首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
Desorption electrospray ionisation mass spectrometry (DESI‐MS) was recently reported for the direct analysis of sample media without the need for additional sample handling. During the present study, direct analysis of solid‐phase microextraction (SPME) fibers by DESI‐MS/MS was evaluated with indoor office media that might be collected during a forensic investigation, including wall surfaces, office fabrics, paper products and Dacron swabs used for liquid sampling. Media spiked at the µg/g level with purified chemical warfare agents and a complex munitions grade sample of tabun, to simulate the quality of chemical warfare agent that might be used for terrorist purposes, were successfully analysed by DESI‐MS/MS. Sulfur mustard, a compound that has not been successfully analysed by electrospray mass spectrometry in the past, was also sampled using a SPME fiber and analysed for the first time by DESI‐MS/MS. Finally, the overall analytical approach involving SPME headspace sampling and DESI‐MS analysis was evaluated during a scenario‐based training live agent exercise. A sarin sample collected by the military was analysed and confirmed by DESI‐MS in a mobile laboratory under realistic field conditions. Copyright © 2007 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.  相似文献   

2.
Desorption electrospray ionization mass spectrometry (DESI‐MS) has been applied to the direct analysis of sample media for target chemicals, including chemical warfare agents (CWA), without the need for additional sample handling. During the present study, solid‐phase microextraction (SPME) fibers were used to sample the headspace above five organophosphorus CWA, O‐isopropyl methylphosphonofluoridate (sarin, GB), O‐pinacolyl methylphosphonofluoridate (soman, GD), O‐ethyl N,N‐dimethyl phosphoramidocyanidate (tabun, GA), O‐cyclohexyl methylphosphonofluoridate (cyclohexyl sarin, GF) and O‐ethyl S‐2‐diisopropylaminoethyl methyl phosphonothiolate (VX) spiked into glass headspace sampling vials. Following sampling, the SPME fibers were introduced directly into a modified ESI source, enabling rapid and safe DESI of the toxic compounds. A SYNAPT HDMS? instrument was used to acquire time‐aligned parallel (TAP) fragmentation data, which provided both ion mobility and MSn (n = 2 or 3) data useful for the confirmation of CWA. Unique ion mobility profiles were acquired for each compound and characteristic product ions of the ion mobility separated ions were produced in the Triwave? transfer collision region. Up to six full scanning MSn spectra, containing the [M + H]+ ion and up to seven diagnostic product ions, were acquired for each CWA during SPME fiber analysis. A rapid screening approach, based on the developed methodology, was applied to several typical forensic media, including Dacron sampling swabs spiked with 5 µg of CWA. Background interference was minimal and the spiked CWA were readily identified within one minute on the basis of the acquired ion mobility and mass spectrometric data. Copyright © 2010 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.  相似文献   

3.
Packed capillary column liquid chromatography (LC)–electrospray mass spectrometry (ESI-MS) was used for the first time to detect and identify four common organophosphorus chemical warfare agents in aqueous samples. Aqueous samples containing the organophosphorus chemical warfare agents in the 0.01 to 0.1 mg/ml range were analyzed directly by packed capillary LC–ESI-MS with the chemical warfare agents and several minor related impurities being well resolved under acetonitrile–water gradient elution conditions. The ESI-MS data for isopropyl methylphosphonofluoridate (sarin or GB), O-ethyl N,N-dimethylphosphoramidocyanidate (tabun or GA), cyclohexyl methylphosphonofluoridate (GF) and pinacolyl methylphosphonofluoridate (soman or GD) were acquired with a sampling cone voltage setting that promoted collisionally activated dissociation, and resulted in the acquisition of informative mass spectra containing both molecular and product ion information. The developed method appears to be an attractive alternative to GC–MS for the analysis of aqueous samples containing organophosphorus chemical warfare agents and their hydrolysis products, since they may be analyzed directly without the need for additional sample handling.  相似文献   

