首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
Owing to no complications caused by solid supports, such as adsorptive sample loss and deactivation, tailing of solute peaks, and contamination, countercurrent chromatography (CCC) has been an area of intense research since the first introduction of CCC in 1970,[1] and various apparatus and broad applications have been advanced[2,3]. For these developments, the type-J synchronous planet centrifuge has received considerable attention, which relies not only on its relatively simple mechanic design, but also on its high partition efficiency and short elution time caused by mixing and settling for the efficient chromatographic separations. In the past, however, almost all of type-J centrifuges rotated slowly were disposed horizontally due to the original design and some experiments that gravis plays an important role at a low rotary speed as similar to type-V rotating multilayer helical tube in unit gravity[4-9]. In fact,we discovered that the upright apparatus holds more retention of stationary phase than the horiziontal aparatus when large standard tubings were used as mutilayer coil column and the aparatus was operated under same contions. We report here a new coil planet centrifuge with four upright cylindrical columns for large scale countercurrent chromatographic preparation. The design principle and apparatus of UCCC is as samilar to type-J multilayer coil planet centrifuge. Four uptight cylindrical column holders are symmetrically arranged around the centrifuge axis as similar to the type-J HSCCC with three horizontal multilayer coils connected in series[8] . A series of experiments indicat that upright CCC has many advantages over the horizontal CCC when using a large-bore tube as multilayer coil column for large scale countercurrent chromatographic separation.Upright CCC provide a versatile countercurrent chromatographic method for large-scale preparation from very crude sample. It has good preparative capacity and flexible suitability to various sample and two-phase system.The present apparatus not only can be operated at a high speed as similar as commonly used HSCCC for the system having short settling time and but also can be run at a low speed for the system having relative long settling time. Because of automatical control and seal-free flow through device, the uptight CCC apparatus may be readily scaled up to industrial preparation.  相似文献   

2.
Comparing the performance of different counter-current chromatography (CCC) J-type centrifuges has and will always be difficult. This is due to the number of variables such as speed of rotation, swung radius, β-value, column bore, column length that can be chosen during the design of an instrument. This situation is further complicated by the implication that some of these variables are intrinsically linked, such that if one is changed another or others can also change. The chromatographer has no influence on these hardware parameters once the instrument designer has chosen them. However, the chromatographer wants a CCC column that retains the most liquid stationary phase in order to achieve the best separation of the components in a mixture. What matters most is column performance in terms of: sample loading per injection, speed of separation, purity of target and yield of target. The instrument that has the best performance in all these areas is called a “high-performance” CCC system. This paper demonstrates to the modern chromatographer that a “high-performance” CCC instrument has shorter, lower volume columns that are rotated faster to provide quicker separations, even with the same sample loading.  相似文献   

3.
An important advance in countercurrent chromatography (CCC) carried out in open flow-tubing coils, rotated in planetary centrifuges, is the new design to spread out the tubing in spirals. More spacing between the tubing was found to significantly increase the stationary phase retention, such that now all types of two-phase solvent systems can be used for liquid-liquid partition chromatography in the J-type planetary centrifuges. A spiral tubing support (STS) frame with circular channels was constructed by laser sintering technology into which FEP tubing was placed in 4 spiral loops per layer from the bottom to the top and a cover affixed allowing the tubing to connect to flow-tubing of the planetary centrifuge. The rotor was mounted and run in a P.C. Inc. type instrument. Examples of compounds of molecular weights ranging from <300 to approximately 15,000 were chromatographed in appropriate two-phase solvent systems to assess the capability for separation and purification. A mixture of small molecules including aspirin was completely separated in hexane-ethyl acetate-methanol-water. Synthetic peptides including a very hydrophobic peptide were each purified to a very high purity level in a sec-butanol solvent system. In the STS rotor high stationary phase retention was possible with the aqueous sec-butanol solvent system at a normal flow rate. Finally, the two-phase aqueous polyethylene glycol-potassium phosphate solvent system was applied to separate a protein from a lysate of an Escherichia coli expression system. These experiments demonstrate the versatility of spiral CCC using the STS rotor.  相似文献   

