首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The development of a rapid, precise and accurate speciation method for the simultaneous determination of mono-, di- and tributyltin in environmental samples is described. The method is based on using isotope dilution gas chromatography/mass spectrometry (GC/MS) with electron ionization, a widely used technique in routine testing laboratories. A mixed spike containing (119)Sn-enriched monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT) was used for the isotope dilution of the samples. Five molecular ions were monitored for each analyte, corresponding to the (116)Sn, (117)Sn, (118)Sn, (119)Sn and (120)Sn isotopes. The detection at masses corresponding to (116)Sn and (117)Sn were used to correct for m + 1 and m + 2 contributions of (13)C from the organic groups attached to the tin atom on the (118)Sn, (119)Sn and (120)Sn masses with simple mathematical equations and the concentrations of the butyltin compounds were calculated based on the corrected (118)Sn/(119)Sn and (120)Sn/(119)Sn isotope ratios. The (119)Sn-enriched multispecies spike was applied with satisfactory results to the simultaneous determination of MBT, DBT and TBT in three certified reference materials: two sediments, PACS-2 and BCR 646, and the mussel tissue CRM 477. The method was compared with a previously published GC/inductively coupled plasma MS isotope dilution procedure, developed in our laboratory, by injecting the same samples into both instruments. Comparable analytical results in terms of precision and accuracy are demonstrated for both atomic and molecular mass spectrometric detectors. Thus, reliable quantitative organotin speciation analysis can be achieved using the more widespread and inexpensive GC/MS instrument.  相似文献   

2.
The highly qualified primary method of species-specific isotope dilution analysis has been employed in this work to evaluate for the first time the levels of butyltin compounds in the estuary of the river Eo (Northwest Spain) where there is, since many years, a high oyster farming activity. A spike solution containing mono-, di- and tributyltin enriched in 119Sn allowed the simultaneous determination of the three compounds in different marine environmental and biological samples collected in this area (seawater samples, sediments and biological tissues of four different marine species). The results obtained in this work showed toxic TBT levels for many marine species in 45% of the seawater samples analyzed whereas significant organotin concentrations were found to be obtained only in one of the sediments analyzed. On the other hand, TBT levels ranging from 20 to almost 200 ng g− 1 (dry weight) were obtained in the different biological tissues analyzed demonstrating the bioaccumulation of organotin compounds in certain marine species.  相似文献   

3.
A standard GC-MS instrument with electron impact ionisation has been used to develop a fast, simple and reliable method for the simultaneous determination of monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT) in water samples. Isotope dilution analysis (IDA) is used for the determination of species, taking advantage of a commercially available spike solution containing a mixture of MBT, DBT and TBT enriched in 119Sn. Method detection limits for 100-mL samples were between 0.18 and 0.25 ng L−1 for the three butyltin compounds with typical RSD between 2 and 4% at levels between 100 and 10 ng L−1, respectively. Recovery of tin species in spiked samples (natural water, wastewater and seawater) was quantitative. The stability of butyltin compounds in collected seawater samples was also studied. The addition of a 1% (v/v) glacial acetic acid preserved tin species in the samples for at least 5 days at room temperature. The IDA method was finally implemented in a routine testing laboratory and it was subsequently accredited by the Spanish National Accreditation Body according to the requirements of UNE-EN ISO/IEC 17025.  相似文献   

