首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
周廉淇  张姣  田芳  张养军  钱小红 《色谱》2013,31(4):355-361
针对传统溶液酶解存在的酶解时间较长、酶自切物干扰以及蛋白酶不能重复使用等缺陷,通过电子转移生成催化剂的原子转移自由基聚合法修饰银丝,并以其为载体制备了一种新型的固定化酶反应器。用质谱考察了银丝固定化酶反应器(SW-Trypsin)的酶解效率、重复性和回收率。结果表明:绒毛状聚合物修饰的SW-Trypsin的酶解效率较高,酶解标准蛋白牛血清白蛋白(BSA)20 min后,肽段的氨基酸序列覆盖率可达93%,高于传统溶液酶解方法酶解16 h所得79%的覆盖率。使用该固定化酶反应器于一个月内8次酶解BSA所得的氨基酸序列覆盖率在89%到97%之间,平均覆盖率为94%,显示出良好的稳定性。另外,该固定化酶反应器酶解马心肌红蛋白(MYO)的回收率为87.67%。最后,用SW-Trypsin酶解腾冲嗜热菌全蛋白20 min,所鉴定到的氨基酸序列覆盖率和蛋白数量与同样条件下溶液酶解16 h的结果接近,且零漏切位点肽段的比例更高。加之容易分离的优点,SW-Trypsin在蛋白质组学的应用中具有良好的前景。  相似文献   

2.
Our previous work has demonstrated that reversed-phase chromatographic micro-beads can be used to capture proteins from complex biological matrices and the surface-bound proteins can be enzymatically digested for protein identification by mass spectrometry (MS). Here we examine the peptides generated from digestion of proteins bound to various types of micro-bead surfaces in order to determine the effects of surface chemistry and surface morphology on the digestion process. Detailed examinations of site cleavages and sequence coverage are carried out for a tryptic digestion of cytochrome c adsorbed on reversed-phase polystyrene divinylbenzene (Poros R2 beads) versus C(18) bonded-phase silica beads. It is shown that although the surface does not completely hinder the digestion of cleavage sites of the protein, the digestion products are clearly different than those obtained from a solution digest. Specifically, a partial digestion results from surface digestion, resulting in a greater number of missed cleavages than a comparable solution digest. Subsequent comparisons of peptide mass maps generated from the digestion of various proteins on surfaces with altering chemistry (C(4), C(8), C(18), and R2 beads), or with different surface morphology, were performed. The results reveal that surface chemistry plays only a minor role in affecting the peptide mass maps, and surface morphology had no noticeable effects on the resulting peptide mass maps. It is also shown that the mass spectrometric detection method used to analyze the digested peptides can significantly influence the information content on cleavage sites and the extent of sequence coverage. The use of a combination of MALDI, LC/off-line MALDI, and LC/ESI MS is demonstrated to be crucial in revealing subtle changes in the peptide mass maps.  相似文献   

3.
An automated proteolytic digestion bioreactor and droplet deposition system was constructed with a plastic microfluidic device for off-line interfacing to matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The microfluidic chips were fabricated in poly(methyl methacrylate) (PMMA), using a micromilling machine and incorporated a bioreactor, which was 100 microm wide, 100 microm deep, and possessed a 4 cm effective channel length (400 nL volume). The chip was operated by pressure-driven flow and mounted on a robotic fraction collector system. The PMMA bioreactor contained surface immobilized trypsin, which was covalently attached to the UV-modified PMMA surface using coupling reagents N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and hydroxysulfosuccinimide (sulfo-NHS). The digested peptides were mixed with a MALDI matrix on-chip and deposited as discrete spots on MALDI targets. The bioreactor provided efficient digestion of a test protein, cytochrome c, at a flow rate of 1 microL/min, producing a reaction time of approximately 24 s to give adequate sequence coverage for protein identification. Other proteins were also evaluated using this solid-phase bioreactor. The efficiency of digestion was evaluated by monitoring the sequence coverage, which was 64%, 35%, 58%, and 47% for cytochrome c, bovine serum albumin (BSA), myoglobin, and phosphorylase b, respectively.  相似文献   

