首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We have investigated the accuracy and reproducibility of DNA quantitation on the DNA Lab-Chip and the relationship of these to the size and concentration of the DNA fragments. We found that quantitation of small DNA fragments, i.e. less than 200 bp, suffers from high relative error which can be improved by using an internal standard of similar size to the sample. The effects of trace chloride ion on quantitation error and sensitivity of the DNA Lab-Chip were also studied, and it was revealed that 0.2 mM chloride ion reduces quantitation sensitivity by 30% and increases the relative error. We also studied the effects of purification on quantitation errors in analysis of PCR products from cloning vector pUC118 and showed that use of an unpurified sample reduces chip sensitivity by 25%.Dedicated to Professor K. Jinno on the occasion of his 60th birthday.Revised: 9 December 2004 and 17 January 2005  相似文献   

2.
Johirul M  Shiddiky A  Kim RE  Shim YB 《Electrophoresis》2005,26(15):3043-3052
A microfluidic chip based on capillary electrophoresis coupled with a cellulose-single-stranded DNA (cellulose-ssDNA) modified electrode was used for the simultaneous analysis of dopamine (DA), norepinephrine (NE), 3,4-dihydroxy-L-phenylalanine (L-DOPA), 3,4-dihydroxyphenylacetic acid (DOPAC), and ascorbic acid (AA). The modification of the electrode improved the electrophoretic analysis performance by lowering the detection potential and enhancing the signal-to-noise characteristic without surface poisoning of the electrode. The sensitivity of the modified electrode was about 12 times higher than those of the bare ones. The test compounds were separated using a 62 mm long separation channel at the separation field strength of +200 V/cm within 220 s in a 10 mM phosphate buffer (pH 7.4). The most favorable potential for the amperometric detection was 0.7 V (vs. Ag/AgCl). A reproducible response (relative standard deviation of 1.3, 1.3, 2.1, 3.1, 3.4% for DA, NE, L-DOPA, DOPAC, and AA, respectively, for n = 9) for repetitive sample injections reflected the negligible electrode fouling at the cellulose-ssDNA modified electrode. Square-wave voltammetric analyses reflected the sensitivities of the modified electrode for DA, NE, L-DOPA, DOPAC, and AA which were 1.78, 0.82, 0.69, 2.45, and 1.23 nC/microM with detection limits of 0.032, 0.93, 1.13, 0.31, and 0.62 microM, respectively. The applicability of this microsystem to real sample analysis was demonstrated.  相似文献   

3.
A new method for mass fabrication of silver ink conductivity detector electrodes for poly(methylmethacrylate) (PMMA) microchip electrophoretic systems has been developed based on screen‐printing technology. Printing of silver conductivity electrodes was performed through a patterned stencil on thin PMMA sheets. Following the electrode fabrication, the PMMA sheets are cut into cover sheets, and are aligned and sealed to the channel plate thus establishing a complete microchip separation device. The effects of the electrode width and spacing on the response and resolution have been investigated and the optimized electrode performance was compared to commonly used aluminum electrodes in the determination of ammonium, methyl ammonium, and sodium. The utility of the screen‐printed contactless conductivity detector (SPCCD) electrodes is further demonstrated for the separation and detection of organic acids with excellent reproducibility (RSD values of 3.7% and 4.1% for oxalate and tartrate, respectively). The thick‐film fabrication of the electrode material demonstrates the ability to mass‐fabricate detection devices with total process of device fabrication requiring less than 4 h (including the fabrication of channel plate, cover sheet with the electrodes, and subsequent bonding). The fabrication method described here is convenient and does not compromise the detector performance, hence offers great promise for producing single use field deployable analytical microsystems.  相似文献   

