首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 79 毫秒
1.
This work was performed with the aim of comparing protein adsorption results obtained from the recently developed dual polarization interferometry (DPI) with the well-established surface plasmon resonance (SPR) technique. Both techniques use an evanescent field as the sensing element but completely different methods to calculate the adsorbed mass. As a test system we used adsorption of the lipase from Thermomyces lanuginosus (TLL) on C18 surfaces. The adsorbed amount calculated with both techniques is in good agreement, with both adsorption isotherms saturating at 1.30–1.35 mg/m2 at TLL concentrations of 1000 nM and above. Therefore, this supports the use of both SPR and DPI as tools for studying protein adsorption, which is very important when comparing adsorption data obtained from the use different techniques. Due to the spot sensing in SPR, this technique is recommended for initial kinetic studies, whereas DPI is more accurate when the refractive index and thickness of the adsorbed layer is of more interest.  相似文献   

2.
Coatings based on dendritic polyglycerol (dPG) were investigated for their use to control nonspecific protein adsorption in an assay targeted to analyze concentrations of a specific protein. We demonstrate that coating of the sample vial with dPG can significantly increase the recovery of an antibody after incubation. First, we determine the concentration dependent loss of an antibody due to nonspecific adsorption to glass via quartz crystal microbalance (QCM). Complementary to the QCM measurements, we applied the same antibody as analyte in an surface plasmon resonance (SPR) assay to determine the loss of analyte due to nonspecific adsorption to the sample vial. For this purpose, we used two different coatings based on dPG. For the first coating, which served as a matrix for the SPR sensor, carboxyl groups were incorporated into dPG as well as a dithiolane moiety enabling covalent immobilization to the gold sensor surface. This SPR-matrix exhibited excellent protein resistant properties and allowed the immobilization of amyloid peptides via amide bond formation. The second coating which was intended to prevent nonspecific adsorption to glass vials comprised a silyl moiety that allowed covalent grafting to glass. For demonstrating the impact of the vial coating on the accuracy of an SPR assay, we immobilized amyloid beta (Aβ) 1-40 and used an anti-Aβ 1-40 antibody as analyte. Alternate injection of analyte into the flow cell of the SPR device from uncoated and coated vials, respectively gave us the relative signal loss (1 − RUuncoated/RUcoated) caused by the nonspecific adsorption. We found that the relative signal loss increases with decreasing analyte concentration. The SPR data correlate well with concentration dependent non-specific adsorption experiments of the analyte to glass surfaces performed with QCM. Our measurements show that rendering both the sample vial and the sensor surface is crucial for accurate results in protein assays.  相似文献   

3.
A surface plasmon resonance (SPR) sensor on a compact disk (CD)-type microfluidic device was developed to miniaturize the elements of a complete analytical system, pump and valves. The CD-type microfluidic device was fabricated by attaching a polydimethylsiloxane disk plate that contained microchannels and reservoirs to a flat polycarbonate disk plate that contained grating films with a thin layer of Au. The optical system of the SPR sensor and the theory for its operation are based on the principle of a grating coupled-type SPR. The sample and reagent solutions in the reservoirs on the CD-type microfluidic device were sequentially introduced into the detection chamber by centrifugal force generated by the rotation of the microfluidic device. The variation of resonance wavelength was dependent on the refractive index of the sample solution. This CD-type SPR sensor was successfully used in an immunoassay of immunoglobulin A (IgA). The anti-IgA, blocking reagent, sample and washing solution in the reservoirs were sequentially introduced into the detection chamber by changing the frequency of rotation of the microfluidic device. IgA in the sample solution was adsorbed to the anti-IgA immobilized on the Au thin layer in the detection chamber and was then detected by the SPR sensor.  相似文献   

