首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
流动注射在线萃取-火焰原子吸收法测定食用盐中的锌   总被引:1,自引:0,他引:1  
基于锌与 1 (2 吡啶偶氮 ) 2 萘酚 (简称PAN)形成的配合物可被氯仿萃取 ,从高盐基体样品中分离富集锌 ,利用自行设计的分相器 ,实验确定了最佳的流动注射在线萃取 火焰原子吸收光度法测定锌的流路系统和化学反应条件。在选定的工作条件下 ,其RSD和检出限分别为 4 3 % (c=0 6 μg/mL ,n =1 1 )和0 0 3 μg/mL ,测定速度为 2 5样 /h。用于实际样品的测定 ,加标回收率为 97%~1 0 6 %。  相似文献   

2.
Pohl P  Prusisz B  Zyrnicki W 《Talanta》2005,67(1):155-161
Metalfix Chelamine chelating resins of two different bead sizes (150-300 and 40-80 μm) were examined and compared regarding their application for sorption of Au, Ir, Pd, Pt, Rh and Ru ions from medium of HCl, HNO3 and mixtures of HCl and HNO3. The quantitative enrichment of Au, Ir, Pd and Pt was established for the resin of 150-300 μm particle size and for solutions acidified with HCl and HNO3 (3:1) up to the concentration of 0.50 mol l−1. In the case of Rh and Ru, the uptake of these metals by the resin was lower than 50%. For the elution, solutions of different reagents, i.e. HCl, HNO3, KCN, KI, KSCN and (NH2)2CS, were studied with respect to the complete release of the analytes retained by the resin. In addition, influence of various base metals, i.e. Al, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn, on the retention of the noble metals was investigated. Under the selected conditions for the retention and elution of Au, Ir, Pd and Pt, the analytical performance of the proposed pre-concentration procedure was evaluated and it was applied to the determination of these noble metals in anodic sludge sample.  相似文献   

3.
In this work, the microsampling nature of tungsten coil electrothermal vaporization Ar/H2 flame atomic fluorescence spectrometry (W-coil ETV-AFS) as well as tungsten coil electrothermal atomic absorption spectrometry (W-coil ET-AAS) was used with cloud point extraction (CPE) for the ultrasensitive determination of cadmium in rice and water samples. When the temperature of the extraction system is higher than the cloud point temperature of the selected surfactant Triton X-114, the complex of cadmium with dithizone can be quantitatively extracted into the surfactant-rich phase and subsequently separated from the bulk aqueous phase by centrifugation. The main factors affecting the CPE, such as concentration of Triton X-114 and dithizone, pH, equilibration temperature and incubation time, were optimized for the best extract efficiency. Under the optimal conditions, the limits of detection for cadmium by W-coil ETV-AFS and W-coil ET-AAS were 0.01 and 0.03 μg L−1, with sensitivity enhancement factors of 152 and 93, respectively. The proposed methods were applied to the determination of cadmium in certified reference rice and water samples with analytical results in good agreement with certified values.  相似文献   

4.
The effective preconcentration of submicrogram amounts of nickel from water is described. Nickel is extracted into xylene as a dithiocarbamate complex and subsequently back-extracted into 100 μl of nitric acid for graphite furnace atomic absorption spectrometry. Conditions for quantitative extraction and back-extraction are described. Data on interferences, precision and detection limits are presented. Sub-μg 1?1 levels of nickel in water could be determined with concentration factors of 500–1000 by the proposed method. The concentrations of nickel in rain water and surface snow were found to be 0.39 and 0.19 μg 1?1, respectively. The limit of determination can be lowered by using concentration factors larger than 104, nickel determination at ng 1?1 levels being feasible.  相似文献   

5.
Procedures for the electrothermal atomic absorption spectrometric determination of lead and cadmium in urine, serum and blood are developed. For serum and blood, the samples are diluted by incorporating 0.015% (w/v) Triton X-100 and 0.1% (w/v) ammonium dihydrogenphosphate to the solutions, which are then introduced directly into the furnace. A solution containing 15% (w/v) hydrogen peroxide and 0.65% (w/v) nitric acid is also introduced into the atomizer by means of a separate injection. Zeeman-based correction is recommended. Both conventional and fast-heating programs are discussed. Calibration is carried out using the standard additions method. The reliability of the procedures is checked by analyzing three certified reference materials and by recovery studies.  相似文献   