4.
《Electroanalysis》2005,17(13):1153-1159
The fabrication and evaluation of pyrolyzed photoresist films (PPF) for microchip capillary electrophoresis (CE) with dual‐electrode electrochemical (EC) detection is described. The sensitivity, linearity, and reproducibility were evaluated using catecholamines and related compounds, including dopamine (DA), 5‐hydroxyindole‐3‐acetic acid (5‐HIAA), ascorbic acid (AA), and catechol. Initial studies with DA show the response of the PPF electrodes to be linear between 25 and 500 μM (r2=0.999) with a limit of detection (LOD) of 5 μM (S/N=3) and sensitivity of 5.8 pA/μM. Selectivity was further enhanced by employing dual‐electrode detection in the series configuration for detection of species exhibiting chemically reversible redox reactions.  相似文献   

5.
Shin D  Tryk DA  Fujishima A  Muck A  Chen G  Wang J 《Electrophoresis》2004,25(17):3017-3023
The attractive features of a boron-doped diamond (BDD) thin-film detector for microchip capillary electrophoretic (CE) separations of dye-related amino-substituted aromatic compounds are described. The diamond electrode was employed in the end-column amperometric detection of 4-aminophenol (4-AP), 1,2-phenylenediamine (1,2-PDA), 2-aminonaphthalene (2-AN), 2-chloroaniline (2-CA), and o-aminobenzoic acid (o-ABA), and its attractive behavior was compared to commonly used screen-printed carbon and glassy-carbon electrodes. These conventional electrode materials exhibit a significant degree of passivation and low sensitivity to the above-mentioned environmental pollutants. The diamond-based electrochemical detection system displayed a favorable analytical performance, including lower noise levels, higher peak resolution with enhanced sensitivity, and improved resistance against electrode passivation. Factors influencing the on-chip analysis were assessed and optimized. The diamond detector displayed detection limits of 2.0 and 1.3 microM for 4-AP and 2-AN, respectively, and a wide linear response for these compounds over the 2-50 microM range. The enhanced stability was demonstrated by relative standard deviation (RSD) values of 1.4% and 4.7% for 100 microM 1,2-PDA and 200 microM 2-CA, respectively, for repetitive detections (n = 7). Besides, the simultaneously observed current decrease was 2.4 and 9.1% for 1,2-PDA and 2-CA, respectively (compared to 21.8 and 41.0% at the screen-printed carbon electrode and 28.3 and 34.1% at the glassy carbon electrode, respectively). The favorable properties of the diamond electrode indicate great promise for environmental applications in CE and other microchip devices.  相似文献   

6.
We report the development of a hand-held instrument capable of performing two simultaneous microchip separations (gel and zone electrophoresis), and demonstrate this instrument for the detection of protein biotoxins. Two orthogonal analysis methods are chosen over a single method in order to improve the probability of positive identification of the biotoxin in an unknown mixture. Separations are performed on a single fused-silica wafer containing two separation channels. The chip is housed in a microfluidic manifold that utilizes o-ring sealed fittings to enable facile and reproducible fluidic connection to the chip. Sample is introduced by syringe injection into a septum-sealed port on the device exterior that connects to a sample loop etched onto the chip. Detection of low nanomolar concentrations of fluorescamine-labeled proteins is achieved using a miniaturized laser-induced fluorescence detection module employing two diode lasers, one per separation channel. Independently controlled miniature high-voltage power supplies enable fully programmable electrokinetic sample injection and analysis. As a demonstration of the portability of this instrument, we evaluated its performance in a laboratory field test at the Defence Science and Technology Laboratory with a series of biotoxin variants. The two separation methods cleanly distinguish between members of a biotoxin test set. Analysis of naturally occurring variants of ricin and two closely related staphylococcal enterotoxins indicates the two methods can be used to readily identify ricin in its different forms and can discriminate between two enterotoxin isoforms.  相似文献   

7.
The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration adjustment takes place when the sample components migrate into the chip during the sample loading step. Using a heart-cutting method, a diluted sample plug is subsequently separated with capillary zone electrophoresis. The excessive dispersion that is typical of the samples with a high ionic strength is thereby prevented. The method can be easily applied to commercially available capillary electrophoresis microchips under the condition that the electroosmotic flow is suppressed. For the first time the lithium concentration is determined in the blood plasma from a patient on lithium therapy without sample pretreatment. Using a microchip with conductivity detection, a detection limit of 0.1 mmol/L is obtained for lithium in a 140 mmol/L sodium matrix.  相似文献   