4.
A packed capillary liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification of chemical warfare agents, their degradation products and related compounds in synthetic tabun samples and in soil samples collected from a former mustard storage site. A number of organophosphorus and organosulfur compounds that had not been previously characterized were identified, based on acquired high-resolution ESI-MS data. At lower sampling cone voltages, the ESI mass spectra were dominated by protonated, sodiated and protonated acetonitrile adducts and/or their dimers that could be used to confirm the molecular mass of each compound. Structural information was obtained by inducing product ion formation in the ESI interface at higher sampling cone voltages. Representative ESI-MS mass spectra for previously uncharacterized compounds were incorporated into a database as part of an on-going effort in chemical warfare agent detection and identification. The same samples were also analyzed by capillary column gas chromatography (GC)-MS in order to compare an established method with LC-ESI-MS for chemical warfare agent identification. Analysis times and full-scanning sensitivities were similar for both methods, with differences being associated with sample matrix, ease of ionization and compound volatility. GC-MS would be preferred for organic extracts and must be used for the determination of mustard and relatively non-polar organosulfur degradation products, including 1,4- thioxane and 1,4-dithiane, as these compounds do not ionize during ESI-MS. Diols, formed following hydrolysis of mustard and longer-chain sulfur vesicants, may be analyzed using both methods with LC-ESI-MS providing improved chromatographic peak shape. Aqueous samples and extracts would, typically, be analyzed by LC-ESI-MS, since these analyses may be conducted directly without the need for additional sample handling and/or derivatization associated with GC-MS determinations. Organophosphorus compounds, including chemical warfare agents, related compounds and lower volatility hydrolysis products may all be determined during a single LC-ESI- MS analysis. Derivatization of chemical warfare agent hydrolysis products and other compounds with hydroxyl substitution would be required prior to GC-MS analysis, giving LC-ESI-MS a definite advantage over GC-MS for the analysis of samples containing chemical warfare agents and/or their hydrolysis products.  相似文献   

5.
Desorption electrospray ionization (DESI) mass spectrometry is used for the selective and sensitive detection of trace amounts of explosives and chemical warfare agent simulants from ambient surfaces at distances of up to 3 meters from the mass spectrometer.  相似文献   

6.
Although nerve agent use is prohibited, concerns remain for human exposure to nerve agents during decommissioning, research, and warfare. Exposure can be detected through the analysis of hydrolysis products in urine as well as blood. An analytical method to detect exposure to five nerve agents, including VX, VR (Russian VX), GB (sarin), GD (soman), and GF (cyclosarin), through the analysis of the hydrolysis products, which are the primary metabolites, in serum has been developed and characterized. This method uses solid-phase extraction coupled with high-performance liquid chromatography for separation and isotopic dilution tandem mass spectrometry for detection. An uncommon buffer of ammonium fluoride was used to enhance ionization and improve sensitivity when coupled with hydrophilic interaction liquid chromatography resulting in detection limits from 0.3 to 0.5 ng/mL. The assessment of two quality control samples demonstrated high accuracy (101–105 %) and high precision (5–8 %) for the detection of these five nerve agent hydrolysis products in serum.  相似文献   

7.
A new analytical method based on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) is proposed and validated for the identification and quantification of alkyl alkylphosphonic acids (AAPAs) in aqueous matrices. Retrospective detection and identification of degradation products of chemical warfare agents is important as an indicator of possible use of chemical warfare agents or of environmental contamination. A commercially available solution of 1,9‐nonanediyl‐bis‐(3‐methylimidazolium)bisfluoride (NBMI) allowed detection of AAPAs by positive mode electrospray ionization mass spectrometry by forming an adduct with AAPAs. MS/MS experiments using an ion trap analyzer were carried out for unambiguous identification of AAPAs. Different parameters were optimized in order to obtain both an adequate chromatographic separation and a high sensitivity using experimental design methodology. Quantification was done with matrix‐matched calibration standards of AAPAs. The method was validated in terms of linearity (r2 >0.982), intra‐ and inter‐day precisions (RSD below 15%), and robustness. The method is sensitive enough for the determination of AAPAs in aqueous matrices, with limits of detection in the 1–5 ng mL–1 range and limits of quantification in the 5–20 ng mL–1 range. Finally, the method was successfully applied to determine these AAPAs in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during 26th and 29th official proficiency tests. The added advantage of this method is identification of low mass range analyte at high mass range, which obviates the background noise at low mass range. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
The gingerols, including [6]-, [8]-, and [10]-gingerols, a series of chemical homologs differentiated by the length of their unbranched alkyl chains, have been identified as major active components in fresh ginger rhizome. The purpose of this study was to investigate the utility of ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) as an online tool to identify and quantify these compounds in raw or processed ginger rhizome samples. Negative mode electrospray ionization (ESI) was used in MS, MS/MS and MS(n) experiments in quadrupole ion trap instruments from two different manufacturers and in high-resolution and accurate mass MS and MS/MS experiments in a Fourier transform ion cyclotron resonance mass spectrometer to elucidate the ionization and fragmentation mechanisms of these compounds in these instruments. Positive mode ESI, which generated many more fragment ions in full scan MS even under gentle ionization conditions, was also used in LC/MS and MS/MS experiments and in direct infusion MS and MS/MS experiments. Consistent and predictable ionization and fragmentation behaviors were observed for all gingerols when analyzed in the same instrument. Instruments from different manufacturers, however, had different ionization mechanisms. The major difference between instruments was their ability to form covalent dimer adducts of the gingerols. Subsequent fragmentation patterns of the precursor ions were essentially identical. These results clearly demonstrate that LC/MS instruments produce data that cannot necessarily be replicated in other laboratories, especially if those laboratories do not have the same instrument model from the same manufacturer. This presents major problems for metabolite target analysis, metabolic profiling and metabolomics investigations, which would benefit from LC/MS mass spectrum libraries as they do from GC/MS mass spectrum libraries, because such libraries may not be valid across platforms.  相似文献   