4.
Counter-current chromatography (CCC) works with a support-free liquid stationary phase. This allows for preparative separations and purifications. However, there are serious technical constraints because of the need to keep a liquid stationary phase in a column. Centrifugal fields are used. A new commercial hydrodynamic 18 mL column made with a narrow-bore 0.8 mm Teflon tubing was evaluated by comparing it with older hydrodynamic CCC columns and a similar 19 mL column but made with 1.6 mm Teflon tubing. A small-volume CCC column allows for reliable and fast solute partition coefficient determination. When resolution is required, both high efficiency and liquid stationary phase retention are needed. Unfortunately, these two requirements bear technical contradictions. A column coiled with a narrow tubing bore will provide a high chromatographic efficiency while a column containing wider tubing bore will achieve higher stationary phase retention. In all cases, increasing the magnitude of the centrifugal field also increases the stationary phase retention. The solution is to build centrifuges able to produce high fields that will provide acceptable liquid phase retention with narrow-bore tubes. The new 18 mL 0.8 mm tubing bore column is able to rotate as fast as 2100 rpm generating a 240 × g field. The two older CCC columns cannot compete with the new one. However, the small 19 mL column with 1.6 mm bore tubing can be useful when fast results are desired without top resolution.  相似文献   

5.
The dispersion behavior of solutes was investigated in a rotating flowing coiled tube. Potassium iodide, tartrazine, ascorbic acid, lysozyme, bovine serum albumin (BSA), and silver nanoparticle (AgNPs) samples were eluted in a coiled tube of counter-current chromatography (CCC) apparatus with a single phase. Apparent convection peaks of low-diffusivity solutes appeared in the static CCC tube, while Gaussian-like peaks showed up for the high-diffusivity solutes. When the rotation speed of the CCC apparatus was elevated, all solute peak widths became smaller, and the convection peaks of AgNPs and BSA were minimized and formed Gaussian-like peaks. The axial dispersions of all solutes were reduced owing to the higher radial mass transfer in the rotating CCC column. The same reasoning could also be used to rationalize other special band shapes encountered in two-phase CCC separations.  相似文献   

6.
This paper addresses the technological readiness of counter-current chromatography (CCC) instruments to become platform technology for the pharmaceutical industry. It charts the development of the prototype technology since its inception in 1966, through conceptual improvements in the 1980s that led to higher speed separations in hours as opposed to days. It then describes the engineering improvements that have led to the development of high performance counter-current chromatography with the potential for scale-up to process scale for manufacturing products in industry with separation times in minutes rather than hours. A new UK Technology Strategy Board high value manufacturing £1.5 m research programme to take CCC through to technology readiness level 8 (i.e. as platform technology for continuous 24 × 7 operation by industry) is introduced. Four case studies are given as examples of successes from its expanding applications portfolio, which is mainly confidential. Finally, the hurdles for the uptake of new technology by industry are highlighted and the following potential solutions given: rapid method development, automation, continuous processing and instrument reliability and robustness. The future challenge for the CCC community will be to address these development needs urgently if CCC is to become the platform technology it deserves to be.  相似文献   

7.
Countercurrent chromatography (CCC) is a support-free liquid-liquid chromatography using centrifugal fields to hold the liquid stationary phase. CCC has been widely applied in the separation of various natural and synthetic components using a variety of biphasic liquid systems. The related hexane or heptane/ethyl acetate/methanol or ethanol/water biphasic liquid systems demonstrated their significance in CCC. Gradient is difficult in CCC since any composition change in one phase induces a composition change of the other phase to maintain phase equilibrium. This work provides a new insight into linear gradient elution in CCC that is feasible with some biphasic liquid systems such as selected compositions of the hexane/ethyl acetate/ethanol/water systems. The equations modeling solute motion inside the CCC column are proposed. Particular compositions of the liquid system, namely the hexane/ethyl acetate/ethanol/water 8:2:E:W compositions with E + W = 10, were studied from W = 1 to 9. They showed moderate changes in the upper organic phase compositions. The model is tested with the separation of tanshinones from the rhizome of Salvia miltiorrhiza Bunge. Different linear solvent gradient profiles were experimentally performed between 8:2:5:5 and 8:2:3:7 compositions and the results were evaluated using the proposed model. Five tanshinones including dihydrotanshinone I, cryptotanshinone, tanshinone I, 1,2-dihydrotanshinquinone, and tanshinone IIA have been successfully separated (>95% purities) using a gradient profile optimized by the developed model. The gradient model can be used only with biphasic liquid systems in which one phase shows minimum composition changes when the other phase composition changes notably. This case is not the general case for biphasic liquid systems but can be applied with specific compositions of the quaternary hexane or heptane/ethyl acetate/methanol or ethanol/water most useful CCC liquid systems.  相似文献   