8.
Kang SH  Park M  Cho K 《Electrophoresis》2005,26(16):3179-3184
We evaluated a novel strategy for fast diagnosis by microchip electrophoresis (ME), using programmed field strength gradients (PFSG) in a conventional glass double-T microfluidic chip. The ME-PFSG allows for the ultrafast separation and enhanced resolving power for target DNA fragments. These results are based on electric field strength gradients (FSG) that use an ME separation step in a sieving gel matrix poly-(ethylene oxide). The gradient can develop staircase or programmed shapes FSG over the time. The PFSG method could be easily used to increase separation efficiency and resolution in ME separation of specific size DNA fragments. Compared to ME that uses a conventional and constantly applied electric field (isoelectrostatic) method, the ME-PFSG achieved about 15-fold faster analysis time during the separation of 100 bp DNA ladder. The ME-PFSG was also applied to the fast analysis of the PCR products, 591 and 1191 bp DNA fragments from the 18S rRNA of Babesia gibsoni and Babesia caballi.  相似文献   

9.
芯片毛细管电泳电化学检测   总被引:1,自引:0,他引:1  
吴友谊  林金明 《化学通报》2004,67(3):170-177
评述了芯片毛细管电泳各种电化学检测尤其是安培检测中工作模式、工作电极、分离电流的消除、应用等方面的进展,并进行了展望。  相似文献   

10.
We report on the coupling of a polymer-based microfluidic chip to a MALDI-TOF MS using a rotating ball interface. The microfluidic chips were fabricated by micromilling a mold insert into a brass plate, which was then used for replicating polymer microparts via hot embossing. Assembly of the chip was accomplished by thermally annealing a cover slip to the embossed substrate to enclose the channels. The linear separation channel was 50 microm wide, 100 microm deep, and possessed an 8 cm effective length separation channel with a double-T injector (V(inj) = 10 nL). The exit of the separation channel was machined to allow direct contact deposition of effluent onto a specially constructed rotating ball inlet to the mass spectrometer. Matrix addition was accomplished in-line on the surface of the ball. The coupling utilized the ball as the cathode transfer electrode to transport sample into the vacuum for desorption with a 355 nm Nd:YAG laser and analyzed on a TOF mass spectrometer. The ball was cleaned online after every rotation. The ability to couple poly(methylmethacrylate) microchip electrophoresis devices for the separation of peptides and peptide fragments produced from a protein digest with subsequent online MALDI MS detection was demonstrated.  相似文献   

11.
螺旋通道微流控PCR芯片连续自动扩增DNA片段的研究   总被引:3,自引:0,他引:3  
研制了由内向外流动的螺旋通道微流控PCR玻璃芯片,减少了PCR反应液在微通道中流动时的分散和阻力;讨论了扩增循环数和进样速度对长片段基因扩增的影响,在26min内成功扩增了质量浓度仅为10ng/mL的6012bpλ-DNA;通过将小孔径石英毛细管作为顺序注射(SI)系统的连接管路,使其死体积降到0.30μL.实现了微升级样品的自动换样、连续PCR扩增和微通道洗涤等功能.样品间无交叉污染.每小时可扩增500bpλ-DNA试样7个.扩增产物片段大小和荧光强度的相对标准偏差分别为0.4%和6.7%.  相似文献   