9.
Desorption electrospray ionization (DESI) is implemented on a portable mass spectrometer and used to demonstrate in situ detection of active ingredients in pharmaceutical preparations, alkaloids in plant tissues, explosives, chemical warfare agent simulants and agricultural chemicals from a variety of surfaces; air monitoring applications using DESI are also introduced.  相似文献   

10.
A method to enhance the signal intensity and signal-to-noise of several alkyl methylphosphonic acids in negative electrospray ionization liquid chromatography tandem mass spectrometry (ESI LC-MS/MS) is presented. This class of compound represents the initial metabolites and environmental degradants of the nerve agents: VX, rVX (Russian VX), GB (Sarin), GF (Cyclosarin), and GD (Soman). Compared with the post-column addition of the mobile phase, the post-column addition of aprotic solvents and longer chain alcohols enhance the signal intensity and signal-to-noise ratio (S/N) of the chromatographic peaks by factors of up to 60 and 19, respectively. The post-column addition of water, methanol, and ethanol resulted in little or no relative signal enhancement. It is proposed that the post-column addition of these solvents do not result in the same enhancements due to stabilization of analyte solvation through hydrogen bonding.  相似文献   

11.
Sulfur mustard (HD), bis(2-chloroethyl)sulfide, is one of a class of mustard agents which are chemical warfare agents. The main chemical warfare hydrolysis degradation products of sulfur mustards are: thiodiglycol, bis(2-hydroxyethylthio)methane, 1,2-bis(2-hydroxyethylthio)ethane, 1,3-bis(2-hydroxyethylthio)propane, and 1,4-bis(2-hydroxyethylthio)butane. The aim of this study is to identify these five hydrolysis degradation products utilizing reversed-phase high-performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (ICP-MS) for element-specific sulfur detection using a collision/reaction cell and electrospray ionization mass spectrometry to confirm the identification. To date, this is the first study utilizing ICP-MS with 32S element-specific detection for the analysis of vesicant chemical warfare agent degradation products.  相似文献   

12.
液相色谱-电喷雾串联质谱法测定生姜中的215种农药残留   总被引:5,自引:1,他引:4  
曹静  庞国芳  王明林  范春林 《色谱》2010,28(6):579-589
建立了生姜中215种农药多残留测定的液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)方法。样品用1%醋酸-乙腈溶液均质提取,经Sep-Pak Vac固相萃取柱净化,乙腈-甲苯(3:1, v/v)洗脱,旋转蒸发浓缩至约0.5 mL后,于室温氮气吹干,用乙腈-水(3:2, v/v)溶解,以电喷雾电离串联质谱在正离子多反应监测(MRM)模式下进行测定。在定量限水平进行添加回收率实验,方法的回收率范围为68.1%~132.6%,其中回收率在70%~120%的占94.4%,相对标准偏差(RSD)范围为0.4%~25.0%。方法的检出限(S/N=3)和定量限(S/N=10)范围分别为0.01~70.45 μg/L和0.04~234.84 μg/L。该方法操作简便,灵敏度、准确度和精密度均符合农药多残留检测技术要求,适用于生姜中215种农药多残留的快速测定。  相似文献   