4.
Isotope-dilution analysis in combination with GC-ICP-MS detection has been applied to the determination of butyltin species in environmental samples. Different spikes containing the isotopically labeled butyltin species have been synthesized in the laboratory after optimization of the reaction conditions. The isotopic compositions of the tin species in the different spike solutions were determined by GC-ICP-MS after derivatization by aqueous ethylation with sodium tetraethylborate. Reverse isotope-dilution analysis was used for quantitation of the spike solutions by means of natural MBT, DBT, and TBT standards. The mixed spikes were used for simultaneous analysis of MBT, DBT and TBT in the certified reference materials, PACS-2, CRM 462, and CRM 646, with satisfactory results. The excellent agreement of the different speciation results obtained by use of the different spikes is a good indicator of the precision, accuracy, and reliability which can be achieved by using isotope-dilution analysis for trace metal speciation.Application of a double spike containing (119)Sn-enriched MBT (79.7 At%), (118)Sn-enriched DBT (86.7 At%), and (119)Sn-enriched TBT (83.1 At%) also enabled evaluation of the conditions resulting in quantitative extraction of the species from the solid matrix, in combination with possible alterations depending on the different extraction procedures used (mechanical shaking, ultrasounds, and microwaves). Mathematical equations used for this purpose computed the correct species concentrations directly and, additionally, the decomposition factors (from TBT to DBT and from DBT to MBT) after precise measurement of the (119)Sn/(120)Sn and (118)Sn/(120)Sn ratios for all butyltin species by GC-ICP-MS.  相似文献   

5.
The fragmentation patterns of butyltin compounds (mono-, di-, and tributyltin) in an electron impact ion source were studied using an isotope pattern reconstruction algorithm with emphasis on isotope ratio measurements from molecular clusters. For this purpose, standards of natural tin isotope abundance and a (119)Sn-enriched mixture of the three compounds were both ethylated and propylated using sodium tetraalkylborates. The corresponding mass spectra of the various tetraalkyltin compounds prepared were obtained by GC/MS after their extraction with hexane.The results showed that pure interference-free molecular clusters were obtained only for certain R(3)Sn(+) ions where no isobaric overlap with R(2)SnH(+) ions occurred (e.g. BuEt(2)Sn(+) overlaps with Bu(2)SnH(+)). These ions are ideal candidates for accurate Sn isotope ratio measurements, while isotope pattern perturbing interferences are observed for other molecular fragments down to Sn(.)(+). Isotope pattern reconstruction algorithm thus can be used as an analytical tool to ensure the absence of molecular interferences--a requirement for accurate isotope ratio measurements from molecular clusters. The relevance of these studies for the determination of butyltin compounds in environmental samples by isotope dilution GC/MS is also discussed.  相似文献   

6.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography – mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30–1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

7.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

8.
A species-specific isotope dilution (ID) method is described for the determination of mono-, di, and tri-butyltin compounds in sediment by gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS), where the mixture of 118Sn-enriched butyltin compounds synthesized in our laboratory was used as a spike. A correction method for the mass bias, a quantitative extraction of the butyltins from sediment, and an assay for the concentration of the standard solution for the reverse ID procedure were investigated to achieve a reliable ID analysis. The spike solution was added with tri-propyltin (TPrT), and the butyltins were extracted by mechanical shaking into acetic acid-tropolone-toluene. The extracted butyltins were ethylated with sodium tetraethylborate and measured by GC-ICP-MS. The mass bias correction factor for the butyltins was calculated with the measured area ratio of 120Sn/118Sn of TPrT in each chromatographic run, and the correction was carried out. The mass bias was well corrected with this in-run correction (the standard uncertainties of the corrected 120Sn/118Sn for the butyltins were in the range 0.03-0.45%, typically 0.25%, with triplicate measurement corresponding to 0.02-0.37% mass bias). The extraction efficiency of mono-butyltin (MBT) from sediment was improved by using tropolone-toluene as the solvent. Well-defined standard solutions for the reverse-ID procedure could be obtained by an assay for the purities of the natural abundance butyltin chloride reagents used for preparing the standard solutions. Overall uncertainties associated with the present method were estimated, where the sediment certified reference materials, PACS-2 and BCR 646, were analyzed. The uncertainty arising from the extraction was the main contributor to the overall uncertainties for MBT and di-butyltin (DBT) determinations, while with the case of tri-butyltin (TBT) determination the uncertainties arising from the purity of TBT chloride reagent used for preparing the standard solution was a large contributor to the overall uncertainties although the uncertainty arising from the extraction was also a main contributor. The analytical results of MBT, DBT, and TBT in both reference materials, except for MBT results in PACS-2, were in good agreement with the certified values in each. The result of MBT in PACS-2 (0.677 +/- 0.049 microg g(-1) as tin, mean +/- expanded uncertainty) was significantly higher than the certified value (0.45 +/- 0.05 microg g(-1)), but closely matched with the lately reported values (Rajendran, Tao, Nakazato and Miyazaki, Analyst, 2000, 125, 1757: 0.62 +/- 0.02 microg g(-1); Chiron, Roy, Cottier and Jeannot, J. Chromatogr. A, 2000, 879, 137: 0.634 +/- 0.082 microg g(-1); Alonso, Encinar, Gonzalez and Sanz-Medal, Anal. Bioanal. Chem., 2002, 373, 432: 0.64 +/- 0.04 microg g(-1). The present method is concluded to be reliable for the determination of MBT, DBT, and TBT in sediment.  相似文献   