4.
Microchip-based proteomic analysis requires proteolytic digestion of proteins in microdevices. Enzyme reactors in microdevices, fabricated in glass, silicon, and PDMS substrates, have recently been demonstrated for model protein digestions. The common approach used for these enzyme reactors is employment of a syringe pump(s) to generate hydrodynamic flow, driving the proteins through the reactors. Here we present a novel approach, using electroosmotic flow (EOF) to electrokinetically pump proteins through a proteolytic system. The existence of EOF in the proteolytic system packed with immobilized trypsin gel beads was proven by imaging the movement of a neutral fluorescent marker. Digestions of proteins were subsequently carried out for 12 min, and the tryptic peptides were analyzed independently using capillary electrophoresis (CE) and MALDI-TOF mass spectrometry (MS). The results from CE analysis of the tryptic peptides from the EOF-driven proteolytic system and a conventional water bath digestion were comparable. MALDI-TOF MS was used to identify the parent protein and the tryptic peptides using MS-Fit database searching. The potential utility of the EOF-driven proteolytic system was demonstrated by direct electro-elution of proteins from an acrylamide gel into the proteolytic system, with elution and tryptic digestion achieved in a single step. The EOF-driven proteolytic system, thus, provides a simple way to integrate protein digestion into an electrophoretic micro total analysis system for protein analysis and characterization.  相似文献   

5.
The preparation and characterization of a new trypsin-based bioreactor is here described for on-line protein digestion and peptide analysis. Trypsin was immobilized on an epoxy-modified silica monolithic support with a single reaction step and the amount of immobilized enzyme was found to be 66.07 mg (+/-11.75 S.D.)/column (n = 6). The bioreactor was coupled through a switching valve to an analytical column for the on-line digestion, peptide separation and identification of test proteins by ESI-MS-MS. The influence of various parameters (flow rate, temperature, buffer pH and molarity, etc.) on enzymatic activity was investigated by an experimental design and the mostly significant factor was found to be the flow rate. The efficacy of the reported on-line bioreactor for tryptic mapping is reported for somatostatin and myoglobin, selected as model compounds. Tryptic peptide maps obtained by on-line digestion of myoglobin were compared to those obtained by traditional off-line digestion. Sequence coverage obtained with the on-line protocol (21 peptides, 75.16% coverage of myoglobin sequence) was found to be comparable to the one obtained with the off-line protocol (18 peptides, 76.47% coverage). Sensitivity for myoglobin digestion and identification was 0.1 mg/ml. The reproducibily of the peptide maps in terms of retention time was from 1.53 to 4.31%, R.S.D.  相似文献   

6.
A nano-scale solid-phase extraction (SPE) device was developed for the detection of gel-separated proteins in low abundance by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) with a simplified microfabrication technology. By using SU-8 photoresist instead of epoxy glue to connect the microchannel and transfer capillary, polymeric contaminant signals in MS analysis were significantly reduced. Micro SPE columns with different capacities and geometric characteristics were investigated in order to increase the detection sensitivity and decrease spot size for MALDI-TOF-MS analysis. It is shown that enhancements in sensitivities for the detection of proteins in low abundance were correlated with the reduction in column capacity and increase in column aspect ratio. Fifty nanoliters of matrix solution were sufficient to elute the sample completely from the optimized micro SPE column with 3.5 nL capacity. The mass spectrum of a 5 fmol in-gel tryptic digest of bovine serum albumin (BSA), processed by the micro SPE column, demonstrated that 29 peptides matched the protein giving a sequence coverage of 51%, which was better than that obtained from analysis of 25 fmol of the same sample prepared by the dried-droplet method. With the micro SPE column treatment of 2 microL of digestion supernatant of a gel spot of the IQGAP1 protein, 15 peptides were detected from the mass spectrum with the highest individual score of 111, while, with a ZipTip procedure, only nine peaks were detected with the highest individual score of 71. Analytical results demonstrated that this approach greatly improved the sequence coverage and identification specificity for the tested protein. It can serve as a very useful tool in proteomics studies, especially for low abundance proteins.  相似文献   