13.
The chemical/biological (CB) threat spectrum encompasses a wide range of potential agents including chemical warfare agents, biological warfare agents and toxins of biological origin that fall between these two main agent categories. These proteinaceous and non-proteinaceous toxins, commonly referred to as mid-spectrum agents, range in molecular mass from a few hundred to more than a hundred thousand daltons. The large number of potential candidates as well as the structural diversity of possible mid-spectrum agents makes identification of these compounds a challenge. The NATO defense community has recognized these challenges and has a working group that is developing identification protocols and evaluating methods through a series of international analytical exercises. Identification strategies rely heavily on recent advances that have been made in both mass spectrometry (MS) and liquid chromatography (LC), with LC-MS typically being employed as the primary method for separation/identification. While this paper focuses on the application of these and related instrumental analytical techniques for the identification of mid-spectrum agents, the approach described could be applied in the fields of toxicology, forensic science and environmental analysis. Areas for future research have been identified and application of developed mid-spectrum identification methods to the ongoing biological and toxin weapons convention (BTWC) are anticipated.  相似文献   

14.
Ageing products of a commercial jet engine oil based on pentaerythritol tetraesters which were formed upon operation in an aviation turbine were detected by electrospray ionization mass spectrometry (ESI-MS) and characterized by LC-ESI-MS. The fatty acid composition of these ageing products was investigated by ESI-MS-MS analysis. The ammonium adducts of the newly formed pentaerythritol tetraester degradation products were found to be suitable parent ions for further structure elucidation work. ESI-MS, LC-ESI-MS and ESI-MS-MS proved to be versatile tools to study the chemical composition (distribution of homologues) as well as the mechanism of ageing of ester based lubricants on a molecular level. Due to its high sensitivity, ESI-MS can also be used to characterize and identify trace levels of ester-based lubricants.  相似文献   

15.
The retrospective detection and identification of degradation products of chemical warfare agents are of immense importance in order to prove their spillage and use. A highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method--using an imidazolium-based tricationic reagent--was developed for the detection and identification of the anionic degradation products of nerve agents. A commercially available solution of 1,3-imidazolium-bis-(1-hexylbenzylimidazolium) trifluoride (IBHBI) formed adducts with alkylphosphonic acids (APAs), allowing detection of the APAs by positive mode ESI-MS. Tandem mass spectrometry was used for the unambiguous identification of the APAs. Parameters influencing the formation and stability of these adduct during mass spectrometric analysis, such as solvent composition, concentration of IBHBI, effect of pH and interferences by salts, were optimized. The absolute limits of detection (0.1 ng) for achieved for the APAs were better than those previously reported, and linear dynamic ranges of 10-2000 ng mL(-1) were achieved. The method was repeatable with a relative standard deviation ≤7.3%. APAs present in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during the 22(nd) and 24(th) Official Proficiency tests were detected and identified as IBHBI adducts. The added advantage of this method is that low-mass analytes are detected at higher mass, thus obviating the problem with background noise at low mass.  相似文献   

16.
The mass spectrometric (MS) and tandem mass spectrometric (MS/MS) behavior of six nitrocatechol-type glucuronides using atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was systematically studied, and the effect of operation parameters on the fragmentations are presented. The positive ion APCI- and ESI-MS spectra showed an intense protonated molecule and the respective negative ion spectra a deprotonated molecule with minimal fragmentation. The main fragment ions in the MS/MS spectra of the protonated and deprotonated molecules were [M + H - Glu]+ and [M - H - Glu]-, respectively, formed by the loss of the glucuronide moiety. The measured limits of detection indicated that ESI is a significantly more efficient ionization method than APCI in the negative and positive ion modes for the compounds studied. MS/MS was found to be less sensitive, but more reliable and simple than MS due to the absence of chemical noise.  相似文献   