9.
The optimization and application of gas chromatograph coupled with inductively coupled plasma mass spectrometer (GC-ICPMS) (equipped with a commercially available interface) for the speciation of butyltin compounds in freshwater origin sediment and mussel samples is described. Optimization focused on the system parameters that have the greatest effect on signal intensity such as plasma power, ion lenses and make up gas flow (in the interface). Xenon (Xe) containing argon gas (Ar) was applied as tuning gas providing continuous Xe signal for the optimization of system parameters. It was found that plasma power and make up gas are interrelated variables and provide a set of paired optimum values at each power settings. The absolute optimum values obtained at 800 W plasma power and 1.2 L min−1 make up gas flow rate when 7 mm sample depth was adjusted. The optimum settings obtained were then checked by means of a test solution (tetraethyltin dissolved in hexane). Same optimum conditions were found when tin (Sn) transient signals were monitored. Detection limits were calculated for the three species using the optimized system parameters. Detection limits are the following: for monobutyltin (MBT) 5.6 ng Sn kg−1, for dibutyltin (DBT) 6.6 ng Sn kg−1 and for tributyltin (TBT) 3.4 ng Sn kg−1 obtained. Determination of the butyltin compounds were carried out by means of species-specific isotope dilution analysis. The spike solution contained all species investigated but with altered isotopic composition. Each species were enriched in their 119Sn isotope. Concentrations found in Hungarian freshwater origin mussel and sediment samples ranged between 19 and 39 ng g−1for MBT, between 1.2 and 6.3 ng g−1 for DBT and between 1.2 and 3.2 ng g−1 for TBT indicated as Sn in dry weight. Validation of the method was done by means of certified reference materials (BCR CRM 646 and 477). Good agreement was found between certified and experimental values. Normalized deviation (En) was also computed in order to validate the method used. En values obtained ranged between 0.07 and 0.11 for mussel samples and between 0.26 and 0.72 for sediment samples. These values show that isotope dilution-GC-ICPMS methodology is valid for the determination of MBT, DBT and TBT from both types of matrices.  相似文献   

10.
A new extraction method for the determination of tributyltin (TBT), dibutyltin (DBT) and monobutyltin (MBT) in sediments based on extraction with tartaric acid and methanol has been developed. Tin species were extracted from sediment samples using focused microwave technology, then ethylated with sodium tetraethylborate (NaBEt4) and analyzed by isotope dilution (ID) gas chromatography-mass spectrometry (GC-MS). The advantages of such methodology in comparison with other established extraction methods for the routine speciation analysis of organotin compounds are discussed with respect to sulfur interferences co-extracted from complex matrices.Interferences from elemental sulfur are normally found with acetic acid extraction, but with tartaric acid extraction these interferences were eliminated, demonstrating selective extraction.The accuracy of the analytical procedure was established by analyzing a certified reference material (CRM) (PACS-2, marine sediment) and comparing the results to the certified values. Good agreement between determined and certified values for butyltin compounds was obtained. Finally, some complex sediment samples collected from San Vicente's Bay, Chile, were analyzed with the proposed methodology, demonstrating its potential value for monitoring butyltins in environmental samples with high concentrations of sulfur compounds.  相似文献   