4.
The objective of this study was to investigate the adsorption of fibronectin on titanium (Ti) surfaces and the effect of pre-adsorbed fibronectin on osteoblast precursor cell attachment in vitro. Two different concentrations of bovine fibronectin were used in this study. Protein adsorption on Ti surfaces was analyzed using the micro bicinchoninic acid (BCA) protein assay. Cell concentration on Ti and fibronectin pre-adsorbed Ti surfaces after 3 h incubation was analyzed using the Vybrant™ cell adhesion assay. Cell morphology on Ti and fibronectin pre-adsorbed Ti surfaces was observed using scanning electron microscopy (SEM). After 180 min incubation, maximum adsorption of bovine fibronectin on Ti surfaces was observed. Fibronectin adsorption on Ti surfaces was observed to be significantly dependent on the initial concentration and the amount of incubation time. In the presence of 1 mg/ml fibronectin pre-adsorbed on Ti surfaces after 15 min, osteoblast precursor cell attachment on Ti surfaces was observed to be enhanced compared with control Ti surfaces, Ti surfaces pre-adsorbed with 1 mg/ml fibronectin for 180 min, and Ti surfaces pre-adsorbed with 0.1 mg/ml fibronectin for 15 and 180 min. No significant difference in cell attachment was observed between control Ti surfaces, Ti surfaces pre-adsorbed with fibronectin for 180 min, and Ti surfaces pre-adsorbed with 0.1 mg/ml fibronectin for 15 and 180 min. In addition, no differences in cell morphology of the attached osteoblast precursor cells on control Ti surfaces and Ti surfaces pre-adsorbed with fibronectin were observed in this study. It was concluded that an optimum concentration of adsorbed fibronectin on Ti surfaces plays an important role in governing cell attachment.  相似文献   

5.
Surface properties have a significant influence on the performance of biomedical devices. The influence of surface chemistry on the amount and distribution of adsorbed proteins has been evaluated by a combination of atomic force microscopy (AFM) and surface plasmon resonance (SPR). Adsorption of albumin, fibrinogen, and fibronectin was analyzed under static and dynamic conditions, employing self-assembled monolayers (SAMs) as model surfaces. AFM was performed in tapping mode with antibody-modified tips. Phase-contrast images showed protein distribution on SAMs and phase-shift entity provided information on protein conformation. SPR analysis revealed substrate-specific dynamics in each system investigated. When multi-protein solutions and diluted human plasma interacted with SAMs, SPR data suggested that surface chemistry governs the equilibrium composition of the protein layer.  相似文献   

6.
In this work, we synthesized two MDI-based polyurethanes, including a poly(ether)urethane (PEU) and a poly(carbonate)urethane (PCU), by using different soft segments, poly(tetramethylene oxide) and poly(hexyl, ethyl)carbonate diol (M approximately 2,000). We demonstrated that, in addition to the enhanced biostability of PCU over PEU, the biological performances of PCU in vitro were also improved in general. These included, better cellular attachment and proliferation, less platelet activation, as well as reduced monocyte activation. The unusual wide-ranging enhancement in biocompatibility for PCU was believed to be related to the larger micro-phase separation in PCU (approximately 25 nm) that caused distinct protein adsorption on the surface. The total number of adherent monocytes (nonactivated and activated) on the bare sample surfaces, albumin pre-adsorbed sample surfaces, and fibrinogen pre-adsorbed sample surfaces.  相似文献   

7.
Chemical homogeneous poly(dimethylsiloxane) (PDMS) surface with dot-like protrusion pattern was used to investigate the individual effect of surface microtopography on protein adsorption and subsequent biological responses. Fibrinogen (Fg) and fibronectin (Fn) were chosen as model proteins due to their effect on platelet and cell adhesion, respectively. Fg labeled with 125I and fluorescein isothiocyanate (FITC) was used to study its adsorption on flat and patterned surfaces. Patterned surface has a 46% increase in the adsorption of Fg when compared with flat surface. However, the surface area of the patterned surface was only 8% larger than that of the flat surface. Therefore, the increase in the surface area was not the only factor responsible for the increase in protein adsorption. Clear fluorescent pattern was visualized on patterned surface, indicating that adsorbed Fg regularly distributed and adsorbed most on the flanks and valleys of the protrusions. Such distribution and local enrichment of Fg presumably caused the specific location of platelets adhered from platelet-rich plasma (PRP) and flowing whole blood (FWB) on patterned surface. Furthermore, the different combination of surface topography and pre-adsorbed Fn could influence the adhesion of L929 cells. The flat surface with pre-adsorbed Fn was the optimum substrate while the virgin patterned surface was the poor substrate in terms of L929 cells spread.  相似文献   