7.
In this study, methodology was developed for on-line and miniaturized enzymatic digestion with liquid chromatographic (LC) separation and mass spectrometric (MS) detection. A packed capillary LC-MS system was combined with on-line trypsin cleavage of a model protein, lactate dehydrogenase, to provide an efficient system for peptide mapping. The protein was injected onto an enzymatic capillary reactor and the resulting peptides were efficiently trapped on a capillary trapping column. Different trapping columns were evaluated to achieve a high binding capacity for the peptides generated in the enzyme reactor. The peptides were further eluted from the pre-column and separated on an analytical capillary column by a buffer more suitable for the following an electrospray ionisation (ESI) MS process. An important aspect of the on-line approach was the desalting of peptides performed in the trapping column to avoid detrimental signal suppression in the ESI process. The developed on-line system was finally compared to a classical digestion in solution, with reference to peptide sequence coverage and sensitivity. It was shown that the on-line system gave more than 100% higher peptide sequence coverage than traditional digestion methods.  相似文献   

8.
Desorption electrospray ionization mass spectrometry (DESI-MS) was demonstrated as a method to detect and identify peptides from two-dimensional separations of cytochrome c and myoglobin tryptic digests on ProteoChrom HPTLC Cellulose sheets. Data-dependent tandem mass spectra were acquired during lane scans across the TLC plates. Peptides and the corresponding proteins were identified using a protein database search software. Two-dimensional distributions of identified peptides were mapped for each separated protein digest. Sequence coverages for cytochrome c and myoglobin were 81 and 74%, respectively. These compared well with those determined using the more standard HPLC/ESI-MS/MS approach (89 and 84%, respectively). Preliminary results show that use of more sensitive instrumentation has the potential for improved detection of peptides with low R(f) values and improvement in sequence coverage. However, less multiple charging and more sodiation were seen in HPTLC/DESI-MS spectra relative to HPLC/ESI-MS spectra, which can affect peptide identification by MS/MS. Methods to increase multiple charging and reduce the extent of sodiation are currently under investigation.  相似文献   

9.
Highly efficient and rapid proteolytic digestion of proteins into peptides is a crucial step in shotgun-based proteome-analysis strategy.Tandem digestion by two or more proteases is demonstrated to be helpful for increasing digestion efficiency and decreasing missed cleavages,which results in more peptides that are compatible with mass-spectrometry analysis.Compared to conventional solution digestion,immobilized protease digestion has the obvious advantages of short digestion time,no self-proteolysis,and reusability.We proposed a multiple-immobilized proteases-digestion strategy that combines the advantages of the two digestion strategies mentioned above.Graphene-oxide(GO)-based immobilized trypsin and endoproteinase Glu-C were prepared by covalently attaching them onto the GO surface.The prepared GO-trypsin and GO-Glu-C were successfully applied in standard protein digestion and multiple immobilized proteases digestion of total proteins of Thermoanaerobacter tengcongensis.Compared to 12-hour solution digestion using trypsin or Glu-C,14%and 7%improvement were obtained,respectively,in the sequence coverage of BSA by one-minute digestion using GO-trypsin and GO-Glu-C.Multiple immobilized-proteases digestion of the total proteins of Thermoanaerobacter tengcongensis showed 24.3%and 48.7%enhancement in the numbers of identified proteins than was obtained using GO-trypsin or GO-Glu-C alone.The ultra-fast and highly efficient digestion can be contributed to the high loading capacity of protease on GO,which leads to fewer missed cleavages and more complete digestion.As a result,improved protein identification and sequence coverage can be expected.  相似文献   

10.
Simple and efficient digestion of proteins, particularly hydrophobic membrane proteins, is of significance for comprehensive proteome analysis using the bottom-up approach. We report a microwave-assisted acid hydrolysis (MAAH) method for rapid protein degradation for peptide mass mapping and tandem mass spectrometric analysis of peptides for protein identification. It uses 25% trifluoroacetic acid (TFA) aqueous solution to dissolve or suspend proteins, followed by microwave irradiation for 10 min. This detergent-free method generates peptide mixtures that can be directly analyzed by liquid chromatography (LC) matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) without the need of extensive sample cleanup. LC-MALDI MS/MS analysis of the hydrolysate from 5 microg of a model transmembrane protein, bacteriorhodopsin, resulted in almost complete sequence coverage by the peptides detected, including the identification of two posttranslational modification sites. Cleavage of peptide bonds inside all seven transmembrane domains took place, generating peptides of sizes amenable to MS/MS to determine possible sequence errors or modifications within these domains. Cleavage specificity, such as glycine residue cleavage, was observed. Terminal peptides were found to be present in relatively high abundance in the hydrolysate, particularly when low concentrations of proteins were used for MAAH. It was shown that these peptides could still be detected from MAAH of bacteriorhodopsin at a protein concentration of 1 ng/microl or 37 fmol/microl. To evaluate the general applicability of this method, it was applied to identify proteins from a membrane protein enriched fraction of cell lysates of human breast cancer cell line MCF7. With one-dimensional LC-MALDI MS/MS, a total of 119 proteins, including 41 membrane-associated or membrane proteins containing one to 12 transmembrane domains, were identified by MS/MS database searching based on matches of at least two peptides to a protein.  相似文献   