8.
Peng A  Li R  Hu J  Chen L  Zhao X  Luo H  Ye H  Yuan Y  Wei Y 《Journal of chromatography. A》2008,1200(2):129-135
In this paper, high-speed counter-current chromatography (HSCCC) instruments with different gravitational forces were applied for the separation of bioactive compounds from Triperygium wilfordii Hook.f. The critical parameters including sample concentration, sample volume and flow rate were first optimized on an analytical Mini-DE HSCCC system, and then scaled up to a preparative TBE 300A HSCCC system. Although this scale-up process was performed using different CCC instruments with different centrifuges and gravitational forces, the same resolutions were obtained and the elution time could be predictable. Five diterpenoid compounds and one unknown compound were separated from Triperygium wilfordii Hook.f. by HSCCC with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (HEMW) (3:2:3:2, v/v/v/v). This one-step flow gradient separation produced triptonide (25 mg), isoneotriptophenolide (77 mg), hypolide (83 mg), unknown compound (1 mg), triptophenolide (42 mg), triptonoterpene methyl ether VI (37 mg) from 320 mg crude extract with purities of 98.2%, 96.6%, 98.1%, 95.3%, 95.1%, and 96.5%, respectively. Their purities and structures were identified by high-performance liquid chromatography, mass spectrometry and NMR. This paper demonstrates that analytical CCC plays an important role in optimizing parameters and scale-up process when analytical CCC and preparative CCC are supplied by different manufacturers with different gravitational forces, and the scale-up process from analytical CCC to preparative CCC is still predictable.  相似文献   

9.
Muehlenbeckia volcanica (Benth.) Endl. (M. volcanica), native to South America, is a traditional Peruvian medicinal plant that has multi-therapeutic properties; however, no phytochemicals have been identified from it yet. In this study, a five-step polarity-stepwise elution counter-current chromatography (CCC) was developed using methanol/water (1:5, v/v) as the stationary phase and different ratios of n-hexane, ethyl acetate, and n-butanol as mobile phases to separate the compounds from the 70% methanol extract of M. volcanica, by which six compounds with a wide range of polarities were separated in a single run of CCC and were identified as gallic acid, protocatechuic acid, 4,4′-dihydroxy-3,3′-imino-di-benzoic acid, rutin, quercitrin, and quercetin. Then, two compounds from the fractions of stepwise elution CCC were separated using conventional high-speed CCC, pH-zone-refining CCC, and preparative high-performance liquid chromatography, and identified as shikimic acid and miquelianin. These compounds are reported from M. volcanica for the first time. Notably, except for shikimic acid, all other compounds showed anti-diabetic potentials via antioxidant, antiglycation, and aldose reductase inhibition. The results suggest that the polarity-stepwise elution CCC can be used to efficiently separate or fractionate compounds with a wide range of polarities from natural products. Moreover, M. volcanica and its bioactive compounds are potent anti-diabetic agents.  相似文献   

10.
Liang J  Yang Z  Cao X  Wu B  Wu S 《Journal of chromatography. A》2011,1218(36):6191-6199
In this work, we have established a new stop-and-go two-dimensional chromatography coupling of counter-current chromatography and liquid chromatography (2D CCC × LC) for the preparative separation of two novel antioxidant flavonoids from the extract of alfalfa (Medicago sativa L.). The CCC column has been used as the first dimension to purify the target flavonoids using a solvent system of isopropanol and 20% sodium chloride aqueous solution (1:1, v/v) with the stop-and-go flow technique, and the LC column packed with macroporous resin has been employed as the second dimension for on-line absorption, desalination and desorption of the targeting effluents purified from the first CCC dimension. As a result, two novel flavonoids, 6,8-dihydroxy-flavone-7-O-β-D-glucuronide (15.3 mg) and 6-methoxy-8-hydroxy-flavone-7-O-β-D-glucuronide (13.7 mg), have been isolated from 126.8 mg of crude sample pre-enriched by macroporous resin column. Their structures have been identified by electrospray ionization mass spectrometry (ESI-MS), electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) and one- and two-dimensional nuclear magnetic resonance spectra (1D and 2D NMR). Further antioxidant assays showed that the first component possess a strong antioxidant activity. All the results demonstrated that the stop-and-go 2D CCC × LC method is very efficient for the separation of flavonoids of alfalfa and it can also be applied to isolate other comprehensive multi-component natural products.  相似文献   