8.
We present intein-mediated approaches for efficient biotinylation of proteins site-specifically. The reactive C-terminal thioester generated from intein-assisted protein splicing (either in vitro or in live cells) served as an attractive and exclusive site for attaching cysteine-containing biotin. Using these novel biotinylation strategies, we were able to efficiently biotinylate many proteins from different biological sources in a potentially high-throughput, high-content fashion. Some of these proteins were subsequently immobilized, in a very simple manner, onto different avidin-functionalized solid surfaces for applications such as protein microarray and surface plasmon resonance (SPR) spectroscopy, highlighting the numerous advantages of using biotin over other tags (e.g., GST, His-tag, etc.) as the method of choice in protein purification/immobilization. In addition, our intein-mediated strategies provided critical advantages over other protein biotinylation strategies in a number of ways. For the first time, we also successfully demonstrated that intein-mediated protein biotinylation proceeded adequately inside both bacterial and mammalian living cells, as well as in a cell-free protein synthesis system. Taken together, our results indicate the versatility of these intein-mediated strategies for potential high-throughput proteomics applications. They may also serve as useful tools for various biochemical and biophysical studies of proteins both in vitro and in vivo.  相似文献   

9.
Highly sensitive detection of proteins in serum becomes difficult in some cases during surface plasmon resonance (SPR) measurements, because some ingredients in the serum hugely enhance non-specific reactions on the sensing chip of SPR. It is well recognized that the antibody against core protein p24 of HIV in serum is one of the most important proteins in the accurate diagnosis of infection with HIV. In this study, we could attain the accurate detection of anti p24 antibody in human serum by eliminating the serious effects of the ingredients in serum on the measurement of SPR by employing these procedures: 1) blocking the gold surface of the sensing chip with human serum and 2) heating the serum sample at 56 degrees C for 30 min. Without these treatments, the signal of SPR was considerably suppressed on the measurements of the anti p24 antibody which contained human serum, making the accurate detection difficult. However, with introducing the above two treatments, the sensing of anti p24 antibody in human serum was improved, while a small non-specific reaction was still observed. By removing the non-specific reaction caused by the ingredients in the serum, we could accurately measure the antibody for p24 in human serum sample over the range from 1 to 20 micrograms/ml.  相似文献   

10.
Wall adsorption is a common problem in microfluidic devices, particularly when proteins are used. Here we show how superhydrophobic surfaces can be used to reduce protein adsorption and to promote desorption. Hydrophobic surfaces, both smooth and having high surface roughness of varying length scales (to generate superhydrophobicity), were incubated in protein solution. The samples were then exposed to flow shear in a device designed to simulate a microfluidic environment. Results show that a similar amount of protein adsorbed onto smooth and nanometer-scale rough surfaces, although a greater amount was found to adsorb onto superhydrophobic surfaces with micrometer scale roughness. Exposure to flow shear removed a considerably larger proportion of adsorbed protein from the superhydrophobic surfaces than from the smooth ones, with almost all of the protein being removed from some nanoscale surfaces. This type of surface may therefore be useful in environments, such as microfluidics, where protein sticking is a problem and fluid flow is present. Possible mechanisms that explain the behaviour are discussed, including decreased contact between protein and surface and greater shear stress due to interfacial slip between the superhydrophobic surface and the liquid.  相似文献   

11.
12.
This paper describes the use of surface plasmon resonance (SPR) spectroscopy and self-assembled monolayers (SAMs) to understand the characteristics of surfaces that promote the adsorption of proteins at high ionic strengths (high-salt conditions). We synthesized SAMs presenting different multimodal ligands and determined the influence of surface composition, solution composition, and the nature of the protein on the extent of protein adsorption onto the SAMs. Our results confirm that hydrophobic interactions can contribute significantly to protein adsorption under high-salt conditions. In particular, the extent of protein adsorption under high-salt conditions increased with increasing surface hydrophobicity. The extent of protein adsorption was also influenced by the solution composition and decreased with an increase in the chaotropicity of the anion. The combination of SPR and SAMs is well-suited for studying the interaction of proteins with complex surfaces of relevance to chromatography.  相似文献   

13.
Plasma polymerized pyrrole-like (PPpy) films exhibit good environmental stability and offer high reactivity with biomolecules. The present paper follows on from previous work on PPpy films applied as DNA immobilization/hybridization and describes the adsorption kinetics of bovine serum albumin (BSA) on PPpy films. Atom force microscopy was used to detect the surface roughness of PPpy surfaces obtained at different input powers or for different polymerization time, including the surface roughness before and after BSA adsorption. The influence of experimental conditions (i.e., the plasma input power, the polymerization time, the concentration of BSA, and the pH values of buffer solutions) on protein adsorption was investigated in situ by Surface plasmon resonance spectroscopy (SPR). SPR analysis confirmed the differently dynamic adsorption behavior of BSA on PPpy films under various experimental conditions. The adsorption constant, K a , was deduced from Langmuir isotherm equations, which were simulated using experimental data collected by SPR and electrochemical impedance spectroscopy (EIS). Analysis of the combination data of SPR and EIS indicates that PPpy films under various conditions show completely different adsorption behaviors and could be applied as biomaterials for electrochemical protein sensing or as protein-resistant.   相似文献   