12.
We performed a series of multi‐locus PCRs followed by the rapid and efficient microchip electrophoretic sorting of Alu products with LIF detection. Five polymorphic human‐specific Alu insertions (RC5, A1, PV92, TPA and ACE) were used for inference of human ethnicity and two monomorphic Alu insertions for sex typing, one fixed on the X chromosome (AluSTXa) and the other on the Y chromosome (AluSTYa). These markers were used to generate unique DNA profiles for five different DNA samples. The PCR‐based assays used primers that flank the insertion point to determine genotypes based on the presence or absence of the Alu element. A1, RC5, PV92, TPA and ACE were used for ethnicity determinations and have two alleles, each indicating the presence (+) or absence (?) of the Alu element on the paired chromosomes, which results in three genotypes (+/+, +/? or ?/?). RC5 and A1 did not show ethnic heterogeneity resulting in a homozygous (?/?) genotype, which correctly inferred that DNA samples originating from a Caucasian male and an Asian male were not of African ancestry. The results from the five Alu markers indicated that these Alu loci could assist in identifying the individual's ethnicity using microchip electrophoresis in under 15 min of separation time. Using microchip electrophoresis and mixed genotype ratios, male DNA‐to‐female DNA of 1:9, corresponding to a ratio of Y‐to‐X chromosomes of 1:19, was also detected for both AluSTXa and AluSTYa to provide gender identification without requiring separation of female from male cells prior to the assay.  相似文献   

13.
Escalating threats of terrorist activity have led to urgent demands for innovative devices for on-site detection of chemical and biological agents and explosive materials. Field detection of such hazardous substances requires that a powerful analytical performance be coupled to miniaturized low-powered instrumentation. “Lab-on-a-Chip” devices, where liquids are manipulated in a microchannel network, offer great promise for converting large and sophisticated instruments into powerful field-deployable analyzers. Particularly attractive for on-site security applications is the very small footprint of microchip devices, high degree of integration, high performance, fast response, and versatility. This article reviews a variety of microchip-based protocols and devices for detecting terrorist weapons. Such microfluidic devices offer great promise for transporting the forensic laboratory to the sample source, and providing an early warning prior to terrorist activity, or a rapid post-analysis ‘fingerprints’ of a disaster site. Due to the small footprint of microchip devices, it could be possible to perform multiple assays simultaneously. Such prospects, challenges and applications are discussed.  相似文献   

14.
利用芯片毛细管电泳管道中电渗流的数学模型,模拟了正常管道和细管道中十字交叉进样电渗流的性质以及其中样品浓度的分布.模拟的结果与文献报道一致.引人了时间参数,对电渗流以及浓度的分布作了一个含时的考察.同时,提出了通过管道表面修饰改变ζ电势的方法以消除弯道效应.  相似文献   

15.
We describe a new and selective analytical method for the separation and quantitation of plant glucosinolates. The new method, which utilizes microchip CE (micro-CE) with fluorescence detection, circumvents the multistep procedures characteristic of conventional methods. Glucosinolates form charge transfer complexes with the xanthene dyes phloxine-B and eosin-B. The glucosinolates-phloxine-B complex cannot be excited at 470 nm. Thus, the decrease in peak intensity of phloxine-B after complex formation is used to quantitatively measure total glucosinolates in Arabidopsis thaliana seeds. For qualitative analysis, complex formation with eosin-B is used. The sensitivity of eosin-B detection at excitation/emission 470 nm/540 nm was low. However, sensitivity increased following complex formation with sinigrin (> or =3 microg/mL). A batch-learning, self-organizing map was applied to visualize and organize analytical data into 2-D matrix with similar and related data clustered together or near each other. This organized matrix was used to optimize electrophoretic conditions for the analysis. This study suggests potential applications of micro-CE in plant metabolomics analyses without use of labeling fluorophores.  相似文献   