11.
In this work, we have developed a novel hybrid two-dimensional counter-current chromatography and liquid chromatography (2D CCC × LC) system for the continuous purification of arctiin from crude extract of Arctium lappa. The first dimensional CCC column has been designed to fractionalize crude complex extract into pure arctiin effluent using a one-component organic/salt-containing system, and the second dimensional LC column has been packed with macroporous resin for on-line adsorption, desalination and desorption of arctiin which was effluent purified from the first CCC dimension. Thus, the crude arctiin mixture has been purified efficiently and conveniently by on-line CCC × LC in spite of the use of a salt-containing solvent system in CCC separation. As a result, high purity (more than 97%) of arctiin has been isolated by repeated injections both using the ethyl acetate–8% sodium chloride aqueous solution and butanol–1% sodium chloride aqueous solution. By contrast with the traditional CCC processes using multi-component organic/aqueous solvent systems, the present on-line CCC × LC process only used a one-component organic solvent and thus the solvent is easier to recover and regenerate. All of used solvents such as ethyl acetate, n-butanol and NaCl aqueous solution are low toxicity and environment-friendly. Moreover, the lower phase of salt-containing aqueous solution used as mobile phase, only contained minor organic solvent, which will save much organic solvent in continuous separation. In summary, our results indicated that the on-line hybrid 2D CCC × LC system using one-component organic/salt-containing aqueous solution is very promising and powerful tool for high-throughput purification of arctiin from fruits of A. lappa.  相似文献   

12.
Unlike the existing 2-D pseudo-ring model for helical columns undergoing synchronous type-J planetary motion of counter-current chromatograph (CCC), the 3-D "helix" model developed in this work shows that there is a second normal force (i.e. the binormal force) applied virtually in the axial direction of the helical column. This force alternates in the two opposite directions and intensifies phase mixing with increasing the helix angle. On the contrary, the 2-D spiral column operated on the same CCC device lacks this third-dimensional mixing force. The (principal) normal force quantified by this "helix" model has been the same as that by the pseudo-ring model. With β>0.25, this normal centrifugal force has been one-directional and fluctuates cyclically. Different to the spiral column, this "helix" model shows that the centrifugal force (i.e. the hydrostatic force) does not contribute to stationary phase retention in the helical column. Between the popular helical columns and the emerging spiral columns for type-J synchronous CCC, this work has thus illustrated that the former is associated with better phase mixing yet poor retention for the stationary phase whereas the latter has potential for better retention for the stationary phase yet poor phase mixing. The methodology developed in this work may be regarded as a new platform for designing optimised CCC columns for analytical and engineering applications.  相似文献   

13.
Experimental excess isotherms for the adsorption of gases in porous solids may be represented by mathematical models that incorporate the total amount of gas within a pore, a quantity which cannot easily be found experimentally but which is important for calculations for many applications, including adsorptive storage. A model that is currently used for hydrogen adsorption in porous solids has been improved to include a more realistic density profile of the gas within the pore, and allows calculation of the total amount of adsorbent. A comparison has been made between different Type I isotherm equations embedded in the model, by examining the quality of the fits to hydrogen isotherms for six different nanoporous materials. A new Type I isotherm equation which has not previously been reported in the literature, the Unilan-b equation, has been derived and has also been included in this comparison study. These results indicate that while some Type I isotherm equations fit certain types of materials better than others, the T?th equation produces the best overall quality of fit and also provides realistic parameter values when used to analyse hydrogen sorption data for a model carbon adsorbent.  相似文献   

14.
15.
I-type, J-type and non-synchronous centrifuges are all coil planet centrifuges. Analysing the motion of I-type and J-type centrifuges has advanced the understanding of how to manufacture and use these centrifuges. This paper analyses the motion of non-synchronous centrifuges producing equations of motion that can be applied to all coil planet centrifuges. This has also produced simple equations to determine the critical β-values for any coil planet centrifuge. This paper also demonstrates that I-type centrifuges also have 2 critical β-values when it was thought that β-value did not influence the understanding of the processes within I-type centrifuges. For the I-type instrument both of these critical values are at bobbin radii approaching infinity. In practice this means all I-types function within one β-value range hence the unilateral distribution and type/effectiveness of the mixing is consistent. Finally the paper shows the influence that the tangential velocity has on the Archimedean screw effect and thus the unilateral distribution of the upper and lower phases in the columns of coil planet centrifuges. This explains why the maximum stationary phase retention in an I-type centrifuge is limited to 50%.  相似文献   

16.
This review focuses on the growing popularity of using counter-current chromatography (CCC), with its liquid stationary phase, as one of the prime methods for isolating compounds from Chinese herbal medicines (CHMs). 198 publications are reviewed covering 108 different plant species from 56 plant families. These describe the isolation of 354 different molecules across a wide range of polarities, chemical classes and molecular weights (in the range 100–1000 Da). The suitability of CCC for the separation of active compounds from CHM, the phase systems used, how CCC has developed in China, compounds isolated, CCC instrumentation, performance, operational issues and innovations, all supported by detailed cross-referencing, are described. It is concluded that CCC is making an increasingly important contribution to the modernisation of Chinese herbal medicines.  相似文献   