17.
The collection of a low vapor pressure chemical simulant triethyl phosphate sorbed onto silica gel (TEP/SG) from a surface with subsequent analysis of the TEP/SG particulates using desorption electrospray ionization–mass spectrometry (DESI–MS) is described. Collection of TEP/SG particulates on a surface was accomplished using a sticky screen sampler composed of a stainless steel screen coated with partially polymerized polydimethylsiloxane (PDMS). DESI–MS analysis of TEP/SG particulates containing different percentages of TEP sorbed onto silica gel enabled the generation of response curves for the TEP ions m/z 155 and m/z 127. Using the response curves the calculation of the mass of TEP in a 25 wt% sample of TEP/SG was calculated, results show that the calculated mass of TEP was 14% different from the actual mass of TEP in the sample using the m/z 127 TEP ion response curve. Detection limits for the TEP vapor and TEP/SG particulates were calculated to be 4 μg and 6 particles, respectively.  相似文献   

18.
An analytical method based on aqueous ultrasonic extraction and packed capillary liquid chromatography-electrospray mass spectrometry (LC-ESI-MS) analysis was developed and compared to an existing gas chromatography(GC)-MS based method for the determination of sarin, soman and their hydrolysis products in contaminated soil. Three soils, a red clay, a tan sandy clay and a brown sandy clay loam, were spiked with sarin and soman and their initial hydrolysis products, isopropyl methylphosphonic acid and pinacolyl methylphosphonic acid, at the 10 microg/g level to assess recovery efficiency. Recovery of sarin and soman from the aqueous soil extracts was comparable to the existing analytical method, with a significant improvement in recovery being demonstrated for the chemical warfare agent hydrolysis products. Sarin and soman were recovered in the 20-90% range from the three soil types with aqueous extraction, while the hydrolysis products of these chemical warfare agents were extracted with recoveries in excess of 80%. The developed soil extraction and analysis method appears to be an attractive alternative to the GC-MS based method, since aqueous extracts containing chemical warfare agent hydrolysis products may be analysed directly, eliminating the need for additional sample handling and derivatization steps.  相似文献   

19.
Selenium speciation by HPLC with tandem mass spectrometric detection   总被引:2,自引:0,他引:2  
An HPLC/MS-MS method was developed for the analysis of selenium species. Tandem mass spectrometry (MS-MS) was chosen as a detector to provide structural and molecular information allowing the identification of species, which are not commercially available as standards. A new separation method for selenium species was developed, based on porous graphitic carbon (PGC) as the stationary phase. The applicability of the optimized HPLC/MS-MS system was demonstrated by the analysis of a mixture containing Se-methyl-selenocysteine, selenomethionine, selenocystine, selenoethionine and selenocystamine. All peaks were baseline-resolved and eluted within 16 min. Positive ionization led to higher intensities than negative ionization. Signal suppression tests showed that electrospray ionization (ESI) is a more effective ionization method than atmospheric pressure chemical ionization (APCI) for selenium species in a matrix containing pentafluoropropionic acid, heptafluorobutyric acid or ammonium formate. Comparative experiments with a triple quadrupole mass spectrometer (Quattro LC) and a time-of-flight instrument (Q-Tof-2) showed a 20 fold higher mass resolution of the latter mass spectrometer (m/Am= 5000) and significantly lower intensities for analyte signals as well as background noise compared to the triple quadrupole instrument. MS-MS spectra of the investigated selenium species including characteristic fragmentation patterns are presented.  相似文献   

20.
Forensic applications of ambient ionization mass spectrometry   总被引:1,自引:0,他引:1  
This review highlights and critically assesses forensic applications in the developing field of ambient ionization mass spectrometry. Ambient ionization methods permit the ionization of samples outside the mass spectrometer in the ordinary atmosphere, with minimal sample preparation. Several ambient ionization methods have been created since 2004 and they utilize different mechanisms to create ions for mass-spectrometric analysis. Forensic applications of these techniques—to the analysis of toxic industrial compounds, chemical warfare agents, illicit drugs and formulations, explosives, foodstuff, inks, fingerprints, and skin—are reviewed. The minimal sample pretreatment needed is illustrated with examples of analysis from complex matrices (e.g., food) on various substrates (e.g., paper). The low limits of detection achieved by most of the ambient ionization methods for compounds of forensic interest readily offer qualitative confirmation of chemical identity; in some cases quantitative data are also available. The forensic applications of ambient ionization methods are a growing research field and there are still many types of applications which remain to be explored, particularly those involving on-site analysis. Aspects of ambient ionization currently undergoing rapid development include molecular imaging and increased detection specificity through simultaneous chemical reaction and ionization by addition of appropriate chemical reagents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号