principle, sensitivity. Restrictions on the limits of detection (LOD) due to background signals are minimized by development of solid-phase separation systems, new fluorescent probes, and new instrumentation.  相似文献   

16.
The availability of pharmaceuticals to treat and to prevent disease has brought great benefit. Nevertheless, attention is being drawn to the uncontrolled use and careless disposal of medications for humans and animals. These compounds and their metabolites are found in the environment and foodstuffs, with possible adverse risks to human health.Detection of pharmaceuticals and residues in environmental and biological matrices has become a priority for governmental agencies. However, current analytical methods capable of detecting pharmaceuticals at very low levels require time-consuming sample preparation, concentration and/or extraction prior to analysis.Biosensors offer several advantages over existing techniques (e.g., less time, high-throughput screening, improved sensitivity, real-time analysis and the possibility of developing label-free detection methods and devices). Also, incorporation of nanotechnology into biosensor systems may increase the speed and the capability of the diagnostic methods. Moreover, the possibility of using biosensor systems in different configurations allows us envisaging their implementation as point-of-care systems or multiplexed devices.This review provides a general overview of the progress, the limitations and the future challenges of biosensors for detecting pharmaceuticals.  相似文献   

17.
An ever-increasing priority of many customers in the radiochemistry field is the turn-around time of sample analysis. While modern instrumentation provides acceptable detection limits with relatively short count times, the sample preparation step remains the time-consuming step in radiochemical analysis. We have developed fast sample preparation techniques for gross alpha/beta analysis based on ultrasonically assisted digestion as part of a mobile radiological analytical laboratory program in place at Los Alamos National Laboratory (LANL).  相似文献   

18.
Recent advances in electrochemical detection in capillary electrophoresis   总被引:3,自引:0,他引:3  
Baldwin RP 《Electrophoresis》2000,21(18):4017-4028
Recent advances in the design and application of electrochemical (EC) detection systems in capillary electrophoresis (CE) are reviewed, with the objective of providing the nonelectrochemist with a state-of-the-art picture of CEEC instrumentation and an overview of the principal analytes for which CEEC is best suited. The detection schemes considered here include those based both on amperometry and on potentiometry as both kinds of EC systems are being actively developed in CE and have the potential for broad application in analysis. Over the three-year period covered by this review, an important direction that CEEC has taken is the construction of more complex electrode systems beginning with the use of multiple EC electrodes and culminating with the adaptation of EC detection to microfabricated "lab-on-a-chip" analysis devices. In addition, CEEC applications have now grown to include a broad variety of inorganic, organic, and biochemical analytes and samples.  相似文献   

19.
The number of applications of microfluidic analysis systems continues to increase, along with the variety of substrate materials and complexity of the devices themselves. One of the most common features of these devices that has remained relatively unchanged, however, is the introduction of a sample mixture into a separation channel so that individual components can be separated by electrophoresis. Whether a relatively simple mixture of amino acids or a more complex sample of DNA fragments extracted and amplified on-chip, the ability to reliably and reproducibly inject a representative sample is arguably the most significant requirement for an electrophoretic micro total analysis system (μTAS). This review will focus on the different methods reported for sample introduction in microchip electrophoresis, highlighting both pressure-driven and electrokinetic techniques, with an emphasis on the methods employed in μTAS applications.  相似文献   

20.
Chromatomembrane (CM) cells operate in computer-aided FIA systems as unique manifolds for extraction and preconcentration procedures. By coupling with ion chromatography an instrumentation was obtained allowing sample preparation and detection of nitrogen oxides in air in a quick and automated way. The aim of this paper is to study the absorption of acid components from air inside the new devices. Received: 11 September 1997 / Revised: 12 November 1997 / Accepted: 16 November 1997  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号