11.
The capabilities of National Metrology Institutes (NMIs—those which are members of the Comité Consultatif pour la Quantité de Matière (CCQM)of the CIPM) and selected outside "expert" laboratories to quantitate (C4H9)3Sn+ (TBT) in a prepared marine sediment were assessed. This exercise was sanctioned by the 7th CCQM meeting, April 4–6, 2001, as an activity of the Inorganic Analysis Working Group and was jointly piloted by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and the Laboratory of the Government Chemist (LGC), UK. A total of 11 laboratories submitted results (7 NMIs, and 4 external labs). Two external laboratories utilized a standard calibration approach based on a natural abundance TBT standard, whereas all NMIs relied upon isotope dilution mass spectrometry for quantitation. For this purpose, a species specific 117Sn-enriched TBT standard was supplied by the LGC. No sample preparation methodology was prescribed by the piloting laboratories and, by consequence, a variety of approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with Grignard derivatization, ethylation and direct sampling. Detection techniques included ICP–MS (with GC and HPLC sample introduction), GC–MS, GC–AED and GC–FPD. Recovery of TBT from a control standard (NRCC CRM PACS-2 marine sediment) averaged 93.5±2.4% (n=14). Results for the pilot material averaged 0.680±0.015 µmol kg–1 (n=14; 80.7±1.8 µg kg–1) with a median value of 0.676 µmol kg–1. Overall, performance was substantially better than state-of-the-art expectations and the satisfactory agreement amongst participants permitted scheduling of a follow-up Key comparison for TBT (K-28), a Pilot intercomparison for DBT (P-43), and certification of the test sediment for TBT content and its release as a new Certified Reference Material (HIPA-1) with a TBT content of 0.679±0.089 µmol kg–1 (expanded uncertainty, k=2, as Sn) (80.5±10.6 µg kg–1).Electronic Supplementary Material Supplementary material is available in the online version of this article at .  相似文献   

12.
A new method for the speciation of butyltin compounds by solid phase extraction and direct injection using gas chromatography-mass spectrometry (GC/MS) is described. The compounds were complexed with sodium diethyldithiocarbamate and retained on a C60 sorbent column. The neutral chelates of butyltin compounds were eluted with ethyl acetate containing NaBPr4 as derivatising reagent. The main analytical figures of merit of the proposed method for 10 ml of sample are: linear range 0.2-35 ng/g expressed as Sn; limits of detection, 0.07, 0.09 and 0.10 ng/g as Sn for monobutyltin, dibutyltin and tributyltin, respectively. No interferences from metal ions such as Zn2+, Fe3+, Sb3t, Pb2+, Ni2+ and Mn2+ were observed in the determination of organotin compounds. The validation of method was performed out by the analysis of a standard reference sediment (CRM 462). The method was also applied to the determination of butyltin compounds in marine sediment samples.  相似文献   

13.
An in vitro gastrointestinal digestion approach in combination with species-specific isotope dilution analysis has been employed for the first time to study the transformation reactions as well as the solubilisation of butyltin species throughout a simulated human digestion. Different sample preparation procedures were assayed in order to avoid problems derived from lack of isotope equilibration between the endogenous and the isotopically-enriched added species. A triple spike approach, which can be used to calculate the corrected concentrations of mono-, di-, and tributyltin (MBT, DBT and TBT, respectively), as well as six interconversions, was employed throughout this work. In order to calculate and compare the species degradation factors, a triple spike solution containing each butyltin species enriched in a different isotope was added to the simulated gastric and intestinal fluids before the digestion procedures in the presence and in the absence of a solid biological matrix (commercial mussel tissue). Additionally, by analysing the soluble and insoluble fractions resulting from the simulated digestion of a commercial mussel tissue (gastric and gastric plus intestinal digestion), total mass balances for each butyltin compound could be derived. For this purpose, the isotopically-enriched species were added after the enzymatic digestions in order to avoid problems derived from lack of isotope equilibration. The mass balances provided information not only about the solubilisation but also about the degradation of the butyltin species during the digestion procedures. Good agreement between the degradation factors calculated under all experiments performed in this work and between those reported in previous works were obtained. The most serious degradation observed was that of DBT to produce MBT, whereas slight degradations of TBT and MBT were detected. Moreover, a worrying 61% of the original total butyltin content present in a commercial mussel tissue was found to be solubilised after complete simulated gastrointestinal digestion, with minimal degradation of TBT.  相似文献   