11.
For bottom-up MS, the digestion step is critical and is typically performed with trypsin. Solvent-assisted digestion in 80% acetonitrile has previously been shown to improve protein sequence coverage at shorter digestion times. This has been attributed to enhanced enzyme digestion efficiency in this solvent. However, our results demonstrate that tryptic digestion in 80% acetonitrile is less efficient than that of conventional (aqueous) digestion. This is a consequence of decreased enzyme activity beyond ∼40% acetonitrile, increased enzyme autolysis and lower protein solubility in 80% acetonitrile. We observe multiple missed cleavages and reduced concentration of fully cleaved digestion products. Nonetheless we confirm, through room temperature solvent-assisted digestion, a consistent improvement in protein sequence coverage when analyzed by mass spectrometry. These results are explained through the increased number of unique digestion products available for detection. Thus, while solvent-assisted digestion has clear merits for proteome analysis, one should be aware of the inefficiency of protein digestion though this protocol, particularly with absolute protein quantitation experiments.  相似文献   

12.
A simple, rapid, straightforward and washing/separation free of in-solution digestion method for microwave-assisted tryptic digestion of proteins (cytochrome c, lysozyme and myoglobin) using bare TiO(2) nanoparticles (NPs) prepared in aqueous solution to serve as multifunctional nanoprobes in electrospray ionization mass spectrometry (ESI-MS) was demonstrated. The current approach is termed as 'on particle ionization/enrichment (OPIE)' and it can be applied in ESI-MS, atmospheric pressure-matrix-assisted laser desorption/ionization mass spectrometry (AP-MALDI-MS) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The bare TiO(2) NPs can assist, accelerate and effectively enhance the digestion efficiency, sequence coverage and detection sensitivity of peptides for the microwave-assisted tryptic digestion of proteins in ESI-MS. The reason is attributed to the fact that proteins or partially digested proteins are easily attracted or concentrated onto the surface of TiO(2) NPs, resulting in higher efficiency of digestion reactions in the microwave experiments. Besides, the TiO(2) NPs could act as a microwave absorber to accelerate and enrich the protein fragments in a short period of time (40-60 s) from the microwave experiments in ESI-MS. Furthermore, the bare TiO(2) NPs prepared in aqueous solution exhibit high adsorption capability toward the protein fragments (peptides); thus, the OPIE approach for detecting the digested protein fragments via ESI and MALDI ionization could be achieved. The current technique is also a washing and separation-free technique for accelerating and enriching microwave-assisted tryptic digestion of proteins in the ESI-MS and MALDI-MS. It exhibits potential to be widely applied to biotechnology and proteome research in the near future.  相似文献   

13.
Proteins with molecular mass (M(r)) <20 kDa are often poorly separated in 2-D sodium dodecyl sulfate polyacrylamide gel electrophoresis. In addition, low-M(r) proteins may not be readily identified using peptide mass fingerprinting (PMF) owing to the small number of peptides generated in tryptic digestion. In this work, we used a 2-D liquid separation method based on chromatofocusing and non-porous silica reversed-phase high-performance liquid chromatography to purify proteins for matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis and protein identification. Several proteins were identified using the PMF method where the result was supported using an accurate M(r) value obtained from electrospray ionization TOFMS. However, many proteins were not identified owing to an insufficient number of peptides observed in the MALDI-TOF experiments. The small number of peptides detected in MALDI-TOFMS can result from internal fragmentation, the few arginines in its sequence and incomplete tryptic digestion. MALDI-QTOFMS/MS can be used to identify many of these proteins. The accurate experimental M(r) and pI confirm identification and aid in identifying post-translational modifications such as truncations and acetylations. In some cases, high-quality MS/MS data obtained from the MALDI-QTOF spectrometer overcome preferential cleavages and result in protein identification.  相似文献   