6.
The concentrations of heavy metals in the soil, mushroom and plant samples collected from Tokat, Turkey have been determined by flame and graphite furnace atomic absorption spectrometry after dry ashing, wet ashing and microwave digestion. The study of sample preparation procedures showed that the microwave digestion method was the best. Good accuracy was assured by the analysis of standard reference materials. The relative standard deviations for all measured metal concentrations were lower than 10%. In all cases, quantitative analytical recoveries ranging from 95 to 103% were obtained. Metal accumulation factors were calculated for mushroom and plant samples. High ratio of plants to soil cadmium, zinc and copper concentrations indicate that these elements are accumulated by mushrooms. Results obtained are in agreement with data reported in the literature.  相似文献   

7.
Methods for the determination of aluminium and manganese in human scalp hair samples by electrothermal atomic absorption spectrometry using the slurry sampling technique were developed. Palladium and magnesium nitrate were used as chemical modifiers. Hair samples were pulverized using a zirconia vibrational mill ball, and were prepared as aqueous slurries. Determinations can be performed in the linear ranges of 1.9–150 μg l−1 Al3+ and 0.03–10.0 μg l−1 Mn2+. Limits of detection of 0.9 mg kg−1 and 27.6 μg kg−1 were obtained for aluminium and manganese, respectively. The analytical recoveries were between 99.6 and 101.8% for aluminium and in the 98.3–101.3% range for manganese. The repeatability of the methods (n=11), slurry preparation procedure and ETAAS measurement, was 16.0 and 7.9% for aluminium and manganese, respectively. The methods were finally applied to the aluminium and manganese determination in 25 scalp hair samples from healthy adults. The levels for aluminium were between 8.21 and 74.08 mg kg−1, while concentrations between 0.03 and 1.20 mg kg−1 were found for manganese.  相似文献   

8.
A rapid method for the determination of Pb, Cd, Cu, Cr, Co, Ni, Mn and Zn in honey and sugars without prior digestion or ashing of the sample was developed, using inductively coupled plasma atomic emission spectrometry (ICP-AES). The critical instrumental parameters such as sample flow rate and radio frequency incident power were thoroughly optimized. The effect of matrix type and its concentration was also examined for glucose/fructose, sucrose and honey matrices. The sensitivity was investigated using calibration curves obtained in presence of the above matrices. The obtained recoveries for Cd, Cu, Cr, Co, Ni and Mn at the μg l−1 level were satisfactory and practically independent of the matrix used for the calibration standards. The recoveries of Pb and Zn were less sufficient. Various commercial samples of honey, sugar, glucose and fructose were analyzed with respect to their toxic metal content. The method can be applied for routine analysis, quality and environmental pollution control purposes at the μg l−1 level of concentration, after suitable dilution of the samples.  相似文献   

9.
Two digestion-free methods for trace analysis of boron nitride based on graphite furnace atomic absorption spectrometry (GFAAS) and electrothermal vaporization inductively coupled plasma spectrometry optical emission (ETV-ICP-OES) using direct solid sampling have been developed and applied to the determination of Al, Ca, Cr, Cu, Fe, Mg, Mn, Si, Ti and Zr in four boron nitride materials in concentration intervals of 1–23, 54–735, 0.05–21, 0.005–1.3, 1.6–112, 4.5–20, 0.03–1.8, 6–46, 38–170 and 0.4–2.3 μg g− 1, respectively. At optimized experimental conditions, with both methods, effective in-situ analyte/matrix separation was achieved and calibration could be performed using calibration curves measured with aqueous standard solutions. In solid sampling GFAAS, before sampling, the platform was covered with graphite powder and, for determination of Si, also the Pd/Mg(NO3)2 modifier was used. In the determination of all analyte elements by solid sampling ETV-ICP-OES, Freon R12 was added to argon carrier gas. For solid sampling GFAAS and ETV-ICP-OES, the achievable limits of detection were within 5 (Cu)–130 (Si) ng g− 1 and 8 (Cu)–200 (Si) ng g− 1, respectively. The results obtained by these two methods for four boron nitride materials of different purity grades are compared each with the other and with those obtained in analysis of digests by ICP-OES. The performance of the two solid sampling methods is compared and discussed.  相似文献   