14.
Carbohydrates (glycans) and their conjugates with proteins and lipids contribute significantly to many biological processes. That makes these compounds important targets to be detected, monitored and identified. The identification of the carbohydrate content in their conjugates with proteins and lipids (glycoforms) is often a challenging task. Most of the conventional instrumental analytical techniques are time-consuming and require tedious sample pretreatment and utilising various labeling agents. Surface plasmon resonance (SPR) has been intensively developed during last two decades and has received the increasing attention for different applications, from the real-time monitoring of affinity bindings to biosensors. SPR does not require any labels and is capable of direct measurement of biospecific interaction occurring on the sensing surface. This review provides a critical comparison of modern analytical instrumental techniques with SPR in terms of their analytical capabilities to detect carbohydrates, their conjugates with proteins and lipids and to study the carbohydrate-specific bindings. A few selected examples of the SPR approaches developed during 2004–2011 for the biosensing of glycoforms and for glycan–protein affinity studies are comprehensively discussed.  相似文献   

15.
Protein adsorption is fundamental to thrombosis and to the design of biocompatible materials. We report a two-dimensional electrophoresis and mass spectrometry study to characterize multiple human plasma proteins adsorbed onto four different types of model surfaces: silicon oxide, dextranized silicon, polyurethane and dextranized polyurethane. Dextran was grafted onto the surfaces of silicon and polyurethane to mimic the blood-contacting endothelial cell glycocalyx surface. Surface topography and hydrophobicity/hydrophilicity were determined and analyzed using atomic force microscopy and water contact angle measurements, respectively. Using two-dimensional electrophoresis, we show that, relative to the unmodified surfaces, dextranization significantly inhibits the adsorption of several human plasma proteins including IGHG1 protein, fibrinogen, haptoglobin, Apo A-IV, Apo A-I, immunoglobulin, serum retinal-binding protein and truncated serum albumin. We further demonstrate the selectivity of plasma protein adsorbed onto the different functionalized surfaces and the potential to control and manipulate proteins adsorption on the surfaces of medical devices, implants and microfluidic devices. This result shows that adsorption experiments using a single protein or a binary mixture of proteins are consistent with competitive protein adsorption studies. In summary, these studies indicate that coating blood-contacting biomedical applications with dextran is an effective route to reduce thrombo-inflammatory responses and to surface-direct biological activities.  相似文献   

16.
We have investigated the adsorption of albumin and fibrinogen onto PET (polyethylene terephthalate) and glass surfaces and how pre-adsorption of albumin onto these surfaces can affect the adsorption of later added fibrinogen. For materials and devices being exposed to blood, adsorption of fibrinogen is often a non-wanted event, since fibrinogen is part of the clotting cascade and unspecific adsorption of fibrinogen can have an influence on the activation of platelets. Albumin is often used as blocking agent for avoiding unspecific protein adsorption onto surfaces in devices designed to handle biological samples, including protein solutions. It is based on the assumption that proteins adsorbs as a monolayer on surfaces and that proteins do not adsorb on top of each other. By labelling albumin and fibrinogen with two different radioactive iodine isotopes that emit gamma radiation with different energies, the adsorption of both albumin and fibrinogen has been monitored simultaneously on the same sample. Information about topography and coverage of adsorbed protein layers has been obtained using AFM (Atomic Force Microscopy) analysis in liquid. Our studies show that albumin adsorbs in a multilayer fashion on PET and that fibrinogen adsorbs on top of albumin when albumin is pre-adsorbed on the surfaces.  相似文献   