14.
Protein identification is routinely accomplished by peptide sequencing using mass spectrometry (MS) after enzymatic digestion. Site-specific chemical modification may improve peptide ionization efficiency or sequence coverage in mass spectrometry. We report herein that amino group of lysine residue in peptides can be selectively modified by reaction with a peroxycarbonate and the resulting lysine peroxycarbamates undergo homolytic fragmentation under conditions of low-energy collision-induced dissociation (CID) in electrospray ionization (ESI) and matrix-assisted laser desorption and ionization (MALDI) MS. Selective modification of lysine residue in peptides by our strategy can induce specific peptide cleavage at or near the lysine site. Studies using deuterated analogues of modified lysine indicate that fragmentation of the modified peptides involves apparent free-radical processes that lead to peptide chain fragmentation and side-chain loss. The formation of a-, c-, or z-types of ions in MS is reminiscent of the proposed free-radical mechanisms in low-energy electron capture dissociation (ECD) processes that may have better sequence coverage than that of the conventional CID method. This site-specific cleavage of peptides by free radical- promoted processes is feasible and such strategies may aid the protein sequencing analysis and have potential applications in top-down proteomics.  相似文献   

15.
A comparative analysis of protein identification for a total of 162 protein spots separated by two-dimensional gel electrophoresis from two fully sequenced archaea, Methanococcus jannaschii and Pyrococcus furiosus, using MALDI-TOF peptide mass mapping (PMM) and mu LC-MS/MS is presented. 100% of the gel spots analyzed were successfully matched to the predicted proteins in the two corresponding open reading frame databases by mu LC-MS/MS while 97% of them were identified by MALDI-TOF PMM. The high success rate from the PMM resulted from sample desalting/concentrating with ZipTip(C18) and optimization of several PMM search parameters including a 25 ppm average mass tolerance and the application of two different protein molecular weight search windows. By using this strategy, low-molecular weight (<23 kDa) proteins could be identified unambiguously with less than 5 peptide matches. Nine percent of spots were identified as containing multiple proteins. By using mu LC-MS/MS, 50% of the spots analyzed were identified as containing multiple proteins. mu LC-MS/MS demonstrated better protein sequence coverage than MALDI-TOF PMM over the entire mass range of proteins identified. MALDI-TOF and PMM produced unique peptide molecular weight matches that were not identified by mu LC-MS/MS. By incorporating amino acid sequence modifications into database searches, combined sequence coverage obtained from these two complimentary ionization methods exceeded 50% for approximately 70% of the 162 spots analyzed. This improved sequence coverage in combination with enzymatic digestions of different specificity is proposed as a method for analysis of post-translational modification from 2D-gel separated proteins.  相似文献   

16.
The effect of vortex‐induced vibration during tryptic digestion was investigated by applying different vibrational speeds (0, 600, 1200, or 2500 rpm) to digestion solutions for varying durations (10, 20, 30, 40, or 60 min) at two different incubation temperatures (25°C or 37°C). The most rapid digestion was observed with the highest vibrational speed and temperature. With the application of 2500 rpm at 37°C, the tryptic digestion of each of three standard proteins (cytochrome c, myoglobin, or bovine serum albumin) provided complete disappearance of the protein within 60 min, as determined by matrix‐assisted laser desorption/ionization mass spectrometry. Compared to conventional overnight digestion, 60‐min vortex‐assisted tryptic digestion generated longer peptides, due primarily to the limited digestion time and provided better sequence coverages (89% vs. 78% for cytochrome c, 100% vs. 87% for myoglobin, and 38% vs. 26% for BSA). The longer peptides should be advantageous to analytical methods such as the middle‐down approach that benefit from increased sequence coverage of proteins. Vortex‐assisted tryptic digestion is expected to be a useful method for rapid tryptic digestion of proteins. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
A cycloalkyl aliphatic saccharide, 5-cyclohexyl-1-pentyl-beta-D-maltoside (CYMAL-5), was evaluated as a novel additive in a high-throughput in-gel protein digestion system using 96-well plates. Addition of 0.1% CYMAL-5 (final concentration) during trypsin treatment was compatible with both matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis, and gave a better digestion efficiency than n-octylglucoside, which we previously reported. In-gel reduction and alkylation of Cys residues under denaturing conditions also improved the sequence coverage of peptides. In-gel tryptic digestion with the optimum combination of 0.5 mm thick gels, negative staining, alkylation under denaturing conditions (6 M guanidine hydrochloride), and digestion in the presence of CYMAL-5, gave excellent performance especially for membrane protein analysis, where recovery of hydrophobic peptides was markedly enhanced. The new protocol is simple and convenient, and should be widely applicable to gel-based proteomics.  相似文献   