16.
The aggregation and adhesion of bacterial cells is a serious disadvantage for electrophoretic separations of bacteria. In this study, lipid-based liquid crystalline nanoparticles were used as a pseudostationary phase to minimise the bacterial aggregation and adsorption to the inner walls of microchannels. Lactobacillus delbrueckii subsp. bulgaricus, Streptococcus thermophilus and Lactobacillus rhamnosus were selected as analytes and were separated by microchip electrophoresis (MCE) with laser-induced fluorescence (LIF) detection using 4.5 mM tris(hydroxymethyl) aminomethane (TRIS)-4.5 mM boric acid-0.1 mM ethylenediaminetetraacetate (EDTA) (TBE) containing poly(ethylene oxide) (PEO) and lipid-based nanoparticles as the running buffer. The mechanism of lipid-based nanoparticles affecting bacterial adhesion and aggregation was discussed and supported by zeta potential experiments. Under the optimal conditions, the three species of bacteria were identified with patterned peaks. This proposed MCE method using lipid-based nanoparticles as running buffer additives was also used to analyse a real yogurt sample, and valuable bacterial information was obtained by the electropherograms.  相似文献   

17.
A method to integrate a carbon microelectrode with a microfabricated palladium decoupler for use in microchip capillary electrophoresis (CE) is detailed. As opposed to previous studies with decouplers for microchip CE, the working electrode material, which is made by micromolding of a carbon ink, is different from the decoupling electrode material (palladium). The manner in which the working electrode is made does not add additional etching or lithographic steps to the fabrication of the glass electrode plate. The hybrid poly(dimethylsiloxane)/glass device was characterized with fluorescence microscopy and by monitoring the CE-based separation of dopamine. Hydrodynamic voltammograms exhibited diffusion-limited currents occurring at potentials above +1.0 V. It was also shown that the half-wave potential does not shift as the separation potential is changed, as is the case in nondecoupled systems. Gated injections of dopamine in a 25 mM boric acid buffer (pH 9.2) showed a linear response from 200 to 5 microM (r2 = 0.9992), with a sensitivity of 5.47 pA/microM and an estimated limit of detection of 2.3 microM (0.621 fmol, S/N = 3). This is the first report of coupling a carbon electrode with a decoupler in microchip CE.  相似文献   

18.
Lee HL  Chen SC 《Talanta》2004,64(1):210-216
Microchip capillary electrophoresis (μCE) with amperometric detection at Cu electrode benefited fast separation and direct detection of carbohydrates. The working electrode of 50-μm Cu wire attached nearly against the channel outlet—4 μm, where it benefited collecting detection current and suppressing overwhelming noise. The use of alkaline medium was essential to separating and detecting carbohydrates, which dissociated into the sensitive alcolate anions. The 10-cm serpentine chip, though lengthening the migration time, it provided better efficiency. Sucrose, cellobiose, glucose, and fructose migrated from the outlet in 400 s +2000 V. The linear calibration plots ranging from 10 to 1000 μM with regression coefficients better than 0.996 were obtained. The injection-to-injection reproducibility of 1.24% (n=7) for glucose in peak current and 0.6% for migration times were excellent. The detection limit was low, down to 2.3 μM for glucose (S/N=3) or 27.6 attomole in mass detection.  相似文献   

19.
提出用带有非接触电导检测的微芯片毛细管电泳法快速测定片剂中盐酸二甲双胍的含量。取盐酸二甲双胍片20片,剥除糖衣后混匀研细,称取0.100 0g,用水超声溶解、过滤,滤液定容至100mL供毛细管电泳分析。十字通道芯片使用前按规定进行清洗。试验中采用含5%(体积分数)乙醇和0.1mmol·L-1十二烷基磺酸钠的2.0mmol·L-1柠檬酸缓冲溶液作为分离介质,进时间为10.0s,分离电压为1.3kV,可在1min内实现分离和测定。盐酸二甲双胍的质量浓度在10.0~110.0mg·L-1范围内与相应峰高呈线性关系,检出限(3S/N)为1.0mg·L-1。应用此方法分析了3个片剂样品,并用标准加入法做回收试验,测得回收率在94.5%~103%之间,测定值的相对标准偏差(n=6)在0.63%~1.1%之间。  相似文献   

20.
电泳微芯片由于具有自动化程度高、试剂消耗少和分析速度快等优点,目前已经成为微全分析系统研究的热点.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号