14.
Cai Y  Rapsomanikis S  Andreae MO 《Talanta》1994,41(4):589-594
We have determined tributyltin and dibutyltin species in various environmental sediment samples (marine, harbour and river sediment) using the in situ aqueous ethylation-gas chromatography-atomic absorption spectrometry method subsequent to extraction by methanol containing O.5M HCl. The present technique provides a significantly lower detection limit than previous methods, so that tributyltin can for the first time be measured in some of the samples. Thus, the method described is well suited for the determination of tributyltin and dibutyltin compounds in sediments with low levels of butyltin species (e.g., Main River, 1.7 ng of tributyltin as Sn/g dry sediment).  相似文献   

15.
There have been many methods available for the determination of butyltin compounds in sediment. The variations of these methods are not in the methods of determination but rather in the extraction of these compounds from the complex matrices. All of these methods have not been critically compared or evaluated, mainly because of the lack of a suitable reference sediment for butyltin compounds. Recently, the National Research Council of Canada has introduced a reference sediment (PACS-1) which contains certified values of butyltin compounds. The present study compares the recoveries of ten extraction techniques for butyltin species using ethylation derivatization and GC AA as the method of determination. Of these ten methods, only four were found satisfactory for extraction of the dibutyltin and tributyltin species. None of the methods evaluated, however, could quantitatively extract monobutyltin from sediment.  相似文献   

16.
This study describes a direct comparison of GC and HPLC hyphenated to ICP–MS determination of tributyltin (TBT) in sediment by species-specific isotope dilution analysis (SS-IDMS). The certified reference sediment PACS-2 (NRC, Canada) and a candidate reference sediment (P-18/HIPA-1) were extracted using an accelerated solvent extraction (ASE) procedure. For comparison of GC and LC methods an older bottle of PACS-2 was used, whilst a fresh bottle was taken for demonstration of the accuracy of the methods. The data obtained show good agreement between both methods for both the PACS-2 sediment (LC–ICP–IDMS 828±87 ng g–1 TBT as Sn, GC–ICP–IDMS 848±39 ng g–1 TBT as Sn) and the P-18/ HIPA-1 sediment (LC–ICP–IDMS 78.0±9.7 ng g–1 TBT as Sn, GC–ICP–IDMS 79.2±3.8 ng g–1 TBT as Sn). The analysis by GC–ICP–IDMS offers a greater signal-to-noise ratio and hence a superior detection limit of 0.03 pg TBT as Sn, in the sediment extracts compared to HPLC–ICP–IDMS (3 pg TBT as Sn). A comparison of the uncertainties associated with both methods indicates superior precision of the GC approach. This is related to the better reproducibility of the peak integration, which affects the isotope ratio measurements used for IDMS. The accuracy of the ASE method combined with HPLC–ICP–IDMS was demonstrated during the international interlaboratory comparison P-18 organised by the Comité Consultatif pour la Quantité de Matière (CCQM). The results obtained by GC–ICP–IDMS for a newly opened bottle of PACS-2 were 1087±77 ng g–1 Sn for DBT and 876±51 ng g–1 Sn for TBT (expanded uncertainties with a coverage factor of 2), which are in good agreement with the certified values of 1090±150 ng g–1 Sn and 980±130 ng g–1 Sn, respectively.  相似文献   