10.
The analytical conditions for the determination of thallium by graphite furnace atomic absorption spectrometry were studied and optimized using the peak-height mode. The charring-atomization curves for thallium from different atomization surfaces were constructed and the optimum charring and atomization conditions were established. These atomization surfaces included pyrolytic graphite-, tantalum-, zirconium- and tungsten-coated graphite tubes. The effects of different inorganic acids on the absorbance of thallium from different surfaces were studied. Using tungsten carbide-coated tubes, the interference effects due to hydrochloric and perchloric acids were eliminated. The matrix modification technique was also investigated for increasing the maximum permissible charring temperature for thallium. The matrix modifiers used included tungsten, zirconium, nickel and tantalum. The effect of adding these modifiers were studied in the presence of different acids. Tungsten increased the maximum permissible charring temperature from 400 to 1000 °C.  相似文献   

11.
12.
Two methods available for direct determination of total Fe in seawater at low concentration level have been examined: electrothermal atomization atomic absorption spectrometry (ETAAS) and electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS). In a first part, we have optimized experimental conditions of ETAAS (electrothermal program, matrix chemical modification) for the determination of Fe in seawater by minimizing the chemical interference effects and the magnitude of the simultaneous background absorption signal. By using the best experimental conditions, a detection limit of 80 ng L−1 (20 μL, 3σ) for total Fe concentration was obtained by ETAAS. Using similar experimental conditions (electrothermal program, chemical modification), we have optimized experimental conditions for the determination of Fe by LEAFS. The selected experimental conditions for ETA-LEAFS: excitation wavelength (296.69 nm), noise attenuation and adequate background correction led to a detection limit (3σ) of 3 ng L−1 (i.e. 54 pM) for total Fe concentration with the use a 20 μL seawater sample. For the two methods, concentration values obtained for the analysis of Fe in a NASS-5 (0.2 μg L−1) seawater sample were in good agreement with the certified values.  相似文献   

13.
An alternative, simple and rapid technique was developed for a quantitative isolation of the group of eight elements: Al, Ca, Cd, Cu, Fe, Mg, Pb and Zn from vegetable material samples in an open system with the use of acids: conc. HCl, dil. HNO3 and hydrofluoric acids. Equivalence of both the extractants, HCl and HNO3, was found suitable for a quantitative isolation of Ca, Cu, Mg, Zn, Pb and Cd. For lead and cadmium, however, dil. HNO3 proved to be more suitable because these elements are determined by the graphite furnace atomic absorption spectrometry (GF-AAS) technique. A quantitative dissolution of Al and Fe requires hydrofluoric acid as an additional extractant. The proposed method allows to obviate the organic matrix destruction stage, shorten the analyte dissolution time, reduce cost, and minimize hazards of loss and contamination. Validity and versatility of the method developed was verified by the analysis of standard reference materials.  相似文献   

14.
Different chemical modifiers for use with electrothermal atomic absorption spectrometry (ET AAS) were investigated in relation to determining the selenium in human urine samples. The samples were diluted in a solution containing 1% v/v HNO3 and 0.02% m/v cetyltrimethylammonium chloride (CTAC). Studying the modifiers showed that the use of either Ru or Ir as the permanent modifier gave low sensitivity to Se and the peak shape was very noisy, while Zr or Rh gave no peak at all. The same occurred when Zr was used in solution. For mixtures of permanent modifiers, Ir plus Rh or Zr plus Rh gave very low sensitivity, Zr plus Rh with co-injection of Ir in solution was also not efficient, Zr plus Rh in solution gave good sensitivity, but the best results were obtained with a mixture of Zr and Rh as the permanent modifier and co-injection of Rh in solution. Using this last modifier, the following dilutions with the HNO3 and CTAC were studied: 1:1, 1:2, 1:3 and 1:4. The best dilution was 1:1, which promoted good sensitivity and a more defined peak shape and made it possible to correct for the background using a deuterium arc lamp. Under these conditions, a characteristic mass of 26±0.2 pg was obtained for Se in aqueous solution. Six certified urine samples were analyzed using matrix matching calibration and the measured concentrations were in agreement with the certified values, according to a t-test at the 95% confidence level. Recovery tests were carried out and the recoveries were in the range 100–103%, with relative standard deviation better than 9%. The limit of detection (LOD, 3 sd, n=10) was 3.0 μg L−1 in the sample. The treated graphite tube could be used for at least 600 atomization cycles without significant alteration of the analytical signal.  相似文献   