17.
The adsorption of proteins at material surfaces is important in applications such as biomaterials, drug delivery, and diagnostics. The interaction of cells with artificial surfaces is mediated through adsorbed proteins, where the type of protein, amount, orientation, and conformation are of consequence for the cell response. Laminin, an important cell adhesive protein that is central in developmental biology, is studied by a combination of quartz crystal microbalance with dissipation (QCM-D) and surface plasmon resonance (SPR) to characterize the adsorption of laminin on surfaces of different surface chemistries. The combination of these two techniques allows for the determination of the thickness and effective density of the protein layer as well as the adsorbed mass and viscoelastic properties. We also evaluate the capacity of QCM-D to be used as a quantitative technique on a nanostructured surface, where protein is adsorbed specifically in a nanopattern exploiting PLL-g-PEG as a protein-resistant background. We show that laminin forms a highly hydrated protein layer with different characteristics depending on the underlying substrate. Using a combination of QCM-D and atomic force microscopy (AFM) data from nanostructured surfaces, we model laminin and antibody binding to nanometer-scale patches. A higher amount of laminin was found to adsorb in a thicker layer of a lower effective density in nanopatches compared to equivalent homogeneous surfaces. These results suggest that modeling of QCM-D data of soft viscoelastic layers arranged in nanopatterns may be applied where an independent measure of the "dry" mass is known.  相似文献   

18.
Surface plasmon resonance (SPR) spectroscopy is used as a scaled-down, analytical, pseudo-chromatography tool for analyzing protein binding and elution over an ion-exchange surface under cyclic sorption conditions. A micrometric-scale adsorption surface was produced by immobilizing a typical ion exchange ligand – diethylaminoethyl (DEAE) – onto commercially available planar gold sensor chip surfaces pre-derivatized with a self-assembled monolayer of 11-mercaptoundecanoic acid with known density. An explicit mathematical formulation is provided for the deconvolution and interpretation of the SPR sensorgrams. An adsorption rate model is proposed to describe the SPR sensorgrams for bovine serum albumin, used here as model protein, when the DEAE surface is subjected to a cyclic series of binding and elution steps. Overall, we demonstrate that the adsorption rate model is capable of quantitatively describing BSA binding and elution for protein titers from dilute conditions up to overloaded conditions and a broad range of salt concentrations.  相似文献   

19.
Hong JW  Chung KH  Yoon HC 《The Analyst》2008,133(4):499-504
An application of a novel polymer microfluidic chip for sample exchange via natural capillary forces for immuno-analysis is described. The microfluidic device was designed to achieve sample replacement by capillary force only, which would therefore be suitable for point-of-care-testing. Complete and automatic replacement of the sample in the reaction chamber with another one makes the chip able to mimic affinity chromatography and immunoassay processes. The microfluidic chip was made using polymer replication techniques, which were suitable for fast and cheap fabrication. Micrometre-sized polystyrene beads were used for the functionalization of biomolecules. Dinitrophenyl (DNP) and anti-DNP antibody coordination was employed on the chip for fluorescence analysis. DNP was immobilized on the polymer beads via a pre-adsorbed dendrimer layer and the beads were placed in the reaction chamber. Fluorescein tagged anti-DNP was successfully observed by a fluorescence microscope after the completion of the entire flow sequence. A calibration curve was registered based on the anti-DNP concentration. A multiplex sensing was accomplished by adding biotin/streptavidin coordination to the system. DNP and biotin conjugated beads were placed in the reaction chamber in an ordered fashion and biospecific bindings of anti-DNP antibody and streptavidin were observed at their expected sites. A ratiometric analysis was carried out with different concentration ratios of anti-DNP/streptavidin. The microfluidic chip described in this work could be applied to various biological and chemical analyses using integrated washing steps or fluid replacement steps with minimum sample handling.  相似文献   

20.
Gaspar A  Gomez FA 《Electrophoresis》2012,33(12):1723-1728
A miniaturized capillary electrophoresis system coupled to a surface plasmon resonance (SPR) sensor on a microfluidic platform fabricated from PDMS is detailed. A previously described split-flow injection technique is first utilized to manipulate sample into the microfluidic chip, followed by separation within the fused-silica capillary and final off-capillary detection of analytes via SPR. Instead of using commercial SPR flow cells requiring relatively large detection volumes, samples of less than 1 nL volume are utilized. The interface between the CE system and SPR sensor made it possible to detect minute volumes of sample with minimal dispersion. The flow cell has the potential to be applicable to miniaturized flow-injection (FI) systems where submicroliter volumes of sample are frequently only available for analysis. The components present in solution, but not bound to the sensor surface, were also investigated. The sensitivity of the CE-SPR system was similar to that found in UV-spectrometric instruments and nonchromophoric components could also be measured.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号