17.
Severn Sound is a heavily used recreational and beating area in the southeast corner of Georgian Bay, Lake Huron, Canada. Because of the concern over the possible release of tributyltin species (TBT) from antifouling paints on boat hulls and marinas, surveys were carried out in 1989 and 1992 to determine the presence of this species and its degradation products dibutyltin (DBT) and monobutyltin (MBT) in this area. Many fish (pike and young–of–the–year spottail shiners) and sediment samples collected in 1989 contained detectable levels of TBT. A maximum concentration of TBT was recorded in northern pike in the spring to be 240 ng Sn g?1. Maximum levels occurred in marinas during the beginning of the boating season and significantly reduced during the summer and early autumn, although the maximum value of TBT in sediment (392 ng Sn g?1) was observed in the summer of 1989. The seasonal variation of TBT levels was further substantiated in the subsequent 1992 study, in which sediments from three areas in a marina were sampled at monthly intervals from May to October. TBT levels were much higher in May and then generally decreased with time. Mussels (Elliptio complanta) caged in the marina for three months also contained TBT. DBT was frequently detected in the sediments but less frequently in fish and mussels. MBT was generally below detection limits. Plants (macrophytes and cladophora) contained very small amounts of butyltin compounds.  相似文献   

18.
Butyltin (tributyltin TBT; dibutyltin DBT and monobutyltin MBT) speciation was measured in the liver of beluga whales from the St Lawrence Estuary and Hudson Strait (northern Quebec). Using GC–MS, liver samples were analysed from 21 beluga whales found dead, stranded along the shores of the St Lawrence during the period 1995–1998. In all cases, including a neonate specimen, the liver was contaminated with butyltin compounds with concentrations in the range 0.04–2.1 mg Sn kg−1 on a dry weight basis. Liver samples of five beluga whales from Hudson Strait obtained in the summer of 1998 were also analysed. For these animals, hepatic butyltin concentrations were consistently below the detection limit (<0.5 ng Sn g−1 for MBT and <0.2 ng Sn g−1 for DBT and TBT). Compared with published data on the contamination by TBT of the marine mammals of the St Lawrence in 1988, these contemporary results clearly indicate that the level of contamination of the beluga whales in this coastal marine ecosystem has not decreased ten years after regulating the use of TBT‐based antifoulants on small craft. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

19.
The concentrations of butyltin compounds in seawater were measured at nine sites in the UK during 1986. In popular yachting centres concentrations of tributyltin (TBT) ranged from less than detectable ( < 1 ng dm?3) in the winter, up to 1500 ng dm?3 in marinas in the summer. Measurements of wastewater generated by high-pressure hosing of yachts demonstrated that even higher environmental concentrations of TBT resulted from the procedure. The results of the monitoring programme are discssed in relation to the toxicity of TBT and recent government legislative actions.  相似文献   

20.
Interferences affecting the determination of butyltin species by sodium tetraethylborate (STEB) derivatisation followed by purge-trap preconcentration were systematically studied using synthetic solutions, natural water samples and sediment extracts. Substances that did not cause interferences included most common cations (apart from those metal ions listed below), anions, metalloids and polar organic compounds. Natural organic matter (NOM) specifically interfered with tributyltin (TBT) due to a mechanism involving partitioning of the butyltin to the hydrophobic portions of the NOM. The metal ions Ag(I) (≥2 μM), Cd(II) (≥2 μM), Cu(II) (≥0.5 μM) interfered predominantly with the determination of monobutyltin (MBT) due to catalytic degradation of the STEB reagent. Pb(II) (≥14 μM) interfered with butyltin determination by an unknown mechanism. Other interferences to the purge-trap method were shown to occur in the presence of chelating agents (e.g. EDTA) or hydrophobic liquids such as diesel fuel. A mixture comprising methanol (MeOH), EDTA and Mn(II) was used to partially mask the effect of interfering NOM and metals. Spike recoveries (mean±S.D. of n=7 different samples) of MBT, dibutyltin (DBT) and TBT in contaminated natural water samples were improved from 70±36,90±11 and 91±24 to 102±10,98±3 and 98±4%, respectively. Spike recoveries (mean±S.D. of n=5 different samples) of MBT, DBT and TBT in aliquots of sediment extracts were improved from 86±17,79±18 and 59±32 to 97±6.2,103±3.6 and 103±5.0%, respectively. The ability to analyse larger aliquots of sediment extracts in the presence of the masking mixture improved the detection limit four-fold if MBT and DBT determination was required and 10-fold if only TBT determination was required.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号