15.
The reversible sorption preconcentration of noble metals (NMs) using different schemes “sorbent–reagent–eluent” was investigated. The extraction of Au, Pd, Pt, Ir, Rh and Ru chlorocomplexes from hydrochloric acid solutions on hyper-crosslinked polysterene MN-200 in the form of ion associates with tributylamine (TBA) and 4-(n-octyl)diethylenetriamine (ODETA) was investigated. It was found that Pd, Pt and Au were quantitatively and reversibly extracted using TBA on hyper-crosslinked polysterene; the appropriate eluent for desorption was 1 M solution of HCl in ethanol. Ir, Rh and Ru under these conditions were not sorbed quantitatively. It was found that sorbent hydrophobicity is not the main characteristic that defines the efficiency of sorption of a particular NM ion associate. Different efficiencies of hyper-crosslinked polysterene MN-200 for sorption of square-planar chlorcomplexes of Pt, Pd and Au and octahedral complexes of Ir, Rh and Ru were found. For the first time, the sorbents with their own N-atoms – StrataX and StrataX-AW – were used for the sorption of Ir, Rh and Ru. Using these sorbents, the sorption of Ir was increased up to 95%, and the sorption of Ru and Rh was increased to about 40%. We can explain these results by nonspecific interaction of chlorcomplexes of Ir, Rh and Ru with ethylenediamine groups of the sorbent. Weak bases with large anions may be applied for desorption of Ir, Rh and Ru. Two schemes of dynamic sorption preconcentration of NMs from hydrochloric acid solutions were proposed – hyper-crosslinked polysterene MN-200 for the determination of Au, Pd, Pt, and StrataX-AW for Ir, Rh and Ru.  相似文献   

16.
原子吸收和原子荧光光谱分析   总被引:1,自引:0,他引:1  
本文是《分析试验室》期刊定期评述中关于原子吸收光谱(AAS)及原子荧光光谱(AFS)分析的第11篇综述文章. 文中对2004年12月~2007年4月期间我国在AAS/AFS领域所取得的主要进展进行评述. 内容包括概述、仪器装置与数据处理、火焰原子吸收光谱法、电热原子吸收光谱法、化学蒸气发生技术以及原子荧光光谱法等. 收集文献670篇.  相似文献   

17.
As is apparent from the literature devoted to the analytical atomic spectrometry, chemical vapor generation (CVG) of noble metals by reaction with tetrahydroborate in acidic media may enhance the introduction of these elements into different atomic spectrometric sources. Recent developments in the CVG of noble metals species by reaction with tetrahydroborate in acidic medium are surveyed. Different aspects of this novel technique are discussed, including type of instrumentation used for the reaction, separation and transport of the species, effect of chemical and physical factors, identification of the species, and the efficiency of the process. Limitations and future prospects of the CVG technique are discussed.  相似文献   

18.
Mierzwa J  Sun YC  Chung YT  Yang MH 《Talanta》1998,47(5):35-1270
The comparative determination of barium, copper, iron, lead and zinc in tea leaf samples by two atomic spectrometric techniques is reported. At first, slurry sampling electrothermal atomization atomic absorption spectrometry (ETAAS) was applied. The results of Ba and Pb determination were calculated using the method of standard additions, and results of Cu, Fe and Zn from the calibration graphs based on aqueous standards. These results were compared with the results obtained after microwave-assisted wet (nitric+hydrochloric+hydrofluoric acids) digestion in closed vessels followed by inductively coupled plasma-atomic emission spectrometric (ICP-AES) determination with the calibration by means of aqueous standards. The exception was lead determined after a wet digestion procedure by ETAAS. The accuracy of the studied methods was checked by the use of the certified reference material Tea GBW-07605. The recoveries of the analytes varied in the range from 91 to 99% for slurry sampling ETAAS, and from 92.5 to 102% for liquid sampling ICP-AES. The advantages of slurry sampling ETAAS method are simplicity of sample preparation and very good sensitivity. Slurry sampling ETAAS method is relatively fast but if several elements must be determined in one sample, the time of the whole microwave-assisted digestion procedure and ICP-AES determination will be shorter. However, worse detection limits of ICP-AES must also be taken into the consideration in a case of some analytes.  相似文献   

19.
20.
The transition metals ions Cr(III), Mn(II), Fe(III), Co(II), Ni(II), and Zn(II) in addition to Ca(II) have been used as modifiers in the determination of silicon using electrothermal Zeeman atomic absorption spectrometry. Co(II) proved to be the best. Graphite tubes treated with zirconium, in the presence of Co(II) as a modifier, exhibit higher sensitivity by a factor of five than untreated tubes. The modifier concentration and ashing and atomization temperatures have been optimized. Also interference of different inorganic cations and anions was studied.  相似文献   