17.
An explicit linear sixth algebraic order six-step method with vanished phase-lag and its first derivative is constructed in this paper. We will study the method theoretically and computationally. Theoretical investigation contains the building of the method, the calculation of the local truncation error, the comparative error analysis of the new method with the method with constant coefficients and the stability analysis of the new method using scalar test equation with different frequency than the frequency of the scalar test equation used for the development of the method. Computational investigation contains the application of the new obtained linear six-step method to the resonance problem of the radial time independent Schrödinger equation. The theoretical and computational study lead us to the summary that the new proposed linear scheme is computationally and theoretically more efficient than other well known methods for the numerical solution of the Schrödinger equation and related periodic initial or boundary value problems.  相似文献   

18.
Flavonoids form a large class of important naturally occurring bioactive compounds. Their isolation and purification from natural sources can sometimes be very difficult and time‐consuming when traditional phytochemical techniques are used. Countercurrent chromatography (CCC), a support‐free liquid–liquid partition chromatography technique, is very useful for the isolation of polar compounds and its use is increasing in the natural products field. In this paper, we propose strategies of solvent system selection for the isolation of flavonoids by CCC, based on data from the literature, plus incorporation of own practical experiences. The selected references report the isolation of over 300 different flavonoid compounds from more than 100 plant species, using 40 different solvent systems, showing the versatility of this technique. The solvent system hexane‐ethylacetate‐methanol‐water is proposed as a starting point for the separation of samples containing free flavonoids, as it was cited in more than 60% of the papers. A “fine tuning” step is proposed at each level of this solvent family. Other modifications include exchanging the alcohol in the system as well as introducing a fifth solvent. The solvent system ethyl‐acetate‐butanol‐water is proposed as the starting point for glycosylated flavonoids. Other solvent systems are also discussed. The use of gradients is proposed for samples containing both free and glycosylated flavonoids, as the polarity window is larger in these cases. High‐speed countercurrent chromatography was used in 89% of the reviewed data.  相似文献   

19.
Since 1980, high-speed counter-current chromatography (HSCCC) has been used for separation and purification of natural and synthetic products in a standard elution mode. In 1991, a novel elution mode called pH-zone refining CCC was introduced from an incidental discovery that an organic acid in the sample solution formed the sharp peak of an acid analyte. The cause of this sharp peak formation was found to be bromoacetic acid present in the sample solution which formed a sharp trailing border to trap the acidic analyte. Further studies on the separation of DNP-amino acids with three spacer acids in the stationary phase revealed that increased sample size resulted in the formation of fused rectangular peaks, each preserving high purity and zone pH with sharp boundaries. The mechanism of this phenomenon was found to be the formation of a sharp trailing border of an acid (retainer) in the column which moves at a lower rate than that of the mobile phase. In order to facilitate the application of the method, a new method was devised using a set of retainer and eluter to form a sharp retainer rear border which moves through the column at a desired rate regardless of the composition of the two-phase solvent system. This was achieved by adding the retainer in the stationary phase and the eluter in the mobile phase at a given molar ratio. Using this new method the hydrodynamics of pH-zone-refining CCC was diagrammatically illustrated by three acidic samples. In this review paper, typical pH-zone-refining CCC separations were presented, including affinity separations with a ligand and a separation of a racemic mixture using a chiral selector in the stationary phase. Major characteristics of pH-zone-refining CCC over conventional HSCCC are as follows: the sample loading capacity is increased over 10 times; fractions are highly concentrated near saturation level; yield is improved by increasing the sample size; minute charged compounds are concentrated and detected at the peak boundaries; and elution peaks are monitored with a pH flow meter for compounds with no chromophore. Since 1994, over 70 research papers on pH-zone-refining CCC have been published with the trends increasing in the recent years.  相似文献   

20.
A new general equation of state recently reported for pure liquids has been developed to predict the volumetric and thermodynamic properties of six binary and two ternary liquid refrigerant mixtures (including HCs and HFCs mixtures) at different temperatures, pressures, and compositions. The results show this equation of state can be used to reproduce and predict different thermodynamic properties of liquid refrigerant mixtures within experimental errors. The composition dependence of the parameters of this equation of state has been assumed as quadratic functions of mole fraction. Using these mixing rules, the agreement between calculated and experimental densities is better than 0.6% for binary mixtures and 2.3% for ternary mixtures. To compare the performance of this new equation of state against other well-known methods such as the COSTALD method, the density of some refrigerant mixtures, for which the parameters of COSTALD were available, has been computed and compared with those of this new equation of state.  相似文献   