18.
Sequence-specific proteolysis is an important part of protein identification by MS. Digestion of protein is commonly performed in-solution, in sample vials with volumes ranging from milli- to microliters. When digestion is performed with a sample volume below 1 microL, handling of solution and potential sample loss via adsorption become significant issues. In this report, a proof of concept for the digestion of a small volume protein solution inside a capillary was demonstrated using a discontinuous buffer system previously studied (Nesbitt, C. A., et al. J. Chromatogr. A 2005, 1073, 175-180). Upon voltage application, a pH junction was created by the discontinuous buffer. Using myoglobin as an example, the protein molecules were enriched at the junction with an estimated volume of a few nanoliters. A protease, trypsin, was then introduced to myoglobin at the junction by coenrichment to induce in-capillary digestion. The voltage application was then suspended to provide the necessary time (2 h) for the proteolysis to proceed. When completed, voltage application was resumed, and the discontinuous buffer reconcentrated the peptides formed from digestion. Importantly, the refocused peptides appeared to roughly elute according to their pIs, resulting in a partial separation. Direct sample deposition from capillary was performed to facilitate mass spectral analysis by MALDI. The partial separation, according to pI, offered the potential benefits of MALDI MS signal enhancement and provided supplementary pI information for peptide identity assignment.  相似文献   

19.
Condensed phase protein sequencing typically relies on N-terminal labeling with phenylisothiocyanate ("Edman" reagent), followed by cleavage of the N-terminal amino acid. Similar Edman degradation has been observed in the gas phase by collision-activated dissociation of the N-terminal phenyl thiocarbamoyl protonated peptide [1] to yield complementary b1 and y(n-1) fragments, identifying the N-terminal amino acid. By use of infrared multiphoton (rather than collisional) activation, and Fourier transform ion cyclotron resonance (rather than quadrupole) mass analysis, we extend the method to direct analysis of a mixture of tryptic peptides. We validate the approach with bradykinin as a test peptide, and go on to analyze a mixture of 25 peptides produced by tryptic digestion of apomyoglobin. A b1+ ion is observed for three of the Edman-derivatized peptides, thereby identifying their N-terminal amino-acids. Search of the SWISS-PROT database gave a single hit (myoglobin, from the correct biological species), based on accurate-mass FT-ICR MS for as few as one Edman-derivatized tryptic peptide. The method is robust-it succeeds even with partial tryptic digestion, partial Edman derivatization, and partial MS/MS IRMPD cleavage. Improved efficiency and automation should be straightforward.  相似文献   

20.
Based on a previous study of protein digestion inside the nanoreactor channels of the mesoporous molecular sieve silicate SBA-15 (Chem. Eur. J. 2005, 11: 5391), we have developed a highly efficient enrichment and subsequent tryptic digestion of proteins in SBA-15 for matrix-assisted laser desorption/ionization mass spectrometry with time-of-flight/time-of-flight analyzer (MALDI-TOF/TOF) peptide mapping. The performance of the method is exemplified with myoglobin and cytochrome c. First, protein adsorption isotherms for two standard proteins with a range of initial concentration of proteins were investigated at room temperature. The results revealed that the kinetic adsorption rate of a protein within SBA-15 was independent of initial protein concentration, and a 15-min protein enrichment within SBA-15 could be enough for protein identification in biological samples. It was noticed that no washing steps were needed to avoid protein loss due to desorption from the mesochannels into solution. Second, protein digestion inside the channels of SBA-15 was also optimized. After adsorption of proteins into SBA-15 in 15 min, the trypsin solution (pH 8) was directly added to the SBA-15 beads with immobilized proteins by centrifugation, and then the digestion was performed for 15 min at 37 degrees C. It was observed that a higher peptide sequence covering of 98% for myoglobin was obtained by MALDI-TOF/TOF analysis, compared to in-solution digestion. So the protein digestion inside SBA-15 was proved to be significantly faster and yielded a better sequence coverage. The new procedure allows for rapid protein enrichment and digestion inside SBA-15, and has great potential for protein analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号